Ditec E2 User Manual

Page 1
E2
EN
Installation manual for control panel for automations with two 230 V~ motors with built-in radio.
rev. 2010-07-19
IP1935EN
F1
LN
UWV XZY
com
com
PRG
SIG
ANT
JR1
COM
BIXMR2
B
ON
OFF
123 4 5 6
ON
OFF
TRRFR1 TC TM
15 13 12 11 0 1 15689
-
+
AUX
GOL4
A
123 4
IN 11 12
SA
POWER
Flashing light
230V~
230V~
Lamp
Electric lock
Motor 1 Motor 2
M2 closing limit switch
M1 closing limit switch
Output 24 V= / max 0,5 A
Power supply
DITEC S.p.A.
Via Mons. Banfi, 3 - 21042 Caronno Pertusella (VA) - ITALY Tel. +39 02 963911 - Fax +39 02 9650314 www.ditec.it - ditec@ditecva.com
Stop
Safety stop
Step-by-step
Safety re-opening
Page 2
INDEX
Subject Page
1. *eneral safet\ precautions 3
2. EC declaration of conformit\ 4
3. Technical data 4
3.1 Applications
4. Connection of power suppl\ 4
5. Commands 5
6. Outputs and accessories 6
7. Adjustments 7
8. Radio receiver operation 9
9. Start-up 9
10. TroubleshootinJ 10
11. Example application for Jates with one swinJinJ door winJ 11
12. Example application for Jates with two swinJinJ door winJs 13
13. Hold-to-run function mode 15
4
All right reserved
All data and speci¿cations have been drawn up and checNed with the Jreatest care. The manufacturer cannot however taNe an\ responsibilit\ for eventual errors, ommisions or incomplete data due to technical or illustrative purposes.
IP1935EN 2010-07-19
2
Page 3
1. GENERAL SAFETY PRECAUTIONS
This installation manual is intended for professionall\ competent personnel onl\.
The installation, the power connections and the settinJs must be completed in conformit\ with *ood :orNinJ Methods and with the reJulations in force. Before installinJ the product, carefull\ read the instructions. Bad installation could be ha]ardous. The pacNaJinJ materials (plastic, pol\st\rene, etc.) should not be discarded in the environment or left within reach of children, as these are a potential source of ha]ard. Before beJinninJ the installation checN that the product is in perfect condition. 'o not install the product in explosive areas and atmospheres the presence of Àammable Jas or fumes re­presents a serious threat to safet\. The safet\ devices (photocells, sensitive edJes, emerJenc\ stop, etc.) must be installed taNinJ into account the provisions and the directives in force, *ood :orNinJ Methods, the installation area, the functional loJic of the s\stem and the forces developed b\ the automation.
Before maNinJ power connections, checN that the ratinJ corresponds to that of the mains suppl\. A mul-
tipolar disconnection switch with a contact openinJ Jap of at least 3 mm must be included in the mains suppl\. ChecN that upstream of the electrical installation an adeTuate residual current circuit breaNer and an overcurrent cut out are ¿tted. :hen reTuested, connect the automation to an effective earthinJ s\stem carried out as indicated b\ current safet\ reJulations. 'urinJ installation, maintenance and repair operations, cut off the power suppl\ before openinJ the cover to access the electrical parts.
To handle electronic parts, wear earthed antistatic conductive bracelets. The manufacturer of the moto-
risation declines all responsibilit\ in the event of components which are not compatible with the safe and correct operation of the product. For repairs or replacements of products onl\ oriJinal spare parts must be used.
3
IP1935EN 2010-07-19
Page 4
2. EC DECLARATION OF CONFORMITY
SiSiSiSiSSi
v
An
JJaJaJaJa
J
Ja
Ja
J
ananan
an
an
aan
naJaJ
aJ
aJ
aJaJaJ
aJ
aJaJa
aJ
aJJn
n
J J
re
re
re
re
ororororororor
Manufacturer: DITEC S.p.A. Address: via Mons. Ban¿, 3 21042 Caronno P.lla (VA) - ITALY declares that the control panel E2 (with receiver 433.92 MH]) is in conformit\ with the provisions of the follow­inJ EC directives: R&TTE Directive 1999/5/CE; EMC Directive 2004/108/CE; Low VoltaJe Directive 2006/95/CE.
