Kingston Split Oak Log
Models VMLR18 (Shown)
and VMLR24
WARNING: If the information in this manual is not
followed exactly, a fire or explosion may result
causing property damage, personal injury, or
loss of life.
— Do not store or use gasoline or other flammable
vapors and liquids in the vicinity of this or any
other appliance.
— WHAT TO DO IF YOU SMELL GAS
• Do not try to light any appliance.
• Do not touch any electrical switch; do not use
any phone in your building.
• Immediately call your gas supplier from a
neighbor’s phone. Follow the gas supplier’s
instructions.
• If you cannot reach your gas supplier, call
the fire department.
— Installation and service must be performed by
a qualified installer, service agency, or the
gas supplier.
WARNING: Improper installation, adjustment, alteration, service, or maintenance can cause
injury or property damage. Refer to this manual for correct
installation and operational
procedures. For assistance or
additional information consult
a qualified installer, service
agency, or the gas supplier.
WARNING: This appliance is
for installation only in a solidfuel burning masonry or UL127
factory-built fireplace, constructed of noncombustible
material, and connected to a
working flue. (See page 7 for
minimum flue opening.)
WARNING: This is a gas-fired appliance. It uses air (oxygen) from the room in which
it is installed. Provisions for adequate combustion and ventilation air must be
provided. Refer to
This appliance may be installed in an aftermarket* manufactured (mobile) home,
where not prohibited by state or local codes.
* Aftermarket: Completion of sale, not for purpose of resale, from the manufacturer
Air for Combustion and Ventilation
Save this manual for future reference.
section on page 4 of this manual.
®
VENTED NATURAL GAS LOGS
SAFETY
INFORMATION
WARNINGS
WARNING ICON G 001
WARNING: Keep flue open
when operating unit.
IMPORTANT: Read this owner’s
manual carefully and completely
before trying to assemble, operate, or service this log set. Improper use of this log set can cause
serious injury or death from burns,
fire, explosion, electrical shock,
and carbon monoxide poisoning.
DANGER: Carbon monoxide
poisoning may lead to death!
Carbon Monoxide Poisoning: Early signs
of carbon monoxide poisoning resemble the
flu, with headaches, dizziness, or nausea. If
you have these signs, the log set may not be
working properly. Get fresh air at once!
Have log set serviced. Some people are
more affected by carbon monoxide than
others. These include pregnant women,
people with heart or lung disease or anemia,
those under the influence of alcohol, and
those at high altitudes.
Natural Gas: Natural gas is odorless. An
odor-making agent is added to the gas. The
odor helps you detect a gas leak. However,
the odor added to the gas can fade. Gas may
be present even though no odor exists.
Make certain you read and understand all
warnings. Keep this manual for reference. It
is your guide to safe and proper operation of
this log set.
WARNING: Any change to this
log set or its controls can be
dangerous.
1.This appliance, as supplied, is only for
use with the type of gas indicated on
the rating plate. This appliance is convertible for use with propane/LP , using
the GA9000 or GA9100 pilot kit.
2.If you smell gas
• shut off gas supply
• do not try to light any appliance
• do not touch any electrical switch; do
not use any phone in your building
• immediately call your gas supplier
from a neighbor’s phone. Follow the
gas supplier’s instructions
• if you cannot reach your gas supplier ,
call the fire department
3.Never install the log set
• in a recreational vehicle
• where curtains, furniture, clothing, or
other flammable objects are less than
42 inches from the front, top, or sides
of the log set
• in high traffic areas
• in windy or drafty areas
4.Before installing in a solid fuel burning fireplace, the chimney flue and firebox must be cleaned of soot, creosote,
ashes, and loose paint by a qualified
chimney cleaner. Creosote will ignite
if highly heated. Inspect chimney flue
for damage.
5.You must operate this log set with a fireplace screen in place. Make sure fireplace
screen is closed before running log set.
6.This log set is designed to be smokeless. If logs ever appear to smoke, turn
off appliance and call a qualified service person.
eration, slight smoking could occur due
to log curing and the burning of manufacturing residues. Y ou may wish to add
more ventilation by opening a window .
7.To reduce the creation of soot, follow
the instructions in Cleaning and Main-tenance, page 13.
8.Do not allow fans to blow directly into
the fireplace. Avoid any drafts that alter burner flame patterns. Ceiling fans
can create drafts that alter burner flame
patterns. Altered burner patterns can
increase sooting.
