DeVillbiss SP-100-E, WB100D-2, MGP-XE-WB-C1D User Manual

OWNERS MANUAL FOR
PERMANENTLY LUBRICATED
AIR COMPRESSOR
MODEL NOS.
WB100D-2 — XE-7D-2 — IRC1D-2
(For Home Use Only)
SPECIFICATION CHART
Model No.
Horsepower SCFM @ 40 psig SCFM @ 90 psig Bore Stroke Voltage-Single Phase Minimum Branch Circuit Requirement *Fuse Type
*A circuit breaker is preferred. Use only a fuse or circuit breaker that is the same rating as the branch circuit the air compressor is operated on. If the air compressor is connected to a circuit protected by fuses, use quick acting fuses.
SAFETY GUIDELINES - DEFINITIONS
This manual contains information that is important for you to know and understand. This information relates to protecting YOUR
SAFETY and PREVENTING EQUIPMENT PROBLEMS. To
help you recognize this informa­tion, we use symbols to the right. Please read the manual and pay attention to these sections.
WB100D-2
3/4
3.0
2.2 1 3/4" 1 1/4"
120
15 AMPS
Quick Acting
URGENT SAFETY INFORMATION - A HAZ­ARD THAT WILL CAUSE SERIOUS INJURY OR LOSS OF LIFE.
IMPORTANT SAFETY INFORMATION - A HAZARD THAT MIGHT CAUSE SERIOUS INJURY OR LOSS OF LIFE.
XE-7D-2
3/4
3.0
2.2 1 3/4" 1 1/4"
120
15 AMPS
Quick Acting
Information for preventing damage to equipment.
Information that you should pay special attention to.
IRC1D-2
----
3.0
2.2 1 3/4" 1 1/4"
120
15 AMPS
Quick Acting
MGP-XE-WB-C1D 11/5/97
213 Industrial Dr. • Jackson, TN 38301-9615
TABLE OF CONTENTS
Page
SAFETY GUIDELINES . Cover Page
WARRANTY STATEMENT ..................................... 3
WARNING CHART ............................................... 4-5
GLOSSARY ......................................................... 5
DUTY CYCLE ...................................................... 5
DESCRIPTION OF OPERATION ........................... 6
INSTALLATION AND BREAK-IN
PROCEDURES ................................................. 6-7
Location of Air Compressor ........................ 6
Page
Extension Cords ......................................... 6
Grounding Instructions ................................ 6-7
Air Hose ...................................................... 7
OPERATING PROCEDURES ............................... 7
STORAGE ........................................................... 8
AIR COMPRESSOR
DIAGRAM ............................................................ 9
TROUBLESHOOTING GUIDE .............................. 10
HOW TO ORDER REPAIR PARTS .......... Back Cover
2 — ENG
LIMITED WARRANTY
ONE YEAR FROM DATE OF PURCHASE
All merchandise manufactured by DeVilbiss Air Power Company is warranted to be free of defects in workmanship and material which occur during the first year from the date of purchase by the original purchaser (initial user). Products covered under this warranty include: air compressors, *air tools, accessories, service parts, pressure washers, and generators used in consumer applications (i.e., personal residential household usage only).
Air compressors, *air tools, accessories, service parts, pressure washers, and generators used in commercial applications (income producing) are covered by a 90 day warranty.
DeVilbiss Air Power will repair or replace, at DeVilbiss's option, products or components which have failed within the warranty period. Repair or replacement, and service calls on 60 and 80 gallon air compressors, will be handled by Authorized Warranty Service Centers and will be scheduled and serviced according to the normal work flow and business hours at the service center location, and depending on the availability of replacement parts.
All decisions of DeVilbiss Air Power Company with regard to this policy shall be final.
This warranty gives you specific legal rights, and you may also have other rights which vary from state to state.
RESPONSIBILITY OF ORIGINAL PURCHASER (Initial User):
Retain original cash register sales receipt as proof of purchase for warranty work.Use reasonable care in the operation and maintenance of the product as described in the Owners Manual(s).Deliver or ship the product to the nearest DeVilbiss Air Power Authorized Warranty Service Center.
