Dillon 30784-0033, 30006-0019, 30006-0100, 30006-0092, 30007-0034 User Manual

...
Mechanical AP
Dynamometers
Installation
Instructions
AWT35-501027
Issue AD
Dillon is a trademark of the Illinois Tool Works group of companies whose ultimate parent company is Illinois Tool Works Inc (“Illinois Tool Works”). Copyright © 2014 Illinois Tool Works. All rights reserved.
No part of this publication may be reproduced by making a facsimile copy, by the making of a copy in three dimensions of a two-dimensional work and the making of a copy in two dimensions of a three-dimensional work, stored in any medium by electronic means, or transmitted in any form or by any means, including electronic, mechanical, broadcasting, recording or otherwise without the prior written consent of the copyright owner, under license, or as permitted by law.
This publication was correct at the time of going to print, however Avery Weigh-Tronix reserves the right to alter without notice the specification, design, price or conditions of supply of any product or service at any time.
AP_Dynamometer_small_i_en_501027.book Issue AD
1 General information and
warnings

1.1 About this manual

This manual is divided into chapters by the chapter number and the large text at the top of a page. Subsections are labeled as shown by the 1.1 and 1.1.1 headings. The names of the chapter and the next subsection level appear at the top of alternating pages of the manual to remind you of where you are in the manual. The manual name and page numbers appear at the bottom of the pages.

1.2 Special messages

Examples of special messages you will see in this manual are defined below. The signal words have specific meanings to alert you to additional information or the relative level of hazard.
WARNING! This is a Warning symbol. Warnings mean that failure to follow specific practices and procedures may have major consequences such as injury or death.
CAUTION! This is a Caution symbol. Cautions give information about procedures that, if not observed, could result in damage to equipment or corruption to and loss of data.
NOTE: This is a Note symbol. Notes give additional and important information, hints and tips that help you to use your product.

1.3 Safe Operation

WARNING: If you overload this dynamometer you could suffer severe injuries or death. The total load on the dynamometer should NEVER exceed the rated capacity.
Keep all the following in mind as you use the dynamometer.
The system capacity is equal to the rating of the dynamometers. The shackle rating should not be used to determine lift capacity of the system.
The shackles are rated in metric tonnes. Thus the 12-tonne shackles are rated to 26,450 lbf and are suitable for use on the 25,000 lbf dynamometer.
Any zeroed deadload must be considered as part of the ultimate load.
Although this instrument has a substantial overload protection rating, the instrument should not be used above the rated capacity. Doing so can significantly impact fatigue life of the instrument and cause premature and abrupt failure. If a higher capacity reading is needed, Dillon insists that a larger instrument be used.
Safety is always a concern in overhead lifting and tensioning applications. To limit your liability always insist upon factory supplied shackles and pins and factory tested and certified safe optional equipment. All DILLON products are designed to meet the published Safe Working Load (SWL) and Ultimate Safety Factor (USF) standards of the United States Military. All CE marked models meet the SWL and ULL (Ultimate Load Limit) requirements of the European Machinery Directive.
Do not grind, stamp, drill or deform the metal on the dynamometer body in any way. Protect the instrument from impact in use and storage.
Any significant damage or deformation to the loading element is cause for evaluation by Dillon.
Relieve all torsional and off axis loads.
Apply load in the center of the shackle bow with this instrument.
Off center loading results in substandard performance.
Instrument requires time to stabilize when changing temperatures.
Use only the hardware supplied with this instrument. If no hardware was supplied, insure that the mating pin and shackle bow is equivalent to the hardware used at calibration. Otherwise substandard performance or failure can result.
Dillon recommends only using qualified rigging hardware and cannot be responsible for unapproved hardware.
This instrument is not designed for the following:
l Applications that see rapid, dramatic
temperature swings or thermal shock. Wide variation in readings can occur.
l Intrinsically safe environments. This unit
has not been Factory Mutual or ATEX tested.

