Digi ConnectPort LTS 8, ConnectPort LTS 32, ConnectPort LTS 16 Quick Start Manual

ExpressCard SD
Power Ready Diagnostic
Console Modem
DTR
DCD
Factory Reset
USB1
USB2
C O NN E C T P O R T
LTS
Quick Start Guide
1
ConnectPort LTS
RJ-45 diagnostic loopback
Power cord (US models only)
What’s in the box
© 2015 Digi International Inc. Digi, Digi International Inc., ConnectPort, RealPort, and the Digi logo are trademarks or registered trademarks of Digi International Inc. in the United States and other countries worldwide. All other trademarks are the property of their respective owners.
ConnectPort® LTS 8/16/32
2
Connect the hardware
Connect the Ethernet cable to the Ethernet 1 port.
Connect the serial devices to the serial ports, following the pin-position information below. If serial devices are EIA-422/485, see steps 4e and 4f.
b
Cord and brick power supply (for LTS 8 models).
Power cord (for U.S. models).
Connect the power supply to the POWER connector.
ConnectPort LTS
Cord and brick power supply (ConnectPort LTS 8 models only)
Pin # on 10-wire connector
EIA-422/485 Full-Duplex
EIA-232
1 RI TxD­2 DSR* RxD-
3 RTS RTS+
4 CGND CGND
5 TxD TxD+
6 RxD+
7 SGND SGND 8 CTS CTS+ 9 DTR RTS-
10 CTS-
RxD
DCD*
EIA-485 Half-Duplex
N/A DATA-
N/A
CGND
N/A
DATA+
SGND N/A N/A
N/A
Serial port pin assignments:
MEI versions only:
ConnectPort LTS products use an RJ-45 10-wire jack (female), with Pin 1 in the following location:
a
Pin # on 8-wire connector
2
3
4
5
6 7 8
1
10-wire connector (male):
Pin positions for connecting serial devices:
For an 8-wire connector, connect the pins to the center 8 pins of the 10-wire jack:
For a 10-wire connector, Pin 1 of the connector is in the following location:
10-wire jack (female):
8-wire connector (male):
Ports, connectors, LEDs, and buttons:
Insertion end
Insertion end
Pin 1
c
*Use the Altpin setting to swap these two signals.
DP-9F console adapter
XBee antenna (W models only)
Rack mount brackets (16/32 port models only)
Ethernet cable
W models only: Connect the XBee antenna to the XBEE connector.
d
Serial port side
Reverse side
a
b
c
d
Top view
Top view
ConnectPort LTS 16/32 - Serial port side
ConnectPort LTS 16/32 - Reverse side
ConnectPort LTS 16 Dual Power - Serial port side
ConnectPort LTS 16 Dual Power - Reverse side
C
O NN E C TPO RT
LT S 3 2
Up
Dn
Sel
Ext
1 2 3 4 5 6 7 8
17 18 19 20 21 22 23 24
9 10 11 12 13 14 15 16
25 26 27 28 29 30 31 32
Ethernet 1
Ethernet 2
Power
SD
USB1
USB2
C
ON N E C TPOR T
LT S 8
Power Ready Diagnostic
Up
Dn
Sel
Ext
C
O NN E C TPO RT
LT S 1 6
1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16
Ethernet 1
Ethernet 2
Power 2
Power 1
SD
Power 1 Power 2 Ready Diagnostic
Console Factory Reset
C O NN E C T P O R T
LTS
Up
Dn
Sel
Ext
Power
– +
C
ON N E C TPOR T
LTS-W
Console
Modem
DTR
DCD
Factory
Reset
Ethernet 1
Ethernet 2
1 2 3 4
5 6 7 8
ConnectPort LTS 8 - Serial port side
Power connector
Ethernet ports
Serial ports
Analog modem port (W models only)
DTR/ DCD LEDs
Factory reset button
Console port
Power connector
Ethernet ports
Serial ports
LCD display
LCD control buttons
Express card slot (W models only)
SD card slot
Power LED
Ready LED
Diagnostic LED
XBee antenna connector (W models only)
USB ports
Factory reset button
Console port
DTR/ DCD LEDs
Analog modem port (W models only)
Serial ports
Ethernet ports
Power 2 connector
Power 1 connector
Console port
Factory reset button
Power 1 LED
Power 2 LED
Ready LED
SD card slot
Diagnostic LED
LCD display
LCD control buttons
ConnectPort LTS 8 - Reverse side
SD
USB1
USB2
C
ON N E C TPOR T
LT S 8
Power Ready Diagnostic
Up
Dn
Sel
Ext
Diagnostic LED
SD card slot
USB ports
XBee antenna connector (W models only)
Power LED
Ready LED
LCD display
LCD control buttons
4
5 Locate the appropriate cable adapters for your product
Congure the serial ports
Part Number
Cable Adapter
Application
76000697
76000698
76000699
76000700
76000701
76000692
76000631
63000042-01
Digi TS DB-9F Console Adapter (4-pk)
Digi TS DB-25M Console Adapter (4-pk)
Digi TS DB-25F Console Adapter (4-pk)
Digi TS DB-25M Modem Adapter (4-pk)
Digi TS DB-9M Modem Adapter (4-pk)
Digi TS DB-25M Printer Adapter (4-pk)
Digi TS to Sun Netra/Cisco Cable (single pk)
RJ-45 to RJ-45 Straight Through Ethernet Cable
Bay Accelar, Nortel and other DB-9 DTE devices.
