INSTRUCTION MANUAL
GUIDE DE’UTILISATION
MANUAL DE INSTRUCCIONES
Electric Forced Air Heater DXH165
Chauffage électrique à air forcé DXH165
Calentador eléctrico de aire forzado DXH165
READ INSTRUCTIONS CAREFULLY: Read
and follow all instructions. Place instructions
in a safe place for future reference. Do
not allow anyone who has not read these
instructions to assemble, adjust or operate
the heater.
VEUILLEZ LIRE ATTENTIVEMENT LES INSTRUCTIONS :
Lisez et observez toutes les instructions. Conservez
ces instructions dans un endroit sécuritaire pour vous
y référer ultérieurement. Interdisez à quiconque n’ayant
pas lu les présentes directives d’assembler, de régler ou
de faire fonctionner cette fournaise.
INSTRUCTIVO DE OPERACION, CENTROS DE SERVICIO Y POLIZA
DE GARANTIA, ADVERTENCIA: LEASE ESTE INSTRUCTIVO ANTES
DE USAR EL PRODUCTO.
7/13 41000 Rev13A
LEA CUIDADOSAMENTE LAS INSTRUCCIONES:
Lea y siga todas las instrucciones. Conserve
estas instrucciones en un lugar seguro para futura
referencia. No permita que nadie que no haya
leído estas instrucciones arme, ajuste o use el
calentador.
Definitions: Safety Guidelines
The denitions below describe the level of severity for each signal word. Please read the manual and pay attention to these symbols.
DANGER: Indicates an imminently hazardous situation which, if not avoided, will result in death or serious injury.WARNING: Indicates a potentially hazardous situation which, if not avoided, could result in death or serious injury.CAUTION: Indicates a potentially hazardous situation which, if not avoided, may result in minor or moderate injury.NOTICE: Indicates a practice not related to personal injury which, if not avoided, may result in property damage.
English
WARNING: DO NOT OPERATE THIS HEATER UNTIL YOU READ
AND UNDERSTAND THIS INSTRUCTION MANUAL FOR SAFETY,
OPERATION, AND MAINTENANCE INSTRUCTIONS.
CAUTION: Use of this heater in any means not described in this manual
may cause re, electric shock, personal injury and/or property damage.
CAUTION: This heater is hot when in use. To avoid burns,
do not let bare skin touch hot surfaces. Keep combustible materials, such
as furniture, pillows, bedding, papers, clothes, and curtains at least 6 feet
( 1.8 m) from the front of the heater and keep them at least 2 feet (.6 m)
away from the sides and rear
CAUTION: In order to avoid unintended cycling of the heater, always
unplug or disconnect unit from power source when not in use.
CAUTION: Do not cover the power supply wiring or run the wiring under
any carpet or rugs. Arrange cord and connections away from trafc patterns
so it is not a tripping hazard.
CAUTION: Connect unit to only properly grounded outlets and
adequately sized and grounded electrical systems.
CAUTION: Do not use this unit with unapproved or under sized electrical
connections or wiring. They may overheat and cause a risk of re.
WARNING: Do not use the heater if the unit, plug or cord has
visible damage or the unit has malfunctioned. Contact a reputable
electrician before reusing.
WARNING: Do not expose to wet conditions; unit is intended
for indoor use only.
WARNING: Unit not intended for use in indoor areas where
heater may be exposed to water. Avoid use in bathrooms, laundry
rooms or any other areas where the unit may come in contact with
water.
WARNING: Do not insert or allow any foreign objects to enter
the unit via the intake or exhaust vents on the unit. Failure to
observe this warning may result in electric shock, re or damage to
the unit.
WARNING: To prevent re do not block either the air intake or
exhaust.
WARNING: Unit is equipped with internal active electrical
components that spark during use. Do not use in areas where
fumes from gasoline, paint or other ammable liquids may be
present.
WARNING: Extreme caution must be used when any heater is
used by or near children or invalids and whenever the heater is left
operating and unattended.
SAVE THESE INSTRUCTIONS.
2
Assembly
• Remove the heater and all of the packaging material from the box.
• Check all of the packing material for loose parts and set aside.
• Locate the hardware package containing four screws and the handle.
• Throughly inspect the heater for damage. If any is found do not contact the place
of purchase. Please call the Manufacturer at 855-805-5745.
• Use the screws the fasten the handle to the top of the unit. Note: Do not over
tighten the screws as they can crack the handle.
Handle and Hardware pack are located in the carton loose, be sure not to throw out.
The DeWalt Electric forced air heaters are designed to be used by professionals.
Heat is created by electric current passing through coiled metal elements bringing them up to very high temperatures. The fan then passes room air over the hot elements
exchanging cold air for warm.
The air moving over the coils keeps them from reaching temperatures that are not safe for the normal operation of the heater. However it is important to keep all combustible
materials and any objects that may be sucked into the fan blades at a safe distance (please refer to the table on the next page for appropriate distances). Make sure that the fan
blades remain unobstructed at all times.
Keep unit clean and dust free. Do not block unit intake or exhaust at any time.
INSTRUCTIONS FOR ORDERING PARTS ............................ 9
Operation
Review and understand all warnings in this manual. Follow all local codes.
This unit is designed to be used with 115v ac only.
This unit is supplied with the appropriate (NEMA 5-15P) plug. Do not use any plug other than the one supplied by the manufacturer.
If damage has occurred please refer to the parts listing in this manual and contact the manufacturer for a replacement.
This unit is designed to be used with a properly grounded NEMA 5-15 outlet only (show on the right).
English
WARNING: Outlet must be properly grounded, failure to do so may result in electric shock.
