Desa Tech TC100RNG Owner's Manual

NATURAL GAS
CONSTRUCTION
HEATER
OWNER’S MANUAL
®
Model: TC100RNG
IMPORTANT: Read and understand this manual before assembling, starting, or servicing heater. Improper use of heater can cause serious injury. Keep this manual for future reference.
FAILURE TO COMPLY WITH THE PRECAUTIONS AND INSTRUCTIONS PROVIDED WITH THIS HEATER, CAN RESULT IN DEATH, SERIOUS BODILY INJURY AND PROPERTY LOSS OR DAMAGE FROM HAZARDS OF FIRE, EXPLOSION, BURN, ASPHYXIATION, CARBON MONOXIDE POISONING AND/OR ELECTRICAL SHOCK.
ONLY PERSONS WHO CAN UNDERSTAND AND FOLLOW THE INSTRUCTIONS SHOULD USE OR SERVICE THIS HEATER.
IF YOU NEED ASSISTANCE OR HEATER INFORMATION SUCH AS AN INSTRUCTIONS MANUAL, LABELS, ETC. CONTACT THE MANUFACTURER.
TC100RNG NATURAL GAS CONSTRUCTION HEATER
SAFETY INFORMATION
WARNINGS
WARNING ICON G 001
WARNING: FIRE, BURN, IN­HALATION, AND EXPLOSION HAZARD. KEEP SOLID COMBUS­TIBLES, SUCH AS BUILDING MA­TERIALS, PAPER OR CARD­BOARD, A SAFE DISTANCE AWAY FROM THE HEATER AS RECOMMENDED BY THE IN­STRUCTIONS. NEVER USE THE HEATER IN SPACES WHICH DO OR MAY CONTAIN VOLATILE OR AIRBORNE COMBUSTIBLES, OR PRODUCTS SUCH AS GASO­LINE, SOLVENTS, PAINT THIN­NER, DUST PARTICLES OR UN­KNOWN CHEMICALS.
WARNING: NOT FOR HOME OR RECREATIONAL VEHICLE USE.
The heater is designed for use as a construc­tion heater in accordance with ANSI Z83.7/ CGA 2.14. Other standards govern the use of fuel gases and heating products for spe­cific uses. Your local authority can advise you about these. The primary purpose of construction heaters is to provide temporary heating of buildings under construction, al­teration or repair. Properly used, the heater provides safe economical heating. Products of combustion are vented into the area being heated.
We cannot foresee every use which may be made of our heaters. CHECK WITH
YOUR LOCAL FIRE SAFETY AU­THORITY IF YOU HAVE QUESTIONS ABOUT HEATER USE.
Other standards govern the use of fuel gases and heat producing products for specific uses. Your local authorities can advise you about these.
Carbon Monoxide Poisoning: Some people are more affected by carbon monox­ide than others. Early signs of carbon mon­oxide poisoning resemble the flu, with head­aches, dizziness, and/or nausea. If you have these signs, the heater may not be working properly. Get fresh air at once! Check for proper ventilation and have heater serviced.
Natural Gas: Natural gas has a distinctive odor. This odor helps you detect a natural gas leak. However, the odor may fade. Natu­ral gas may be present even though no odor exists.
Make certain you read and understand all Warnings. Keep this manual for reference. It is your guide to safe and proper operation of this heater.
Install and use heater with care. Fol­low all local ordinances and codes. In the absence of local ordinances and codes, refer to the National Fuel Gas
Code Handbook, NFP A54/ANSI Z223.1 and the Natural Gas Installation Code, CAN/CGA B149.2. This instructs on the
safe storage and handling of flammable gases.
Use only with natural gas. Do not at­tempt to use with LP gas.
Provide adequate ventilation. Before using heater, provide at least a three­square-foot opening of fresh, outside air for each 100,000 Btu/Hr of rating. This heater produces carbon monoxide, which is listed by the State of Califor­nia as a reproductive toxin under Propo­sition 65.
For indoor use only. Do not use heater outdoors.
Do not use heater in occupied dwell­ings or in living or sleeping quarters.
Do not use heater below ground level.
Keep appliance area clear and free from combustible materials, gasoline, paint thinner, and other flammable vapors and liquids. Do not use heater in areas with high dust content.
Minimum heater clearances from combustible materials:
Sides: 6 Ft. Top: 5 Ft.
Check heater for damage before each use. Do not use a damaged heater.
Check hose (if used) before each use of heater. If highly worn or cut, replace before using heater.
Locate heater on stable and level sur­face if heater is hot or operating.
Not intended for use on finished floors.
Never block air inlet (bottom of shell) or air outlet (top of shell) of heater.
Keep heater away from strong drafts,
water spray, rain, or dripping water.
Keep children and animals away from heater.
Do not leave heater unattended.
Never move, handle, or service a hot or operating heater. Severe burns may result. You must wait 20 minutes after turning heater off.
To prevent injury, wear gloves when handling heater.
Never attach duct work to heater.
Do not alter heater. Keep heater in its original state.
Do not use heater if altered.
Turn off natural gas supply to heater when not in use.
Use only original replacement parts. This heater must use design-specific parts. Do not substitute or use generic parts. Improper replacement parts could cause serious or fatal injuries.
UNPACKING
1. Remove all packing items applied to heater for shipment. Keep plastic cover caps (attached to valve inlet) for storage.
2. Remove all items from carton.
3. Check all items for shipping damage. If heater is damaged, promptly inform dealer where you bought heater.
4. Hose not included. User must supply hose or flexible connector.
THEORY OF OPERATION
The Fuel System: The gas supply at­taches to the heater by a minimum 3/4 inch i.d. hose or flexible connector. User must supply hose or flexible connector. The length should be no more than 10 feet long. The natural gas moves through the regulator and out the nozzle.