Freight costs, if any, must be paid by the purchaser.
Air compressors with 60 and 80 gallon tanks only will be inspected at the site of installation. Contact the nearest
Authorized Warranty Service Center, that provides on-site service calls, for service call arrangement.
If the purchaser does not receive satisfactory results from the Authorized Warranty Service Center, the purchaser
should contact DeVilbiss Air Power Company.
THIS WARRANTY DOES NOT COVER:
Merchandise sold as reconditioned, floor models and/or display models. Any damaged or incomplete equipment
sold "as is".
Merchandise used as "rental" equipment.Merchandise that has become inoperative because of ordinary wear, misuse, freeze damage, use of improper
chemicals, negligence, accident, improper and/or unauthorized repair or alterations including failure to operate the product in accordance with the instructions provided in the Owners Manual (s) supplied with the product. *Air Tools: O-Rings and driver blades are considered ordinary wear parts, therefore, they are warranted for a period of 45 days from the date of purchase.
An air compressor that pumps air more than 50% during a one hour period is considered misuse because
the air compressor is undersized for the required air demand. Maximum compressor pumping time per hour is 30 minutes.
Merchandise sold by DeVilbiss Air Power which has been manufactured by and identified as the product of
another company. The product manufacturer's warranty will apply.
Repair and transportation costs of merchandise determined not to be defective.Cost associated with assembly, required oil, adjustments or other installation and start-up cost.ANY INCIDENTAL, INDIRECT OR CONSEQUENTIAL LOSS, DAMAGE, OR EXPENSE THAT MAY RESULT FROM
ANY DEFECT, FAILURE OR MALFUNCTION OF THE PRODUCT. Some states do not allow the exclusion or limitation of incidental or consequential damages, so the above limitation or exclusion may not apply to you.
IMPLIED WARRANTIES, INCLUDING THOSE OF MERCHANTABILITY AND FITNESS FOR A PARTICULAR
PURPOSE, ARE LIMITED TO ONE YEAR FROM THE DATE OF ORIGINAL PURCHASE. Some states do not allow limitations on how long an implied warranty lasts, so the above limitations may not apply to you.
DeVilbiss Air Power Company
213 Industrial Drive • Jackson, TN 38301-9615 • Telephone: 1-800-888-2468 , Ext. 2 • FAX: 1-800-888-9036
Form: SP-100-E - 4/25/96
3 — ENG
IMPORTANT SAFETY INSTRUCTIONS
• SAVE THESE INSTRUCTIONS •
IMPROPER OPERATION OR MAINTENANCE OF THIS PRODUCT COULD RESULT IN SERIOUS INJURY AND PROPERTY DAMAGE. READ AND UNDERSTAND ALL WARNINGS AND OPERATING INSTRUCTIONS BEFORE USING THIS EQUIPMENT.
HAZARD
RISK OF BURSTING
RISK OF
EXPLOSION OR FIRE
WHAT CAN HAPPEN
ATTACHMENTS & ACCESSORIES
EXCEEDING THE PRESSURE RATING OF AIR TOOLS, SPRAY GUNS, AIR OPERATED
ACCESSORIES, TIRES AND OTHER INFLATABLES PLODE OR FLY APART, AND COULD RESULT IN SERIOUS INJURY.
USE OF UNAUTHORIZED REPLACEMENT
AIR HOSE COULD PRODUCE EXCESSIVE SYSTEM PRESSURE AND CAUSE DAMAGES TO THE COMPRESSOR AND HOSE FAILURE WHICH COULD RESULT IN SERIOUS INJURY.
IT IS NORMAL FOR ELECTRICAL CONTACTS WITHIN THE MOTOR AND PRES- SURE SWITCH TO SPARK.
