Dialogic D-21H, D-41H User Manual

D/41H & D/2 1H
05-0528
-
002
GroundedStatic-Dissipativ
e
n Configuration n Installation n Warranty Period n RMA Process
n Regulatory Notices
Copyright © 1997
Dialogic Corporation.
All Rights Reserved.
Read Me First
Protect Yourself from Electric Shock
To reduce the risk of electric shock:
n Switch off the power and remove power cords
before opening the PC cover to install the D/41H or D/21H.
n Do not re-attach power cords and switch on power
to the computer while the PC cover is removed.
Protect the Board from Static Electricity
Computer boards are static-sensitive and can be damaged by touching or handling them. To prevent damage from static electricity, do the following:
n Wear a grounded, static-dissipative wrist-strap for
the entire hardware installation.
n Keep the board in its anti-static container when it is
not being handled.
n Work at a static-safe work area (see Figure 1).
Wrist Strap
Ground
Grounded
Static-Dissippative
Mat
Common
Ground
Point
Figure 1. Static-safe work area
A static-safe work area consists of a grounded static­dissipative wrist strap and a work surface covered with or composed of a grounded static-dissipative material. The work surface drains electrical charges from conduc­tive materials when the materials are placed on the sur­face. The grounded static-dissipative wrist strap drains static charge from the person wearing the strap. Both components ensure that static charges are drained at a rate and current level that are safe. Both must be used any time a person is handling any component.
Read Your Software Documentation
Your application software or Dialogic software release (hereinafter collectively called “voice software”) may have special installation or configuration instructions or requirements. Be sure to read all software documentation for any such instructions or requirements.
Installation Order
You can install the D/41H or D/21H and voice software in any order, but Dialogic recommends that you install the voice software first when running in a Windows 95 or Windows NT environment, and the board first in any other operating system environment.
D/41H or D/21H Factory Defaults
You may be able to use the factory defaults when install­ing the D/41H or D/21H board. Read through these instructions and check for possible hardware interrupt level (IRQ) and memory address conflicts between the D/41H or D/21H board and other software or hardware devices (for example, video card or CD ROM controller card) before installing the board.
Note: If you own a software utility that can determine what IRQs and memory addresses are in use, run it to help determine potential conflicts before installing the D/41H or D/21H. Some voice software includes such a software utility, or a separate board configuration utility, to help with the D/41H or D/21H installation and configuration.
D/41H Physical Description
Set the Offset Address (SW 1: 1, 2, 3)
The default offset address for the D/41H and D/21H is
JP7
JP1
JP5/6
SW1
JP101
JP201
JP301
JP401
J1
J2
J3
J4
Part J1–J4
JP1 JP5–JP6
JP7
JP101– JP401
SW1
Function
RJ-11 jacks for interface with PBX or central office (CO) lines *
Jumper block to set interrupt level Jumper pins to set base memory
segment Jumper pins to enable hardware interrupt
circuitry for multiple boards Jumper pins to set ring detection threshold * Switches to set the offset address and default
hook switch state
* J3, J4, JP301, and JP401 are not available
on the D/21H board.
0000H. If you need to change an offset address, set the switches 1, 2, and 3 on SW1 (see Figure 2) as follows:
Offset Address
SW1:1, 2, 3
Top Edge — SW1: Switches —
(Hex) View 1 2 3
0000* (default)
1 2 3 4
off off off
2000*
1 2 3 4
off off on
4000*
1 2 3 4
off on off
Configuring the Hardware
Installing More Than One Voice Board (JP7)
You can install up to 16 D/41H or D/21H boards in a system. One and only one board in a system can have the jumper on JP7 installed (see Figure 2):
n One board: Leave the jumper on JP7 installed
(default).
n Multiple boards: Remove the jumper on JP7 from
all but one board.
1 2 3 4
S
S
S
W
W
W
1
1
:
:
1
2
Figure 2. Top edge view of SW1, JP5/6, JP1, and JP7
Set the Hardware Interrupt Level (JP1)
The default hardware interrupt level setting (IRQ) is IRQ 9 (a jumper on JP1 pins labeled IRQ 2/9 as shown in Figure 2). Change the IRQ by moving the jumper on JP1 to another IRQ setting if IRQ 9 is already in use.
Notes: 1) Set every D/41H, D/21H and compatible
board in the system to the same IRQ level.
2) Although the pins for IRQ 9 are labeled IRQ 2/9, IRQ 2 is not available for this board.
J
J
I
I
I
I
I
I
I
I
I
S
W
1
1
:
:
4
3
R
R
R
R
R
R
P
P
Q
6
Q
5
2
/
9
R
Q
Q
Q
Q
3
Q
4
5
7
J
R
R
P
Q
Q
1
1
1
1
0
0
1
2
Set the Memory Address
6000*
8000
1 2 3 4
1 2 3 4
Each D/41H, D/21H or compatible voice board installed in a computer must have a unique memory address consisting of a base memory address segment and an
A000
1 2 3 4
offset address.
