D Link CHZ110A1 User Manual

DCH-Z110/Z120
The sensor DCH-Z110/Z120 have PIR or door/window integrated with, temperature and illumination, which are 3 sensors function in one, based on Z-WaveTM technology. It is the Z-WaveTM plus product, it supports the security, OTA... Those newest features of the Z-WaveTM technology. Z-WaveTM is a wireless communication protocol designed for home automation, specifically to remotely control applications in residential and light commercial environments. The technology uses a low-power RF radio embedded or retrofitted into home electronics devices and systems, such as lighting, home access control, entertainment systems and household appliances.
This product can be included and operated in any Z-WaveTM network with other Z-WaveTM certified devices from other manufacturers and/or other applications. All non-battery operated nodes within the network will act as repeaters regardless of vendor to increase reliability of the network.
The device adopt the Z-WaveTM 500 series chip, when your Z-Wave
TM
network system is all made by Z-WaveTM 500 series devices. The network system will have the advantages as below.
Concurrent multi-channel support reduces external interference.
Better RF range, improve about 10 meters in indoor.
Support 100 Kbps transmit speed, speed up communication.
Function Compare DCH-Z110/DCH-Z120
PIR Door/Window Temperature Illumination
DCH-Z110 V V V
DCH-Z120 V V V
Add to/Remove from Z-WaveTM Network
There are two tamper keys in the device, one is in the back side, another is in the front side. Both of them can add, remove, reset or association from Z-WaveTM network.
In the first time, add the device into the Z-WaveTM network. First, make sure the primary controller is in the add mode. And then power on the device, just take out the insulation Mylar in the back side of the device. The device will auto start the NWI (Network Wide Inclusion) mode. And it should be included in 5 seconds. You will see the LED light ON one second.
1
Notice: Including a node ID allocated by Z-WaveTM Controller means Add” or “Inclusion”. Excluding a node ID allocated by Z-WaveTM Controller means “Remove” or “Exclusion”.
Function
Description
Add
1.Have Z-WaveTM Controller entered inclusion mode.
2.Pressing tamper key three times within 1.5 seconds
to enter the inclusion mode.
3.After add successful, the device will wake to receive the setting command from Z-WaveTM Controller about 20 seconds.
Remove
1.Have Z-WaveTM Controller entered exclusion mode.
2.Pressing tamper key three times within 1.5 seconds to enter the exclusion mode.
Node ID has been excluded.
Reset
Notice: Use this procedure only in the event that the primary controller is lost or otherwise inoperable.
1.Pressing tamper key four times within 1.5 seconds and do not release the tamper key in the 4th pressed, and the LED will light ON.
2.After 3 seconds the LED will turn OFF, after that within 2 seconds, release the tamper key. If successful, the LED will light ON one second. Otherwise, the LED will flash once.
3.IDs are excluded and all settings will reset to factory default.
Association
1.Have Z-WaveTM Controller entered association mode.
2.Pressing tamper key three times within 1.5 seconds
to enter the association mode. Note: The device support 2 groups. The group 1 is for
receiving the report message, like triggered event, temperature, illumination etc. The group 2 is for light control, the device will send the “Basic Set” command to this group. And each group support 8 nodes maximum.
Failed or success in add/remove the node ID can be viewed from Z­WaveTM Controller.
Notice 1: Always RESET a Z-WaveTM device before trying to add it to a Z-WaveTM network
Notice 2: When the device into NWI mode, the sensor functionality will useless. The NWI mode will timeout after 30 seconds. You can press the tamper key 3 times to abort the NWI mode.
Z-WaveTM Notification
After the device adding to the network, it will wake-up once per day in default. When it wake-up it will broadcast the “Wake Up Notification” message to the network, and wake-up 10 seconds for receive the setting commands. The wake-up interval minimum setting is 30 minutes, and maximum setting is 120 hours. And the interval step is 30 minutes.
If the user want to wake-up the device immediately, please remove the front cover, and press the tamper key once. The device will wake-up 10 seconds.
Z-WaveTM Message Report
When the PIR motion triggered or the door/windows triggered, the device will report the trigger event and also report the battery status, temperature and illumination level. In default the device will using Notification Report to represent the trigger event, it can be changed to Sensor Binary Report by setting the configuration NO. 7 Bit4 to 1.
2
* Motion Report:
When the PIR motion detected, the device will unsolicited to send the report to the nodes in the group 1.
Notification Report (V4)
Notification Type: Home Security (0x07) Event: Motion Detection, Unknown Location (0x08)
Sensor Binary Report (V2)
Sensor Type: Motion (0x0C) Sensor Value: 0xFF
* Door/Window Report:
When the door/window state changed, the device will unsolicited to send the report to the nodes in the group 1.
