DeWalt D55153 TYPE 3 Owner’s Manual

If you have questions or comments, contact us.
Pour toute question ou tout commentaire, nous contacter.
Si tiene dudas o comentarios, cont&ctenos.
iNSTRUCTiON MANUAL
GUIDE D'UTILiSATION MANUAL DE INSTRUCCIONES
INSTRUCTIVO DE OPERACION, CENTROS DE SERVICIO Y POLIZA DE GARANTiA. ADVERTENClA: LI_ASE ESTE INSTRUCTIVO ANTES DE USAR EL PRODUCTO.
D55151, D55152, D55153, D55155
Contractor's Electric 4 Gallon Hand Carry Air Compressor Compresseurs d'air portatifs 61ectriques de 4 gallons de classe entrepreneur Compresor de aire portatil electrico de 4 galones para contratistas
®
Air Compressor
A. On/Off Switch
B. Air Tank Pressure Gauge
C. Regulated Pressure Gauge
D. Pressure Regulator E. Quick Connects (if equipped)
F. Check Valve
G. Safety Valve
H. Air Tank Drain Valve
I. Power Cord Wrap
J. Pressure Switch
K. Pump Oil Dipstick
L. Pump Oil Drain Plug
M. Motor Reset
N. Air Intake Filter
FIG. 1
NOT A
B
STEP
D
B
A
K
A
C
D
M
2
Specifications
MODEL D55155
D55152
!
WEIGHT 56 Ibs. (25.4 kg) 58 Ibs. (28.3 kg) 61 Ibs. (27.7 kg)
HEIGHT 16.75" (425.5 mm) 16.75" (501.7 mm) 12.5" (317.5 mm)
WIDTH 18.0" (457.2 mm) 18.0" (457.2 mm) 21.75" (552.5 mm)
LENGTH 15.0 (381 mm) 15.0 (381 mm) 21.75" (552.5 mm)
AIRTANK CAPACITY (GALLONS) 4.0 (15.1 liters) 4.0 (15.1 liters) 4.0 (15.1 liters) APPROX CUT=INPRESSURE 95 PSi (655 kPa) 95 PSi (655 kPa) 100 PSi (689.5 kPa) APPROX. CUT=OUT PRESSURE 125 PSi (861.8 kPa) 125 PSi (861.8 kPa) 125 PSi (861.8 kPa)
SCFM @ 100 PSI (689.5 kPa) 3.2 3.8 4.5 MOTOR 1.1 HP (continuous) 1.1 HP (continuous) 1.2 HP (continuous)
Volts/Amps/Hertz 120V/12.5 A/60 Hz. 120V/14 A/60 Hz. 120V/15 A/60 Hz.
RPM 3450 3450 3450 Minumum Branch Circuit 15 Amp 15 Amp 15 Amp
Requirement
PUMP OIL CAPACITY 6 oz. (177.4 ml) 12 oz. (354.9 ml) 12 oz. (354.9 ml) 4 oz. (118.3 ml)
65 Ibs. (29.5 kg)
16.0" (406.4 ram)
18.0" (457.2 ram)
18.0" (457.2 ram)
4.0 (15.1 liters) 95 PSI (655 kPa) 125 PSI (861.8 kPa)
3.8
1.1 HP (continuous) 120V/14 A/60 Hz.
3450 15 Amp
Hot Surfaces
FIG.2 CYLNDER
OUTLET TUBE CHECK /
PUMP
AND
VALVE /
Definitions: Safety Guidelines
The definitions below describe the level of severity for each signal word. Please read the manual and pay attention to these symbols.
`&DANGER: Indicates an imminently hazardous
situation which, ff not avoided, wifl result in death or serious injury.
AWARNING: Indicates a potentially hazardous situation which, ff not avoided, could result in death
or serious injury. ,&CAUTION: Indicates a potentially hazardous
situation which, ff not avoided, may result in minor or moderate injury.
CAUTION: Used without the safety alert symbol indicates a potentially hazardous situation which, ff not avoided, may result inproperty damage.
OUTLET TUBE VALVE
CHECK
IF YOU HAVE ANY QUESTIONS OR COMMENTS ABOUT
THIS OR ANY DEWALT TOOL, CALL US TOLL FREE AT:
I=800=4=DEWALT (1-800=433=9258)
Important Safety Instructions
_, WARNING: Do not operate this unit until you read and understand
this instruction manual for safety, operation and maintenance instructions.
AWARNING: Some dust created by power sanding, sawing, grind- ing, drilling, and other construction activities contains chemicals known to the State of California to cause cancer, birth defects or other reproductive harm. Some example of these chemicals are:
* lead from lead-based paints * crystalline silica from bricks and cement and other masonry
products
* arsenic and chromium from chemically-treated lumber
Your risk from these exposures varies, depending on how often you do this type of work. To reduce your exposure to these chemi-
cals: work in a weft ventilated area, and work with approved safety equipment, always wear OSHA/MSHA/NIOSH approved, properly
fitting face mask or respirator when using such tools.
