Desa Tech K-50, K100-FA, K100-FAT, K150-FA, K150-FAT Owner's Manual

...
FORCED AIR OIL CONSTRUCTION HEATERS
INSTRUCTIONS AND PARTS LIST
MODELS
50,000 BTU/HR 100,000 BTU/HR 150,000 BTU/HR K50-FA K100-FA K150-FA SPC-K50 SPC-K100 SPC-K150
!
YOUR SAFETY IS IMPORTANT TO YOU AND TO OTHERS, SO PLEASE READ THESE INSTRUCTIONS BEFORE YOU OPERATE THIS HEATER.
GENERAL HAZARD WARNING:
!
FAILURE TO COMPLY WITH THE PRECAUTIONS AND INSTRUCTIONS PROVIDED WITH THIS HEATER, CAN RESULT IN DEATH, SERIOUS BODILY INJURY AND PROPERTY LOSS OR DAMAGE FROM HAZARDS OF FIRE, EXPLOSION, BURN, ASPHYXIATION, CARBON MONOXIDE POISONING, AND/OR ELECTRICAL SHOCK.
ONLY PERSONS WHO CAN UNDERSTAND AND FOLLOW THE INSTRUCTIONS SHOULD USE OR SERVICE THIS HEATER.
IF YOU NEED ASSISTANCE OR HEATER INFORMATION SUCH AS AN INSTRUCTIONS MANUAL, LABELS, ETC. CONTACT THE MANUFACTURER.
8124B
September 2000
RETAIN THESE INSTRUCTIONS FOR FUTURE REFERENCE
ANSI Z83.7b-1993
Construction Heater
SAFETY INSTRUCTIONS
This is an oil, direct-fired, forced air heater. It's intended use is primarily temporary heating of buildings under construc­tion, alternation or repair.
!
NOT FOR HOME OR RECREATIONAL VEHICLE USE
WARNING
GENERAL PRECAUTIONS
This is a direct-fired forced air heater. Direct-Fired means that all of the combustion products
enter the heated space. Even though this heater operates very close to 100 percent combustion effi­ciency, it still produces small amounts of carbon mon­oxide. Carbon monoxide (called CO) is toxic. We can tolerate small amounts but not a lot. OSHA says that 50 parts per million (ppm) in the air we breathe is okay if it does not average more than that during an 8 hour working period. Regardless, CO can build up in a heated space and failure to provide adequate ventila­tion could result in death. The symptoms of inadequate ventilation are:
headache dizziness burning eyes and nose nausea
dry mouth or sore throat So be sure to follow advice about ventilation in these operating instructions.
Forced Air means that a blower or fan pushes the air through the heater. Proper combustion depends upon this air flow; therefore, the heater must not be revised, modified, or operated with parts removed or missing. Likewise, safety systems must not be circumvented or modified in order to operate the heater.
When the heater is to be operated in the presence of other people the user is responsible for properly acquainting those present with the safety precau­tions and instructions, and of the hazards involved.
SAFETY PRECAUTIONS
1. Check the heater thoroughly for damage. Never operate a damaged heater.
2. Never modify the heater or operate the heater if it has been modified from its original condition.
3. Use only Kerosene or #1 fuel oil. Never use gasoline, naphtha, paint thinner, alcohol or other fuels of any kind.
4. For indoor use only.
5. Use only in well ventilated areas. Provide at least 2 sq. ft. of opening near the floor and 2 sq. ft. of opening near the ceiling.
6. Always keep combustibles, like paper and wood at least 8 ft. from the heater outlet and 3 ft. from the top, sides and inlet. Locate 10 ft. from canvas or plastic coverings and secure them to prevent flapping or movement.
7. Install the heater such that it is not directly exposed to water spray, rain and/or dripping water or wind.
8. Never use in areas normally for habitation and/or where children may be present.
9. Operate only on a stable, level surface.
10. Do not use with ductwork. Do not restrict inlet or exit.
11. Use only the electrical power specified.
12. Use only a properly grounded 3 wire extension cord.
13. Do not move, handle or service while hot or burning.
14. Use only in accordance with State and Federal ordinances.
CAUTION: Hot while in operation. Do not touch. Keep children, clothing and combustibles away.
