1100X SERIES WIRELESS RECEIVER
Installation Guide
PROGRAM THE PANEL
Refer to the panel programming guide as needed.
1. Reset the panel.
WALL
TAMPER
ENABLE
DISABLE
Figure 1: 1100X Series
Wireless Recever
RF RX RF TX
PANEL RX PANEL TX
STATUS PWR
DESCRIPTION
The 1100X Series Wireless Receiver
provides up to 100wireless zones
for XR150 Series panels and up
to 500 wireless zones for XR550
Series panels. The 1100XE features
128-bit AES encryption.
The 1100X also provides two-way
communication using 900MHz
frequency hopping-spread-
spectrum technology.
The 1100X is equipped with a case
and wall tamper.
Compatibility
XR150/XR550 Series Panels
Encryption requires panel Version 183 or higher
1100T Translator requires receiver firmware Version 207/301 or higher
What is Included?
1100X Wireless Receiver
Model 300 Harness
Hardware Pack
1
2
3
2. At a keypad, enter 6653 (PROG) to access the PROGRAMMER menu.
3. In SYSTEM OPTIONS, program a HOUSE CODE between 1 and 50. See House Code Explained for more information.
4. (1100XE only) At the 1100 ENCRYPTION prompt, select ALL to only add encrypted wireless devices to the system. Select BOTH to allow both encrypted and non-encrypted wireless devices to be programmed.
5. (1100XE only) The default passphrase appears at ENTER PASSPHRASE. Press CMD to keep the default. Press any select key or area to change the passphrase and enter an 8-character hexadecimal string (0-9, A-F).
6. Press CMD until STOP displays. Press a top row select key or area to save programming.
SELECT A LOCATION
The receiver should be centrally located between the DMP panel and the 1100 Series transmitters used in the installation based on the wiring specifications below. Use an 1106 Series Universal Wireless Transmitter to perform an LED survey.
1. With the cover removed, hold the transmitter in the desired location.
2. Press the tamper switch to send data to the panel and determine if communication is confirmed or faulty.
Confirmed: If communication is confirmed, for each press or release of the tamper switch, the LED blinks immediately on and immediately o.
Faulty: If communication is faulty, the LED remains on for about 8 seconds or flashes multiple times in quick succession. Relocate the receiver until the LED confirms clear communication.
MOUNT THE 1100X
1. Remove the cover from the plastic housing.
2. Use the included #6 screws to secure the 1100X to the wall. See Figure 2 for mounting hole locations.
3. Use one of the provided screws to secure the wall tamper. See Figure 2 for tamper location.
Tamper Puck
Wall Tamper
Mounting Hole
Figure 2: Inside of the 1100X Housing
Page 2
4
WIRE THE RECEIVER
The panel immediately recognizes the 1100X if the panel is programmed with a house code. Do not use shielded wire between the panel and receiver.
1. Connect the red, yellow, green, and black wires to the PANEL terminal on the 1100X.
2. Connect the other end of the wires to the XBUS on the panel. See Figure 2.
3. Snap the cover back on to the base. Note: The receiver can’t operate if it’s connected to the keypad bus.
Power LED
Battery Start
XR150/XR550
Series Panel
XMT - Transmit LED
REC - Receive LED
Can be extended from the panel
up to 500ft using 22AWG
or 1,000ft using 18 AWG.
Figure 3: Wire the 1100X to the Panel
Mounting Hole Locations
WALL
TAMPER
ENABLE
DISABLE
1100X Series
Receiver
TAMPER
PANEL
RF RX RF TX
PANEL RX PANEL TX
STATU S PWR
ADDITIONAL INFORMATION
Wiring Specifications for X-Bus
1. DMP recommends using 18 or 22-gauge unshielded wire for all keypad and LX-Bus circuits. Do Not use twisted pair or shielded wire for LX-Bus and Keypad Bus data circuits. To maintain auxiliary power integrity when using 22-gauge wire do not exceed 500 feet. When using 18-gauge wire do not exceed 1,000 feet. Install an additional power supply to increase the wire length or add devices.
2. Maximum distance for any one circuit (length of wire) is 2,500 feet regardless of the wire gauge. This distance can be in the form of one long wire run or multiple branches with all wiring totaling no more than 2,500 feet. As wire distance from the panel increases, DC voltage on the wire decreases.
3. Maximum number of devices per 2,500 feet circuit is 40.
4. Maximum voltage drop between the panel (or auxiliary power supply) and any device is 2.0VDC. If the voltage at any device is less than the required level, add an auxiliary power supply at the end of the circuit. When voltage is too low, the devices cannot operate properly. Refer to the panel installation guide and LX-Bus/Keypad Bus Wiring Application Note (LT-2031).
