FIND US AT @DMPALARMS ON MOST SOCIAL PLATFORMS.
WIRELESS BURGLARY CONTROL PANEL
▸ 900 MHz Two-Way Wireless™ and
®
built on board
Z-Wave
▸ Designed for fast, reliable wireless
installations
▸ Cellular, Wi-Fi and network
communication to monitoring
center
▸ 99 two-way, 900 MHz wireless
with up to 48 pre-named zones
▸ Supports seven fully functional
two-way wireless keypads
▸ Supports up to eight two-way
wireless key fobs or outputs
▸ Supports eight fully functional
two-way wireless sirens
▸ Remote panel updates via cellular
or network
▸ Auto keypad pairing for 9800
Series wireless keypads
FEATURES
▸ Small plastic enclosure
can be easily mounted or
located anywhere and can
be customized with your
logo light pipe
▸ Uses cellular services from
SecureCom Wireless®
with a modular cellular
communicator and external
antenna
▸ Remote control via
Virtual Keypad™ or
VirtualKeypad.com
▸ EASYconnect™ connection
for the Virtual Keypad app
when used with a Wi-Fi or
network connection
▸ All/Perimeter, Home/Sleep/
Away or six Areas
▸ 99 four-digit user codes
with authority levels
▸ 200-event memory
▸ Auto WPS on Wi-Fi models
▸ Supports 140 Z-Wave devices
▸ Arm only, ambush code and
temporary user code options
▸ Built-in standby battery
▸ Built-in programming from
any keypad
▸ Selectable automatic
arming and disarming
PLACE YOUR LOGO HERE
▸ Open/Close schedules with
Closing Check
▸ Late to Open/Early to Close
and Trac Count features
for retail applications
▸ Attrition Detection™ monitors
system for arming activity
▸ Programmable user
inactivity monitor watches
for on-site activity
▸ Remote program/download
with Remote Link™, Dealer
Admin™ or Tech APP™
▸ 16-character zone, user and
area names

FIND US AT @DMPALARMS ON MOST SOCIAL PLATFORMS.
DEALER MANAGEMENT
FEATURES
ONBOARD OPTIONS: CELLULAR, WI-FI AND
NETWORK
The XTLplus can be configured to use
dual communication with Wi-Fi or
network as primary and cellular as backup.
DIRECT DATA TRANSMISSION
The cellular communicators or network/
Wi-Fi data network transmit messages
directly from the panel to the monitoring
center. All of the messages being sent by
the control panel are received directly by
a DMP monitoring center receiver. There
is no retransmission or reinterpretation of
the information. Direct reporting means
faster response, with no concerns about
signals not being properly relayed or
intermediate communication links failing.
RECEIVER 1 AND 2 OPERATION
Select one or two receivers for messages
regarding alarms, supervisory/trouble,
opening/closing and test reports. Send
all messages to both receivers or identify
one receiver for alarms and the second
for reports or trouble messages to alert
only the proper responder.
ONBOARD WIRELESS
The XTLplus control panel includes a
high-gain wireless receiver on board
supporting the 1100 Series™ wireless
devices. These 900 MHz frequencyhopping, spread-spectrum devices
feature two-way communication for
superior operation, supervision and
battery life. Two-way communication
minimizes repetitive signaling and helps
to quickly identify missing transmitters.
With 99 wireless zones, the transmitter
options are more than sucient for
most installs. The XTLplus’ unique
wireless features include motion
detectors that are configurable over
the air. Also included are eight key
fob zones or eight wireless outputs
including arm/alarm LED, wireless
sirens and wireless relays. All of
these features make the XTLplus a
perfect choice for residential or small
commercial applications.
HOME/SLEEP/AWAY
For residential applications, the
homeowner can press one button to
select each of three separate arming
options. They can select Home to arm
the perimeter of the home but allow
for movement within the house. Select
Sleep to arm the perimeter and only
specified areas inside their home, leaving
sensors near bedrooms disarmed.
Selecting Away fully arms all elements of
the system.
ALL/PERIMETER
In business applications, system users can
quickly select All to completely arm the
system as they leave the facility for the
day. They also have the option to select
Perimeter, arming all exterior sensors
at doors and windows but disarming all
interior sensors so employees can move
freely around the facility.
CROSS ZONING
This powerful, false-alarm-reduction
feature allows zones to be cross-zoned
and report alarms only when two or
more zones fault within a programmable
time of 4 to 250 seconds. If one zone
trips, only a zone fault report is sent to
the monitoring center.
POWERING THE PANEL
The panel is powered by a small 12-volt
plug-in power supply. Standby battery
is included.
FULLY SUPERVISED
You’re kept fully informed of system
status. The unit sends full reporting
messages including zones, areas
and users, with all names and details
included. Full supervision ensures that
the cellular or network communication
path is intact and functional.
ONE-STOP CELLULAR
SecureCom Wireless provides a reliable
wireless solution for the XTLplus
transmission of alarm signals to the
monitoring center receiver.
See SecureComWireless.com for
more information.
TECHNOLOGY
EASYconnect enables the control panel
to establish an outbound connection to
SecureCom over Wi-Fi or network. This
allows for an eortless installation of
network panels without any customer
router programming, providing
extremely quick app connection times.
FAST PROGRAMMING
Fast Programming lets your installers
power through most programming data
inputs and lets them get the job done
faster. When the panel programming
defaults are acceptable for installation,
and only basic programming options
are needed, Fast Programming
allows the technician to quickly enter
information without navigating all of the
programming menus.
▸ Receiver IP
▸ Weather Zip Code
▸ System (Area, A/P or H/S/A)
▸ Hours from GMT
▸ Wireless Siren Serial Number
▸ Zone Information
All standard programming options are
still available in the programming menu
from the keypad, Tech APP, Dealer
Admin or Remote Link.
AUTO WPS
The XTLplus control panel provides the
ability to connect to a Wi-Fi network
easily with the Auto WPS feature.
Once the XTLplus is powered on, users
press the WPS button on the router
to connect the XTLplus to the Wi-Fi
network automatically. If Auto WPS
is unavailable, the list of available
Wi-Fi networks will pop up on the
9800 keypad to manually select your
preferred network.
BUILT-IN PROGRAMMER
An internal English-text programmer
enables technicians to easily program
and test the panel from any keypad. A
lockout code restricts access to only
authorized persons.
ATTRITION DETECTION PROMPTS YOU
TO CALL YOUR CUSTOMER
The exclusive DMP Attrition Detection
feature gives you advance warning
that a customer may be preparing to
cancel their monitoring contract. With
this feature activated, you will receive
a notification if there has been no
system activity for the number of days
you select.
WIRELESS KEYPAD ASSOCIATION
This is a great time-saver for installers.
Any keypad not associated with
another panel is accepted and assigned
to the first open keypad address
available. Keypads are automatically
assigned based on the order in which
they are detected. A maximum of
seven keypads may be associated with
a panel.
REMOTE PROGRAMMING
Remotely program panels using the
Tech APP, DMP Remote Link software
or the Dealer Admin site. Upload panel
programming, make the necessary
programming change and then
download the revised programming
into the panel.
FIELD PANEL UPDATES
The 401 USB Flash Module allows you to
easily field update firmware for
panels that would otherwise require
the use of a computer and a 399
Programming Harness.