Page 2
!
WARNING: FIRE, BURN, INHALATION, AND EXPLOSION HAZARD.
KEEP SOLID COMBUSTIBLES, SUCH AS BUILDING MATERIALS, PAPER OR CARDBOARD, A SAFE DISTANCE AWAY FROM THE HEATER AS REC­OMMENDED BY THE INSTRUCTIONS. NEVER USE THE HEATER IN SPACES WHICH DO OR MAY CONTAIN VOLATILE OR AIRBORNE COMBUSTIBLES, OR PRODUCTS SUCH AS GASOLINE, SOLVENTS, PAINT THINNER, DUST PARTICLES OR UNKNOW CHEMICALS.
OPERATING INSTRUCTIONS
UNPACKING
1. Remove all protective material which may have been applied to the heater for shipment.
2. Remove the heater from carton
3. Check the heater for possible shipping damage. If any damage is found immediately notify the dealer from whom you purchased the heater.
ASSEMBLY (For 100,000 and 150,000 BTU/hr
models only) Wheel and handles are found in the shipping carton along with mounting hardware. The wheels, axle and mounting hardware are in a plastic package. Tools required are a 5/16" nutdriver, 3/8" open or adjustable wrench and hammer.
1. Slide the axle (6) through the wheel support frame (3). Install bushing (9) and wheels (7) on the axle.
IMPORTANT: The extended hub of the wheel
should be positioned toward the wheels support frame. Position the cap nuts (8) on the axle ends and gently tap with a hammer to secure.
2. Position the heater on the wheel support frame assembly with the exit end over the wheels.
3. Use four screws (4) and nuts (5) to attach the front handle (1) to the top of the tank flange. The screws will go through the front handle, the tank flange and the wheel support frame. Install the nuts finger-tight-only.
IMPORTANT: Do not tighten nuts until Step 5.
4. Using four screws (2) and nuts (5) install the tank to support (1) as outlined in Step 3.
5. Tighten all nuts.
OPERATION
TO FUEL
IMPORTANT: Before filling fuel tank the first time or after extended storage periods drain the fuel tank of any moisture or condensation.
Fill the fuel tank with clean kerosene, No. 1 fuel oil or No. 1 diesel fuel only. Kerosene is recommended for use when the temperature drops below zero degrees fahrenheit (-18o Celsius). In extremely cold weather, condensation may develop in the tank and it is recom­mended that a tablespoon of de-icer be added for each gallon (4 liters) of fuel in the tank.
When filling the heater use at least 2 gallons (8 liters) of fuel. Be sure heater is level and do not overfill. Use a funnel or can with a long fill spout. WARNING: To avoid fire, wipe up any spilled fuel immediately.
TO LOCATE
WARNING: To avoid fire, place the unit in a level location
away from volatile substances and at a safe distance from combustible materials. Adequate ventilation is essential. Refer to the SAFETY PRECAUTION page for advice on adequate ventilation.
Not suitable for use on wood floors or other combus­tible materials. When used the heater should rest on suitable insulating material at least 1 inch thick and extending 3 feet or more beyond the heater in all directions.
If at any time the heater should fail to start, smoke excessively or fire intermittently, unplug it immediately and consult a qualified service person.
TO START
K50: Plug the heater into a grounded outlet. K100/K150: Turn thermostat to lowest setting. Plug heater into a grounded outlet. Turn thermostat to highest setting (heater will start). Adjust thermostat to desired setting. Heater will cycle on/off, as heat is required.
ITEM PART NO. DESCRIPTION QTY.
1 3424 Handle, Front 1 2 7336 Machine Screw, Blk 4 3 3426 Support Tank 1 4 6977 Machine Screw, Blk 4 5 6037 Kep Nut, Blk 8 6 3439 Axle 1 7 6869 Wheel 2 8 6870 Push Nut 2 9 7333 Spacer 2
In cold weather, starting may be improved by holding a finger over the end of the pressure adjusting screw until the heater starts. This unit is equipped with a circuit breaker located near the power cord. If the unit does not start, check to see that the reset is pressed in.
