NEVER LEAVE THE HEATER UNATTENDED WHILE BURNING!NEVER LEAVE THE HEATER UNATTENDED WHILE BURNING!NEVER LEAVE THE HEATER UNATTENDED WHILE BURNING!
If you have questions or comments, contact us.
Pour toute question ou tout commentaire, nous contacter. Si tiene dudas o comentarious, contéctenos.
a
855-805-5745 • www.DEWALT.com
INSTRUCTION MANUAL
GUIDE DE’UTILISATION
MANUAL DE INSTRUCCIONES
INSTRUCTIVO DE OPERACION, CENTROS DE SERVICIO Y POLIZA
DE GARANTIA, ADVERTENCIA: LEASE ESTE INSTRUCTIVO ANTES
DE USAR EL PRODUCTO.
Electric Forced Air Heater DXH2000 and DXH2003
Chauffage électrique à air forcé DXH2000 and DXH2003
Calentador eléctrico de aire forzado DXH2000 and DXH2003
WARNING: READ INSTRUCTIONS
CAREFULLY: Read and follow all
instructions. Place instructions in a safe
place for future reference. Do not allow
anyone who has not read these instructions
to assemble, adjust or operate the heater.
AVERTISSEMENT:
LES INSTRUCTIONS :
instructions. Conservez ces instructions dans un endroit
sécuritaire pour vous y référer ultérieurement. Interdisez
à quiconque n’ayant pas lu les présentes directives
d’assembler, de régler ou de faire fonctionner cette
fournaise.
VEUILLEZ LIRE ATTENTIVEMENT
Lisez et observez toutes les
41002
ADVERTENCIA:
LAS INSTRUCCIONES: Lea y siga todas las
instrucciones. Conserve estas instrucciones en un
lugar seguro para futura referencia. No permita
que nadie que no haya leído estas instrucciones
arme, ajuste o use el calentador.
LEA CUIDADOSAMENTE
NEVER LEAVE THE HEATER UNATTENDED WHILE BURNING!NEVER LEAVE THE HEATER UNATTENDED WHILE BURNING!NEVER LEAVE THE HEATER UNATTENDED WHILE BURNING!
Definitions: Safety Guidelines
The definitions below describe the level of severity for each signal word. Please read the manual and pay attention to these symbols.
DANGER: Indicates an imminently hazardous situation which, if not avoided, will result in death or serious injury.
WARNING: Indicates a potentially hazardous situation which, if not avoided, could result in death or serious injury.
CAUTION: Indicates a potentially hazardous situation which, if not avoided, may result in minor or moderate injury.
NOTICE: Indicates a practice not related to personal injury which, if not avoided, may result in property damage.
English
WARNING: DO NOT OPERATE THIS HEATER UNTIL YOU READ AND
UNDERSTAND THIS INSTRUCTION MANUAL FOR SAFETY, OPERATION, AND MAINTENANCE INSTRUCTIONS.
CAUTION: Use of this heater in any means not described in this manual
may cause fire, electric shock, personal injury and/or property damage.
CAUTION: This heater is hot when in use. To avoid burns,
do not let bare skin touch hot surfaces. Keep combustible materials, such
as furniture, pillows, bedding, papers, clothes, and curtains at least 6 feet
( 1.8 m) from the front of the heater and keep them at least 2 feet (.6 m)
away from the sides and rear
CAUTION: In order to avoid unintended cycling of the heater, always
unplug or disconnect unit from power source when not in use.
CAUTION: Do not cover the power supply wiring or run the wiring under
any carpet or rugs. Arrange cord and connections away from traffic patterns
so it is not a tripping hazard.
CAUTION: Connect unit to only properly grounded outlets and
adequately sized and grounded electrical systems.
CAUTION: Do not use this unit with unapproved or under sized electrical
connections or wiring. They may overheat and cause a risk of fire.
2
WARNING: Do not use the heater if the unit, plug or cord has
visible damage or the unit has malfunctioned. Contact a reputable
electrician before reusing.
WARNING: Do not expose to wet conditions; unit is intended
for indoor use only.
WARNING: Unit not intended for use in indoor areas where
heater may be exposed to water. Avoid use in bathrooms, laundry
rooms or any other areas where the unit may come in contact with
water.
WARNING: Do not insert or allow any foreign objects to enter
the unit via the intake or exhaust vents on the unit. Failure to
observe this warning may result in electric shock, fire or damage to
the unit.
WARNING: To prevent fire do not block either the air intake or
exhaust.
WARNING: Unit is equipped with internal active electrical
components that spark during use. Do not use in areas where
fumes from gasoline, paint or other flammable liquids may be
present.
WARNING: Extreme caution must be used when any heater is
used by or near children or invalids and whenever the heater is left
operating and unattended.
SAVE THESE INSTRUCTIONS.