1.4 Routine maintenance

IMPORTANT: This equipment must be routinely checked for proper operation and calibration.
Application and usage will determine the frequency of calibration required for safe operation.

1.5 Cleaning the Dynamometer

Cleaning DOs and DON’Ts
l DO - Wipe down the outside of standard
products with a clean cloth, moistened with water and a small amount of mild detergent
l DO NOT - Attempt to clean the inside of the
machine
l DO NOT - Use harsh abrasives, solvents,
scouring cleaners or alkaline cleaning solutions

1.6 Training

Do not attempt to operate or complete any procedure on a machine unless you have received the appropriate training or read the instructions.

1.7 Declaration of Conformity

EN
EU
Declaration of
Conformity
Name and address of the manufacturer:
Avery Weigh-Tronix
1
Foundry Lane
Smethwick
West Midlands
B66 2LP
ENGLAND
This declaration of conformity is issued under the sole re-
sponsibility of the manufacturer
Object of the declaration:
Dillon
2
AP 5” 500lb - 20,000lb
Dillon
2
AP 5” 500kg - 10,000kg
Dillon
2
AP 10” 1000lb - 30,000lb
Dillon
2
AP 10” 500kg - 20,000kg
Klaxon Alarm
The object of the declaration described above is in conformity
with the relevant Union harmonisation legislation:
Applicable Directives Harmonised
standards
or other technical
specifications
Additional information:
Note
1
:
ITW Ltd trading as Avery Weigh-Tronix
Reg. Office: Admiral House, St Leonards Road,
Berkshire, SL4 3BL, England
Note
2
:
Dillon is part of Avery Weigh-Tronix
Note
3
:
A copy of the Technical File for this equipment is
available from M.S. Williams at the address above. Signed for and on behalf of:
Avery Weigh-Tronix
at
1000 Armstrong Drive, Fairmont, MN, 56031-1439,
USA
on
2016-04-20
K.Detert
Global Head of R&D
Model / Type:
Dillon AP
2014/30/EU
Electromagnetic Compatibility
EN61000-6-3:2007
+A1:2011
The machinery fulfills all the relevant provisions of the
Machinery Directive 2006/42/EC
3
Serial Number: X12500 Onwards
76501-504 Issue
1
DE
EU-
Konformitätserklärung
Name und Anschrift des Herstellers:
Avery Weigh-Tronix
1
Foundry Lane
Smethwick
West Midlands
B66 2LP
ENGLAND
Die alleinige Verantwortung für die Ausstellung dieser Kon-
formitätserklärung trägt der Hersteller.
Gegenstand der Erklärung:
Dillon
2
AP 5” 500lb - 20,000lb
Dillon
2
AP 5” 500kg - 10,000kg
Dillon
2
AP 10” 1000lb - 30,000lb
Dillon
2
AP 10” 500kg - 20,000kg
Klaxon-Alarm
Der oben beschriebene Gegenstand der Erklärung erfüllt die
einschlägigen Harmonisierungsrechtsvorschriften der Union:
Angewandte Richtlinien Harmonisierte
Normen oder
sonstigen
technischen
Spezifikationen
Zusatzangaben:
Anmerkung
1
:
ITW Ltd Handel als Avery Weigh-Tronix
Sitz: Admiral House, St Leonards Road,
Berkshire, SL4 3BL, England
Anmerkung
2
:
Dillon ist ein Teil von Avery Weigh-Tronix
Anmerkung
3
:
Eine Kopie der technischen Unterlagen für dieses Gerät
kann von M.S.Williams bei der über stehenden Adresse