When using air tools, basic safety precautions should always be fol- lowed to reduce the risk of of personal injury,
_ WARNING: This product contains chemicals, including lead, known to the State of California to cause cancer, and birth
defects or other reproductive harm. Wash hands after handling.
SAVE THESE INSTRUCTION
,t_DANGER: RISK OF EXPLOSION OR FIRE
WHAT CAN HAPPEN HOWTO PREVENT iT
It is normal for electrica! _ Always operate the compres_ contacts within the motor Sorin a well ventilated area
and pressure switch to free of combustible materials,
spark, gasoline, or solvent vapors.
If electrical sparks from If spraying flammable materi- compressor come into con- als, locate compressor at tact with flammable vapors, east 20 feet 16.1 m) away they may ignite, causing fire from spray area. An addi- or explosion, tional length of hose may be
required.
- Store flammable materials q a secure location away from
compressor.
Restricting any of the com- Never place objects against pressor ventilation openings or on top of compressor
will cause serious overheat- Operate compressor in ing and could cause fire. an open area at least 12"
(30.5 cm) away from any wall or obstruction that would
restrict the flow of fresh air to
the ventilation openings.
Operate compressor in a clean, dry well ventilated area.
Do no_operate unit indoors or
in any confined area.
Unattended operation of
this product could result in
personal injury or property damage. To reduce the risk of fire, do not allow the
compressor to operate unat- tended.
ADANGER: RISK TO BREATHING (ASPHYXIATION)
WHAT CAN HAPPEN HOWTO PREVENTIT
, The compressed air directly - Air obtained directly from the
from your compressor is not compressor should never safe for breathing. The air be used to supply air for
stream may contain carbon human consumption. In order monoxide, toxic vapors, to use air produced by this
or solid particles from the compressor for breathing air tank. Breathing these suitable filters and in-line
contaminant's can cause safety equipment must be serious injury or death, properly installed. In-line
Always remain in attendance with the product when it is
operating.
Always turn off and unplug
unit when not in use.
filters and safety equipment
used in conjunction with the
compressor must be capable of treating air to all applicable
local and federal codes prior to human consumption
Sprayedmaterialssuchas paint,paintsolvents,paint
remover,insecticides,weed killers,maycontainharmful
vaporsandpoisons.
Workinanareawithgood crossventilation.Readand
followthesafetyinstructions providedonthelabelorsafety
datasheetsforthematerials youarespraying.Alwaysuse
certifiedsafetyequipment: OSHA!MSHA/NIOSH
respiratoryprotectiondesigned forusewithyourspecific application.
_&DANGER:RISK OF INJURY OR PROPERTY DAMAGE WHEN
TRANSPORTING OR STORING
WHAT CAN HAPPEN HOWTO PREVENTIT
o Oil can leak or spilland could - Always place compressor
result infire or breathing on a protective mat when hazard; serious injury or transporting to protect against death can result.Oil leaks will damage to vehicle from leaks. damage carpet, paint or other Remove compressor from surfaces in vehicles ortrailers, vehicle immediately upon arrival
at your destination. Always keep compressor level and never lie
on its side.
_&WARNING: RISK OF BURSTING
AirTank: The airtank on your Air Compressor is designed and may be UM coded (for units with air tanks greater than 6 inch diameter) according to ASME Section VIII, Div. 1 rules. All pressure vessels should be inspected once every two years.To find your state pressure vessels inspector, look under the Division of Labor and Industries in the government section of a phone book or call 1-800-4-DEWALT for
assistance. The following conditions could lead to a weakening of the air tank,
and result in a violent air tank explosion:
WHAT CAN HAPPEN HOWTO PREVENT IT
Failure to properly drain _ Drain airtank daily or after
condensed water from air tank. causing rust and
thinning of the steel air tank.
Modifications or attempted - Never drill into.weld, or make repairs to the air tank, any modifications to the air
Unauthorized modifications
The airtank is designed to the safety valve or any other components which control air tank pressure.
each use. If air tank develops a leak. replace it immediately with a new air tank or replace the entire compressor.
tank or its attachments. Never
attempt to repair a damaged or leaking air tank. Replace with a
new airtank.
to withstand specific operating pressures. Never
make adjustments or parts substitutions to alter the factory set operating pressures.
Attachments& accessories:
Exceeding the pressure Follow the equipment rating of air tools, spray guns. manufacturers air operated accessories, recommendation and never
tires, and other inflatables exceed the maximum
can cause them to explode allowable pressure rating or fly apart, and could result of attachments. Never use in senous injury, compressor to inflate small
low pressure objects such as children's toys, footballs,
basketballs, etc.
AWARNING: RiSK OF ELECTRICAL SHOCK
WHAT CAN HAPPEN HOWTO PREVENT iT
" Youiair c0mpress0r is . Never operate the
powered bY electricity, compressor outdoors when it
Like any other electrically is raining 0r in wet conditions. powered device, !fit iS not ,, Never operate comPressor
used proper!y it may cause with protective covers electric shock, removed or damaged.
Repairs attempted by unqualified personnel can result in serious injury or death by electrocution.
Any electrical wiring or repairs required on this product should be performed by a DEWALTfactory
service center or a DEWALT authorized service center in
accordance with national and local electrical codes.