Sun Sparc, Sun Ultra, terminal, printers and other DTE devices with DB-25 female ports.
Cisco, IBM and other DTE devices with DB-25 male ports.
Modems and other DCE devices with DB-25 female ports.
Modems and other DCE devices with DB-9 female ports.
For use with Cisco and Sun RJ-45 Console ports. Also available in 8-pk and 16-pk quantities.
Can be used as a networking cable or combined with one of the adapters as a serial cable.
The table below lists EIA-232 cable adapters that can be used with ConnectPort LTS products. For additional cabling information, go to www.digi.com/support/connectportlts and click the Documentation tab. To order cables, go to the Digi Support site at www.digi.com/support and click Cabling.
For use with printers. This adapter diers from a Console Adapter in that it uses the DTR signal instead of RTS for hardware ow control.
Navigate to www.digi.com/support/connectportlts. Click the Documentation link. Click Users Guide: ConnectPort LTS / LTS MEI / LTS W / LTS MEI W to open the User Guide for this product.
c
a
b
d
e
f
Use the Device Discovery Utility or Digi Port Authority -- Remote to discover devices on your network and open the web interface:
- In the list of discovered devices, select the ConnectPort LTS device.
- Using the Digi Discovery Utility or Digi Port Authority, congure the IP address if necessary. See Alternative IP address setup using the LCD display below.
- Open the ConnectPort LTS web interface. In the Device Discovery Utility, click Open web interface. In Digi Port Authority-Remote, click Device Conguration.
- A login prompt for the web interface is displayed. Enter the default username and password: root and dbps.
Alternative IP address setup using the LCD display
You can also set a static IP address using the LCD display and LCD control buttons.
- Press the Sel button to navigate to these settings: CONFIGURATION > IP SETTINGS #1> IP MODE:STATIC > IP ADDRESS > EDIT.
- Use the Up and Dn buttons to select the correct IP address from the displayed addresses; press Ext when done.
- If necessary, change SUBNET MASK and GATEWAY.
- Press the Ext button to exit the conguration menus.
- To save the IP settings, use the Dn and Sel buttons to select the SAVE command.
- Press the Ext button to exit the LCD display.
In the web interface, under Conguration, click Serial Ports.
Congure serial port settings using port proles. Port proles are a dened set of serial port parameters for a particular use. The web interface and User Guide contain descriptions of the port proles. For ConnectPort LTS products, Digi recommends the RealPort port prole. For help in conguring the device for use with other port proles, see the User Guide. To congure ports to use the RealPort port prole:
- On the Serial Port Conguration page, click the port to be congured.
- Click Change Prole.
- In the list of proles, select the RealPort port prole.
- Click Apply.
For EIA-232 devices that will be connected using 8-wire cables, congure the Altpin setting. The default for this setting is o; it must be enabled as needed for each serial port. For each applicable serial port:
- Click Advanced Serial Settings.
- Select the Enable DCD on 8-pin RJ45 connectors (Altpin) setting.
- Click Apply.
g
Your ConnectPort LTS device is now congured for basic serial port connectivity. For information on other conguration options and additional product information,
see the User Guide.
Note: Cable adapters are 8-wire. If you are using these cable adapters with modems, or other applications that require Data Carrier Detect (DCD) control, you must enable the alternate pinout setting, or Altpin, as shown in step 4e.
The serial ports for ConnectPort LTS MEI products are set to EIA-232 by default. For serial ports that connect to EIA-422 or EIA-485 devices, congure the serial ports. For each applicable serial port:
- Click the serial port to select it.
- On the Serial Port Conguration page, click the link Basic Serial Settings.
- For MEI Type, select RS422/485 for EIA-422/485 4-wire Full-Duplex or RS485-HALF for EIA-485 2-wire Half-Duplex.
- Select Enable termination if termination or use of biasing resistors is needed across the lines. Enable this setting if the terminal server port is an endpoint node of the EIA-422/485 network and termination or biasing is desired. If using 2-wire mode, termination or biasing is used at one of the end points; usually the Master endpoint. Note: The CTS and RTS control signals are available as separate dierential signals in the EIA-422/EIA-485 4-wire mode. Do not use these dierential signals in 2-wire mode. The CTS and RTS dierential signals are not terminated or biased internally. If termination or biasing is needed, it must be done externally.
- Click Apply.
3
Download required software
Digi provides several utilities that discover devices present on a network. You will need to download either the Device Discovery Utility or
Digi Port Authority - Remote.
- Navigate to: www.digi.com/support/connectportlts.
- Click the link Diagnostics, Utilities, and MIBs.
- Select your operating system. A list of available downloadable utilities for your operating system is displayed.
- Download and run either the Device Discovery Utility or Digi Port Authority - Remote.
a
b
If the serial ports for your product will be managed using Digi’s RealPort software, download the RealPort software.
- Navigate to: www.digi.com/support/connectportlts.
- Click the link Drivers.
- Select your operating system. A list of available downloads and release notes for your operating system is displayed.
- Download the Realport driver and the release notes. For Microsoft Windows operating systems, unzip the download package and run the executable. For Linux or Unix operating systems, unload the release notes rst and follow the instructions in the release notes.
Loading...