angefordert warden.
Unterzeichnet für und im Namen von:
Avery Weigh-Tronix
bei
1000 Armstrong Drive, Fairmont, MN, 56031-1439,
USA
am
2016-04-20 K.Detert
Globaler Leiter von
Forschung und Entwicklung
Modell / Typen:
Dillon AP
2014/30/EU
Elektromagnetische Verträglichkeit
EN61000-6-3:2007
+A1:2011
Seriennummer: Ab X12500
Diese Maschine erfüllt die entsprechenden Bestimmungen
der Maschinenrichtlinie 2006/42/EG
3
FR
DéclaraƟonUE
de
Conformité
Nom et adresse du fabricant :
Avery Weigh-Tronix
1
Foundry Lane
Smethwick
West Midlands
B66 2LP
ANGLETERRE
La présente déclaration de conformité est établie sous la
seule responsabilité du fabricant.
Objet de la declaration:
Dillon
2
AP 5” 500lb - 20,000lb
Dillon
2
AP 5” 500kg - 10,000kg
Dillon
2
AP 10” 1000lb - 30,000lb
Dillon
2
AP 10” 500kg - 20,000kg
Klaxon d’alarme
L’objet de la déclaration décrit ci-dessus est conforme à la
législation d’harmonisation de l’Union applicable:
Les directives en vigueur Les normes
harmonisées ou
d’autres
spécifications
techniques
Informations complémentaires:
Nota
1
:
ITW Ltd exerçant également sous le nom de Avery Weigh-
Tronix
Siège social: Admiral House, St Leonards Road,
Berkshire, SL4 3BL, Angleterre
Nota
2
:
Dillon fait partie d'Avery Weigh-Tronix
Nota
3
:
Pour obtenir un exemplaire de la Fiche technique de cet
équipement, s’adresser à M.S.Williams à l’adresse
ci-dessus.
Signé par et au nom de:
Avery Weigh-Tronix à 1000 Armstrong Drive, Fairmont, MN, 56031-1439,
USA
le
2016-04-20 K.Detert
Responsable Mondial de la
Recherche et du Développement
Modèle / Type:
Dillon AP
2014/30/UE
Compatibilité Électromagnétique
EN61000-6-3:2007
+A1:2011
Numéro de série: A partir de X12500
La machine remplit l’ensemble des specifications du cahier
des charges de la Directive relative aux machines
2006/42/CE
3
NL
EU-
Conformiteitsverklar-
ing
Naam en adres van de fabrikant :
Avery Weigh-Tronix
1
Foundry Lane
Smethwick
West Midlands
B66 2LP
ENGELAND
Deze conformiteitsverklaring wordt verstrekt onder volledige
verantwoordelijkheid van de fabrikant.
Voorwerp van de verklaring:
Dillon
2
AP 5” 500lb - 20,000lb
Dillon
2
AP 5” 500kg - 10,000kg
Dillon
2
AP 10” 1000lb - 30,000lb
Dillon
2
AP 10” 500kg - 20,000kg
Klaxon Alarm
De machine voldoet aan alle relevante bepalingen van de
Richtlijn inzake machines 2006/42/EG
3
Toepasselijke richtlijnen Geharmoniseerde
standaarden
of andere
technische
specificaties
Aanvullende informatie:
Noot
1
:
ITW Ltd trading als Avery Weigh-Tronix
Zetel: Admiral House, St Leonards Road,
Berkshire, SL4 3BL, England
Noot
2
:
Dillon is een onderdeel van Avery Weigh-Tronix
Noot
3
:
Een kopie van het technisch bestand voor deze
apparatuur is verkrijgbaar van M.S. Williams op het
bovenstaande adres.
Ondertekend voor en namens:
Avery Weigh-Tronix
bij
1000 Armstrong Drive, Fairmont, MN, 56031-1439,
VS
op
2016-04-20 K.Detert
Wereldwijd Hoofd van Onderzoek en
Ontwikkeling
Model / Type:
Dillon AP
2014/30/EU
Elektromagnetische compatibiliteit
