Dimplex GDH-DEH30E Owner's Manual

CONTENTS
GDH-DEH30E
DEHUMIDIFIER
OWNERSMANUAL
VOLTAGE 220-240V/50Hz
Comfort. By Design
30L
CASTORS
WATER STORAGE TANK
OUTLET FOR DEHUMIDIFIED AIR
HANDLE
CONTROL PANEL
CONTINUOUS DRAINAGE OUTLET
AIR INLET
AIR FILTER
- 2 -
DESCRIPTION OF COMPONENTS
FUNCTION EXPLANATION
DEFROST LAMP
When temperature is low, unit goes into defrosting mode
BUCKET FULL INDICATOR
Water tank is full,when lit
FAN SPEED
High / Low
TIMERS
When unit is on, press "TIMER"to set hours the unit will run before shutting off When unitisonstand-by, press "TIMER" set hoursuntilunit will turn on. Time1~24 hours. To cancel the timer, proceed as above but set the "timer off" to zero hours.
POWER
On / Off
When machine is running, it displays the current temperature. Press the "Timer" button to set the machine to shut off automatically after a specified amount of time. 10 seconds after displaying the timer, the display will change back to current temperature.
CURRENT TEMP / TIMER SET DISPLAY
When machine is running, it displays the current humidity. Press " " or " " to select humidity setting. The humidity is adjusted in an increment of 5% by each pressing of " " or " ". Adjustable range is within 30%RH to 90%RH. 10seconds after setting humidity, the display will change back to the current humidity.
SET HUMIDITY / CURRENT HUMIDITY DISPLAY
Press the switch buttons, it will switch at sequence of
andF.
C/F
C
°
°
60% RH is
recommended
OPERATING INSTRUCTIONS
- 3 -
Please use both hands to carefully empty the water tank.
DEFROST
Operation
1) Place the product in an upright position onaflat, steady, stable, heat-resistant surface. Make sure there is nothing flammable or heat sensitive within 100 cm . Operating the product in any other position could be hazardous.
2) Insert the plug into a suitable wall socket. The dehumidifier is suitable for operation on an electricity supply of the same voltage as that shown on its rating label.
3) Make sure the water tank is correctly located. (After switching on the machine for the first time, if the "Bucket Full" lamp illuminates, just pull out the water tank, check the "float" lever is able to move freely, then ret
urn the water
tank to the correct position.)
When Bucket Full Lamp Is On
When the water tank is full the machine will stop and the "Bucket Full" light will illuminate. The water tank should be carefully removed from the machine by sliding it outwards from the front of the machine and it should be emptied. When the empty tank is replaced properly into the machine, the machine will start up and run normally.
When the machine is operated at low temperatures (less than 12°C) the surface of the evaporator may accumulatealayer of frost which would reduce the efficiency of the machine. When this happens the machine will go into periodic defrost mode. The defrost symbol on
the LCD display will come on. The machine will operate in temperatures down to 5 . The time taken to defrost may vary. If the machine freezes up, it should be turned off at the power supply and re-started. If the room temperature remains below 5 the machine should be switched off.
°C.
°C
Loading...