TO STOP
K50: Unplug the heater. K100/K150: For a short duration shutdown, where temperatures will remain above 0oF, turn thermostat to "off" position. For extended shutdown, or where the temperature can go below 0oF unplug the heater.
TO RESTART
1. Wait 5 minutes.
2. Push reset button
3. If heater continues to cycle off on flame safety, see a service person.
Page 3
SERVICING
A hazardous condition may result if a heater is used that has been modified or is not functioning properly. When the heater is working properly:
o The flame is contained within the heater with
perhaps some yellow tippng from the exit cone.
o There is no strong disagreeable odor, eye
burning or other physical discomfort.
o There is no smoke or soot internal or external
to the heater.
o There are no unplanned or unexplained
shutdowns of the heater.
The parts list and wiring diagram show the heater as it was constructed. Do not use a heater which is different from that shown. Heater performance is effected by air pressure setting. If there is any uncertainty about the air pressure setting, have it checked.
A heater which is not working right must be repaired, but only by a trained, experienced service person. Con­tact the factory for the service center closest to you, phone 909/981-5343.
You may also obtain in warranty or out of warranty service by returning the product freight prepaid to:
Scheu Products Company
8855 Baker Avenue
Rancho Cucamonga, CA 91730
Contact customer service for Return Goods Authori­zation Number.
In warranty products returned to the Service Depart­ment will be repaired with no charge for either parts or labor and will be returned to you freight prepaid. Please include a brief statement indicating date and place of purchase and the nature of the problem, and proof of purchase.
Out of warranty products returned to the Service De­partment will be repaired with a charge for parts and labor and will be returned to you freight collect.
MAINTENANCE
WARNING: To prevent personal injury, unplug the heater form the wall outlet before servicing. For maximum efficiency and trouble-free service make the following periodic maintenance cleaning and in­spections.
DAILY SCHEDULE
1. GENERAL. Make general visual inspection of heater for loose or damaged parts. Check nuts and bolts to insure against looseness caused by vibration or rough handling. Damaged parts should be repaired or re­placed before using heater again. Check heater opera­tion to be sure it is operating normally (See "Servicing" section for description of normal operation).
2. FILTERS. Dirty air or oil filters will cause an imbalance in the air-fuel mixture. The best indication that this condition exists is an increase in odors or difficulty getting your heater to ignite. This heater should never be operated without the filters in place. If required clean filters as described under "500 HR" and "Annual Sched­ules".
500 HOUR SCHEDULE
1. AIR INTAKE FILTER: Remove and wash the filter element with a mild detergent, dry thoroughly and replace. Do not oil the filter element. If your heater is used where there is considerable dust or dirt, clean as often as necessary (approximately 50 hrs.).
2. REMOVE DUST: Clean heater twice a season (more often under dusty conditions). Remove accumulated dust from the transformer, burner, motor and fan blades with compressed air. Wipe area clean with a clean dry cloth. Inspect area to insure all foreign materials are removed, especially around the burner and combustion area.
3. CAD CELL: Clean the glass portion of the cad cell with a soft dry cloth.
4. NOZZLE: Accumulation of dirt from fuel and carbon from the compressor vanes will eventually fill up the passages in the nozzle, resulting in reduction of fuel and air flow. Pressure will gradually increase giving improper fuel-air mixture and excess odor and smoke. If this occurs, replace the fuel nozzle.
5. FUEL TANK: Clean twice a season (during frequently used periods clean twice a month). Drain and flush the fuel tank with clean fuel oil.
6. SPARK PLUG: Remove and clean the spark plug. Ad­just spark plug gap to 1/16".
ANNUAL SCHEDULE
1. AIR OUTPUT FILTER: Remove the air output filter and tap the contaminated side gently on a solid object to remove contaminates. Compressed air or liquids should not be used to clean this filter. Reinstall cleaned filter in filter body in the same position as it was when removed. If the filter appears extremely dirty, replace it with a new filter of the same type. When replacing the filter cover, be sure the gasket is firmly in place and the screws in the filter cover are tight to prevent air leaks.