Note:
During initial op-
9.Do not use a blower insert, heat exchanger insert or other accessory not
approved for use with this log set.
10. This log set needs fresh, outside air ventilation to run properly. See Air forCombustion and Ventilation, pages 4
through 6.
11. Do not run log set
• where flammable liquids or vapors
are used or stored
• under dusty conditions
12. Do not burn solid fuel in the fireplace
after installing the log set. Do not use
this log set to cook food or burn paper
or other objects.
13. Log set becomes very hot when in use.
Keep children and adults away from hot
surface to avoid burns or clothing ignition. Log set will remain hot for a time
after shutdown. Allow surface to cool
before touching.
14. Carefully supervise young children
when they are in the room with log set.
15. Do not use appliance if any part has been
exposed to or under water. Immediately
call a qualified service technician to inspect the room appliance and to replace
any part of the control system (if using
GA9000 or GA9100) and any gas control which has been under water.
16. To help prevent breakage, new logs
must be broken-in (see Curing Logs
page 12).
17. Turn log set off and let cool before servicing, installing, or repairing. Only a
qualified service person should install,
service, or repair log set.
2
901267
OWNER’S MANUAL
PRODUCT
IDENTIFICATION
Burner
Manifold
Grate
Burner
Pan
Left
Side
Burner
Figure 1 - Product Identification (VMLR24 Shown)
Hearth Kit Model: _____________________________________
Serial Number: _______________________________________
Log Set Model: VMLR18 or VMLR24
LOCAL CODES
Install and use log set with care. Follow all
local codes. In the absence of local codes, use
the latest edition of The National Fuel GasCode, ANS Z223.1, also known as NFPA 54*.
*Available from:
American National Standards Institute, Inc.
1430 Broadway
New York, NY 10018
National Fire Protection Association, Inc.
Batterymarch Park
Quincy, MA 02269
UNPACKING
CAUTION: Do not remove the
metal data plates from the burner
pan. The d ata plates contain important product information.
1.Remove logs, hearth kit, pan materials,
and hardware from carton.
2.Remove all protective packaging applied to logs and base for shipment.
3.Check all items for any shipping damage. If damaged, promptly inform
dealer where you bought the product.
Right Side
Burner
Burner Inlet
Fitting
OPTIONAL
PRODUCT
FEATURES
ON/OFF SAFETY VALVE/
PILOT KIT AND PROPANE/LP
CONVERSION
An optional valve/safety pilot kit with a
piezo ignitor is available for this appliance.
This system requires no matches, batteries,
or other sources to light. You must use this
optional system for LP conversion. See Ac-cessories, page 19.
REMOTE CONTROL READY
(MILLIVOLT) SAFETY VALVE/
PILOT KIT
An optional millivolt valve/safety pilot kit
with a piezo ignitor is available for this
appliance. This system requires no matches,
batteries, or other sources to light. This
system may be connected to a wall switch or
hand-held wireless remote control. See Ac-cessories, page 19.
REMOTE CONTROL
ACCESSORIES
There is an optional hand-held ON/OFF
remote control that can be purchased separately for this log set. You must use the
millivolt valve/safety pilot kit to use remote
accessories with this appliance. See Acces-sories, page 19.
A wall switch is also available for this
appliance. You must use the millivolt valve/
safety pilot kit to use the wall switch with
this appliance. See Accessories, page 19.
901267
3
®
VENTED NATURAL GAS LOGS
AIR FOR
COMBUSTION AND
VENTILATION
WARNING: This appliance
shall not be installed in a confined space or unusually tight
construction unless provisions
are provided for adequate combustion and ventilation air. Read
the following instructions to insure proper fresh air for this and
other fuel-burning appliances in
your home.
Today’s homes are built more energy efficient than ever. New materials, increased
insulation, and new construction methods
help reduce heat loss in homes. Home owners
weather strip and caulk around windows and
doors to keep the cold air out and the warm air
in. During heating months, home owners
want their homes as airtight as possible.
While it is good to make your home energy
efficient, your home needs to breathe. Fresh
air must enter your home. All fuel-burning
appliances need fresh air for proper combustion and ventilation.
Exhaust fans, fireplaces, clothes dryers, and
fuel burning appliances draw air from the
house to operate. You must provide adequate fresh air for these appliances. This
will insure proper venting of vented fuelburning appliances.
PROVIDING ADEQUATE
VENTILATION
The following are excerpts from National
Fuel Gas Code, NFPA 54/ANS Z223.1, Section 5.3, Air for Combustion and Ventilation.