NEVER LEAVE THE HEATER UNATTENDED WHILE BURNING!NEVER LEAVE THE HEATER UNATTENDED WHILE BURNING!NEVER LEAVE THE HEATER UNATTENDED WHILE BURNING!
Assembly
• Remove the heater and all of the packaging material from the box.
• Check all of the packing material for loose parts and set aside.
• Remove and retain the four handle mounting screws that are threaded into the
top shell.
• Throughly inspect the heater for damage. If any is found do not contact the place
of purchase. Please call the Manufacturer at 855-805-5745.
• Use the four handle mounting screws to fasten the handle to the top of the heater
Note: Do not over tighten the screws as they can crack the handle.
The handle is located in the carton loose be sure not to throw out.
INSTRUCTIONS FOR ORDERING PARTS ............................ 12
Operational Information
The DeWalt Electric forced air heaters are designed to be used by professionals.
Heat is created by electric current passing through coiled metal elements bringing them up to very high temperatures. The fan then passes room air over the hot elements exchanging cold air for warm.
The air moving over the coils keeps them from reaching temperatures that are not safe for the normal operation of the heater. However it is important to keep all combustible materials and any objects that
may be sucked into the fan blades at a safe distance (please refer to the table on the next page for appropriate distances). Make sure that the fan blades remain unobstructed at all times.
Keep unit clean and dust free. Do not block unit intake or exhaust at any time.
Operation
Review and understand all warnings in this manual. Follow all local codes. These heaters are designed to be used with 240v ac only.
English
This heater must be wired by a certified electrician.
3
NEVER LEAVE THE HEATER UNATTENDED WHILE BURNING!NEVER LEAVE THE HEATER UNATTENDED WHILE BURNING!NEVER LEAVE THE HEATER UNATTENDED WHILE BURNING!
After completely unpacking wheel kit, inspect for damaged or missing pieces.
If there are damaged or missing pieces please contact 1-800-805-5745
-Phillips Head Screw driver
-Socket Wrench w/ 9/16 socket or wrench
Wheel Spacer
Hub Cap
Large Washer
Cotter Pin
Base Plate Bolts
Step 1.
Step 2.
English
Remove bottom panel off heater and
4
2
2
2
2
4
reuse same screws to install the base
plate that is provided in the kit.
Step 3.
Set the heater on top of carriage lining the four threaded bolt
holes with the four holes on the carriage. Attach the heater to
the carriage by using the four bolts provided in hardware kit.
Install the axle and wheels to the carriage.
Step 4.
Attach the handle to the carriage using
the four nuts and bolts provided in the
hardware kit.
FOR ANY QUESTIONS:
Please call Toll Free 1-855-805-5745
Please include the model number, date of purchase and description of problem in all communications.
4
NEVER LEAVE THE HEATER UNATTENDED WHILE BURNING!NEVER LEAVE THE HEATER UNATTENDED WHILE BURNING!NEVER LEAVE THE HEATER UNATTENDED WHILE BURNING!
Starting Instructions, After Heater
Has Been Professionally Wired
1. Place the heater on a stable and level surface. Insure clearance to
combustibles are observed (see table on this page).
2. Turn thermostat counter-clockwise to lowest setting.
3. Move 4 way selector switch from the off position to the fan position for fan only
English
operation.
4. Move the selector switch to the 13kW position for partial power operation. The
partial power input requirement for the DXH2000 is 240Vac/54A which
requires the use of a 60A/2 pole circuit breaker. The partial power input
requirement for the DXH2003 is 240Vac/33A which requires the use of a
40A/3 pole circuit breaker.
5.
Turn thermostat knob up (clockwise) until desired temperature setting is reached.
6. Move the selector switch to the 20kW position for full power operation. The
full power input requirement for the DXH2000 is 240Vac/81A which requires
the use of a 100A/2 pole circuit breaker. The full power requirement for the
DXH2003 is 240Vac/50A which requires a 60A/3 pole circuit breaker.
7. The heating element and fan will remain on until the temperature setting is
reached. The heating element will cycle on and off as needed. The fan will remain
on as long as the control switch is in the on position.
To Stop Heating
Rotate the 4 way selector switch to the fan position for cool down. When the unit is cool move the
selector switch to the off position.
NOTE: This heater is equipped with an overheat limit switch which may cause the
heater to stop.This is indicated by a visual alarm when the power switch is in the
on position and all lights are off. (fig 1) Check and remove the cause of the
overheating before restarting. This can take up to 15 minutes to cool before it
can be restarted.
Maintenance
WARNING:
Never attempt to service the heater while the unit is hot, In use, or plugged in. Only qualified service
technicians should service these units.
• Thoroughly inspect the unit prior to use.
• Keep heater clean and free of dust and debris.
• The use of an air compressor can be used to blow out the dust from the heater case.
use moderate air pressure as to not damage any internal components.