2. FUEL FILTER: Remove the fuel filter from fuel line and direct compressed air through the filter in the opposite direction of fuel flow. Safety glasses should be worn when using compressed air.
3. AIR AND FUEL LINES: If the air or fuel lines are re­moved during cleaning, be sure all connections are tight before operating unit.
4. AIR PRESSURE SETTING: The air pressure has been properly set at the factory. If the air pressure is out of adjustment, it will most likely be caused by dirty air filters, a partially plugged nozzle, an air leak in the system or improperly set pressure. If adjustment becomes necessary, first determine the
proper pressure setting for your heater which is printed on the serial label, located on the fuel tank. Remove the plug from the air filter cover and attach an accurate pressure gauge calibrated to a maximum reading of 15 PSI. Start the heater and note the pressure reading. If the pressure is low, slowly turn the pressure adjusting screw in (clockwise) until the correct pressure is obtained. If the air pressure is high, turn the adjusting screw out (counter-clockwise) until the pressure is correct.
When correct pressure is reached, unplug the heater,
remove the gauge and replace the plug.
STORAGE
Store the heater in a dry location free from fumes or dust.
At the end of each heating season clean the heater as
described in the MAINTENANCE section. Drain and flush the fuel tank with clean fuel. The manufacturer recom­mends completely filling the tank with fuel for extended storage to minimize condensation inside the tank.
Page 4
HEATER SPECIFICATIONS
MODELS
Input Rating, BTU/hr Type of Fuel
Fuel Consumption, Gal/Hr Air Supply Pressure, psig Fuel Tank Capacity, gals. Electrical Input Minimum Operating Fan Ignition Spark Generator
Electrode Primary Flame Safety
Control Power Cord Size (Length x Width x Height) Net Weight Shipping Weight
50
50,000 Kerosene or #1 Fuel Oil Only .38
3.6 4 115V, 60Hz, 10, 3.5a 100V 1750 rpm, 165 cfm Direct Spark, continuous Ignitor, 7000V.sec. 10ma. Single post electrode
Solid State Control 25-second Timing 1 ft. 30 x 12 x 13
30.5 lbs.
36.0 lbs.
100
100,000 Kerosene or #1 Fuel Oil Only .77 4-1/4 12 115V, 60Hz, 10, 5.5a 100V 3450 rpm, 275cfm Direct Spark, continuous Transformer, 5,000V.sec.
20ma. or ignitor 7000V 1.0 ma
1/16" gap (.063) or single post electrode Solid State Control 25-second Timing 1 ft. 34 x 16 x 25 69 lbs. 74 lbs.
150
150,000 Kerosene or #1 Fuel Oil Only
1.15 5-1/4 12 115V, 60Hz, 10, 5.5a 110V 3450 rpm, 400cfm Direct Spark, continuous Transformer, 5,000V.sec.
20ma. or ignitor 7000V 1.0 ma
1/16" gap (.063) or single post electrode Solid State Control 25-second Timing 1 ft. 38 x 16 x 25 76 lbs. 81 lbs.
WIRING DIAGRAM - K100/K150
WIRING DIAGRAM - K50
7428B
8104A
Page 5
K Heaters
Page 7
INSTRUCTIONS FOR ORDERING PARTS - All parts orders must show heater Model No., Item No., Part No. and Description. We recommend that only parts supplied by the manufacturer be used on this unit. A locally purchased part may appear to be identical, although in reality it might endanger the heater or the persons operating the heater.
Kerosene Heaters Parts List
The heater should be serviced only by a trained, experi­enced service person.
Read the section on "Servicing" before ordering parts. For parts order, call (909) 981-5343.
