Dialogic SI-240 User Manual

Dialogic® Station Interface Box SI/240
Part Number 64-0022-02
Dialogic Corporation.

1. Protecting the Board from Damage

Caution! All computer boards are sensitive to
electrostatic discharge (“ESD”). Handle all static­sensitive boards and components at a static-safe work area, and observe anti-static precautions at all times.
If you are not familiar with ESD safety precautions, visit http://www.dialogic.com/support/hwinstall to learn more.
Unpacking the Board
Unpack the Dialogic according to the following steps:
1. Prepare a static-safeguarded work area.
2. Carefully remove the SIB from the shipping carton
and anti-static packaging. Handle the SIB by the edges and avoid touching the components.
3. Lay the SIB on the static-dissipative work surface.
Note: Place the SIB in static-shielding bags when carrying from station to station.
CAUTION: Do not remove the SIB from the anti-static packaging until you are ready to install it. Observe proper anti-static precautions at all times.
®
Station Interface Box (“SIB”)
All Rights Reserved.
Physical Description
SI\240 Board
STA
Connector
Bail
Lock

2. Upgrading the Station Interface Box

The Dialogic® Station Interface Box (“SIB”) is a single unit that supports 48 stations in the base model configuration. However, the SIB is a modular unit that is designed to accommodate 72, 96, and 120 stations.

Configuring the Station Density

To support 72 stations, install one SI/240 board at the location designated support 96 stations, install two SI/240 boards; one daughter board at the location designated the other daughter board at the location designated
STA 73-96 on the SIB rear panel. To support 120
stations, install three SI/240 boards; the first daughter board at the location designated daughter board at the location designated the last daughter board at the location designated
STA 97-120 on the SIB rear panel.
Use the following table to determine the correct location for installing the SI/240 boards in your SIB.
STA 49-72 on the SIB rear panel. To
STA 49-72 and
STA 49-72, the second
STA 73-96, and

SIB Station Density Table

Ribbon
Cable
Base Board
Connector
Station Densit y
48 72 X 96 X X
120 X X X
unless you install the SI/240 boards in the correct locations on the SIB base board. The connector designations are silk screened on the base board to help you correctly install the SI/240 boards. (For reference, base board connector power supply fan.)
STA 49-72
Connector P3
Caution! The SIB will fail to function properly
STA 73-96
Connector P4
P3, P4, and P5
P3 is located nearest the
STA 97-120
Connector P5

3. Warnings

Warning! These procedures assume familiarity
with the general terminology associated with electronic equipment and with the safety practices and regulatory compliance required for using and modifying electronic equipment.
Warning! These procedures should be performed
only by qualified technical personnel. Unplug the SIB power cord before performing the procedures described here. Failure to disconnect the power before you open the chassis can result in personal injury or equipment damage.
Warning! The power supply in the Dialogic
Station Interface Box contains no user-serviceable parts. Refer servicing only to qualified technical personnel.
Warning! Ensure that the system is disconnected
from its power source and from all telecommunications links, networks, or modem lines whenever the chassis cover is removed. Do not operate the system with the cover removed.
Advertissement! Assurez vous que le système
soit débranché de son alimentation ainsi que de toutes les liaisons de télécommunication, des réseaux, et des lignes de modem avant d’enlever le capot. Ne pas utiliser le système quand le capot est enlevé.
Warnug! Das System darf weder an eine
Stromquelle angeschlossen sein noch eine Verbindung mit einer Telekommunikationseinrichtung, einem Netzwerk oder einer Modem-Leitung haben, wenn die Gehäuseabdeckung entfernt wird. Nehmen Sie das System nicht ohne die Abdeckung in Betrieb.
Avvertenza! Prima di rimuovere il coperchio del
telaio, assicurarsi che il sistema sia scollegato dall’alimentazione, da tutti I collegamenti di comunicazione, reti o linee di modem. Non avviare il sistema senza aver prima messo a posto il coperchio.
Advertencias! Asegúrese de que cada vez que se
quite la cubierta del chasis, el sistema haya sido desconectado de la red de alimentación y de todos lo enlaces de telecomunicaciones, de red y de líneas de módem. No ponga en funcionamiento el sistema mientras la cubierta esté quitada.
®
Dialogic® Station Interface Box
Top Mounting
Screws (4 Req'd)
SI\240 Board
(Installed)
STA 49-72
STA 1-24
Power Supply
Connector
STA
Connector
Rear Mounting
Screws (2 Req'd)
STA 73-96
STA 25-48
Diag
Por t

