Dimplex BRTU 101 UN Operating Instructions And System Description

Stand 11.2011 1
Operating Instructions for
Universal Temperature Controller
BRTU 101 UN
2
3
11. Safety information . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 04
12. Application / functional description / emergency operation . . . . . 05
13. Operating instructions . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 06
14. Control operation . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 07
14.1 Temporary set temperature setting . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 08
14.2 Selection of the operating mode . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 09
15. Main menu . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 10
15.1 Submenu “Party” . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 12
15.2 Setting of the holiday data . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 13
15.3 Setting of the time . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 18
15.4 Setting of the date . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 20
15.5 Setting of the set temperatures . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 23
15.6 Entry of the weekday programs . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 25
15.7 Information . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 29
15.8 Settings . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 30
16. Experts menu . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 33
17. Mounting / connection . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 35
18. Wiring diagram and dimensioned drawing . . . . . . . . . . . . . . . . . . . . . 36
19. Technical data . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 38
10. Accessories . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 39
11. Warranty . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 39
4
Expert electricians only may open this device in due compliance with the wiring diagram shown in the housing cover / on the housing / represented in the corresponding operating instructions. All expert electricians charged with the execution of such works must comply with the relevant safety regu­lations currently operative and in force. Caution: The operation of the con­troller in the vicinity of other devices that do not comply with the EMC direc­tives may affect its functions. The company charged with the installation of the device must, after the completion of the installation works, instruct the user of the control system into its functions and in how to operate it correctly. These operating instructions must be kept at a place that can be accessed freely by the operating and/or servicing personnel in charge.
1. Safety information
5
The controller described in these instructions is provided for flush installa­tion and has been specially devised for the time-dependent control of the temperatures in individual rooms or of the temperatures produced by elec­tric or warm-water heating systems (systems with normally closed valve actuators). The device can be used as floor or as room temperature controller with additional floor temperature controller function. Operation in emergency mode is triggered if the internal or external sensor is defective. The same applies if no sensor has been connected when using the device as room temperature controller with additional floor monitoring function and also when using it as floor temperature controller. An error message appears on the display and an indicator lamp starts blinking red to indicate this condi­tion. During operation in emergency mode a fixed 30% duty cycle is being maintained to prevent the related room from cooling down thoroughly and protect it against frost damage. The activation time divides into a 3-minute ACTIVE and a 7-minute OFF time.
2. Application / functional description / emergency operation
6
The device is equipped with 4 touch keys, all of which have been marked by the symbol . The functions allocated to them may vary in dependence on the operation requirements. The related function is being indicated on the display which exists above the corresponding keys. A special protective function helps prevent an inadvertent activation of the touch keys. This function is activated 20 seconds after any of the touch keys has last been activated. Actuating any of the touch keys deactivates this function again for 2 seconds.
3. Operating instructions
0
7
4. Control operation
Temporary set temperature setting
see 4.1
Selection of the operating mode
see 4.2
Main menu
see 5.
Temporary set temperature setting
see 4.1
8
4.1 Temporary set temperature setting
Set temperature – 0.5 K
Acquisition of the values
Return to normal control mode
Set temperature + 0.5 K
If no key has been activated within a period of approx. 5 seconds, the system returns to normal control mode again. The changed temperature value is being taken over and imported. The adjusted set temperature con­tinues to be effective until the moment the operating mode is changed, no matter if changing manually or automatically after triggering by the switch clock.
9
4.2 Selection of the operating mode
Actuating the touch key “Mode” allows to change the operating mode in the order shown below: – Automatic mode (in compliance with the related weekday mode settings) – Comfort mode, permanently – ECO mode, permanently – Operating mode “OFF”
In “OFF” mode, the controller activates the heating when underrunning a temperature level of approx. 5°C and deactivates the operations when exceeding a temperature level of approx. 6°C. This antifreezing function helps prevent rooms from cooling down thoroughly and protects against the occurrence of frost damage.
10
5. Main menu
Actuating the key terminates the main menu.
Submenu
Party
see 5.1
Submenu
Holiday
see 5.2
Submenu
Time
see 5.3
Submenu
Date
see 5.4
11
5. Main menu
Submenu
“temperature”
see 5.5
Submenu “weekday
programs”
see 5.6
Info function
see 5.7
Submenu
“settings”
see 5.8
Calling of the
experts menu
see 6.
12
5.1 Submenu “Party”
Party end – 15 minutes
Termination of data entry,
returning to the main menu
Start of the “Party” function
Party end + 15 minutes
Actuating the touch key starts the party function. Once the pre­adjusted time has been attained, the system switches automatically back to the previous operating mode. Actuating the touch key cancels the party function at any time. While operating in party mode, all control operations are performed in dependence on the actually adjusted comfort temperature.