Programming Zones
Refer to the panel XR150/XR550 Series Programming Guide (LT-1232) for complete wireless programming information. When any wireless input zone for a particular address is programmed, the 1100XH responds to the panel for this address. Other devices, such as keypads or hardwired zone expanders, cannot use this address. Zones connected directly to the panel cannot be wireless. See Table 1 for designated zone numbers.
DMP PANEL AVAILABLE ZONES ZONE RANGES
XR150 (1100X Series) 100 500 - 599
XR550 (1100X Series) 500 500 - 999
Table 1: Zone Number Designations
2 1100X SERIES WIRELESS RECEIVER | DIGITAL MONITORING PRODUCTS
Page 3
1100X LED Operation
The six labeled LEDs on the 1100X PCB display wireless receiver operation and activity. See Table 2 for LED locations and Table 1 for LED indications.
House Code Explained
The house code identifies the panel, receiver, and transmitters to each other. The 1100X automatically sends the specified house code to wireless transmitters when transmitter serial numbers are programmed into the panel. The 1100X only listens for transmissions using the specified house code or the programmed transmitters’ serial numbers.
LED INDICATIONS
RF RX Flashing yellow indicates
data is being received from a transmitter.
RF TX Flashing green indicates data is
being sent to a transmitter.
PANEL RX Flashing yellow indicates data
is being received from a panel.
PANEL TX Flashing green indicates data is
being sent to the panel.
STAT US Solid red indicates memory is
being uploaded. Turns o when complete.
PWR Solid green indicates there is
power to the wireless receiver.
Table 2: LED Indications
Transmitter Supervision Time
For listed installations, program the transmitter supervision time in panel zone programming as listed in the following table. Refer to the panel programming guide for complete wireless programming information.
UL Listing Listed Accessories Supervision Time
1164 Synchronized Smoke Detector
UL 268 Smoke-Automatic Fire Detectors
1164NS Smoke Detector with No Sounder 1168 Smoke/CO/Low Temp Detector
3
UL 365 Police Station Connected Burglar Accessory 1103 Universal Transmitter 60
UL 521 Heat Detectors for Fire Protective Signaling Systems
UL 609 Local Burglar Alarm Units and System Accessory 1103 Universal Transmitter 60
UL 634 Connections and Switches for use with Burglar Alarm Systems Accessory
UL 636 Holdup Alarm Units and Systems Accessory 1142 Two-Button Holdup Transmitter 60
UL 639 Intrusion Detection Units Accessory 1127W, 1127C PIR Motion Detectors 60
UL 864 Fire Protective Signaling Systems 1103 Universal Transmitter 3
UL 985 Household Fire Warning System Accessory
UL 1023 Household Burglary System Units Accessory
UL 1076 Proprietary Burglar Alarm Units Accessory
UL 1610 Central Station Burglar Alarm Units Accessory
UL 2075 Gas and Vapor Detectors and Sensors
1183-135F, 1183-135R Heat Detector 3
1101, 1102, 1103, 1106 Universal Transmitters 60
1135 Siren 9060, 9063, 9862 Wireless Keypads
1101, 1102, 1103, 1106 Universal Transmitters 1127W, 1127C PIR Motion Detectors 1135 Siren 1142 Two-Button Holdup Transmitter 9060, 9063, 9862 Wireless Keypads
1103 Universal Transmitter 9862 Wireless Graphic Touchscreen Keypad
1103 Universal Transmitter 1135 Siren 9060, 9063, 9862 Wireless Keypads
1184 Wireless Carbon Monoxide Detector 1168 Wireless Smoke/CO/Low Temp Detector
240
60
60
60
240
Table 3: Wireless Transmitter Supervision Times
Note: The 1100R Wireless Repeater and 1100T Wireless Translator follow the Receiver Supervision times for Listed
Accessories.
1100X SERIES WIRELESS RECEIVER | DIGITAL MONITORING PRODUCTS 3
Page 4
LISTED COMPLIANCE SPECIFICATIONS
For applications that must conform to a National Recognized Testing Laboratory certified system, read the information below for additional information.
Commercial Fire
Transmitters must be programmed as supervised. Refer to Table 3 for specific supervision times. The maximum line impedance of the 4-wire bus is 16.2 Ohms for 1,000 feet (305 meters). The recommended wire gauge for panel to receiver connection is 22 AWG. After all transmitters are in position, the WLS option of the panel’s Walk Test must be operated and all transmitters programmed for Fire (FI) or Supervisory (SV) must show that their check-in message was received. Refer to the panel programming guide for Trip Counter for DMP Wireless Check-in Test (WLS) which describes that both numbers of the counter must match. If not and a failed wireless zone is displayed at END, decrease that transmitter’s range with the receiver and perform the Wireless Walk Test again.
