Dinex IDT1C Service Manual

Cantilev er Tray & Rack Dispensers
Models IDRC,IDT1C,IDT2C,IDTS1C & IDTS2C
DINEX INTERNATIONAL,INC. • 628-2 HEBRON AVENUE,GLASTONBURY CT 06033 • WWW.DINEX.COM
Introduction . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 2
Unpack & Set-up . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 2
Spring Calibration . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 2
Cleaning. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 3
Dinex® Warranty. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 3
Replacement Parts. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 4
Please provide following information:
• Model number
• Serial number
• Part Description and number as shown in parts list.
Manual No. TRD-C Rev-10/02
Service Manual
Model: IDRC Model: IDT1C
Model: IDTS1C
Printed in the USA
Page 2
Introduction:
Installation:
Congratulations:You have just purchased one of the finest pieces of equipment on the market today.Before installing or operating our new Dinex® Products equipment you should read through this material.This manual should be retained for further reference as it contains installation and operating instructions,service tips,part list and warranty information.Should you have any questions concerning the Equipment,please call the Dinex Hotline at 1-888-673­4639 (Monday through Friday from 8 am to 5 pm,Eastern Standard Time).
IMPORTANT: For your safety,read and follow all cautions, information and warnings
FREIGHT DAMAGE CLAIMS
Your Dinex® Products equipment was carefully inspected and packed before leaving our factory. The transpor tation company assumes full responsibility for safe delivery of this equipment.Dinex® Products cannot assume responsi­bility for damage or loss incurred in transit.Visible damage or loss should be noted on freight bill and signed by person making delivery.
A freight claim should be filed immediately with the trans­portation company.If damage is unnoticed or concealed until equipment is unpacked,notify the transportation company immediately and tell them you want to file a concealed damage claim.This must be done within fifteen (15) days after delivery was made.Be sure to retain all
packing material and cartons.
WARNING:Installation of this equipment should be performed only by persons qualified or licensed to install electrical equipment.
• Adjustments and service work should be performed only by a qualified service technician.S er vice is available through Authorized Dinex® Products Parts & Service Distributors throughout the United States.For a complete listing of these consult your distributor listing or write Dinex® Products for the name of the nearest distributor.
• This equipment in intended for commercial use only. Not for household use.
• Use of other than genuine Dinex® Products replace­ments parts or service work performed by other than authorized Dinex® Products service agents will void the warranty.
• Do not use any corrosive cleaners.Use only cleaners approved for stainless steel.
SECTION 1 - UNPACK & SET-UP
Be careful to inspect your dispenser for any damage as you are unpacking.Remove all protective tape and pack­ing materials.
Make sure parts are properly assembled before loading with trays or racks.Install carrier by setting “L”shaped arms on round bars through the vertical slots in the pylon (Figure 1).
Engage top round bar by lifting front of carrier about 4” and sliding top of arms back into pylon.Now,lower front of carrier and top of arms should engage upper round bar and retain the carrier in place.I t travels smoothly up and down.Begin loading the dispenser with the trays or racks you wish to dispense.As you are loading observe the level being maintained by the dispenser.The top of the stack should remain at a convenient height as you add to or remove from the stack,if so,your dispenser is ready to use. If the stack does not stay at a convenient height,that is the top climbs to an excessive height or falls to an inconven­ient level,you will need to calibrate the dispenser to match the load.Follow the calibration instructions below.
SECTION 2 - CALIBRATION
1.Remove carrier assembly by lifting front up and away from pylon,as shown in Figure 1a.
!
!
Figure 1
Figure 1a
Loading...
+ 2 hidden pages