Notification Report (V4)
Notification Type: Access Control (0x06) Event: Door/Window is open (0x16) Door/Window is closed (0x17)
Sensor Binary Report (V2)
Sensor Type: Door/Window (0x0A) Sensor Value: 0x00 is closed, 0xFF is opened.
* Tamper Report:
Both the 2 tamper keys are pressed over 5 seconds. The device will into the alarm state. In that state, if any one of the tamper keys be released, the device will unsolicited to send the report to the nodes in the group 1.
Notification Report (V4)
Notification Type: Home Security (0x07)
Event: Tampering. Product covering removed (0x03)
Sensor Binary Report (V2)
Sensor Type: Tamper (0x08) Sensor Value: 0xFF
* Temperature Report:
When the PIR motion detected or the door/window state changed, the device will unsolicited to send the “Sensor Multilevel Report” to the nodes in the group 1. Sensor Type: Temperature (0x01) Note: To disable this functionality by setting the configuration N0.5 bit5 to 1. *** Temperature differential report *** This function default is enabled, to disable this function by setting the configuration NO.21 to 0. In the default, when the temperature is changed to plus or minus one degree Fahrenheit (0.56 degree Celsius), the device will report temperature information to the nodes in the group 1. The device will measure the temperature in every one minute. And if the temperature is over 140 degree Fahrenheit (60 degree Celsius), the device will always report in each measurement. Caution 1:
Enable this functionality, it will cause the PIR Motion to disable detection when the temperature measurement. In other words, The PIR motion will blind one second in every one minute.
* Illumination Report:
When the PIR motion detected or the door/window state changed, the device will unsolicited to send the “Sensor Multilevel Report” to the nodes in the group 1. Sensor Type: Luminance (0x03) Note: To disable this functionality by setting the configuration N0.5 bit4 to 1.
*** Illumination differential report ***
3
This function default is disabled, to enable this function by setting the configuration NO.22 not to zero. Enable this functionality, the device will measure the illumination in every one minute. And if the illumination is changed to plus or minus the value (setting by the configuration NO.22), the device will report illumination information to the nodes in the group 1. Caution 1:
Enable this function will reduce the battery life about 15% ~ 20%. And another issue is setting the differential value too small, it will cause report too frequency, shorter the battery life more. Propose the setting differential value should not small than 10.
Caution 2:
If the configuration No.4 is setting to 0 or 100, this
functionality is useless.
Caution 3:
Enable this functionality, it will cause the PIR Motion to disable detection when the illumination measurement. In other words, The PIR motion will blind one second in every one minute.
* Timing Report:
Beside the event triggered could report message, the device also support the timing unsolicited report of the status.
Battery level report: Every 6 hours report once in default. It could be changed by setting the configuration NO. 10.
Low battery report: When the battery level is too low, every 30 minutes will report once.
Door/window state report: Every 6 hours report once in default. It could be changed by setting the configuration NO. 11.
Illumination level report: Every 6 hours report once in default. It could be changed by setting the configuration NO. 12.
Temperature report: Every 6 hours report once in default. It could be changed by setting the configuration NO. 13. Notice: The configuration NO. 10, 11, 12 and 13 could be setting to zero to disable the auto report. And the configuration NO. 20 could change the tick interval, the default value is 30, if setting to 1, that means the minimum auto report interval will be one minute. And please notice if setting this value to zero, that means disable all of the timing report except the low battery detection.
Power Up Procedure
* Battery Power Check
When the device power up, the device will detect the power level of the battery immediately. If the power level is too low, the LED will continue flash about 5 seconds. Please change another new battery.
* PIR Warm Up
When the device power on, the PIR need to warm up before the operation. The warm up time about 1 minute, the LED will flash in every 2 seconds. After finish the procedure the LED will light ON three times.
* NWI
When the device power on, the device will check is it already adding to the network? If doesn't, it will auto start the NWI mode. The LED will flash in every second and continue 30 seconds. Until timeout or the device successful to inclusion by controller. The use can presses the tamper key 3 times to abort the NWI mode.
* Wake
When the device power on, the device will wake about 20 seconds. In this duration, the controller can communicate with the device. Normally the device is always sleeping to save the battery energy.
Over The Air (OTA) Firmware Update
The device supports the Z-Wave firmware update via OTA. Before starting the procedure, please remove the front cover of the device. Otherwise the hardware check will be failed. Let the controller into the firmware update mode, and then press the front tamper key once to start the update.
4