All spaces in homes fall into one of the three
following ventilation classifications:
1.Unusually Tight Construction
2.Unconfined Space
3.Confined Space
The information on pages 4 through 6 will
help you classify your space and provide
adequate ventilation.
Unusually Tight Construction
The air that leaks around doors and windows may provide enough fresh air for
combustion and ventilation. However, in
buildings of unusually tight construction,
you must provide additional fresh air.
Unusually tight construction is defined as construction where:
a. walls and ceilings exposed to the
outside atmosphere have a continuous water vapor retarder with
a rating of one perm (6x10
per pa-sec-m2) or less with openings gasketed or sealed
b. weather stripping has been
added on openable windows and
doors
c. caulking or sealants are applied
to areas such as joints around
window and door frames, between sole plates and floors, between wall-ceiling joints, between wall panels, at penetrations for plumbing, electrical, and
gas lines, and at other openings.
If your home meets all of the three
criteria above, you must provide additional fresh air. See
From Outdoors
If your home does not meet all of the
three criteria above, proceed to
and
Ventilation Air
, page 6.
termining Fresh-Air Flow For Appliance Location
, page 5.
and
-11
kg
De-
Confined and Unconfined Space
The National Fuel Gas Code, ANS Z223.1
defines a confined space as a space whose
volume is less than 50 cubic feet per 1,000
Btu per hour (4.8 m3 per kw) of the aggregate input rating of all appliances installed
in that space and an unconfined space as a
space whose volume is not less than 50
cubic feet per 1,000 Btu per hour (4.8 m3 per
kw) of the aggregate input rating of all
appliances installed in that space. Rooms
communicating directly with the space in
which the appliances are installed*, through
openings not furnished with doors, are considered a part of the unconfined space.
This log set shall not be installed in a confined space or unusually tight construction
unless provisions are provided for adequate
combustion and ventilation air.
* Adjoining rooms are communicating only
if there are doorless passageways or ventilation grills between them.
4
901267
OWNER’S MANUAL
AIR FOR
COMBUSTION AND
VENTILATION
Continued
DETERMINING FRESH-AIR FLOW FOR APPLIANCE LOCATION
Determining if You Have a Confined or Unconfined Space
Use this work sheet to determine if you have a confined or unconfined space.
Space: Includes the room in which you will install appliance plus any adjoining rooms with doorless passageways or ventilation grills
between the rooms.
1.Determine the volume of the space (length x width x height).
Length x Width x Height = _________________cu. ft. (volume of space)
Example:
If additional ventilation to adjoining room is supplied with grills or openings, add the volume of these rooms to the total volume of
the space.
2.Divide the space volume by 50 cubic feet to determine the maximum Btu/Hr the space can support.
_____________ (volume of space) ÷ 50 cu. ft. = (maximum Btu/Hr the space can support)
Example:
3.Add the Btu/Hr of all fuel burning appliances in the space.
Gas fireplace logs_____________ Btu/Hr
Gas water heater*_____________ Btu/Hr
Gas furnace_____________ Btu/Hr
Vented gas heater_____________ Btu/Hr
Vent-free heater_____________ Btu/Hr
Other gas appliances* + _____________ Btu/Hr
Total = _____________ Btu/Hr
* Do not include direct-vent gas appliances. Direct-vent draws combustion air from the outdoors and vents to the outdoors.
4.Compare the maximum Btu/Hr the space can support with the actual amount of Btu/Hr used.
_____________ Btu/Hr (maximum the space can support)
_____________ Btu/Hr (actual amount of Btu/Hr used)
Example:
The space in the above example is a confined space because the actual Btu/Hr used is more than the maximum Btu/Hr the space can support.
You must provide additional fresh air. Your options are as follows:
A. Rework worksheet, adding the space of an adjoining room. If the extra space provides an unconfined space, remove door to adjoin-
ing room or add ventilation grills between rooms. See Ventilation Air Fr om Inside Building, page 6.
B. Vent room directly to the outdoors. See Ventilation Air From Outdoors, page 6.
C. Install a lower Btu/Hr heater, if lower Btu/Hr size makes room unconfined.
If the actual Btu/Hr used is less than the maximum Btu/Hr the space can support, the space is an unconfined space. You will need no
additional fresh air ventilation.