Set the Base Memory Address Segment (JP5 and JP6)
C000
1 2 3 4
The default base memory address segment for the D/41H and D/21H is D000H (Hexadecimal). Generally, you should use the default unless there are more than eight
E000
1 2 3 4
boards in your system or if other non-Dialogic devices in your system must use the D000H segment. Select the base address memory segment with jumpers JP5 and JP6 as follows:
Base Address (Hex)*
D000
7
(default) A000 †
JP6 / JP5
Top Edge View
JP6
JP5
removed removed
removed installed
B000 †
installed installed
C000 ‡
* Be aware of possible conflicts with devices that often use these segments: video adapters; disk controller BIOS.
installed removed
* Base memory address segment B000H does not support offset address settings 0000H – 6000H.
n While you can set only one D/41H or D/21H board
to an offset, you can set multiple boards to consecu­tive offsets within a base memory segment as shown in the following example.
Board Base:Offset (Hex) Lines Board
1
D000:0000
2
D000:2000
3
D000:4000
4
C000:A000
n Write the IRQ level and memory address settings
below for use when installing system software:
IRQ Base Offset Lines/Board
off on on
on off off
on off on
on on off
on on on
1–4 5–6 7–10 11–14
D/41H D/21H D/41H D/41H
Setting the Initial Hook Switch State (SW1:4)
4. Insert the board’s edge connector into the bus slot.
Windows and Windows NT are registered trademarks of Microsoft Corporation.
SW1 switch 4 (SW 1:4 in Figure 2) sets the initial hook switch state for the D/41H and D/21H board. This setting is active only when the PC is powered on but the firmware has not yet been downloaded to the board.
If the initial hook switch state is set to on-hook (default) the board presents an inbound call with a ring no answer state. You can change the initial hook switch state to off­hook to present a busy signal instead.
Once the firmware is downloaded, the hook switch state is set to on-hook, and may only be changed by the application controlling the board.
It is not necessary to set all D/41H or D/21H boards in the system to the same initial hook switch state.
Caller Hears
Ring no answer (default)
Busy
Hook Switch
State
on-hook
off-hook
SW1:4 Top
Edge View
1 2 3 4
1 2 3 4
Set
SW1:4
off
on
Note: If the PC is not powered on, the inbound call response is ring no answer when a board receives a call.
Increasing Ring Detection Threshold Behind a PBX (JP101–JP401)
If a board has problems detecting rings behind a PBX, you can lower the ring detection threshold. To lower the threshold on a channel-by-channel basis, install the jumpers (see D/41H Physical Description) as follows:
Channel 1 Channel 2 Channel 3 Channel 4
Jumper JP101 Jumper JP201 Jumper JP301 Jumper JP401
Note: A lower threshold may be too sensitive for boards connected to the CO and cause false detection of rings.
Installing the Hardware
1. Prepare a static-safe work area, turn off all power to the system, and disconnect the system’s power cords from electrical outlets. See Figure 1.
2. Remove the PC cover.
3. Select an empty ISA expansion bus slot, and remove the slot’s retaining screw and access coverplate.
5. Replace and tighten the retaining screw. Select a new slot and repeat steps 3–5 for each board
you are installing. Replace the PC cover when finished.
Make the Connections
Figure 3. Bracket showing voice ports
n The D/41H and D/21H support a single analog voice
channel per RJ-11 jack (channel 1 corresponds to J1, channel 2 corresponds to J2, and so on). Use RJ-11 connectors and phone cable to connect each voice channel jack to a PBX or the CO (see Figure 3).
n A standard telephone will not function when directly
attached to a D/41H or D/21H RJ-11 jack.
After Installing the Hardware
n Install the voice board software as described in the
documentation provided for the Dialogic software release and operating system in use.
n Test the boards using D40CHK.EXE or other
diagnostic utilities such as UDD (Universal Dialogic Diagnostics) that came with the Dialogic software release for the D/41H and D/21H.
n For specifications and product information, refer to
the Dialogic On-Line Information Retrieval System, 1-800-755-5599 or 1-973-993-1063.
Warranty Period
The D/41H and D/21H boards have lifetime warranties. See the Hardware Limited Warranty card for coverage details.
RMA Process
If you suspect you have a problem board, you can return the board to Dialogic for servicing. The following outlines the procedures that make up the Return Material Authorization (RMA) Process.
1. Check to see if the problem is due to a mistake or oversight in the installation process. Be sure to run the diagnostic utility if you have not already done so.
2. Call Dialogic Technical Support at 1-973-993-1443 to confirm that it is a problem board.
3. Call the RMA coordinator at 1-973-993-3000 x6374. Telephone lines are open from 9 a.m. to 5:30 p.m. EST. Give the board’s serial number (two letters and six digits—located on a label attached to the board) and a brief description of the problem to the RMA coordinator. The RMA coordinator will give you an RMA number and an estimated return date.
