HIGH SENSITIVITY MICROPOWER
UNIPOLAR HALL-EFFECT SWITCH
Description
The AH3360 is a high sensitivity micropower Unipolar Hall effect
switch IC with internal pull up and pull down capability. Designed for
battery powered consumer such as cellular phones and portable PCs
to home appliance and industrial equipment, the average supply
current is only 4.3uA at 1.85V. To support portable equipment the
AH3360 can operate over the supply range of 1.6V to 3.6V and uses
a hibernating clocking system to minimize the power consumption. To
minimize PCB space the AH3360 is available in small low profile
SOT553, X1-DFN1216-4 and X2-DFN2015-6 and packages.
The output is activated with a south pole of sufficient magnetic field
strength. When the magnetic flux density (B) perpendicular to the
package is larger than operate point (Bop), the output will be turned
on (pulled low) and held until B is lower than release point (Brp). The
output will remain off when there is no magnetic field.
Features
Unipolar Operation (South pole to part marking side)
NEW PRODUCT
Supply Voltage of 1.6V to 3.6V
High Sensitivity
Micropower Operation
Chopper Stabilized Design Provides:
Superior Temperature Stability
Minimal Switch Point Drift
Enhanced Immunity to Physical Stress
No External Pull-up Resistors Required
Good RF Noise Immunity
-40°C to +85°C Operating Temperature
High ESD capability of 8kV Human Body Model
Small Low Profile X1-DFN1216-4, X2-DFN2015-6 and SOT553
Packages
Totally Lead-Free & Fully RoHS Compliant (Notes 1 & 2)
Halogen and Antimony Free. “Green” Device (Note 3)
Notes: 1. No purposely added lead. Fully EU Directive 2002/95/EC (RoHS) & 2011/65/EU (RoHS 2) compliant.
2. See http://www.diodes.com/quality/lead_free.html for more information about Diodes Incorporated’s definitions of Halogen- and Antimony-free, "Green"
and Lead-free.
3. Halogen- and Antimony-free "Green” products are defined as those which contain <900ppm bromine, <900ppm chlorine (<1500ppm total Br + Cl) and
<1000ppm antimony compounds.
Pin Assignments
( Top View )
1
V
DD
2
NC
3
NC
X2-DFN2015-6
Applications
Open and Close Detect for Cellular Phones
Holster or Cover Detect for Cellular Phones and Tablet PCs
Cover or Display Switch in Portable PCs
Digital Still, Video Cameras and Handheld Gaming Consoles
Docking Station Detect
Door, Lids and Tray Position Switches
Level, Proximity and Position Switches
Contact-Less Switches in Home Appliances and Industrial
Applications
Typical Applications Circuit
H3360
6
5
4
OUTPUT
NC
GND
Note: 4. C
is for power stabilization and to strengthen the noise immunity, the recommended capacitance is 100nF typical.
IN
AH3360
Document number: DS35744 Rev. 1 - 2
1 of 11
www.diodes.com
August 2013
© Diodes Incorporated
Pin Descriptions
Package: X1-DFN1216-4
Pin Number Pin Name Function
1 OUTPUT Output Pin
2
3 NC No Connection (Note 5)
4
Package: X2-DFN2015-6
Pin Number Pin Name Function
1
2 NC No Connection (Note 5)
3 NC No Connection (Note 5)
4 GND Ground Pin
5 NC No Connection (Note 5)
6 OUTPUT Output Pin
NEW PRODUCT
Package: SOT553
Pin Number Pin Name Function
1
2 NC No Connection (Note 5)
3 NC No Connection (Note 5)
4 GND Ground Pin
5 OUTPUT Output Pin
Note: 5. NC is “No Connection” pin and is not connected internally. This pin can be left open or tied to ground.