- Electrical Grounding: = Make certain that the Failure to provide adequate electrical circuit to which the grounding to this product compressor is connected could result in serious injury provides proper electrical or death from electrocution, grounding, correct voltage See Grounding and adequate fuse protection.
instructions under
Installation.
AWARNING: RISK FROM FLYING OBJECTS
WHAT CAN HAPPEN
The compressed air stream can cause soft tissue
damage to exposed skin and can propel dirt, chips, loose particles, and small objects at high speed, resulting in property damage or personal injury.
HOWTO PREVENT IT
Always wear certified safety equipment: ANSI Z87.1 eye protection (CAN/CSA Z94.3) with side shields when using the compressor.
Never point any nozzle or sprayer toward any part of the body or at other people or
animals. Always turn the compressor off
and bleed pressure from the air hose and air tank before
attempting maintenance, attaching tools or accessories.
AWARNING:RiSK OF HOT SURFACES
WHAT CAN HAPPEN HOWTO PREVENT JT
Touching exposed metal - Never touch any exposed
such as the compressor metal parts on compressor
head. engine head, engine during or immediately after
exhaust or outlet tubes, can operation. Compressor will
result in serious burns, remain hot for several minutes
after operation.
Do not reach around protective shrouds or attempt
maintenance until unit has been allowed to cool.
_, WARNING: RiSK FROM MOVING PARTS
WHAT CAN HAPPEN HOWTO PREVENT IT
Moving parts such as the pulley, flywheel, and belt can
cause serious injury ifthey come into contact with you or
your clothing.
Never operate the compressor with guards or covers which
are damaged or removed.
Keep your hair, clothing, and
gloves away from moving parts. Loose clothes, jewelry,
or long hair can be caught in moving parts.
Air vents may cover moving
parts and should be avoided as well.
- Attempting to operate o Any repairs required on this compressor with damaged or product should be performed
missing parts or attempting by a DEWALTfactory
to repair compressor with service center or a DEWALT
protective shrouds removed authorized service center.
can expose you to moving
parts and can result in
serious injury.
AWARNING: RISK OF UNSAFE OPERATION
WHAT CAN HAPPEN HOWTO PREVENT IT
Unsafe operation of your air
compressor could lead to seri- ous injury or death to you or
others.
Review and understand all
instructions and warnings in this manual.
Become familiar with the operation and controls of the
air compressor.
Keep operating area clear of all persons, pets, and obstacles.
Keep children away from the air compressor at all times.
Do not operate the product when fatigued or under the
influence of alcohol or drugs. Stay alert at alltimes.
Never defeat the safety fea- tures ofthis product.
Equipareaofoperationwitha fireextinguisher.
Donotoperatemachinewith missing,broken,orunautho- rizedparts.
WARNING: RiSK OF FALLING
WHAT CAN HAPPEN HOWTO PREVENTIT
A portable compressor _ Always operate compressor can fall from a table, in a stable secure position to workbench, or roof causing prevent accidental movement damage to the compressor of the unit. Never operate and could result in serious compressor on a roof or
njury or death to the other elevated position. Use
operator, additio nal air hose to reach
high locations.
A CAUTION: RISK FROM NOISE
WHAT CAN HAPPEN HOWTO PREVENT IT
Under some conditions and Always wear certified safety duration of use, noise from equipment: ANSI S12.6 this product may contribute (S3.19) hearing protection. to hearing loss.
SAVE THESE INSTRUCTIONS
FOR FUTURE USE
FEATURES (Fig. 1)
ON/OFF SWITCH Place this switch (A) in the ON position to
provide automatic power to the pressure
switch and OFF to remove power at the
end of each use. PRESSURE SWITCH
The pressure switch (J) automatically starts the motor when the air tank pres- sure drops below the factory set cut-in
pressure. It stops the motor when the air tank pressure reaches the
factory set cut-out pressure.
PRESSURE RELEASE VALVE
The pressure release valve located on the side of the pressure switch,
is designed to automatically release compressed air from the compres- sor head and the outlet tube when the air compressor reaches cut-out pressure or is shut off.The pressure release valve allows the motor to
restart freely.When the motor stops running, air will be heard escaping from this valve for a few seconds. No air should be heard leaking when the motor is running orafter the unit reaches cut-out pressure.
SAFETY VALVE
If the pressure switch does not shut off the air compressor at its cut-out pressure setting, the safety valve (G) will protect against
high pressure by popping out at its factory set pressure (slightly
higher than the pressure switch cut-out setting).
CHECK VALVE When the air compressor is operating, the check
valve (F) is open, allowing compressed air to enter the air tank. When the air compressor reaches cut-
out pressure, the check valve closes, allowing air
pressure to remain inside the air tank.
TANKPRESSUREGAUGE Thetankpressuregauge(B)indi-
catesthereserveairpressurein thetank.
OUTLETPRESSUREGAUGE Theoutletpressuregauge(C)
indicatestheairpressureavailable attheoutletsideoftheregulator. Thispressureiscontrolledbytheregulatorandisalwayslessthan orequaltothetankpressure.