3
Starting Instructions
1. Place the heater on a stable and level surface. Insure clearance to
combustibles are observed (see table on this page).
2. Turn thermostat counter-clockwise to lowest setting.
3. Plug the heater into a properly grounded outlet.
4. Depress the power switch into the on “I” position.
5. Turn thermostat knob up (clockwise) until desired temperature is reached.
English
6. The Heating element and fan will remain on until the temperature
setting is reached. The unit will cycle on and off as needed.
To Stop Heating
1. Rotate the thermostat knob to the lowest position.
2. Flip the power switch into the “off” position.
3. Disconnect plug from power supply.
NOTE: This heater is equipped with an overheat limit switch which may cause the
heater to stop. This is indicated by a visual alarm when the power switch is in the
on position and the “fault” light comes on. (g 1) Check and remove the cause of
the overheating before restarting. This can take up to 15 minuets to cool before it
can be restarted.
Maintenance
WARNING:
Never attempt to service the heater while the unit is hot, In use, or plugged in.
Only qualified service technicians should service these units.
• Throughly inspect the unit prior to use.
• Keep heater clean and free of dust and debris.
• The use of an air compressor can be used to blow out the case. Be sure to only
use moderate air pressure as to not damage any internal components.
• A soft dry cloth should be used for cleaning of outer shell and handle.
• The fan motor is sealed and does not need to be lubricated.
Specifications
Model:DXH165
Heat Output BTU/WATTS5630/1650
Airflow (CFM)120
Electrical Supply115V 13.5 60Hz
Power Cord (supplied)3-14awg
Plug (supplied)
NEMA 5-15p
Min. Extension Cord3-12awg
Thermostat
23°F - 95°F
Dimensions: (L”xW”xH”)13”x9”x11”
Weight (lbs.)14 lb.
Clearance to Combustibles
Outlet (Feet)6 (1.8m)
Rear (Feet)2 (.6m)
Tom (Feet)2 (.6m)
BottomNon-combustible floor
ON/OFF FAULT/LED THERMOSTAT
4
FIG. 1
Storage
When not in use, the heater must be disconnected from power source, dusted off
and the cord should be loosely wound around the handle.
For service :
Please call Toll-Free 855-805-5745 www.dewalt.com
Our office hours are 8:30 AM – 5:00 PM, EST, Monday through Friday.
Please include the model number, date of purchase, and description of problem in all
communication.
WARNING: USE ONLY MANUFACTURER’S REPLACEMENT
PARTS. USE OF ANY OTHER PARTS COULD CAUSE INJURY
OR DEATH. REPLACEMENT PARTS ARE ONLY AVAILABLE
DIRECT FROM THE FACTORY AND MUST BE INSTALLED BY
A QUALIFIED SERVICE AGENCY.
Troubleshooting
Unit does not work • Defective thermostat or wrong thermostat setting
• Open circuit breaker or fuse
• Thermal overload switch has been tripped
• Faulty Connection
• Damaged or defective plug or outlet
Unit runs continuously • Defective thermostat or wrong thermostat setting
• Heat losses higher than unit capacity (unit undersized)
Elements are on but motor does not rotate • Defective Motor
• Thermal overload switch has been tripped
• Blocked fan blades
Enclosure is extremely hot • Defective thermal protection
• Blocked air vents
• Defective motor
Desired room temperature cannot be reached • One or more elements are defective
• Defective thermostat or wrong thermostat setting
• Voltage lower than that written on Rate tag
• Heat losses higher than unit capacity (unit undersized)
Overheating • Defective thermostat or wrong thermostat setting
• Defective Motor
Heater emits a humming sound • Defective motor
• Fan blade blocked
English
5
English
Wiring Diagram
6
DXH165
English
7
Parts List DXH165
R E F. # ..............ITEM#............ DESCRIPTION
14 .................... 41024 ............. M OTOR, FAN
WARNING:
Use only manufacturer’s replacement parts. Use of any other parts could cause injury
or death. Replacement parts are only available direct from the factory and must be
installed by a qualified service agency.
R E F. # ..............ITEM#............ DESCRIPTION
* ......................410 97 ............. Power Cord
*Not shown on drawing.
BOARD, CIRCUIT, HIGH LIMIT, INDICATOR
THERMOSTAT, TEMPERATURE, AMBIANT
For Service
Please call Toll-Free 855-805-5745 www.dewalt.com
Our office hours are 8:30 AM – 5:00 PM, EST, Monday through Friday.
Please include the model number, date of purchase, and description of problem in
all communication.
8
INSTRUCTION MANUAL
Electric Forced-Air Heater DXH165
Model Starting Serial Number
DXH165 LN-340635-13001001
Warning:
Use only manufacturer’s replacement parts. Use of any other parts could cause
injury or death. Replacement parts are only available direct from the factory and
must be installed by a qualified service agency.
PARTS ORDERING INFORMATION:
PURCHASING: Accessories may be purchased at any DeWalt® local
dealer or direct from the factory
FOR INFORMATION REGARDING SERVICE:
Please call Toll-Free 855-805-5745
www.dewalt.com
Our office hours are 8:30 AM – 5:00 PM, EST, Monday through Friday.
Please include the model number, date of purchase, and description of
problem in all communication.
LIMITED WARRANTY:
DeWalt® warrants its heaters and accessories to be free from defects in
material and workmanship for a period of 1 year from date of purchase.
DeWalt® will repair or replace this product free of charge if it has been
proven to be defective within the 1-year period, and is returned at customer
expense with proof of purchase to DeWalt® within the warranty period.