V
DD
GND Ground Pin
V
DD
V
DD
Power Supply Input
Power Supply Input
Power Supply Input
Functional Block Diagram
H3360
AH3360
Document number: DS35744 Rev. 1 - 2
2 of 11
www.diodes.com
August 2013
© Diodes Incorporated
H3360
Absolute Maximum Ratings (Note 6) (@T
Symbol Parameter Rating Unit
VDD
V
DD_REV
I
OUTPUT
B Magnetic Flux Density Unlimited
PD
Ts Storage Temperature Range -65 to +150 °C
TJ
ESD HBM Human Body Model (HMB) ESD Capability 8 kV
Notes: 6. Stresses greater than the 'Absolute Maximum Ratings' specified above may cause permanent damage to the device. These are stress ratings only;
functional operation of the device at these or any other conditions exceeding those indicated in this specification is not implied. Device reliability may be
affected by exposure to absolute maximum rating conditions for extended periods of time.
7. The absolute maximum V
operate the device at the absolute maximum rated conditions for any period of time.
Supply Voltage (Note 7) 6 V
Reverse Supply Voltage -0.3 V
Output Current (source and sink) 3 mA
Package Power Dissipation
Maximum Junction Temperature 150 °C
of 6V is a transient stress rating and is not meant as a functional operating condition. It is not recommended to
DD
Recommended Operating Conditions (@T
NEW PRODUCT
Symbol Parameter Conditions Rating Unit
VDD
TA
Electrical Characteristics (@T
Symbol Parameter Conditions Min Typ Max Unit
VOL Output Lo w Voltage (on) I
VOH Output High Voltage (off) I
Ioff Output Leakage Current V
IDD(awake)
IDD(sleep)
IDD(avg)
Tawake Awake Time (Note 8)
Tperiod Period (Note 8)
D.C. Duty Cycle
Notes: 8. When power is initially turned on, the operating VDD (1.6V to 3.6V) must be applied to guaranteed the output sampling.
The output state is valid after the second operating cycle (typical 100ms).
Supply Voltage Operating 1.6V to 3.6V V
Operating Temperature Range Operating -40 to +85 °C
= +25°C, VDD = 1.85V, unless otherwise specified.)
A
Supply Current
Average Supply Current
= +25°C, unless otherwise specified.)
A
X1-DFN1216-4, X2-DFN2015-6 230 mW
SOT553 230 mW
= +25°C, unless otherwise specified.)
A
= 1mA — 0.1 0.2 V
OUT
= -1mA V
OUT
= 3.6V, Output off — < 0.1 1 µA
OUT
During ‘awake’ period,
T
= +25°C, VDD = 3V
A
During ‘sleep’ period,
= +25°C, VDD = 3V
T
A
= +25°C, VDD = 1.85V
T
A
TA = +25°C, VDD = 3.6V
-0.2 V
DD
—
—
2.5 — mA
—
—
—
—
—
-0.1 — V
DD
2.1
4.3 8 µA
7.2 13 µA
50 100 µs
50 100 ms
0.1 — %
—
mA
AH3360
Document number: DS35744 Rev. 1 - 2
3 of 11
www.diodes.com
August 2013
© Diodes Incorporated
H3360
Magnetic Characteristics (Note 9 &10) (T
Symbol Characteristics Test Condition Min Typ Max Unit
Bops (south pole to part marking side) Operation Point
Brps (south pole to part marking side) Release Point
Bhy (|Bopx|-|Brpx|) Hysteresis (Note 11)
Notes: 9. Typical data is at TA = +25C, VDD = 1.85V.
10. Maximum and minimum parameters values over operating temperature range are not tested in production, they are guaranteed by design, process
control and characterization. The magnetic characteristics may vary with supply voltage, operating temperature and after soldering.
11. Maximum and minimum hysteresis is guaranteed by design and characterization.
= 25°C, VDD = 1.85V, unless otherwise specified)
A
= +25°C 16 30 42
T
A
TA = -40°C to +85°C 14 30 46
= +25°C 11 20 35
T
A
TA = -40°C to +85°C 9 20 39
T
= +25°C 5 10 15
A
TA = -40°C to +85°C 3 10 17
(1mT=10 Gauss)
Gauss
NEW PRODUCT
AH3360
Document number: DS35744 Rev. 1 - 2
4 of 11
www.diodes.com
August 2013
© Diodes Incorporated