NO. Name Def. Valid A B Description
6
(*)
MultSensor 
Function 
Switch
4 All
Multisensor function switch. Using bit 
to control.
0  
Bit0: Disable magnetic integrate 
illumination to turn ON the lighting 
nodes in the association group 2. 
(1:Disable, 0:Enable)
0  
Bit1: Disable PIR integrate 
Illumination to turn ON the lighting 
nodes in the association group 2. 
(1:Disable, 0:Enable)
1  
Bit2: Disable magnetic integrate PIR  
to turn ON the lighting nodes in the 
association group 2. (1:Disable, 
0:Enable) (Default is Disable)
0  
Bit3: When Bit2 is 0 (Enable), Are the 
device and the lighting in the same 
room? 
 0: In the same room(Default), 
 1: In the different room. 
Notice: If this bit is 1, it is 
recommended also set the Bit1 to 1, 
cause  the PIR triggered, doesn't 
mean the people in that room.
0  
Bit4: Disable delay 5 seconds to turn 
off the light, when door/window 
closed. (1:Disable, 0:Enable)
0   Bit5: Disable auto turn off the light, 
after door/window opened to turn on 
the light. (1:Disable, 0:Enable)
Notice: If bit2 is zero, this setting is 
useless. 
Notice: If the configuration No.9 is 
zero, this setting is useless.
0   Bit6: Reserve. 
0   Bit7: Reserve.
NO. Name Def. Valid A B Description
NO. Name Def. Valid A B Description
7
(*)
Customer 
Function
4 All
Customer function switch, using bit 
control.
0   Bit0: Reserve.
0  
Bit1: Enable sending motion OFF 
report. (0:Disable, 1:Enable) 
Note: Depends on the Bit4, 
0: Report Notification CC, 
Type: 0x07, Event: 0xFE 
1: Sensor Binary Report, 
Type: 0x0C, Value: 0x00
1  
Bit2: Enable PIR super sensitivity 
mode. (0:Disable, 1:Enable)
0  
Bit3: Disable send out BASIC OFF 
after door closed. (1:Disable, 
0:Enable)
0  
Bit4: Notification Type,  
    0: Using Notification Report. 
    1: Using Sensor Binary Report.
0  
Bit5: Disable Multi CC in auto report. 
(1:Disable, 0:Enable)
0   Bit6: Disable to report battery state 
when the device triggered. (1:Disable, 
10