The Ignition System: The piezo ignitor lights the pilot fuel supply.
The Automatic Control System: The automatic control valve shuts off the heater if the flame goes out.
2
104131
OWNER’S MANUAL
PRODUCT IDENTIFICATION
Shell
Nozzle
Main Burner Tube
Automatic Control Valve Button
Figure 1 - Product Identification
NATURAL GAS SUPPLY
The user must furnish the natural gas supply and the connections to the heater.
Regulate the natural gas supply down from a minimum 6 inches water column to a maximum of 1/2 psi. The natural gas supply capacity should be able to supply a mini­mum of 100 cubic feet of gas at pressure for each heater connected to the system.
Consult your natural gas supplier for proper sizing of the natural gas supply lines.
Follow all local ordinances and codes. In the absence of local ordinances and codes, refer to the National Fuel Gas Code Handbook,
NFPA54/ANSI Z223.1 and the Natural gas Installation Code, CAN/CGA B149.2.
Top
Emitter
Ignitor Electode
Pilot Burner
Thermocouple
Regulator
Piezo Ignitor Button
Valve Inlet
Base
VENTILATION
WARNING: Provide at least a 3 square foot opening of fresh, outside air while running heater. If proper fresh, outside air venti­lation is not provided, carbon monoxide poisoning can occur. Provide proper fresh, outside air ventilation before running heater.
FRESH OUTSIDE AIR OPENING REQUIREMENTS
HEATER SQUARE FOOT
SIZE OPENING
100,000 Btu/Hr 3.0
SPECIFICATIONS
Rating (Btu/Hr) 100,000 Fuel Natural Gas Only Fuel Consumption
Cubic Feet/Hour 97
Supply Pressure (To Regulator)
Maximum 1/2 psi
Minimum 6" w.c. Manifold Pressure 4" w.c. Weight (Pounds) 23 Shipping Weight (Pounds) 27 Size - L x W x H (Inches) 16 x 16 x 29.5
INSTALLATION
WARNING: Review and un­derstand the warnings in the Safety Information Section, page
2. They are needed to safely op­erate this heater. Follow all local codes when using this heater.
WARNING: Test all gas pip­ing and connections for leaks after installation or servicing. Never use an open flame to check for a leak. Apply a mixture of liquid soap and water to all joints. Bubbles forming show a leak. Correct all leaks at once.
1. Provide natural gas supply system.
2. Install plumbing to a low pressure natu­ral gas source. The source must be regu­lated to 1/2 psi maximum. The plumb­ing must be a minimum 3/4 inch i.d. hose or flexible connector not over 10 feet long.
Valve Inlet
Hose
Figure 2 - Hose and Valve Inlet
Continued
104131
3
TC100RNG NATURAL GAS CONSTRUCTION HEATER
INSTALLATION
Continued
3. Connect the hose to the heater at the 1/2 inch SAE flare fitting at the valve inlet.
WARNING: Never use an open flame to check for a leak. Apply a mixture of liquid soap and water to all joints. Bubbles forming show a leak that must be cor­rected. Correct all leaks at once.
Tighten all fittings with a wrench
4. Open natural gas supply valve slowly.
5. Check all connections for leaks.
6. Close natural gas supply valve.
OPERATION
WARNING: Review and un­derstand the warnings in the Safety Information Section. They are needed to safely operate this heater. Follow all local codes when using this heater.
5. Push in and hold control valve knob while pushing red piezo ignitor button. Ignitor button may have to be pushed again (3 to 8 times) until pilot lights.
Note:
Hose may be filled with air. If so, allow 20 seconds for gas to reach pilot before pushing ignitor button.
6. After pilot lights, keep control valve knob depressed for at least 30 seconds, then release.
7. If pilot light goes out, repeat steps 4 through 6.
8. When pilot remains lit, start heater by slowly turning control valve knob 1/4 turn to left to ON position (see Figure 4).
PILOT
OFF
ON
FROM “PILOT” POSITION
Figure 4 - ON Position
TURN OFF
SLIGHT PUSH TO
OFFON
LIGHT
FULL PUSH TO
TO STOP HEATER
1. Close valve on gas supply.
2. Turn control valve knob 1/4 turn to right to PILOT position. Slightly push in knob and turn 1/4 turn to right to OFF position (see Figure 6).
PILOT
FROM “PILOT” POSITION
ON
SLIGHT PUSH TO
FULL PUSH TO
TURN OFF
LIGHT
Figure 6 - OFF Position
OFF
OFFON
TO RESTART HEATER
1. W ait five minutes after stopping heater .
2. Restart heater by following steps un­der “To Start Heater.”
STORAGE
CAUTION: Disconnect heater
from natural gas supply.
TO START HEATER
1. Follow all installation, ventilation, and safety information.
2. Locate heater on stable and level sur­face. Make sure strong drafts do not blow on heater.
3. Open gas supply slowly.
4. Turn control valve knob 1/4 turn to left to PILOT position (see Figure 3).
PILOT
ON
OFF
FROM “PILOT” POSITION
SLIGHT PUSH TO
TURN OFF
FULL PUSH TO
LIGHT
Figure 3 - PILOT Position
OFFON
Control Valve Knob
Figure 5 - Control Valve Knob and Piezo Ignitor Button Locations
Piezo Ignitor Button
1. Place plastic cover cap over brass fit­ting on inlet connector.
2. Store in dry, clean, and safe place.
3. When taking heater out of storage, al­ways check inside of heater. Insects and small animals may place foreign objects in heater. Keep inside of heater free from combustible and foreign objects.
4
104131
Loading...