4. Install the Board

1. Working at a static-safeguarded work area, disconnect the SIB’s power cord from the electrical outlet and remove the SIB cover.
Note: To remove the SIB cover, you must first
remove the top three screws on the front panel.
Remove
CoverPlate
STA 97-120
DIAG
J1
8-Pin
Modular Jacks
2. Remove the desired
SI\240
Daughter
Board
Mounting
J2 J3 J4
Connector
Board
Posts
Base
Board
STA XX-XXX connector access
cover plate and save the two rear mounting screws.
3. Attach the SI/240 board ribbon cable to the appropriate base board connector (
Note: When you fully seat the SI/240 ribbon
cable connector, the base board ribbon cable extractor clips lock into the vertical position.
P4
P3, P4, or P5).
Base Board
Connector
P5
Connector
4. Guide the SI/240 board’s STA connector into the hole on the SIB rear panel, carefully lining up the top mounting holes with the base board mounting posts.
5. Secure the board with four top mounting screws (supplied) and the two saved rear mounting screws.
for your area. Address, telephone and fax numbers, are available at the Dialogic website located at: http://www.dialogic.com/contact.htm.
To purchase Dialogic
®
products, please refer to the
following website to locate the appropriate supplier.
Note: Make sure that the SI/240 board STA
connector contacts the SIB rear panel. Start the four top mounting screws by hand first; then install and fully tighten the two rear mounting screws. Finally, fully tighten the top mounting screws.
6. After installing and connecting the SI/240 board(s), replace the SIB cover and connect the power cord.

5. Warranty and Return Information

Warranty Period
For specific warranty information for this board, refer to the Warranty section of the Products page, located at this URL: http://www.dialogic.com/warranties/.
Contacting Technical Support
Dialogic provides technical support for its products through a network of value added distributors who are trained to answer technical questions on installing and configuring Dialogic
®
products. If you are unsure how to contact your support channel, please call Dialogic in the United States at 973-967-6600 (9am-5pm EST) and we will assist in obtaining the appropriate support channel.
Outside the United States please refer to http://www.dialogic.com/support/contact to obtain local contact information.
Dialogic also provides direct support via Dialogic® Pro™ Services agreements. For more details of direct support from Dialogic please refer to: http://www.dialogic.com/support/DialogicPro.
Returning a Product
To return a board for warranty repair or any other returns, please refer to the following: http://www.dialogic.com/support/hwfaults.
To return a board for warranty repair, please refer to the following: http://www.dialogic.com/support/hwfaults. For all other returns, contact your vendor or Dialogic Customer Support (for more information, see http://www.dialogic.com/support/contact/ ).
http://www.dialogic.com/purchase.htm.
All contents of this document are furnished for informational use only and are subject to change without notice and do not represent a commitment on the part of Dialogic Corporation or its subsidiaries (“Dialogic”). Reasonable effort is made to ensure the accuracy of the information contained in the document. However, Dialogic does not warrant the accuracy of this information and cannot accept responsibility for errors, inaccuracies or omissions that may be contained in this document.
INFORMATION IN THIS DOCUMENT IS PROVIDED IN CONNECTION WITH DIALOGIC BY ESTOPPEL OR OTHERWISE, TO ANY INTELLECTUAL PROPERTY RIGHTS IS GRANTED BY THIS DOCUMENT. EXCEPT AS PROVIDED IN A SIGNED AGREEMENT BETWEEN YOU AND DIALOGIC, DIALOGIC ASSUMES NO LIABILITY WHATSOEVER, AND DIALOGIC DISCLAIMS ANY EXPRESS OR IMPLIED WARRANTY, RELATING TO SALE AND/OR USE OF DIALOGIC PRODUCTS INCLUDING LIABILITY OR WARRANTIES RELATING TO FITNESS FOR A PARTICULAR PURPOSE, MERCHANTABILITY, OR INFRINGEMENT OF ANY INTELLECTUAL PROPERTY RIGHT OF A THIRD PARTY.
Dialogic products are not intended for use in medical, life saving, life sustaining, critical control or safety systems, or in nuclear facility applications.
It is possible that the use or implementation of any one of the concepts, applications, or ideas described in this document, in marketing collateral produced by or on web pages maintained by Dialogic may infringe one or more patents or other intellectual property rights owned by third parties. Dialogic does not provide any intellectual property licenses with the sale of Dialogic products other than a license to use such product in accordance with intellectual property owned or validly licensed by Dialogic and no such licenses are provided except pursuant to a signed agreement with Dialogic. More detailed information about such intellectual property is available from Dialogic’s legal department at 9800 Cavendish Blvd., 5 Quebec, Canada H4M 2V9. Dialogic encourages all users of its products to
procure all necessary intellectual property licenses required to implement any concepts or applications and does not condone or encourage any intellectual property infringement and disclaims any responsibility related thereto. These intellectual property licenses may differ from country to country and it is the responsibility of those who develop the concepts or applications to be aware of and comply with different national license requirements.
Dialogic, Diva, Eicon, Eicon Networks, Eiconcard, Dialogic Pro and SIPcontrol, among others, are either registered trademarks or trademarks of Dialogic. Dialogic's trademarks may be used publicly only with permission from Dialogic. Such permission may only be granted by Dialogic’s legal department at 9800 Cavendish Blvd., 5th Floor, Montreal, Quebec, Canada H4M 2V9. Any authorized use of Dialogic's trademarks will be subject to full respect of the trademark guidelines published by Dialogic from time to time and any use of Dialogic’s trademarks requires proper acknowledgement. The names of actual companies and products mentioned herein are the trademarks of their respective owners.
®
PRODUCTS. NO LICENSE, EXPRESS OR IMPLIED,
th
Floor, Montreal,

6. Sales Assistance

If you have a sales question, please contact your local Sales Representative or the Regional Sales Office
Loading...