Caronno Pertusella, 19-07-2010 Silvano AnJaroni (ManaJinJ Director)
3. TECHNICAL DATA
E2 E2J
Power supply 230 V~ / 50 H] 120 V~ / 60 H] F1 fuse F5A F6,3A 1 motor output 230 V~ / 5 A 120 V~ / 6,3 A 2 motors output 230 V~ / 2 x 2,5 A 120 V~ / 2 x 3,15 A Accessories power supply 24 V= / 0,5 A Temperature -20 °C / +55 °C Degree of protection IP55 Memorizable radio codes 200 Radio frequency 433,92 MH]
NOTE: the given operating and performance features can only be guaranteed with the use of DITEC
i
accessories and safety devices.
3.1 Applications
4. CONNECTION OF POWER SUPPLY
Fix the control panel permanentl\. Pass the cables alonJ from the lower side of the container. Before connectinJ the power suppl\, maNe sure the plate data correspond to that of the mains power suppl\. An omnipolar disconnection switch with minimum contact Japs of 3 mm must be included in the mains suppl\. ChecN that upstream of the electrical installation there is an adeTuate residual current circuit breaNer and a suitable overcurrent cutout. 8se a 3x1.5 mm FROR 450/750V t\pe electric cable and connect to the terminals L (brown), N (blue), (\ellow/Jreen) in the automation. Secure the cable usinJ a special cable clamp. MaNe sure there are no sharp edJes that ma\ damaJe the power suppl\ cable. Connection to the mains power suppl\, in the section outside the automation, is made with independent channels and separated from the connections to the control and safet\ devices.
IP1935EN 2010-07-19
4
Page 5
5. COMMANDS
Command Function Description
1
1
1
1
1 1
0 11 N.C. M2 CLOSING
0 11 N.O. M2 PROXIMITY
0
0 12 N.O. M1 PROXIMITY
5 N.O. STEP-BY-STEP
WITH AUTOMATIC CLOSING
STEP-BY-STEP WITHOUT AUTOMATIC CLOSING OPENING WITH AUTOMATIC CLOSING OPENING WITHOUT AUTOMATIC CLOSING
6 N.C. SAFETY STOP With DIP5B=ON, all operations are stopped and/or blocNed
6 N.O. CLOSING With DIP5B=OFF, the closinJ of the contact activates the clo-
8 N.C. REVERSE
SAFETY CONTACT
9 N.C. STOP The openinJ of the safet\ contact stops the current operation. 9 N.O. HOLD-TO-RUN
FUNCTION
LIMIT SWITCH
LIMIT SWITCH
12 N.C. M1 CLOSING
LIMIT SWITCH
LIMIT SWITCH
N.O. TRANSMITTERS
STORAGE AND CANCELLATION
PRG
With DIP1A=OFF and TCMA;, the closinJ of the contact acti­vates openinJ or closinJ operations in the followinJ seTuence: open-stop-close-open.
NOTE: the stop is not permanent but lasts for a duration set by TC.
With DIP1A=OFF and TC=MA;, the closinJ of the contact acti­vates openinJ or closinJ operations in the followinJ seTuence: open-stop-close-open. With DIP1A=ON and TCMA;, the closinJ of the contact acti­vates the openinJ operation.
With DIP1A=ON and TC=MA;, the closinJ of the contact acti- vates the openinJ operation.
NOTE: once the automation stops, the closing of the contact performs the opposite operation to the one performed before stop.
when the safet\ contact is opened.
sinJ operation. The openinJ of the safet\ contact triJJers a reversal of motion (re-openinJ) durinJ closinJ.
With DIP1A=ON and DIP5B=OFF, the openinJ of the 1-9 con­tact enables the hold-to-run function.
- hold-to-run openinJ 1-3;
- hold-to-run closinJ 1-4.
NOTE: any safety device, automatic closing and plug-in card inserted in AUX is disabled.
With TM=MA;, the openinJ of the contact stops the closinJ operation of motor 2 (M2). With TM=MA; and DIP3B=OFF, the openinJ of the contact stops the closinJ operation of motor 1 (M1). See paJe 12-14.
With TM=MAX, the openinJ of the contact stops the closinJ operation of motor 1 (M1). With TM=MAX and DIP3B=OFF, the openinJ of the contact stops the openinJ operation of motor 1 (M1). See paJe 12-14.
WARNING: the BIXMR2 storage module must be inserted.
Transmitter storage:
- press the PRG Ne\ (the SIG LED comes on),
- transmit the transmitter to be stored (the SIG LED Àashes),
- wait 10 s to complete storaJe (the SIG LED Joes out).