Space size 20 ft. (length) x 16 ft. (width) x 8 ft. (ceiling height) = 2560 cu. ft. (volume of space)
2560 cu. ft. (volume of space) ÷ 50 cu. ft. = 51.2 or 51,200 (maximum Btu/Hr the space can support)
Example:
Gas water heater40,000 Btu/Hr
Gas fireplace logs +55,000 Btu/Hr
Total= 95,000 Btu/Hr
51,200 Btu/Hr (maximum the space can support)
95,000 Btu/Hr (actual amount of Btu/Hr used)
WARNING: If the area in which the appliance may be operated is smaller than that defined as an unconfined
space or if the building is of unusually tight construction, provide adequate combustion and ventilation air by one
of the methods described in the
901267
National Fuel Gas Code, ANS Z223.1, Section 5.3
5
or applicable local codes.
Continued
®
VENTED NATURAL GAS LOGS
AIR FOR
COMBUSTION AND
VENTILATION
Continued
VENTILATION AIR
Ventilation Air From Inside
Building
This fresh air would come from an adjoining
unconfined space. When ventilating to an
adjoining unconfined space, you must provide two permanent openings: one within
12" of the ceiling and one within 12" of the
floor on the wall connecting the two spaces
(see options 1 and 2, Figure 2). You can also
remove door into adjoining room (see option 3, Figure 2). Follow the National Fuel
Gas Code, NFPA 54/ANS Z223.1, Section
5.3, Air for Combustion and Ventilation for
required size of ventilation grills or ducts.
WARNING: Rework worksheet, adding the space of the
adjoining unconfined space. The
combined spaces must have
enough fresh air to supply all
appliances in both spaces.
Ventilation Air From Outdoors
Provide extra fresh air by using ventilation
grills or ducts. You must provide two permanent openings: one within 12" of the
ceiling and one within 12" of the floor.
Connect these items directly to the outdoors
or spaces open to the outdoors. These spaces
include attics and crawl spaces. Follow the
National Fuel Gas Code, NFPA 54/ANS
Z223.1, Section 5.3, Air for Combustion and
Ventilation for required size of ventilation
grills or ducts.
IMPORTANT:
inlet or outlet air into attic if attic has a
thermostat-controlled power vent. Heated air
entering the attic will activate the power vent.
Do not provide openings for
Ventilation
Grills
Into Adjoining
Room,
Option 1
Figure 2 - Ventilation Air from Inside Building
Or
Remove
Door into
Adjoining
Room,
Option
3
12"
Outlet
Air
Ventilation Grills
Into Adjoining Room,
Ventilated
Attic
Outlet
Air
Inlet
Air
Inlet Air
Figure 3 - Ventilation Air from Outdoors
Crawl Space
12"
Option 2
To Attic
To
Crawl
Space
Ventilated
6
901267
OWNER’S MANUAL
INSTALLATION
CAUTION: Do not remove
the metal data plates attached
to the burner pan. The data plates
contain important warranty information.
WARNING: Before installing
in a solid fuel burning fireplace,
the chimney flue and firebox must
be cleaned of soot, creosote,
ashes and loose paint by a qualified chimney cleaner. Creosote
will ignite if highly heated. A dirty
chimney flue may create and distribute soot within the house. Inspect chimney flue for damage.
NOTICE: Installation, service, and
repair of this appliance must be
performed by a qualified installer,
service agency, company or gas
supplier experienced with this
type of gas appliance. Only factory authorized components listed
in these instructions may be used
in accordance with the
manufacturer’s instructions and
all codes and requirements of the
authority having jurisdiction. Any
modifications to this kit, or use of
unauthorized components or accessory items will void the
manufacturer’s warranty, and may
result in a hazardous condition.
FLUE OPENING
SPECIFICATIONS
Note:
This vented appliance must be in-
stalled only in a solid-fuel burning fireplace
with a working flue and constructed of noncombustible material.
The charts in Figure 4 indicate technical
information regarding the installation of
your gas log set. Please make sure that all of
the specifications shown are applicable before installation is attempted.
The fireplace must include a working flue
and venting system with the minimum openings shown in the Figure 4.
Use only natural gas. If your gas supply is not
natural gas, you must install ON/OFF Safety
Valve/Pilot Kit (see Accessories, page 19).
Call dealer where you bought log set.
If the fireplace does not have a gas supply
shut-off valve, one must be installed.
Btu Input
Propane Gas
BURNER ORIFICE
LOGNATURALPROPANE/LP
SIZEIN.NUM.IN.NUM.