REGULATOR Theregulator(D)controlstheairpressureshownontheoutlet
pressuregauge.Turnregulatorknobclockwisetoincreasepres- sureandcounterclockwisetodecreasepressure.
UNIVERSALQUICKCONNECTBODIES(IFEQUIPPED) Theuniversalquickconnectbody(E)acceptsthethreemost
popularstylesofquickconnectplugs:Industrial,automotive,and ARO.Onehandpush-to-connectoperationmakesconnections simpleandeasy.Thetwoquickconnectbodiesallowtheuseoftwo
toolsatthesametime.
DRAIN VALVE
The drain valve (H) is located at the base of the air tank and is used to drain conden-
sation atthe end of each use. See Draining Air Tank under Maintenance.
COOLING SYSTEM This compressor contains an advanced design cooling system.
It is normal for this fan to blow air through the vent holes in large amounts. The cooling system is working when air is expelled.
AIR COMPRESSOR PUMP
The pump compresses air into the air tank. Working air is not
available until the compressor has raised the air tank pressure above that required at the air outlet.
MOTOR OVERLOAD PROTECTOR
This motor has a manual thermal overload
protector. If the motor overheats for any reason, the overload protector will shut off
the motor. The motor must be allowed to
cool down before restarting. To restart:
1. Ensure the On/Off switch (A) is in the OFF position.
2. Allow the motor to cool.
3. Depress the reset button (M) on the motor.
OIL DIPSTICK
The oil dipstick (K) indicates the amount of oil in the pump. Check
pump oil daily, see Compressor Pump Oil under Maintenance. AIR iNTAKE FILTER
The filter (N) is designed to clean air entering the pump. To ensure the pump continually receives a clean, cool, and dry air supply the filter must always be clean and the filter intake must be free from
obstructions.
INSTA£LATION
Assembly
iNSTALLING HOSES
WARNING: Risk of unsafe operation. Firmly grasp hose in hand
when installing or disconnecting to prevent hose whip.
lO
1. Ensure regulated pressure gauge reads 0 PSI (0 kPa).
2. Grasp the hose at the quick connect plug and push the plug into the quick connect body (E). Coupler will snap into place.
3. Grasp the hose and pull to ensure coupler is seated.
DISCONNECTING HOSES
Ik WARNING: Risk of unsafe operation. Firmly grasp hose in hand when installing or disconnecting to prevent hose whip.
1. Ensure regulated pressure gauge reads 0 PSi (0 kPa).
2. Pull coupler on quick connect body back to release quick connect plug on hose.
Lubrication and Oil
CAUTION: The compressor was shipped with oil in the crankcase.
A shipping plug is used to prevent oil from leaking during shipment. Do not attempt to operate this air compressor without first checking
the oil level. Serious damage can result from even limited operation unless filled with oil and broken in correctly. Closely follow Initial
Set-up under Operation. CAUTION: Multi-viscosity motor oils, like 10W30, should not be
used in an air compressor. They leave carbon deposits on critical components, thus reducing performance and compressor like. Use
SAE 40, non-detergent air compressor oil only.
1. Place unit on a level surface.
2. Remove the shipping plug and install the dipstick.
3. Remove the dipstick (K) and check the oil level. Oil should not exceed top raised line on dipstick. If oil is below lower mark see Checking Oil under Compressor Pump Oil under Maintenance. NOTE: See Specifications for _ pump oil capacity.
CAUTION: Risk of unsafe operation. Overfilling with oil will cause premature compressor failure. Do not overfill.
4. Replace dipstick.
Grounding instructions
_&WARNING: Risk of electrical shock. In the event of a short circuit, grounding reduces the risk of shock by providing an escape wire for the electric current. This air compressor must be properly grounded.
The portable air compressor is equipped with a cord having a grounding wire with an appropriate grounding plug.
1. The cord set and plug (0) with this unit contains a grounding pin (P).This plug MUST be used with a grounded outlet (Q).
IMPORTANT: The outlet being used must be installed and grounded in accordance
with all local codes and ordinances.
2. Ensure the outlet being used has the same configuration as the grounded plug. DO NOT USE AN ADAPTER.
3. Inspect the plug and cord before each use. Do not use if there are signs of damage.
4. If these grounding instructions are not completely understood, or if in doubt as to whether the compressor is properly grounded, have the installation checked by a qualified electrician.
_DANGER: Risk of electrical shock. IMPROPER GROUNDING
CAN RESULT IN ELECTRICAL SHOCK.
* Do not modify the plug provided, ff it does not fit the available
outlet, a correct outlet should be installed by a quafified electri- cian.
* Repairs to the cord set or plug MUST be made by a quafified
electrician.
11
Extension Cords
Using extension cords is not recommended. The use of extension cords will cause voltage to drop resulting in power loss to the motor and overheating.
Instead of using an extension cord, increase the working reach of the air hose by attaching another length of hose to its end. Attach additional lengths of hose as needed. If an extension cord must be used, be sure it is:
a 3-wire extension cord that has a 3-blade grounding plug, and a 3-slot receptacle that will accept the plug on the product
in good condition
no longer than 50 feet (15,2 m)
12 gauge (AWG) or larger. (Wire size increases as gauge num- ber decreases. 10 AWG and 8 AWG may also be used. DO NOT USE 14 OR 16 AWG.)