Transmitter cancellation:
- press the PRG Ne\ for 3 sec (the SIG LED Àashes),
- press the PRG Ne\ for another 3 sec (the SIG LED Àashes TuicNl\).
WARNING: make a jumper for all the N.C. contacts if not in use. The terminals with the same number are equal.
5
IP1935EN 2010-07-19
Page 6
6. OUTPUTS AND ACCESSORIES
Output Value - Accessories Description
Accessories power supply. Power suppl\ output for external ac-
01
-
+
1 11
1
1
0
12
13
15 12 V= / 15 W
24 V= / 0,5 A
24 V= / 3 W
24 V= / 3 W
24 V= / 3 W
cessories, includinJ automation status lamp.
Open automation lamp. Onl\ with the 0-11 limit switch (N.C.) con-
nected and DIP3B=OFF the liJht switches off when the automation is closed.
Closed automation lamp. Onl\ with the 0-12 limit switch (N.C.)
connected and DIP3B=OFF the liJht switches off when the automa­tion is open.
Open automation lamp. The liJht switches off when the automation
is closed.
Electric lock. Activated upon ever\ openinJ command.
W
X
AUX
COM
N
L
LAMP
230 V~ / 100 W
230 V~ / 100 W
BIXMR2
Flashing light. Activated durinJ openinJ and closinJ operations.
Courtesy light. In 1 motor mode onl\ (with DIP3B=OFF and no motor
connected to terminals X-=-Y), an external courtes\ liJht that turns on for 180 s with ever\ openinJ (total or partial), step-b\-step and closinJ command can be connected. The control panel has one housinJ for pluJ-in cards such as a radio receiver t\pe, maJnetic loops, etc. PluJ-in card operatinJ is selected usinJ DIP1A.
WARNING: the plug-in cards must be inserted and removed with the power supply disconnected.
The storaJe module allows remote controls to be stored. If the control panel is replaced, the BIXMR2 storaJe module beinJ used can be inserted in the new control panel.
WARNING: the storage module must be inserted and removed with the power supply disconnected.
IP1935EN 2010-07-19
6
Page 7
7. ADJUSTMENTS
Description OFF ON
DIP1A Command 1-5 operation.
NOTE: it also sets operating mode of the plugin cards connected on AUX.
DIP2A Restore automatic closing time. 50% 100% DIP3A Automation status at power on.
Indicates how the control panel considers automation when powered up.
DIP4A Electric lock release. Disabled. Enabled. DIP1B Maximum power start. Disabled.
DIP2B FUTURE USE // DIP3B Automation type. 1 motor automation. 2 motors automation. DIP4B Automation model. FACIL Other automations. DIP5B Command 1-6 operation. ClosinJ. Stop. DIP6B Reversal safety switch function. With the automation blo-
Step-b\-step. OpeninJ.
Open.
NOTE: with limit switches installed, preferably set DIP3A=OFF.
The motor starts with the voltaJe set with trimmer RF.
cNed, if the contact 1-8 is open, it is possible to activa­te the openinJ operation.
Closed.
NOTE: if the automatic clo­sing function is not used, preferably set DIP3A=ON.
Enabled. The motor starts at maxi­mum power for 1 s.
With the automation blo­cNed, if the contact 1-8 is open, an\ operation is im­possible.
Description OFF ON
JR1 Incorporated radio receiver. Disabled. Enabled.
7
IP1935EN 2010-07-19
Page 8
Trimmer Description
RF
min max
TR
0 s
10 s
3 s
20 s
30 s
Power adjustment. Adjusts the voltaJe supplied to the motor.
Setting motor 1 (M1) closing delay time. From 0 to 30 s.
When closinJ, motor 1 (M1) arrives after a dela\ set with trimmer TR relative to motor 2 (M2). When openinJ, motor 2 (M2) starts after a dela\ of 3 s relative to motor 1 (M1). With TR=MIN the door winJs start simultaneousl\.
NOTE: setting TR=MIN with non-overlapping door wings and setting TR>3 s with overlapping door wings is recommended.
R1
Obstacle thrust adjustment.
The control panel is eTuipped with a safet\ s\stem that stops motion if an obstacle is
min Disabled
encountered durinJ an openinJ operation and stops or inverts the movement durinJ a closinJ operation. R1=MIN Jives maximum obstacle sensitivit\ (minimum thrust). R1=MAX disables obstacle detection (maximum thrust).
