Installation and Operating Instructions
INDPUKP5RG Issue 3
PLX Panel Convector Heaters
Dimensions
(millimetres)
Model(s) Watt A B
PLX 500/NC/TI/WTI 500 450 108 PLX 625/NC 625 688 108 PLX 750/NC/TI 750 620 108 PLX 1000/NC/TI/WTI 1000 620 108 PLX 1250/NC/TI 1250 688 108 PLX 1500/NC/TI/WTI 1500 688 108 PLX 2000/NC/TI/WTI/TX 2000 860 108 PLX 3000/TI/TX 3000 860 143
Important Safety Advice
When using electrical appliances, basic precautions should always be followed to reduce the risk of fire, electrical shock, and injury to persons, including the following: IMPORTANT – If the heater is installed in a room containing a bath or shower , it must be so installed that switches and other controls cannot be touched by a person using a bath or shower. WARNING - DO NOT USE THIS HEA TER IN THE IMMEDIA TE SURROUNDINGS OF A BA TH, A SHOWER OR A SWIMMING POOL. Do not use outdoors. Do not locate the heater immediately below a fixed socket outlet or connection box. Do not cover the heater. NEVER cover or obstruct in any way the heat outlet slots at the top of the heater or the air inlet slots in the base of the heater. Do not place material or garments on the heater, or obstruct the air circulation around the heater, for instance by curtains or pushing furniture up against the heater, as this could cause overheating and a fire risk.
The heater carries the Warning symbol indicating
that it must not be covered. WARNING – THE SURF ACES OF THIS HEATER CAN BE HOT . Momentary contact with any part of the heater should not cause injury. However, aged or infirm persons or young children should not be left unsupervised in the vicinity of the heater unless a suitable guard is fitted. This appliance is not intended for use by children or other persons without assistance or supervision if their physical, sensory or mental capabilities prevent them from using it safely. Children should be supervised to ensure that they do not play with the appliance. Note that due care and consideration must be taken when using this heater in series with a thermal control, a program controller, a timer or any other device that switches on the heat automatically, since a fire risk exists when the heater is accidentally covered or displaced. If the supply cord is damaged it must be replaced by the manufacturer or service agent or a similarly qualified person in order to avoid a hazard.
WARNING: Servicing & product repairs should only be undertaken by the manufacturers approved service agent or a similarly qualified person, using only exact manufacturer approved spare parts.
Fig. 1
IMPORTANT: THESE INSTRUCTIONS SHOULD BE READ CAREFULL Y AND RET AINED FOR FUTURE REFERENCE
A
150 MIN
‘x’
150 MIN
150 MIN
B
430
Electrical
WARNING – THIS APPLIANCE MUST BE EARTHED
The electrical installation must be carried out by a competent electrician, and be in strict accordance with the current I.E.E. regulations for Electrical Equipment in Buildings.
The heater is fitted with a length of flexible cable type H05VV­F size 3 x 1.0mm
2
on models PLX 500 - 2000 and size 3 x
1.5mm2 on PLX 3000 models, for connection to the fixed wiring of the premises through a suitable connection box positioned adjacent to the heater.
The supply circuit to the heater must incorporate a double pole isolating switch having a contact separation of at least 3mm.
Supplementary Earth Bonding
Should Equipotential Earth Bonding be required the earthing conductor in the supply cord is deemed to provide the supplementary bonding connection (see Regulation 544.2.5, 17
th
Edition I.E.E. Wiring Regulations).
General
NOTE: The PLX Convector is designed for wall mounting on the wall brackets supplied. The wall brackets supplied with the appliance must be used. It should only be operated when in the upright position as shown. All models are splashproof to IP24 standard. Models PLX…TI are fitted with a 24 hour programmable timer. Models PLX…TX are fitted with a 7 Day programmable timer. Models PLX…NC are fitted with no controls, for use with external thermostatic or programming controllers. Before connecting the heater check that the supply voltage is the same as that stated on the heater.
Please note that lit cigarettes, candles and oil burners, combined with the convection effect of electric heaters can cause soot deposits to build up on the surface directly above and to the sides of the heater. This is not the fault of the heater. Extensive burning of candles or smoking in the operating environment of this product can produce heavy discoloration within a few months of use.