Voltage and Circuit Protection
Refer to the Voltage and Minimum Branch Circuit Requirements under Specifications.
_,CAUTION: Certain air compressors can be operated on a
15 amp circuit if the following conditions are met.
Voltage supply to circuit must comply with the National Electrical
Code.
Circu# is not used to supply any other electrical needs.
Extension cords comply with specifications. Circu# is equipped with a 15 amp circu# breaker or 15 amp
time delay fuse. NOTE: ff compressor is connected to a circu#
protected by fuses, use only time delay fuses. Time delay fuses should be marked "D" in Canada and "T" in the US.
If any of the above conditions cannot be met, or ff operation of the compressor repeatedly causes interruption of the power, it may be necessary to operate it from a20 amp circuit. It is not necessary to change the cord set.
Compatibility
Air tools and accessories that are run off the compressor must be compatible with petroleum-based products. If you suspect that a material is not compatible with petroleum products, an air line filter for removal of moisture and oil vapor in compressed air is required.
NOTE: Always use an air line filter to remove moisture and oil vapor when spraying paint.
Location
Place the air compressor in a clean, dry and well ventilated area at least 12" (30.5 cm) away from the wall or other obstructions that will interfere with the flow of air. Keep the compressor away from areas that have dirt and/or volatile fumes in the atmosphere. These impurities may clog the intake filter and valves, causing inefficient operation.
The air compressor pump and shroud are designed to allow for proper cooling. The ventilation openings on the compressor are necessary to maintain proper operating temperature. Do not place rags or other containers on or near these openings.
Place the air compressor on a flat surface resting on the rubber feet.
NOISE CONSIDERATIONS Consult local officials for information regarding acceptable noise
levels in your area. To reduce excessive noise, use vibration mounts or silencers, relocate the unit or construct total enclosures or baffle
walls. Contact a DEWALT service center or call 1-800-4-DEWALT for assistance.
12
ELECTRICAL Refer to all safety instructions before using unit. Observe extension
cord safety instructions if necessary. Always move the On/Off switch (A) to the OFF position before removing the plug from the
outlet.
TRANSPORTING
When transporting the compressor in a vehicle, trailer, etc., ensure
that the tank is drained and the unit is secured. Use care when driv-
ing to avoid tipping the unit over in the vehicle. Damage can occur to
the compressor or surrounding items if the compressor is tipped.
MOVING
When moving the compressor, grasp the handle and carry the com- pressor as close to the body as possible.
_, WARNING: Risk of unsafe operation. Ensure proper footing and
use caution when carrying compressor to avoid a loss of balance.
PREPARATION FOR USE Pre-Start Checklist (Fig. 1)
1. Ensure the On/Off switch (A) is in the OFF position.
2. Plug the power cord into the correct branch circuit receptacle. See Voltage and Circuit Protection under Installation.
3. Ensure air tank is drained, see Draining Air Tank under
Maintenance.
4. Ensure the drain valve (H) is closed.
5. Ensure safety valve (G) is functioning properly, see Checking Safety Valve under Maintenance.
6. Check pump oil level, see Compressor Pump Oil under
Maintenance.
CAUTION: Do not operate without oil or with inadequate oil.DEWALT
is not responsible for compressor failure caused by inadequate oil.
7. Turn regulator knob (D) counterclockwise until fully closed. Ensure regulated pressure gauge reads 0 PSI (0 kPa).
8. Attach hose and accessories.
_kWARNING: Risk of unsafe operation. Firmly grasp hose in hand
when installing or disconnecting to prevent hose whip.
9. Ensure all covers and labels are in place, legible (for labels) and securely mounted. Do not use compressor until all items have
been verified.
, WARNING: Risk of bursting. Too much air pressure causes a
hazardous risk of bursting. Check the manufacturer's maximum pressure rating for air tools and accessories. The regulator outlet pressure must never exceed the maximum pressure rating.
Initial Set.up (Fig. 1)
WARNING: Do not operate this unit until you read and understand
this instruction manual for safety, operation and maintenance
instructions.
BREAK-IN PROCEDURE
_kWARNING: Serious damage may result if the following break-in
instructions are not closely followed.
This procedure is required before the air compressor is put into service for the first time and when the check valve or a compressor pump/motor has been replaced.
1. Ensure the On/Off switch (A) is in the OFF position.
NOTE: If hose is not connected to Quick Connect body, pull coupler back until it clicks to prevent air from escaping through the quick
connect.
2. Plug the power cord into the correct branch circuit receptacle. See Voltage and Circuit Protection under Installation.
13
3. Open the drain valves (counter-clockwise) fully to permit air to escape and prevent air pressure build up in the air tank during the break-in period.
4. Move the On/Off switch to the ON position. The compressor will start.
5. Run the compressor for 20 minutes.
6. After 20 minutes, close the drain valves by turning clockwise. The tank will fill to cut-out pressure and the motor will stop.
