Dimensions
(millimetres)
Models Specification
DXLWP400 400W Neon Heat Switch
DXLWP800 800W Neon Heat Switch
DXLWP800TI N 800W Neon Heat Switch / 24 Hour Timer
ARLWP800TI 800W 2 Neon Heat Switches / 24 Hour Timer
THESE INSTRUCTIONS SHOULD BE READ CAREFULLY AND RETAINED FOR FUTURE REFERENCE
Important Safety Advice
WARNING –THIS APPLIANCE MUST NOT BE USED IN A BATHROOM.
WARNING - DO NOT USE THIS HEATER IN THE IMMEDIATE
SURROUNDINGS OF A BATH, A SHOWER OR A SWIMMING POOL.
WARNING – THIS HEATER MUST NOT BE LOCATED IMMEDIATELY BELOW A FIXED SOCKET OUTLET.
The plug must be accessible after heater installation.
DO NOT USE THE HEATER UNTIL THE FEET OR WALL BRACKETS ARE FITTED CORRECTLY.
FOLLOW these instructions carefully.
The heater carries a warning ‘DO NOT COVER’ to alert the user to the risk of fire that exists if the heater is accidentally covered.
Models DXLWP400TI, DXLWP800TIN and ARLWP800TI can be set to switch on automatically. Remember to observe all safety warnings at all times.
This appliance is not intended for use by children or other persons without assistance or supervision if their physical, sensory or mental capabilities prevent them from using it safely. Children should be supervised to ensure that they do not play with the appliance.
INDUKLWPRG Issue 6
600 mm - 400W
800 mm - 800W
500 mm
Electrical Connection
WARNING THIS APPLIANCE MUST BE EARTHED
If the socket outlets in your home are not of the 13 amp BS1363 type they will not accept the plug connected to this heater, therefore cut off the plug. When cut off this plug can constitute a shock hazard if inserted into a socket outlet. It must therefore be disposed of safely.
Before wiring the appropriate plug please note that the wires in this mains lead are coloured in accordance with the following code.
GREEN/YELLOW: EARTH BLUE: NEUTRAL BROWN: LIVE
Connect the Green/Yellow wire to the terminal marked E or the
earth symbol Connect the Brown wire to the terminal marked L or coloured
Red. Connect the Blue wire to the terminal marked N or coloured
Black. DO NOT connect the Brown (Live) or the Blue (Neutral) wires to
the Earth terminal of your 13 amp plug. If the terminals of the plug are unmarked or you are in any doubt, consult a qualified electrician.
CAUTION: If you use this heater in conjunction with a thermal control, programme controller, timer or any other device which switches the heater on automatically observe all safety warnings at all times.
or coloured Green or Green/Yellow.
If young children, the aged or infirm are likely to be left in the vicinity of the heater, we advise that adequate precautions should be taken. We recommend a guard be fitted to ensure contact with the heater is avoided and objects cannot be inserted into the product.
If the mains lead is damaged, it must be replaced by the manufacturer or its service agent or a similarly qualified person in order to avoid a hazard.
For further information, please contact our guard supplier direct on Tel. No. 01603 667957, or in case of difficulty or for further advice contact the Customer Helpline.
Positioning the Heater
Select the position for the heater ensuring there is clearance from any furniture and fittings of at least 150mm above the heater, 50mm below (wall mounted) and 25mm each side. Curtains must not be closer than 150mm from the top of the heater.
130mm
340mm - 400W 540mm - 800W
130mm
150mm
95mm
Free Standing Operation (see Fig. 1)
NEVER USE THE HEATER FREE STANDING WITHOUT THE FEET FITTED (FEET ARE PACKED SEPARATELY IN CARTON).
1. Lay the heater on its front.
2. Remove the two socket head screws from the base of the heater using the hexagon key supplied.
3. Place feet over base of heater, align holes and engage hook on foot into the recess on the back of the heater ­see Fig. 1.
4. Replace the screws but do not overtighten.
Fig. 1
Rear View
Installation
The Fixing Kit should contain: 1 Drilling Template, 3 Screws, 3 Rawlplugs, 1 Mounting Bracket and 1 Hexagon Key.
Wall Mounted Operation (see Fig. 2)
Suggested Fixings
SOLID BRICK/BLOCK: No. 8 Rawlplug inserts, 6mm drill bit. PLASTERBOARD: If possible locate studding and use No. 8
woodscrews directly into the wood, otherwise M5 rawlplug intersets are suitable.
NOTE: FOR OTHER WALL TYPES (e.g. Timber frame and hollow concrete) SEEK SPECIALIST ADVICE.
1. Select the position for the heater ensuring there is clearance from any furniture and fittings of at least 150mm above the heater, 50mm below and 25mm each side.
Curtains must not be closer than 150mm from the top of theheater.
2. Position the drilling template provided on the wall ensuring it is level. Mark the position of the relevant holes on the wall at the edge of template. Before drilling check that the distance between the hole centres is correct, 340mm for 400W Models and 540mm for 800W models (see Fig. 2).
25mm 25mm
Bracket
Drilling Holes
420mm
50mm
Fig. 2
3. Drill the wall at the three marked positions and fit the wall plugs.
Ensure template has been removed.
4. Fix two No. 8 screws to the top two holes leaving 3mm of the screw exposed. Hang the heater on the screws.
5. Fit the bottom bracket, found in the fixing kit, in the slot at the base of the heater and screw the bracket to the wall.
Test that the heater is now securely fixed to the wall.
Operation
IMPORTANT - OBJECTS OR CLOTHING MUST NOT BE PLACED ON THIS HEATER.
Before using the heater ensure that all warnings and instructions have been read carefully.
OPERATION - SINGLE RATED MODELS
Models DXLWP400, DXLWP400TI, DXLWP800, and DXLWP800TI N
Turn the heater on using the switch on the right side of the heater
- the switch will be illuminated.
OPERATION - DUAL RATED MODEL - Model ARLWP800TI
The two switches on the side of the heater control the heat output. Both switches illuminated indicates maximum output.
Top switch only illuminated indicates 500W output on 800W model.
Bottom switch only illuminated indicates 300W output on 800W model.
Note: on models fitted with a timer, at least one switch must be illuminated for the heater to operate.
MODELS WITH TIMER - (see Fig. 3)
DXLWP400TI and DXLWP800TI N - 1 Switch,
The switch on the side of the heater turns the heater on. Note: This switch must be in the “on” position before the heater
will operate.
ARLWP800TI - 2 Switches
The two switches on the side of the heater control the amount of heat available as described above, (Operation - Dual Rated Model).
NOTE: At least one switch must be in the ‘On’ position before the heater will operate.