Dialight L-810 RTO User Manual

Page 1
Document No: 9100-127-1231-99
Issued: November, 2011
INSTALLATION INSTRUCTIONS and PARTS LIST
SINGLE, DUAL and RETRO FIXTURES
MINI L-810 OBSTRUCTION LIGHT
-------------------------------------------------------------------------------------------------------------------------------------------
5th digit ... x = color last 3 digits ... 001 = Si ngle 002 = Dual 004 = Retro
WARNING:
DE-ENERGIZE CIRCUIT BEFORE INSTALLING OR WORKING ON FIXTURE
The light assembly fixture can be mounted in any position. When mounted 'upright' [as illustrated] the fixture will meet the designed optical specifications for Aircraft Obstruction Warnings. When mounted in any other meet the designed optical specifications mentioned and will be considered as a visual signal fixture.
position, the fixture will not
SINGLE FIXTURE INSTALLATION STEPS:
The wire housing 2A has a 1” NPT [3/4" bushing] end to be assembled to
conduit [right angle or vertical]
Use a 1-1/2” wrench to tighten and attach the wire housing 2A to the conduit Remove reducing bushing 5 if threading into 1” NPT conduit Use 1” NPT plug 4 to close threaded opening not being used
Feed the supply wires through the conduit and wire housing 2A leaving
approx 6” of wire for termination inside the wire housing 2A .
Electrically connect the supply wires to the light assembly 1 wires
Connect the light assembly wire [with voltage label]
to the Hot AC line or Positive [+] line
Connect the light assembly wire [without label]
to the Neutral AC line or Negative [-] line
Connect the light assembly green grounding wire to the Ground line
Tuck the connected wires inside the wire housing 2A .Position light assembly 1 over the wire housing 2A and secure using the holding screws 3 .Restore power and verify operation
Sheet 1 of 2
DUAL FIXTURE INSTALLATION STEPS:
The dual housing 2B has a 1” NPT end to be assembled to conduit
Remove reducing bushing 5 if threading into 1” NPT conduit Use a 1-1/2” wrench to tighten and attach the dual housing 2B to the conduit Tighten the 1/4 screw 3 to secure the dual wire housing in position
Feed the supply wires through the conduit and dual housing 2B leaving
approx 6” of wire for termination inside the wire housing 2B .
Electrically connect the supply wires to the light assembly 1 wires
same as SINGLE FIXTURE installation
Tuck the connected wires inside the dual housing 2B .Position each light assembly 1 over the dual housing 2B and use
the holding screws 3 to secure the light assembly in place
► Restore power and verify operation
-------------------------------------------------------------------------------------------------------------------------------------------
1501 Route 34 South, Farmingdale, NJ 07727 Tel: [732] 919-3119 Fax: [732] 751-5778 www.dialight.com
Page 2
INSTALLATION INSTRUCTIONS and PARTS LIST
SINGLE, DUAL and RETRO FIXTURES
MINI L-810 OBSTRUCTION LIGHT
-------------------------------------------------------------------------------------------------------------------------------------------
RETRO INSTALLATION STEPS:
► Remove existing lens and clamp 6 from existing fixture ► Do not discard clamp 6 since it will be used to secure light assembly 1A . ► Remove and discard all internal components required for use with incandescent bulb ► Leave only the source wires that le
ad into the existing base 2C .
Electrically connect the supply wires to the light assembly 1A wires
same as SINGLE FIXTURE installation
Tuck the connected wires inside the existing base 2C . ► Place light assembly 1A on existing base 2C and secure using existing clamp 6 . ► Restore power and verify operation
RETRO ONTO 3/4-14 NPT CONDUIT INSTALLATION STEPS:
Electrically connect the supply wires to the light assembly 1A wires
same as SINGLE FIXTURE installation
Use a 1-1/4” wrench to tighten and attach the light assembly 1A to the conduit ► Restore power and verify operation
Document No: 9100-127-1231-99
Issued: November, 2011
Sheet 2 of 2
Please refer to product data sheet for electrical parameters if required
Single Housing Fixture Dual Housing Fixture Retro Fixture [Housing] Retro Fixture [Conduit]
Patent Pending
PARTS LIST
Item Part No. Description Item Part No. Description
1 . Light Assembly (w/ Adapter) 3 . 1/4-20 x ½ Holding Screw 1A . Light Assembly (w/o Adapter) 4 . 1” Plug 2A 860-1000 Single Housing 5 . 1” to 3/4" Bushing 2B 860-2000 Dual Housing 6 . Existing Installed Clamp 2C . Existing Installed Housing . .
Rev ECO No Drn Chk App CM Date
E 5156 AV ALV SM JB 12-2-11
-------------------------------------------------------------------------------------------------------------------------------------------
1501 Route 34 South, Farmingdale, NJ 07727 Tel: [732] 919-3119 Fax: [732] 751-5778 www.dialight.com