7. Compressed air will be available until itis used or bled off.
OPERATING PROCEDURES Start-up (Fig. 1)
1. Follow Pre-Start Checklist under Preparation for Use.
2. Move the On/Off switch to the ON position and allow tank pres- sure to build. Motor will stop when tank pressure reaches cut-out pressure.
CAUTION: Risk of unsafe operation. Compressed air from the unit may contain water condensation and oil mist. Do not spray unfil- tered air at an item that could be damaged by moisture. Some air operated tools or devices may require filtered air. Read the instruc-
tions for the air tool or device.
3. Adjust regulator (D) to desired setting. See Regulator under
Features.
Shut-down (Fig. 1)
1 Move On/Off switch (A) is in the OFF position. NOTE: If finished
using compressor, follow Steps 2 - 6.
2. Turn regulator knob (D) counterclockwise until fully closed. Ensure
regulated pressure gauge reads 0 PSI (0 kPa).
3. Remove hose and accessory.
4. Drain the air tank, see Draining Air Tank under Maintenance. Ensure air tank pressure gauge reads 0 PSI (0 kPa).
_, WARNING: Risk of bursting. Drain air tank daily. Water will con-
dense in air tank. If not drained, water will corrode and weaken the air tank causing a risk of air tank rupture.
5. Allow the compressor to cool down.
6. Wipe air compressor clean and store in a safe, non-freezing area.
MAINTENANCE
The following procedures must be followed when maintenance or service is performed on the air compressor.
1. Ensure On/Off switch is in the OFF position.
2. Remove air compressor plug from outlet.
3. Drain air tank.
4. Allow air compressor to cool down before starting service.
NOTE: All compressed air systems contain maintenance parts (e.g.,
oil, filters, separators) that are periodically replaced. These used parts
may contain substances that are regulated and must be disposed of in
accordance with local, state, and federal laws and regulations.
NOTE: Take note of the positions and locations of parts during
disassembly to make reassembly easier.
NOTE: Any service operations not included in this section should be performed by a DEWALT factory service center or a DEWALT authorized service center.
14
Maintenance Chart
Procedure Daily Weekly IVlonthly
Check safety valve X Inspect air filter + X
Drain air tank X Check pump oil level X
Change pump oil**+ Oil leak inspection X
Check for unusual noise! vibration
Check for air leaks* X Clean compressor exterior X
X
* To check for air leaks apply a solution of soapy water around joints. While compressor is pumping to pressure and after pressure cuts out, look for air bubbles to form.
** The pump oil must be changed after the first 20 hours of operation. Thereafter, when using DEWALT synthetic or SAE 40, non-detergent air compressor oil, change oil every 200 hours of operation or once a year,
whichever comes first.
+ Perform more frequent !ndusty or humid condit!ons
1 year or
200 Hours
Checking Safety Valve (Fig. 1)
_WARNING: Hot surfaces. Risk of burn. Aftercooler, pump head, and surrounding parts are very hot, do not touch (see the Hot
Surfaces identified in Fig. 2). Allow compressor to cool prior to servicing.
_WARNING: Risk of bursting, ff the safety valve does not work
properly, over-pressurization may occur, causing air tank rupture or an explosion.
Before starting compressor, pull the ring on the safety valve to make sure that the safety valve operates freely. If the valve is stuck or does not operate smoothly, it must be replaced with the same type of valve.
Checking Air Filter Element (Fig. 1)
_,WARNING: Hot surfaces. Risk of burn. Aftercooler, pump head, and
surrounding parts are very hot, do not touch (see the Hot Surfaces identified in Fig. 2). Allow compressor to cool prior to servicing.
1. Ensure the On/Off switch (A) is in the OFF position.
2. Allow unit to cool.
3. Remove air filter (N) from unit.
4. Carefully pry filter top from base.
5. Remove element from filter base.
6. If element needs cleaning, blow out with air. Replace if needed. Purchase replacement parts from your local dealer or authorized service center. Always use identical replacement parts.
7. Place element back in filter base.
8. Snap filter top to filter base.
9. Reassemble air filter to unit. Ensure exhaust outlet points down.
_CAUTION: Risk of unsafe operation. Do not operate without air
inlet filter
Draining Air Tank (Fig. 1)
_kWARNING: Risk of unsafe operation. Risk from noise. Air tanks
contain high pressure air. Keep face and other body parts away from outlet of drain. Use safety glasses [ANSI Z87.1 (CAN/CSA Z94.3)]
when draining as debris can be kicked up into face. Use ear protection [ANSI $12.6 ($3.19)] as air flow noise is loud when
draining.
15
NOTE: All compressed air systems generate condensate that accumulates in any drain point (e.g. tanks, filter, aftercoolers, dryers). This condensate contains lubricating oil and/or substances which may be regulated and must be disposed of in accordance with local, state, and federal laws and regulations.
1. Ensure On/Off switch is in the OFF position.
2. Move compressor into an inclined position so drain valve (H) is at the lowest point (this will assist in removing moisture, dirt, etc. from air tanks)
3. Place a suitable container under the drain valve to catch discharge.
4. Grasp knurled knob on drain valve.
5. Slowly rotate knob to gradually bleed air from air tank.
_, WARNING: Risk of bursting. Drain air tank daily. Water will con-
dense in air tank. ff not drained, water will corrode and weaken the air tank causing a risk of air tank rupture.
