1. Protecting the Board from Damage
Caution! All computer boards are sensitive to
electrostatic discharge (“ESD”). Handle all staticsensitive boards and components at a static-safe work
area, and observe anti-static precautions at all times.
If you are not familiar with ESD safety precautions, visit
http://www.dialogic.com/support/hwinstall to learn more.
Unpacking the Board
Unpack the Dialogic
according to the following steps:
1. Prepare a static-safeguarded work area.
2. Carefully remove the SIB from the shipping carton
and anti-static packaging. Handle the SIB by the
edges and avoid touching the components.
3. Lay the SIB on the static-dissipative work surface.
Note: Place the SIB in static-shielding bags when carrying
from station to station.
CAUTION: Do not remove the SIB from the anti-static
packaging until you are ready to install it. Observe proper
anti-static precautions at all times.
®
Station Interface Box (“SIB”)
All Rights Reserved.
Physical Description
SI\240 Board
STA
Connector
Bail
Lock
2. Upgrading the Station Interface Box
The Dialogic® Station Interface Box (“SIB”) is a single
unit that supports 48 stations in the base model
configuration. However, the SIB is a modular unit that is
designed to accommodate 72, 96, and 120 stations.
Configuring the Station Density
To support 72 stations, install one SI/240 board at the
location designated
support 96 stations, install two SI/240 boards; one
daughter board at the location designated
the other daughter board at the location designated
STA 73-96 on the SIB rear panel. To support 120
stations, install three SI/240 boards; the first daughter
board at the location designated
daughter board at the location designated
the last daughter board at the location designated
STA 97-120 on the SIB rear panel.
Use the following table to determine the correct location
for installing the SI/240 boards in your SIB.
STA 49-72 on the SIB rear panel. To
STA 49-72 and
STA 49-72, the second
STA 73-96, and
SIB Station Density Table
Ribbon
Cable
Base Board
Connector
Station
Densit
y
48
72 X
96 X X
120 X X X
unless you install the SI/240 boards in the correct
locations on the SIB base board. The
connector designations are silk screened on the base
board to help you correctly install the SI/240 boards. (For
reference, base board connector
power supply fan.)
STA 49-72
Connector P3
Caution! The SIB will fail to function properly
STA 73-96
Connector P4
P3, P4, and P5
P3 is located nearest the
STA 97-120
Connector P5
3. Warnings
Warning! These procedures assume familiarity
with the general terminology associated with electronic
equipment and with the safety practices and regulatory
compliance required for using and modifying electronic
equipment.
Warning! These procedures should be performed
only by qualified technical personnel. Unplug the SIB
power cord before performing the procedures described
here. Failure to disconnect the power before you open the
chassis can result in personal injury or equipment
damage.
Warning! The power supply in the Dialogic
Station Interface Box contains no user-serviceable parts.
Refer servicing only to qualified technical personnel.
Warning! Ensure that the system is disconnected
from its power source and from all telecommunications
links, networks, or modem lines whenever the chassis
cover is removed. Do not operate the system with the
cover removed.
Advertissement! Assurez vous que le système
soit débranché de son alimentation ainsi que de toutes les
liaisons de télécommunication, des réseaux, et des lignes
de modem avant d’enlever le capot. Ne pas utiliser le
système quand le capot est enlevé.
Warnug! Das System darf weder an eine
Stromquelle angeschlossen sein noch eine Verbindung
mit einer Telekommunikationseinrichtung, einem
Netzwerk oder einer Modem-Leitung haben, wenn die
Gehäuseabdeckung entfernt wird. Nehmen Sie das
System nicht ohne die Abdeckung in Betrieb.
Avvertenza! Prima di rimuovere il coperchio del
telaio, assicurarsi che il sistema sia scollegato
dall’alimentazione, da tutti I collegamenti di
comunicazione, reti o linee di modem. Non avviare il
sistema senza aver prima messo a posto il coperchio.
Advertencias! Asegúrese de que cada vez que se
quite la cubierta del chasis, el sistema haya sido
desconectado de la red de alimentación y de todos lo
enlaces de telecomunicaciones, de red y de líneas de
módem. No ponga en funcionamiento el sistema mientras
la cubierta esté quitada.
®

Dialogic® Station Interface Box
Top Mounting
Screws (4 Req'd)
SI\240 Board
(Installed)
STA 49-72
STA 1-24
Power Supply
Connector
STA
Connector
Rear Mounting
Screws (2 Req'd)
STA 73-96
STA 25-48
Diag
Por t
4. Install the Board
1. Working at a static-safeguarded work area, disconnect
the SIB’s power cord from the electrical outlet and
remove the SIB cover.
Note: To remove the SIB cover, you must first
remove the top three screws on the front panel.
Remove
CoverPlate
STA 97-120
DIAG
J1
8-Pin
Modular Jacks
2. Remove the desired
SI\240
Daughter
Board
Mounting
J2 J3 J4
Connector
Board
Posts
Base
Board
STA XX-XXX connector access
cover plate and save the two rear mounting screws.
3. Attach the SI/240 board ribbon cable to the
appropriate base board connector (
Note: When you fully seat the SI/240 ribbon
cable connector, the base board ribbon cable extractor
clips lock into the vertical position.
P4
P3, P4, or P5).