Be sure to only
• A soft dry cloth should be used for cleaning of outer shell and handle.
• The fan motor is sealed and does not need to be lubricated.
Specifications
Model:DXH2000DXH2003
Heat Output BTU/WATTS
Power Cord6/3 AWG for 10’ or less8/4 AWG for 10’ or less
Fan indicator light is on when circulation fan is operating.
5
FIG. 1
NEVER LEAVE THE HEATER UNATTENDED WHILE BURNING!NEVER LEAVE THE HEATER UNATTENDED WHILE BURNING!NEVER LEAVE THE HEATER UNATTENDED WHILE BURNING!
Note: Your heater is equipped with auto cool down and warm-up features.
AUTO COOLDOWN.
When the heater is running and the selector switch is rotated to the off position,
the heater will automatically keep the fan operating until the heater is cool. The
fan will then shut off.
AUTO WARM-UP.
When the heater is stored or started in very cold conditions and a heating mode
is selected, the heating element will turn on to warm up the unit before the fan
will start to blow hot air.
WARNING: USE ONLY MANUFACTURER’S REPLACEMENT PARTS. USE OF ANY OTHER PARTS COULD CAUSE INJURY OR DEATH. REPLACEMENT PARTS ARE ONLY AVAILABLE DIRECT FROM THE FACTORY AND MUST BE INSTALLED BY A QUALIFIED SERVICE AGENCY.
Storage
When not in use, the heater must be disconnected from power source, dusted off and the cord should
be loosely wound around the handle.
For service :
Please call Toll-Free 855-805-5745 www.dewalt.com
Our office hours are 8:00 AM – 5:00 PM, EST, Monday through Friday.
Please include the model number, date of purchase, and description of problem in all communication.
Troubleshooting
Unit does not work • Defective thermostat or wrong thermostat setting
• Open circuit breaker or fuse
• Thermal overload switch has been tripped
• Faulty Connection
• Damaged or defective plug or outlet
Unit runs continuously • Defective thermostat or wrong thermostat setting
• Heat losses higher than unit capacity (unit undersized)
Elements are on but motor does not rotate • Defective Motor
• Blocked fan blades
Enclosure is extremely hot • Defective thermal protection
• Blocked air vents
• Defective motor
Desired room temperature cannot be reached • One or more elements are defective
• Defective thermostat or wrong thermostat setting
• Voltage lower than that written on Rate tag
• Heat losses higher than unit capacity (unit undersized)
Overheating • Defective thermostat or wrong thermostat setting
• Defective Motor
Heater emits a humming sound • Defective motor
• Fan blade blocked
6
English
English
NEVER LEAVE THE HEATER UNATTENDED WHILE BURNING!NEVER LEAVE THE HEATER UNATTENDED WHILE BURNING!NEVER LEAVE THE HEATER UNATTENDED WHILE BURNING!
Wiring Diagrams
DXH2000
DXH2003
7
Parts List DXH2000
NEVER LEAVE THE HEATER UNATTENDED WHILE BURNING!NEVER LEAVE THE HEATER UNATTENDED WHILE BURNING!NEVER LEAVE THE HEATER UNATTENDED WHILE BURNING!
Use only manufacturer’s replacement parts. Use of any other parts could cause injury or death.
Replacement parts are only available direct from the factory and must be installed by a qualified
service agency.
Please call Toll-Free 855-805-5745 www.dewalt.com
Our office hours are 8:00 AM – 5:00 PM, EST, Monday through Friday.
Please include the model number, date of purchase, and description of problem in all communication.
English
8
DXH2000
English
NEVER LEAVE THE HEATER UNATTENDED WHILE BURNING!NEVER LEAVE THE HEATER UNATTENDED WHILE BURNING!NEVER LEAVE THE HEATER UNATTENDED WHILE BURNING!
9
NEVER LEAVE THE HEATER UNATTENDED WHILE BURNING!NEVER LEAVE THE HEATER UNATTENDED WHILE BURNING!NEVER LEAVE THE HEATER UNATTENDED WHILE BURNING!
Use only manufacturer’s replacement parts. Use of any other parts could cause injury or death.
Replacement parts are only available direct from the factory and must be installed by a qualified
service agency.
For Service
Please call Toll-Free 855-805-5745 www.dewalt.com
Our office hours are 8:00 AM – 5:00 PM, EST, Monday through Friday.
Please include the model number, date of purchase, and description of problem in all communication.
10
DXH2003
English
NEVER LEAVE THE HEATER UNATTENDED WHILE BURNING!NEVER LEAVE THE HEATER UNATTENDED WHILE BURNING!NEVER LEAVE THE HEATER UNATTENDED WHILE BURNING!
11
Loading...
+ 25 hidden pages
You need points to download manuals.
1 point = 1 manual.
You can buy points or you can get point for every manual you upload.