CAUTION: Risk of property damage. Drain water from air tank may contain oil and rust, which can cause stains.
6. When air tank pressure gauge reads 10 PSi (68,9 kPa), rotate valve to the fully open position.
7. Close drain valve when finished.
Compressor Pump Oil (Fig. 1)
CHECKING OiL &WARNING: Hot surfaces. Risk of burn. Aftercooler, pump head,
and surrounding parts are very hot, do not touch (see the Hot Surfaces identified in Fig. 2). Allow compressor to cool prior to servicing.
1. Ensure On/Off switch is in the OFF position.
2. Place unit on a flat level surface.
3. Remove dipstick (K) and wipe clean.
4. Reinsert dipstick fully into oil fill port for a few seconds to allow oil to collect on the dipstick. K
5. Remove oil dipstick to read oil level. Oil should not exceed top raised line on dipstick. If oil is below lower mark, add SAE 40, non-detergent air compressor oil and follow Steps 4 - 6.
NOTE: When filling the crankcase, the oil flows very slowly into the pump. If the oil is added too quickly, it will overflow and appear
to be full.
_,CAUTION: Risk of unsafe operation. Overfilling with
oil will cause premature compressor failure. Do not overfill.
6. Replace dipstick.
CHANGING OiL NOTE: Pump oil contains substances that are MAX,
regulated and must be disposed of in accordance with local, state and federal laws and regulations. MIN-
_&WARNING: Hot surfaces. Risk of burn. Aftercooler, pump head,
and surrounding parts are very hot, do not touch (see the Hot Surfaces identified in Fig. 2). Allow compressor to cool prior to servicing.
1. Ensure On/Off switch is in the OFF position.
2. Allow the unit to cool.
3. Remove air compressor plug from outlet.
4. Drain air tank.
5. Locate a suitable container under pump drain plug (L).
6. Remove the dipstick (K) from crankcase.
7. Remove the oil drain plug (L).
8. Allow ample time for all oil to drain out. (Tilting the compressor towards the drain plug will assist in draining.)
16
9.Installtheoildrainplug.
10.FillpumpwithSAE40,non-detergentaircompressoroil.
11.Replacedipstick.
ACCESSORIES
Recommended accessories for use with your tool are available for purchase from your local dealer or authorized service center.
If you need assistance in locating any accessory for your tool, please contact DEWALT Industrial Tool Co., 701 East Joppa Road,
Baltimore, MD 21286, call 1-800-4-DEWALT (1-800-433-9258) or visit our website www.dewalt.com.
_kCAUTION: The use of any other accessory not recommended for
use with this tool could be hazardous. Use only accessories rated equal to or higher than the rating of the air compressor.
SERP'IC_ INFORMATION
Please have the following information available for all service calls: Model Number Serial Number
Date and Place of Purchase
Repairs
To assure product SAFETY and RELIABILITY, repairs, maintenance and adjustment should be performed by a DEWALT factory service center, a DEWALT authorized service center or other qualified service personnel. Always use identical replacement parts.
Full One Year Warranty
DEWALT heavy duty industrial tools are warranted for one year from date of purchase. We will repair, without charge, any defects due to faulty materials or workmanship. For warranty repair information, call 1-800-4-DEWALT. This warranty does not apply to accessories or damage caused where repairs have been made or attempted by others. This warranty gives you specific legal rights and you may
have other rights which vary in certain states or provinces.
LATIN AMERICA: This warranty does not apply to products sold
in Latin America. For products sold in Latin America, see country specific warranty information contained either in the packaging, call
the local company or see website for warranty information.
FREE WARNING LABEL REPLACEMENT: If your warning labels become illegible or are missing, call 1-800-4-DEWALT for a free
replacement.
17
GLOSSARY
CFM: Cubic feet per minute. SCFM: Standard cubic feet per minute; a unit of measure of air delivery.
PSI: Pounds per square inch; a unit of measure of pressure. kPa (ki[opasca[): Metric pressure measurement. 1 kilopascal equal 1000 pascals.
Code Certification: Products that bear one or more of the following marks: UL, CUL, ETL, CETL, have been evaluated by OSHA certified
independent safety laboratories and meet the applicable Underwriters Laboratories Standards for Safety.
Cut-In Pressure: While the motor is off, air tank pressure drops when accessory is used. When the tank pressure drops to a certain low
level the motor will restart automatically. The low pressure at which the motor automatically restarts is called cut-in pressure.
Cut-Out Pressure: When an air compressor is turned on and begins to run, air pressure in the air tank begins to build. It builds to a
certain high pressure before the motor automatically shuts off, protecting your air tank from pressure higher than its capacity. The
high pressure at which the motor shuts off is called cut-out pressure. Branch Circuit: The circuit carrying electricity from electrical panel to outlet. Duty Cycle: This air compressor pump is capable of running continuously. However, to prolong the life of your air compressor, it is
recommended that a 50%-75% average duty cycle be maintained; that is, the air compressor pump should not run more than 30- 45 minutes in any given hour.