FCC INFORMATION
This device complies with Part 15 of the FCC Rules. Operation is subject to the following two conditions:
1. This device may not cause harmful interference, and
2. this device must accept any interference received, including interference that may cause undesired operation.
The antenna used for this transmitter must be installed to provide a separation distance of at least 20cm (7.874 in.) from all persons. It must not be located or operated in conjunction with any other antenna or transmitter. Changes or modifications made by the user and not expressly approved by the party responsible for compliance could void the user’s authority to operate the equipment.
Note: This equipment has been tested and found to comply with the limits for a Class B digital device, pursuant to part 15 of the FCC Rules. These limits are designed to provide reasonable protection against harmful interference in a residential installation. This equipment generates, uses and can radiate radio frequency energy and, if not installed and used in accordance with the instructions, may cause harmful interference to radio communications. However, there is no guarantee that interference will not occur in a particular installation. If this equipment does cause harmful interference to radio or television reception, which can be determined by turning the equipment o and on, the user is encouraged to try to correct the interference by one or more of the following measures:
1. Reorient or relocate the receiving antenna.
2. Increase the separation between the equipment and receiver.
3. Connect the equipment into an outlet on a circuit dierent from that to which the receiver is connected.
4. Consult the dealer or an experienced radio/TV technician for help.
INDUSTRY CANADA INFORMATION
This device complies with Industry Canada Licence-exempt RSS standard(s). Operation is subject to the following two conditions:
1. This device may not cause interference, and
2. this device must accept any interference, including interference that may cause undesired operation of the device.
This system has been evaluated for RF Exposure per RSS-102 and is in compliance with the limits specified by Health Canada Safety Code 6. The system must be installed at a minimum separation distance from the antenna to a general bystander of 7.87 inches (20 cm) to maintain compliance with the General Population limits.
Le présent appareil est conforme aux CNR d’Industrie Canada applicables aux appareils radio exempts de licence. L’exploitation est autorisée aux deux conditions suivantes:
1. l’appareil ne doit pas produire de brouillage, et
2. l’utilisateur de l’appareil doit accepter tout brouillage radioélectrique subi, même si le brouillage est susceptible d’en compromettre le fonctionnement. L’exposition aux radiofréquences de ce système a été évaluée selon la norme RSS-102 et est jugée conforme aux limites établies par le Code de sécurité 6 de Santé Canada. Le système doit être installé à une distance minimale de 7.87 pouces (20 cm) séparant l’antenne d’une personne présente en conformité avec les limites permises d’exposition du grand
public.
1100X SERIES WIRELESS RECEIVER
Specifications
Operating Voltage 12VDC Nominal Current Draw 25mA (average), 35mA (peak) Frequency Range 905-924MHz Housing Dimensions 5.5”W x 3.75”L x 1”H Housing Color White Housing Material Flame Retardant ABS
Patents
U.S. Patent Number 7, 239, 236
Ordering Information
1100X-W Standard Wireless Receiver 1100XE-W Encrypted Wireless Receiver
Certifications
California State Fire Marshal (CSFM)
New York City 1100 Series Wireless (FDNY COA #6167) FCC Part 15: CCKPC0114R6 Industry Canada: 5251A-PCO114R6
Underwriters Laboratory (UL) Listed
ANSI/UL 365 Police Station Connected Burglar
ANSI/UL 609 Local Burglar Alarm Unites and Systems
ANSI/UL 1023 Household Burglar Alarm System Units
ANSI/UL 1076 Proprietary Burglar Alarm Units
ANSI/UL 1610 Central Station Burglar Alarm Units
ANSI/UL 864 Fire Protective Signaling Systems
ANSI/UL 985 Household Fire Warning System
Compatible With Devices Listed for:
ANSI/UL 268 Smoke Detectors for Fire Alarm Signaling Systems
ANSI/UL 634 Connections and Switches for use with Burglar Alarm Systems Accessory
ANSI/UL 636 Safety Holdup Alarm Units and Systems
ANSI/UL 639 Intrusion Detections Units Accessory
ANSI/UL 2075 Gas and Vapor Detectors and Sensors
Designed, engineered, and
manufactured in Springfield, MO
using U.S. and global components.
LT-1822 1.01 21062
© 2021
INTRUSION • FIRE • ACCESS • NETWORKS
2500 North Partnership Boulevard
Springfield, Missouri 65803-8877
800.641.4282 | DMP.com