IF ELECTRICAL SPARKS FROM COMPRES- SOR COME INTO CONTACT WITH FLAMMABLE VAPORS, THEY MAY IGNITE, CAUSING FIRE OR EXPLOSION.
CAN CAUSE THEM TO EX-
HOW TO PREVENT IT
FOLLOW THE EQUIPMENT MANUFACTUR­ERS RECOMMENDATION AND NEVER EX­CEED THE MAXIMUM ALLOWABLE PRES­SURE RATING OF ATTACHMENTS.
USE COMPRESSOR TO INFLATE SMALL LOW-PRESSURE OBJECTS SUCH AS CHILDREN’S TOYS, FOOTBALLS, BASKETBALLS. ETC.
HOSE IS PERMANENTLY ATTACHED TO THE COMPRESSOR AND SHOULD ONLY BE REPLACED BY AUTHORIZED SERVICE CENTER PERSONNEL USING CERTIFIED REPLACEMENT PARTS.
ALWAYS OPERATE THE COMPRESSOR IN A WELL VENTILATED AREA FREE OF COMBUSTIBLE MATERIALS, GASOLINE OR SOLVENT VAPORS.
IF SPRAYING FLAMMABLE MATERIALS,
LOCATE COMPRESSOR AT LEAST 20 FEET AWAY FROM SPRAY AREA. AN
ADDITIONAL LENGTH OF HOSE MAY BE REQUIRED.
STORE FLAMMABLE MATERIALS IN A SECURE LOCATION AWAY FROM COMPRESSOR.
NEVER
RISK OF
ELECTRICAL SHOCK
RESTRICTING ANY OF THE COMPRESSOR VENTILATION OPENINGS WILL CAUSE SERI­OUS OVERHEATING AND COULD CAUSE FIRE.
UNATTENDED OPERATION OF THIS PROD­UCT COULD RESULT IN PERSONAL INJURY OR PROPERTY DAMAGE.
YOUR AIR COMPRESSOR IS POWERED BY ELECTRICITY. LIKE ANY OTHER ELECTRI- CALLY POWERED DEVICE, IF IT IS NOT USED PROPERLY IT MAY CAUSE ELECTRIC SHOCK.
REPAIRS ATTEMPTED BY UNQUALIFIED PERSONNEL CAN RESULT IN SERIOUS INJURY OR DEATH BY ELECTROCUTION.
ELECTRICAL GROUNDING: FAILURE TO PROVIDE ADEQUATE GROUNDING TO THIS PRODUCT COULD RESULT IN SERIOUS INJURY OR DEATH FROM ELECTROCU­TION. SEE GROUNDING INSTRUCTIONS.
NEVER PLACE OBJECTS AGAINST OR ON TOP OF COMPRESSOR. OPERATE COM­PRESSOR IN AN OPEN AREA AT LEAST 12 INCHES AWAY FROM ANY WALL OR OBSTRUCTION THAT WOULD RESTRICT
THE FLOW OF FRESH AIR TO THE VENTILATION OPENINGS.
ALWAYS REMAIN IN ATTENDANCE WITH
THE PRODUCT WHEN IT IS OPERATING. UNPLUG COMPRESSOR WHENEVER IS NOT BEING USED.
NEVER OPERATE THE COMPRESSOR OUT­DOORS WHEN IT IS RAINING OR IN WET CONDITIONS.
ANY ELECTRICAL WIRING OR REPAIRS REQUIRE ON THIS PRODUCT SHOULD BE
PERFORMED BY AUTHORIZED SERVICE CENTER PERSONNEL IN ACCORDANCE
WITH NATIONAL AND LOCAL ELECTRICAL CODES.
MAKE CERTAIN THAT THE ELECTRICAL CIRCUIT TO WHICH THE COMPRESSOR IS CONNECTED PROVIDES PROPER ELEC­TRICAL GROUNDING, CORRECT VOLT­AGE AND ADEQUATE FUSE PROTEC­TION.
CONTINUE NEXT PAGE
*
4 — ENG
Loading...
+ 8 hidden pages