EN61000-6-3:2007
+A1:2011
Serienummer: Vanaf X12500
Het hierboven beschreven voorwerp is in overeenstemming
met de desbetreffende harmonisatiewetgeving van de Unie:
IT
Dichiarazione
di
Conformità UE
Nome e indirizzo del fabbricante:
Avery Weigh-Tronix
1
Foundry Lane
Smethwick
West Midlands
B66 2LP
INGHILTERRA
La presente dichiarazione di conformità è rilasciata sotto la
responsabilità esclusiva del fabbricante.
Oggetto della dichiarazione:
Dillon
2
AP 5” 500lb - 20,000lb
Dillon
2
AP 5” 500kg - 10,000kg
Dillon
2
AP 10” 1000lb - 30,000lb
Dillon
2
AP 10” 500kg - 20,000kg
Klaxon allarme
L’oggetto della dichiarazione di cui sopra è conforme alla
pertinente normativa di armonizzazione dell’Unione:
Direttive applicabili Armonizzato
standard
o altre specificazioni
tecniche
Informazioni supplementari:
Nota
1
:
ITW Ltd trading come Avery Weigh-Tronix
Sede dell'ufficio: Admiral House, St Leonards Road,
Berkshire, SL4 3BL, England
Nota
2
:
Dillon è parte di Avery Weigh-Tronix
Nota
3
:
Una copia della scheda techica di questo apparecchio è
disponibile presso M.S.Williams, all’indirizzo sopra.
Firmato a nome e per conto di:
Avery Weigh-Tronix a 1000 Armstrong Drive, Fairmont, MN, 56031-1439,
U.S.A.
su
2016-04-20 K.Detert
Responsabile Globale della Ricerca e
Sviluppo
Modello / Tipo:
Dillon AP
2014/30/UE
Compatibilità elettromagnetica
EN61000-6-3:2007
+A1:2011
N. di serie: A partire da X12500
L’apparecchio rispetta tutte le disposizioni rilevanti della
Divertiva Macchine 2006/42/CE
3
ES
DeclaraciónUE
de
Conformidad
Nombre y dirección del fabricante
Avery Weigh-Tronix
1
Foundry Lane
Smethwick
West Midlands
B66 2LP
INGLATERRA
La presente declaración de conformidad se expide bajo la
exclusiva responsabilidad del fabricante.
Objeto de la declaración:
Dillon
2
AP 5” 500lb - 20,000lb
Dillon
2
AP 5” 500kg - 10,000kg
Dillon
2
AP 10” 1000lb - 30,000lb
Dillon
2
AP 10” 500kg - 20,000kg
Alarma Klaxon
El objeto de la declaración descrita anteriormente es
conforme con la legislación de armonización pertinente de la
Unión:
Directivas aplicables Normas
armonizadas u
otras
especificaciones
técnicas
Información adicional:
Nota
1
:
ITW Ltd trading as Avery Weigh-Tronix
Oficina registrada: Admiral House, St Leonards Road,
Berkshire, SL4 3BL, Angleterre
Nota
2
:
Dillon es parte de Avery Weigh-Tronix
Nota
3
:
Puede solicitarse a M.S.Williams una copia del
expediente técnico correspondiente a este equipo en la
dirección que se indica.
Firmado en nombre de:
Avery Weigh-Tronix
en
1000 Armstrong Drive, Fairmont, MN, 56031-1439,
EE.UU
el
2016-04-20 K.Detert
Jefe Global de Investigación y
Desarrollo
Modelo / Tipo:
Dillon AP
2014/30/UE
Compatibilidad electromagnética
EN61000-6-3:2007
+A1:2011
Número de serie: A partir del X12500
La máquina cumple con todas las disposiciones pertinentes
de la Directiva 2006/42/CE relative a las máquinas
3
2 Introduction
Shackle
Shackle
Shackle pin
Shackle pin
Bezel
Maximum pointer
Pointer