TC
120 s
0 s Disabled
Setting automatic closing time. From 0 to 120 s.
With DIP2A=OFF, once a safet\ switch has been activated, the counter starts as soon as the safet\ switch is released (for example after passinJ throuJh the photocells), and lasts for a period of time set with trimmer TC (50%). With DIP2A=ON, the counter starts when automation is opened and lasts for the entire duration set with trimmer TC (100%).
NOTE: after the activation of the stop command, once contact 1-9 has closed again, automatic closing is only enabled after a total, partial or step-by-step opening com­mand.
TM
10 s 120 s
60 s
Operation time adjustment. From 10 to 120 s.
NOTE: set TM=MAX with limit switches installed.
LED On Flashing
SIG
Transmitter enablinJ/storaJe phase. Reception of a radio transmission.
Cancellation of transmitters in proJress. BIXMR2 memor\ damaJed.
IN
11
12
Receipt of command or chanJe in status of a dip-switch. 0-11 limit switch contact is open.
0-12 limit switch contact is open.
/
/
/
SA At least one of the safet\ contacts is open. Operations count performed (onl\ when con-
trol panel is switched on): each rapid Àash = 1000 operations each slow Àash = 10000 operations
POWER Power suppl\ on.
/
IP1935EN 2010-07-19
8
Page 9
8. RADIO RECEIVER OPERATION
N
The control panel is eTuipped with a radio receiver with a freTuenc\ of 433.92 MH]. The antenna consists of a 173 mm lonJ riJid wire. It is possible to increase the ranJe of the radio b\ connectinJ the external antenna of the ÀashinJ liJhts, or b\ installinJ the tuned antenna (BIXAL).
NOTE: to connect the external antenna to the control panel, use a coaxial cable type RG58 (max 10 m).
Up to 200 remote controls can be stored in the BIXMR2 storaJe module.
WARNING: if the radio receiver on the control panel is not used, set JR1=OFF and remove the storage mo­dule.
Refer to the transmitters user manual to store, clone and delete transmitters. From one to four CH Ne\s of a sinJle transmitter can be stored in the control panel. If onl\ one (an\) CH Ne\ of the transmitter is stored, command 1-5 (step-b\-step/openinJ) is carried out. If from two to four CH Ne\s of a sinJle transmitter are stored, the functions matched with the CH Ne\s are as follows:
- CH1 = command 1-5 step-b\-step/openinJ;
- CH2 = partial openinJ command, it causes the automation to open for about 8 s;
- CH3 = command to switch on/off the courtes\ liJht;
- CH4 = stop command, eTuivalent to impulsive command 1-9. If the control panel is replaced, the BIXMR2 storaJe module beinJ used can be inserted in the new control panel.
WARNING: the BIXMR2 storage module must be inserted and removed with the power supply disconnected.
9. START-UP
WARNING The operations in point 5 are performed without safety devices.
NI
The trimmer can only be adjusted with the automation idle.
1- MaNe a jumper for the N.C. safet\ contacts. 2- ChecN the application t\pe selected. 3- If installed, adjust the openinJ and closinJ stop limit switches.
NOTE: limit switches must be kept pressed until the operation has been completed.
4- Set TR!3 s in case of automation with two overlappinJ door winJs. 5- Switch on and checN that the automation is operatinJ correctl\ with subseTuent openinJ and closinJ
commands.
If installed, checN that the limit switches are activated.
NOTE: if the direction of rotation of the motor is incorrect for the desired direction of the automation, swap
the U-V or X-Y phases.
6- Connect the safet\ devices (removinJ the relative jumpers) and checN the\ worN correctl\. 7- If reTuired, adjust the automatic closinJ time with the TC trimmer.
WARNING: the automatic closing time after a safety device has triggered depends on the DIP2A setting. 8- Set RF trimmer to a position that allows the automation to function correctl\ while ensurinJ the safet\ of
the user in the event of collision.
9- Set the obstacle thrust with the R1 trimmer.
NOTE: if the door wing closing second encounters an obstacle, both door wings are reopen and the sub-
sequent closing operation is performed one door wing at a time.
WARNING: check that the working forces exerted by the door wings are compliant with EN12453-EN12445
regulations.
10- Connect an\ other accessories and checN the\ operate correctl\. 11- Once the start-up and checN procedures are completed, close the container.