Item Part No. Part No. Part No. Description
50 100 150
1 1036 1036 1036 Power Cord Assembly 2 1676 1400 1400 Fuel Tank Assembly 3 1679 1773 1783 Radiation Shield Assy. 4 1688 1779 1782 Control Box Assembly 5 1682 1407 1407 Power Pac Assembly 6 1686 3429 3429 Fuel Tube 7 1685 1771 1768 Grille Assembly 8 ------- 1408 1408 Fuel Filter Assembly 9 4011 4011 4011 Oil Cad Cell Bracket 10 3449 3449 3449 Motor Cord Sleeve 11 1756 1777 3795 Bottom Shell 12 3715 3822 3810 Top Shell 13 3704 3500 3417 Motor Mounting Brkt. 14 3705 3818 3705 Ignition Mounting Brkt. 15 ------ 3427 3427 Access Panel 16 ------ 6864 6864 Start Relay 17 3725 3430 3421 Air Tube 18 6225 6225 6225 Snap Bushing 19 1796 1797 1798 High Limit Control Assy. 20 6831 6831 6831 Air Pump Rotor 21 6832 6832 6832 Backing Plate 22 6833 6833 6833 Air Pump Cylinder 23 6834 6834 6834 Nylon Air Pump Insert 24 6835 6835 6835 Air Pump Vane 25 6836 6836 6836 Lower Housing 26 6837 6837 6837 Upper Housing 27 3761 3761 3761 Nozzle Mounting Plate 28 6839 6839 6839 Gasket 29 6842 6842 6842 Adjustment Screw 30 6843 6843 6843 Outlet Filter 31 6844 6844 6844 Inlet Filter 32 6848 6848 6848 O Ring 33 6849 6849 6849 Nylon Pipe Plug 34 6850 6850 6850 Relief Ball, 1/4" Dia. 35 6851 6851 6851 Spring, 24 O.D. x .58 36 6856 6856 6856 Hose Barb Fitting
Item Part No. Part No. Part No. Description
50 100 150
37 6863 6863 6863 Oil Flame Cntrl Assy. 38 6865 6865 6865 Cad Cell Flame Snsr. 39 ------ 1775 1719 Comb.Cmbr.Cyl. Assy. 40 3843 3843 3843 Electrode Mtg. Brkt. 41 6993 6993 6993 Oil Fuel Cap 42 ------ 3423 3423 Start Relay Brkt. 43 7399 6841 6841 Motor, 1/4 HP 44 7417 7417 7417 Nozzle Adapter 45 7421 6885 6866 Fan 46 ------ 6227 6227 Snap Bushing 47 1684 1684 1684 Ignitor Assembly 48 7416 7538 7537 Fuel Air Aspir. Nozzle 49 6223 6223 6223 Strain Relief Bushing 50 1803 1803 1803 Electrode Assembly 51 7429 7429 7429 Extrnl. Retaining Ring * 53 3487 3487 3487 Fuel Cap Gasket 54 6847 6847 6847 Hose Barb Fitting * ------ ------ -----­ * 3707 ------ ------ Left Side Panel * 7094 ------ ------ Clip Handle Mtg. * 7095 ------ ------ Handle, 3 piece * 1683 1683 1683 Lead Wire Assy. Grn. * ------ 1040 1040 Lead Wire Assy. Blk. 61 7424 ------ ------ Snap Bushing, Nylon * ------ ------ 6225 Snap Bushing, Nylon * ------ 6862 6862 Fuel Filter Bushing 64 6838 6838 6838 Screw, Tapping #9 x 1¼ 65 6908 6908 6908 Screw, Machine #10 x 1¼ 66 6906 6906 6906 Screw, Machine #10 x ½ * 1942 1942 Knob Assembly * 2098 2098 Thermostat Panel Assy. * 3441 3441 Bracket Thermostat Mtg. * 1734 1734 Thermostat Assembly * 6070 6070 Clamp Loop
* K50 items may not be located as shown in exploded view or they may not be shown at all.
FOR THE SPC MODELS ONLY
SPC SPC SPC
Item K50 K100 K150 Description
25-1 1802 1805 3846 Lower Housing 26-1 3701 3845 3847 Upper Housing
Page 6
SCHEU PRODUCTS COMPANY, INCORPORATED
Mail: P.O. Box 250, Upland, CA 91785
Plant: 8855 Baker Ave., Rancho Cucamonga, CA 91730
Telephone: 909/981-5343