2.1 General description

A dynamometer is an instrument that displays the tension force exerted between the two attached shackles. It is generally used to determine tension in a line/cable or for suspended weighing.
The 50,000 lb dynamometer is not CE approved.
Figure 2.1 shows one model of dynamometer.

Figure 2.1 Dynamometer with shackles

CAUTION: Dillon Dynamometers are not
To replace batteries: Remove four screws and back panel from the klaxon alarm, remove old D-cell batteries, replace with two new batteries. Replace back panel.
Test Button: Press to test horn function
Klaxon alarm is rated at 80db(A) @
0.6 meters (2 feet).
Needle bearing inside deflection beam.
Zero adjustment knob
designed for measurement of dynamic shock loads and should not be subjected to sudden force. Load or weight should be applied in a gradual manner to avoid damaging the Dynamometer. Torque loads applied to the dynamometer should be relieved or avoided.
Figure 2.2 shows an optional klaxon alarm attached to an
AP dynamometer.
Figure 2.2 AP Dynamometer with optional klaxon
alarm (rear view)
The klaxon alarm is rated at 80db(A) @
0.6 meters (2 feet).
Heavy duty needle bearings inserted in each end of the Dynamometer deflection beam (or into both sides of the shackles ears) allow the shackle pin to rotate as force is applied. See Figure 2.2. Bearings should be cleaned periodically in a suitable solvent. After drying, the bearings should be treated with a coat of light machine oil (SAE-5W non-detergent oil or lighter).
CAUTION: DO NOT allow oil to run into the mechanism case. The mechanism should never be oiled as this tends to attract dust or dirt.
The case is not water-tight and if the Dynamometer should be accidentally immersed, hold it so that water is free to run out through the openings in the bottom of the case and allow to dry.

2.2 Third-party shackles and attachments

Dillon supplies shackles and pins with the dynamometers that have been confirmed to properly work with our mechanical dynamometers. Do not use shackles or shackle pins that have not been qualified by Dillon. Lower profile non-machined spots can often be observed and are normal.
If any type of accessory fitting is made for use with the Dillon Dynamometer, be sure to machine this from high grade aircraft alloy (E4340 steel or equivalent) and heat treat it in order to ensure maximum safety.
Dillon / Avery Weigh-Tronix is not responsible for failure of attachment fittings furnished by others.

2.3 Maintenance and handling

The Dillon Dynamometer is a precision instrument and will provide many years of dependable service if given reasonable care and suitable protection. Many firms make it a regular practice to return Dynamometers to their distributors at 6 to 8 month intervals (depending upon how much they are used) to have accuracy recertified. We recommend this at least once a year. Consult with your Dillon distributor concerning any questions you may have about recalibration intervals. Your area may require periodic proof testing. Consult your local regulations.
Transport and store the dynamometer in the supplied storage case when not in use.

2.4 Operation

Zero the dynamometer for best accuracy. To properly zero the instrument when using the max pointer, adjust the black needle below the desired zero point using the zero adjustment wheel on the rear of the case. Move the red maximum pointer counterclockwise until it contacts the black needle. Use the zero adjustment wheel to simultaneously move both pointers to the desired zero point. This procedure will prevent the slight drag of the max pointer from influencing the displayed reading. If the max pointer is not required, rotate the red pointer clockwise until it reaches the zero position and operate normally.
WARNING: Failure to adjust the max hand prior to use of the Dynamometer WILL affect the readings if the max hand is used.
Dillon Mechanical Dynamometers permit zeroing of up to 20% of instrument capacity. Do not zero off a deadload and then use the instrument to capacity.
AUTHORIZED DISTRIBUTORS
Ask the experts. Dillon distributors offer complete
service capabilities from application assistance to sales and product support. Their experienced representatives are the most knowledgeable experts that you will find in the force measurement industry. We recommend that you consult these capable specialists for all of your measuring needs.
Overload Protection and Overhead Weighing Equipment
1000 Armstrong Drive Fairmont, Minnesota U.S.A. 56031 Toll-Free: (800) 368-2031 Phone: (507) 238-4461 Fax: (507) 238-8258
Foundry Lane, Smethwick West Midlands B66 2LP Tel: +44 (0) 845 246 6717 Fax: +44 (0) 845 246 6718 www.dillon-force.com Dillon is a brand of Avery Weigh-Tronix
Loading...