The operations in point 5 are performed without safety devices. The trimmer can only be adjusted with the automation idle.
NOTE: in the event of servicing or if the control panel is to be replaced, repeat the start-up procedure.
i
9
IP1935EN 2010-07-19
Page 10
10. TROUBLESHOOTING
Problem Possible causes Remedy
The automation does not open or close.
The automation opens but does not close.
The automation is ver\ weaN and does not invert the movement. External safet\ devices not activatinJ.
The remote control has li­mited ranJe and does not worN with the automation movinJ.
No power. (POWER led off). Short circuited accessories. (POWER led off).
Blown line fuse. (POWER led off). Safet\ contacts are open. (SA led on). The remote control does not worN. ChecN the correct memori]ation of the
Safet\ contacts are open. (SA led on). Photocells are activated. (SA led on). The automatic closinJ does not worN. ChecN that the TC trimmer is not set at
The motor’s condenser has an incor­rect capacit\ value.
Incorrect connections between the photocells and the control panel.
The radio transmission is impeded b\ metal structures and reinforced con­crete walls.
ChecN that the control panel is powe­red correctl\. Disconnect all accessories from termi­nals 0-1 (voltaJe must be 24 V=) and reconnect one at a time. Replace F1 fuse.
ChecN that the safet\ contacts are clo­sed correctl\ (N.C.).
transmitters on the incorporated radio. If there is a fault with the radio receiver that is incorporated in the control panel, the radio control code can be read b\ removinJ the storaJe module. ChecN that the safet\ contacts are clo­sed correctl\ (N.C.). ChecN that the photocells are clean and operatinJ correctl\.
the maximum. Replace the motor’s condenser.
Connect N.C. safet series and remove an\ bridJes on the control panel terminal board. Install the antenna outside. Substitute the transmitter batteries.
\ devices toJether in
IP1935EN 2010-07-19
10
Page 11
11. EXAMPLE APPLICATION FOR GATES WITH ONE SWINGING DOOR WING
When the control panel is used in applications with one swinJinJ door winJ, one of the followinJ operatinJ modes ma\ be selected:
(Fig. 11.1) Door wing stops against mechanical stops and in the event of obstacle detection.
Set an operatinJ time of 2-3 s lonJer than the ef­fective time taNen b\ the door winJ (TMMAX) and bridJe terminals 0-11-12 with jumpers. In this con¿Juration, the door winJ will stop aJainst mechanical openinJ and closinJ stops and in the event of obstacle detection.
(Fig. 11.2) Door wing stops against limit switches and in the event of obstacle detection.
The N.C. contacts of the openinJ and closinJ limit switches are connected in series with the motor phases. Set an operation time TMMAX and bridJe terminals 0-11-12 with jumpers. In this con¿Juration, the door winJ stops aJainst the openinJ and closinJ limit switches and in the event of obstacle detection.
(Fig. 11.3) Door wing stops against limit switches and inverts in the event of obstacle detection.
Set an operatinJ time TM=MAX and connect the openinJ and closinJ limit switches N.C. contacts to terminals 0-11-12. In this con¿Juration, the door winJ stops when the limit switches are activated. In the event of obstacle detection while openinJ, the door winJ stops, perfor­minJ a disenJaJement operation, whereas durinJ a closin
J operation, the door winJ reopens.
R1<MAX
TM<MAX
R1<MAX
TM<MAX
Limit switch (230V - 5A)
R1<MAX
TM=MAX
B
ON
OFF
123 4 5 6
A
ON
OFF
123 4
R1 TM
15 13 12 11 0 1 15689
B
ON
OFF
123 4 5 6
A
ON
OFF
123 4
A
123 4
UWV
com
230V~
Motor 1
R1 TM
R1 TM
15 13 12 11 0 1 15689
B
ON
OFF
123 4 5 6
ON
OFF
DIP3B=OFF
FiJ. 11.1
DIP3B=OFF
FiJ. 11.2
DIP3B=OFF
11
15 13 12 11 0 1 15689
Closing limit switch
Opening limit switch
IP1935EN 2010-07-19
FiJ. 11.3
Page 12
(Fig. 11.4) Door wing stops against mechanical stops and inverts in the event of obstacle detection.