18
Troubleshooting Guide
This section provides a list of the more frequently encountered malfunctions, their causes and corrective actions. The operator or maintenance personnel can perform some corrective actions, and others may require the assistance of a qualified DEWALT technician or your dealer.
Problem Code
Excessive air tank pressure-safety valve pops off ...................................................................... 1,2
Air leaks .................................................................................................................................... 3
Air leaks in air tank or at air tank welds .................................................................................... 4
Air leaks between head and valve plate .................................................................................... 5
Air leaks from safety valve ......................................................................................................... 6
Knocking Noise .......................................................................................................................... 6,16,17
Pressure reading on the regulated pressure gauge drops when an accessory is used ........... 7
Compressor is not supplying enough air to operate accessories .............................................. 8,9,10,11,12,15
Regulator knob has continuous air leak .................................................................................... 13
Regulator will not shut off air outlet ........................................................................................... 13
Moisture in pump crankcase ...................................................................................................... 14,18
Motor will not run ....................................................................................................................... 11,19,20,21,22,23,24,25,26
Troubleshooting Codes
CODE POSSIBLE CAUSE POSSIBLE SOLUTION
Pressure switch does not Shut off moto[ when compressor set the On/Off switch to OFF, if the unit does not ShUt
reaches Cut_out pressure off c0ntact a DEWALT faCt0rY Seiv!Ce center 0r a DEWALT
2 Pressure switch cut-out too high Contact a DEWALT factory service center or a DEWALT
authorized service center.
authorized service center.
19
CODE POSSIBLE CAUSE POSSIBLE SOLUTION
3 Tube fittings are not tight enough Tighten fittings Where air Can be heard eScaPingl cheCk
fittings with soapy water solution. Do Not Overtighten.
4 Defective air tank Air tank must be replaced. Do not repair the leak.
&WARNING: Risk of bursting. Do not drill into, weld or
otherwise modify air tank or it will weaken. The air tank can rupture or explode.
contact a DEWALT factory service cente[ 0r a DEWALT
authorized Service center.
6 Defective safety valve Operate safety valve manually by pulling on ring. If valve
still leaks, it must be replaced.
Regulator is not adjusted coirect!y foi access0iY being, !t is norma! for some pressure drop to occur when an acceS'
used .............................. sory is used, adjust the regulator as instructed in Regulator
under Features if pressure drop s excessive.
, NOTE: Adjust the iegulated pressure undei fl0w cond!tionS
wh e accessory s be ng used.
8 Prolonged excessive use of air Decrease amount of air usage.
compressoi is n0t laige en0ugh f0i acceSSorY Check the accessory air reqUiremenL If it is higher than
the SCFM or pressure Supp!ied by your air Compress0r, a
larger compressor is needed to operate accessory.
10 Hole in air hose Replace air hose. 11 ' Check valve restricted Remove; Clean or replace.
12 Air leaks Tighten fittings.
13 Regulator is damaged Replace:
2O
CODE
14
i5
16
POSSIBLE CAUSE
Unit operating in damp or humid conditions
Restricted air intake filter
Pump oil is low
POSSIBLE SOLUTION Move unit to a dry well ventilated area
clean or repiace air intake filter Add SAE 40, non-detergent air compressor oil to pump. See
Compressor Pump Oil under Maintenance. C0ntact a DEWALT fact0ry Service Center or a DEWALT
authorized service center:
18 Detergent type oil being used in pump
Drain oil and refill pump with SAE 40, non-detergent air
compressor oil.
19 MOtor overload protection switch has tripped
2o Extension cord is wrong length or gauge
see Motor overload UnderFeaturesl Check for proper gauge wire and cord length. See
Extension Cords under Installation.
21 LOOSeelectrical Connections contact a DEWALT factory servce Center or a DEWALT
I aUth0rized service center:
22 Possible defective motor or starting capacitor Contact a DEWALT factory service center or a DEWALT
authorized service center.
23 Pant sprayon nterna mot0r parts cQntact a DEWALT fact0ry service Centei era DEWALT
', authorized service center; Do not operate the c0mpress0r in
the paint spray areal See flammable vapor warning.
21
CODE POSSIBLE CAUSE ............... POSSIBLE SOLUTION
24 Fuse blown, circuit breaker tripped 1. Check fuse box for blown fuse and replace as necessary.
Reset circuit breaker. Do not use afuse or circuit breaker with higher rating than that specified for your particular
branch circuit.
2. Check for proper fuse. Use only a time delay fuse.
3. Check for low voltage conditions and/or proper extension cord.
4. Disconnect the other electrical appliances from circuit or operate the compressor on its own branch circuit.
25 Tank Pressure exceeds pressure switch cut4n pressure Motor will start automatically when tank pressure drops
: below cut-in pressure of pressure switch.
26 Pressure release valve on pressure switch has not Set the On/Off switch to OFR If the valve does not open,
unloaded head pressure replace switch. Contact a DEWALT factory service center or
a DEWALT authorized service center.
22
Loading...
+ 49 hidden pages