Base Board
Connector
P5
Connector
4. Guide the SI/240 board’s STA connector into the hole
on the SIB rear panel, carefully lining up the top
mounting holes with the base board mounting posts.
5. Secure the board with four top mounting screws
(supplied) and the two saved rear mounting screws.
for your area. Address, telephone and fax numbers, are
available at the Dialogic website located at:
http://www.dialogic.com/contact.htm.
To purchase Dialogic
®
products, please refer to the
following website to locate the appropriate supplier.
Note: Make sure that the SI/240 board STA
connector contacts the SIB rear panel. Start the four
top mounting screws by hand first; then install and
fully tighten the two rear mounting screws. Finally,
fully tighten the top mounting screws.
6. After installing and connecting the SI/240 board(s),
replace the SIB cover and connect the power cord.
5. Warranty and Return Information
Warranty Period
For specific warranty information for this board, refer to the
Warranty section of the Products page, located at this URL:
http://www.dialogic.com/warranties/.
Contacting Technical Support
Dialogic provides technical support for its products through
a network of value added distributors who are trained to
answer technical questions on installing and configuring
Dialogic
®
products. If you are unsure how to contact your
support channel, please call Dialogic in the United States at
973-967-6600 (9am-5pm EST) and we will assist in
obtaining the appropriate support channel.
Outside the United States please refer to
http://www.dialogic.com/support/contact to obtain
local contact information.
Dialogic also provides direct support via Dialogic® Pro™
Services agreements. For more details of direct support
from Dialogic please refer to:
http://www.dialogic.com/support/DialogicPro.
Returning a Product
To return a board for warranty repair or any other returns,
please refer to the following:
http://www.dialogic.com/support/hwfaults.
To return a board for warranty repair, please refer to the
following: http://www.dialogic.com/support/hwfaults. For
all other returns, contact your vendor or Dialogic Customer
Support (for more information, see
http://www.dialogic.com/support/contact/ ).
http://www.dialogic.com/purchase.htm.
All contents of this document are furnished for informational use only and are
subject to change without notice and do not represent a commitment on the
part of Dialogic Corporation or its subsidiaries (“Dialogic”). Reasonable
effort is made to ensure the accuracy of the information contained in the
document. However, Dialogic does not warrant the accuracy of this
information and cannot accept responsibility for errors, inaccuracies or
omissions that may be contained in this document.
INFORMATION IN THIS DOCUMENT IS PROVIDED IN CONNECTION
WITH DIALOGIC
BY ESTOPPEL OR OTHERWISE, TO ANY INTELLECTUAL PROPERTY
RIGHTS IS GRANTED BY THIS DOCUMENT. EXCEPT AS PROVIDED
IN A SIGNED AGREEMENT BETWEEN YOU AND DIALOGIC,
DIALOGIC ASSUMES NO LIABILITY WHATSOEVER, AND DIALOGIC
DISCLAIMS ANY EXPRESS OR IMPLIED WARRANTY, RELATING TO
SALE AND/OR USE OF DIALOGIC PRODUCTS INCLUDING
LIABILITY OR WARRANTIES RELATING TO FITNESS FOR A
PARTICULAR PURPOSE, MERCHANTABILITY, OR INFRINGEMENT
OF ANY INTELLECTUAL PROPERTY RIGHT OF A THIRD PARTY.
Dialogic products are not intended for use in medical, life saving, life
sustaining, critical control or safety systems, or in nuclear facility
applications.
It is possible that the use or implementation of any one of the concepts,
applications, or ideas described in this document, in marketing collateral
produced by or on web pages maintained by Dialogic may infringe one or
more patents or other intellectual property rights owned by third parties.
Dialogic does not provide any intellectual property licenses with the sale of
Dialogic products other than a license to use such product in accordance with
intellectual property owned or validly licensed by Dialogic and no such
licenses are provided except pursuant to a signed agreement with Dialogic.
More detailed information about such intellectual property is available from
Dialogic’s legal department at 9800 Cavendish Blvd., 5
Quebec, Canada H4M 2V9. Dialogic encourages all users of its products to
procure all necessary intellectual property licenses required to
implement any concepts or applications and does not condone or
encourage any intellectual property infringement and disclaims any
responsibility related thereto. These intellectual property licenses may
differ from country to country and it is the responsibility of those who
develop the concepts or applications to be aware of and comply with
different national license requirements.
Dialogic, Diva, Eicon, Eicon Networks, Eiconcard, Dialogic Pro and
SIPcontrol, among others, are either registered trademarks or trademarks of
Dialogic. Dialogic's trademarks may be used publicly only with permission
from Dialogic. Such permission may only be granted by Dialogic’s legal
department at 9800 Cavendish Blvd., 5th Floor, Montreal, Quebec, Canada
H4M 2V9. Any authorized use of Dialogic's trademarks will be subject to full
respect of the trademark guidelines published by Dialogic from time to time
and any use of Dialogic’s trademarks requires proper acknowledgement. The
names of actual companies and products mentioned herein are the trademarks
of their respective owners.
®
PRODUCTS. NO LICENSE, EXPRESS OR IMPLIED,
th
Floor, Montreal,
6. Sales Assistance
If you have a sales question, please contact your
local Sales Representative or the Regional Sales Office