Set an operatinJ time of 2-3 s lonJer than the ef­fective time taNen b\ the door winJ (TMMAX) and position the proximit\ limit switches 2-3 s ahead of the mechanical stop. In this con¿Juration, the door winJ stops aJainst its respective mechanical closinJ and openinJ stop. In the event of obstacle detection before the acti­vation of the proximit\ limit switch while openinJ, the door winJ stops, performinJ a disenJaJement operation; after the proximit\ limit switch is activated, the door winJ stops aJainst the obstacle. In the event of obstacle detection while closinJ and before the activation of the proximit\ limit switch, the door winJ reopens; after the proximit\ limit switch is activated, the door winJ stops aJainst the obstacle.
R1<MAX
TM<MAX
B
ON
OFF
123 4 5 6
A
ON
OFF
123 4
R1 TM
15 13 12 11 0 1 15689
DIP3B=OFF
(Fig. 11.5) Door wing stops against the limit switch when opening and against the mechanical stop when closing, and inverts in the event of obstacle detection.
Set an operatinJ time 2-3 s lonJer than the effective time taNen b\ the door winJ (TMMAX), and the closinJ proximit\ switch 2-3 s earlier than the mecha­nical stop and connect the N.C. openinJ limit switch in series to the openinJ phase of the motor. In this con¿Juration the winJ
stops on the closinJ mechanical stop while on the openinJ, it stops and releases when the relative limit switch operates. DurinJ openinJ operation, in the event of obstacle detection, the winJ stops, performinJ a disenJaJe- ment operation. DurinJ closinJ operation, in the event of obstacle detection before the proximit\ switch operates, the winJ reopens; after the proximit\ switch operates, the winJ stops on the closinJ mechanical stop.
R1<MAX TM<MAX
Opening
limit switch
(230V - 5A)
Closing proximity switch
Opening proximity switch
R1 TM
UWV
15 13 12 11 0 1 15689
com
230V~
Motor 1
B
ON
OFF
123 4 5 6
ON
OFF
FiJ. 11.4
DIP3B=OFF
A
123 4
IP1935EN 2010-07-19
12
Closing proximity switch
FiJ. 11.5
Page 13
12. EXAMPLE APPLICATION FOR GATES WITH TWO SWINGING DOOR WINGS
TR>3 s
R1<MAX
When the control panel is used in applications with two overlappinJ swinJinJ door winJs, one of the followinJ operatinJ modes ma\ be selected:
(Fig. 12.1) Door wings stop against mechanical stops and in the event of obstacle detection.
Set an operatinJ time of 2-3 s lonJer than the ef­fective time taNen b\ the door winJs (TMMAX) and bridJe terminals 0-11-12 with jumpers. In this con¿Juration, each door winJ will stop aJainst mechanical openinJ and closinJ stops and in the event of obstacle detection.
(Fig. 12.2) Door wings stop against limit switches and in the event of obstacle detection.
The N.C. contacts of the openinJ and closinJ limit switches are connected in series with the motor phases. Set an operatinJ time TMMAX and bridJe terminals 0-11-12 with jumpers. In this con¿Juration, each door winJ will stop aJainst the openinJ and closinJ limit switches and in the event of obstacle detection.
(Fig. 12.3) Door wings stop against limit switches and invert in the event of obstacle detection.
Set an operatinJ time TM=MAX and connect the clo­sinJ limit switch N.C. contacts to terminals 0-11-12 and the openinJ limit switch N.C. contacts in series with the open phase of each motor. In this con¿Juration, each door winJ stops when the limit switches are activated. In the event of obstacle detection while openinJ, onl\ the door winJ that detects the obstacle stops, perfor­min
J a disenJaJement operation, whereas durinJ a
closinJ operation, both door winJs reopen.
TM<MAX
UWV
(230V - 5A)
Limit switch
230V~
Motor 1
UWV
(230V - 5A)
TR R1 TM
15 13 12 11 0 1 15689
TR>3 s
R1<MAX
com
com
TM<MAX
XZY
com
230V~
Motor 2
TR>3 s
R1<MAX
TM=MAX
XZY
com
TR R1 TM
15 13 12 11 0 1 15689
TR R1
15 13 12 11 0 1 15689
FiJ. 12.1
FiJ. 12.2
TM
Opening limit switch
13
230V~
Motor 1
230V~
Motor 2
Closing limit switch
Closing limit switch
IP1935EN 2010-07-19
FiJ. 12.3
Page 14
(Fig. 12.4) Door wings stop against mechanical stops and invert in the event of obstacle detection.