4. While observing correct static-handling procedures, disconnect power, cables, and remove the board from the chassis.
5. Repack the board, observing correct static-handling procedures. Place the board in an anti-static container and then put it in a shipping carton using appropriate packing material. Use the original shipping materials if possible. Include diagnostic printouts (for example, D40CHK) when applicable.
6. Write the RMA number on the outside of the box you are shipping (for example, RMA #2973) and send the package to the attention of the RMA number assigned.
7. Ship the board to Dialogic at the following address. Dialogic is not responsible for risk of loss or damage in transit.
Dialogic Corporation
1515 Route 10 Parsippany, New Jersey 07054
Federal Communications Commission (FCC)
FCC Part 15 Rules, Subpart B § 15.105
This equipment has been tested and found to comply with the limits for a Class A digital device, pursuant to Part 15 of the FCC Rules. These limits are designed to provide reasonable protection against harmful interference when the equipment is operated in a commercial environment. This equipment generates, uses, and can radiate radio frequency energy and, if not installed and used in accordance with the instruction manual, may cause harmful interference to radio communications. Operation of this equipment in a residential area is likely to cause harmful interference in which case the user will be required to correct the interference at his own expense.
FCC Part 68 Rules, Subpart § 68.218
The D/41H and D/21H boards are registered with the Federal Communications Commission, which places several restrictions on their use.
1. Connection of this equipment to party lines is subject to state tariffs. Contact your state public service commission for information.
2. This equipment cannot be connected to a coin service (Central Office implemented systems).
3. This equipment complies with Part 68 of the FCC rules. On the mounting bracket (or enclosure) of this equipment is a label that contains, among other information, the FCC Registration Number and Ringer Equivalence Number (REN) for this equipment. The FCC Registration Number is EBZUSA-65588-VM-E and the REN is 1.0B. The Facility Interface Code (FIC) is 02LS2 and the boards use USOC jacks RJ-11C or RJ-14C. There is no Service Order Code (SOC).
NOTE: The REN is used to determine the number of devices you may
connect to your telephone line and still have assurance that all of those devices will ring properly when your number is called. In most, but not all areas, the sum of the RENs of all devices should not exceed five (5.0). To be certain of the number of devices you may connect to your line as determined by the RENs, call your local telephone company and request information on the maximum REN for your calling area.
If requested, the FCC Registration Number and REN must be provided to
the telephone company.
4. The telephone company may make changes in its technical operation or procedures. If these changes affect the use of this equipment, the telephone company is required to give you advance notice.
5. If you experience any trouble with the telephone line during or after installing this equipment, disconnect the equipment from the telephone line to determine if the equipment is causing difficulties. Once the equipment has been disconnected, by either you or the telephone company, do not reconnect it until the problem has been corrected or the Dialogic equipment repaired by Dialogic Corporation as defined below.
6. Any repairs to this equipment must be carried out by Dialogic Corporation or our designated agent. This stipulation is required by the FCC and applies during and after the warranty period. If you suspect the equipment is m alfunc-tioning, check the appropriate part of the manual to see that all installation procedures have been followed correctly.
If checking the installation procedures does not locate the problem,
contact your field service representative or our home office. The home office address is:
Dialogic Corporation
1515 Route 10 Parsippany, NJ 07054 (973) 993-3000
United States
Regulatory Notices
Canadian Department of Communications
CS-03: Equipment Attachment Limitations
CP-01, Part I, Section 10.1
The Canadian Department of Communications label identifies certified equipment. This certification means that the equipment meets certain tele­communications network protective, operational and safety requirements. The Department does not guarantee the equipment will operate to the user’s satisfaction.
Before installing this equipment, users should ensure that it is permissible to be connected to the facilities of the local telecommunications company. The equipment must also be installed using an acceptable method of connection. In some cases, the company’s inside wiring associated with a single line individual service may be extended by means of a certified connector assembly (telephone extension cord). The customer should be aware that compliance with the above conditions may not prevent degradation of service in some situations.
Repairs to certified equipment should be made by an authorized Canadian maintenance facility designated by the supplier. Any repairs or alterations made by the user to this equipment, or equipment malfunctions, may give the telecommunications company cause to request the user to disconnect the equipment.
Users should ensure for their own protection that the electrical ground con­nections of the power utility, telephone lines and internal metallic water pipe system, if present, are connected together. This precaution may be particularly important in rural areas.
CAUTION: Users should not attempt to make such connections themselves, but should contact the appropriate electric inspection authority, or electrician, as appropriate.
CP-01, Part I, Section 10.2
The Load Number (LN) associated to each terminal device denotes the percentage of the total load to be connected to a telephone loop which is used by the device, to prevent overloading. The termination on a loop may consist of any combination of devices subject only to the requirement that the total of the Load Numbers of all the devices does not exceed 100.
Dialogic models D/41H and D/21H have a load number of 5.
Canadian Department of Communications ICES-003 Issue 2:
This Class A digital apparatus meets all requirements of the Canadian Interference-Causing Equipment Regulations.
Cet appareil numérique de la classe A respecte toutes les exigences du Règlement sur le material broilleur du Canada.