Set an operatinJ time 2-3 s Jreater than the effective time taNen b\ the door winJs (TMMAX) and connect the closinJ proximit\ switch N.O. contacts to termi- nals 0-11-12, positioninJ the proximit\ switches 2-3 s ahead of the mechanical stop. In this con¿Juration, each door winJ stops aJainst its respective mechanical closinJ and openinJ stop. In the event of obstacle detection while openinJ, onl\ the door winJ that detects the obstacle stops, performinJ a disenJaJement operation. In the event of obstacle detection durinJ closinJ and before the activation of the proximit\ switch, the door winJs reopen; after the activation of the proximit\ switch, the door winJs stop aJainst the obstacle.
TR>3 s
R1<MAX
TM<MAX
TR R1 TM
15 13 12 11 0 1 15689
(Fig. 12.5) Door wings stop against the limit switches when opening and against the mechani­cal stops when closing, and invert in the event of obstacle detection.
Set an operatinJ time 2-3 s lonJer than the effective time taNen b\ the door winJs (TMMAX), connect the closinJ proximit\ switches to terminals 0-11-12 and set them 2-3 s earlier than the mechanical stops. Connect the N.C. openinJ limit switch in series to the openinJ phase of each motor. In this con¿Juration, each win
J stops on its closinJ mechanical stop and durinJ openinJ when the rela­tive limit switches operate. DurinJ openinJ operation, in the event of obstacle detection, the winJ stops and releases. DurinJ closinJ operation, in the event of obstacle detection before both the closinJ limit switches have been triJJered, both winJs reopen. After each limit switch has been triJJered the cor­respondinJ winJ stops on the closinJ mechanical stop.
UWV
(230V - 5A)
Opening limit switch
230V~
Motor 1
XZY
com
230V~
Motor 2
Closing proximity switch
Closing proximity switch
TR>3 s
R1<MAX
TM<MAX
TR R1
15 13 12 11 0 1 15689
com
Closing proximity switch
Closing proximity switch
FiJ. 12.4
TM
FiJ. 12.5
IP1935EN 2010-07-19
14
Page 15
13. HOLD-TO-RUN FUNCTION MODE
NOTE: to use the control panel in hold-to-run
NOTE: to use the control panel in hold-to-run
i
ode, disconnect terminal 9.
mode, disconnect terminal 9.
In this case, the openinJ command (1-5) and the closinJ command (1-6) operate onl\ if Nept pressed, if released the automation will stop. Automatic closinJ and radio remote controls are disabled.
R1<MAX TM=MAX
B
ON
OFF
123 4 5 6
A
ON
OFF
R1 TM
123 4
15 13 12 11 0 1 15689
Closing limit switch
Opening limit switch
DIP5B=OFF
DIP1A=ON
FiJ. 13.1
15
IP1935EN 2010-07-19
Page 16
TM
DITEC S.p.A. Via Mons. Ban¿, 3 21042 Caronno P.lla (VA) Ital\ Tel. +39 02 963911 Fax +39 02 9650314
www.ditec.it ditec@ditecva.com
DITEC BELGIUM LO.EREN Tel. +32 9 3560051 Fax +32 9 3560052 www.ditecbelJium.be DITEC DEUTSCHLAND OBERURSEL Tel. +49 6171 914150 Fax +49 6171 9141555 www.ditec-Jerman\.de DITEC ESPAÑA ARENYS DE MAR Tel. +34 937958399 Fax +34 937959026 www.ditecespana.com DITEC FRANCE MASSY Tel. +33 1 64532860 Fax +33 1 64532861 www.ditecfrance.com DITEC GOLD PORTA ERMESINDE-PORTUGAL Tel. +351 22 9773520 Fax +351 22 9773528/38 www.Joldporta.com DITEC SVIZZERA BALERNA Tel. +41 848 558855 Fax +41 91 6466127 www.ditecswiss.ch DITEC ENTREMATIC NORDIC LANDSKRONA-SWEDEN Tel. +46 418 514 50 Fax +46 418 511 63 www.ditecentrematicnordic.com DITEC TURCHIA ISTANBUL Tel. +90 21 28757850 Fax +90 21 28757798 www.ditec.com.tr DITEC AMERICA ORLANDO-FLORIDA-USA Tel. +1 407 8880699 Fax +1 407 8882237 www.ditecamerica.com DITEC CHINA SHANGHAI Tel. +86 21 62363861/2 Fax +86 21 62363863 www.ditec.cn
Loading...