18".11134.07349
24".12930.086 44
Minimum
Vent Opening
VENTING SPECIFICATIONS
FOR INSTALLATION
The fireplace chimney flue and vent must be
drafting properly. To check the vent for
proper drafting: Light a tightly rolled newspaper on one end and place it at the inside
front edge of the fireplace. Observe the
smoke and be sure the vent is properly
drawing it up the chimney. If the smoke
spills out into the room, extinguish the flame
and remove any obstruction until proper
venting is achieved.
The chimney flue must remain open a minimum of 3" at all times during the operation
of this log set.
Continued
901267
7
®
VENTED NATURAL GAS LOGS
INSTALLATION
Continued
INSTALLING DAMPER
CLAMP
Secure the damper stop clamp provided to
the leading edge of the damper as shown in
Figure 5. If for any reason this clamp doesn't
work on your fireplace, another suitable
clamp or permanent stop must be installed,
or the damper blade must be cut or removed.
Damper Clamp
Damper
Masonry Fireplace
Damper
Clamp
Manufactured
Fireplace
Damper
Damper
CAUTION: Use only new,
black iron or steel pipe. Internally-tinned copper tubing may
be used in certain areas. Check
your local codes. Use pipe of 1/2"
diameter or greater to allow
proper gas volume to log set. If
pipe is too small, undue loss of
pressure will occur.
Installation must include an equipment
shutoff valve, union, and plugged 1/8" NPT
tap. Locate NPT tap within reach for test
gauge hook up. NPT tap must be upstream
from log set (see Figure 6).
IMPORTANT:
Install equipment shutoff
valve in an accessible location. The equipment shutoff valve is for turning on or
shutting off the gas to the appliance.
Apply pipe joint sealant lightly to male
threads. This will prevent excess sealant
from going into pipe. Excess sealant in pipe
could result in a clogged burner injector.
Approved
Gas Hose
CSA Design-Certified
Equipment Shutoff
Valve With 1/8" NPT
Tap*
CAUTION: Use pipe joint sealant that is resistant to liquid petroleum (LP) gas.
We recommend that you install a sediment
trap in supply line as shown in Figure 6.
Locate sediment trap where it is within
reach for cleaning. Install in piping system
between fuel supply and heater. Locate sediment trap where trapped matter is not likely
to freeze. A sediment trap traps moisture
and contaminants. This keeps them from
going into log set controls. If sediment trap
is not installed or is installed wrong, log set
may not run properly.
CHECKING GAS
CONNECTIONS
WARNING: Test all gas piping and connections for leaks
after installing or servicing. Correct all leaks at once.
WARNING: Never use an
open flame to check for a leak.
Apply a mixture of liquid soap
and water to all joints. Bubbles
forming show a leak. Correct all
leaks at once.
Figure 5 - Attaching Damper Clamp
CONNECTING TO GAS
SUPPLY
WARNING: A qualified service person must connect log set
to gas supply. Follow all local
codes.
Installation Items Needed
Before installing log set, make sure you
have the items listed below.
• piping (check local codes)
• sealant (resistant to propane/LP gas)
• equipment shutoff valve
• test gauge connection
• adjustable (crescent) wrench or pliers
• sediment trap
• tee joint
• pipe wrench
From Gas
Meter (5"
W.C.** to
10.5" W.C.
3" Minimum
Cap
Pipe Nipple
Sediment Trap
Figure 6 - Gas Connection
Pressure)
Tee Joint
* Purchase the optional CSA design-certified equipment shutoff valve from your
dealer. See Accessories, page 19.
** Minimum inlet pressure for purpose of
input adjustment.
8
Pressure Testing Gas Supply
Piping System
Test Pressures In Excess Of 1/2 PSIG
(3.5 kPa)
1.Disconnect appliance with its appliance
main gas valve (control valve) and equipment shutoff valve from gas supply piping system. Pressures in excess of 1/2 psig
will damage heater regulator.
2. Cap off open end of gas pipe where
equipment shutoff valve was connected.
3.Pressurize supply piping system by either
using compressed air or opening main gas
valve located on or near gas meter.
4.Check all joints of gas supply piping
system. Apply mixture of liquid soap
and water to gas joints. Bubbles forming show a leak.
5.Correct all leaks at once.
6. Reconnect log set and equipment
shutoff valve to gas supply. Check reconnected fittings for leaks.
901267
OWNER’S MANUAL
INSTALLATION
Continued
Test Pressures Equal To or Less Than
1/2 PSIG (3.5 kPa)
1.Close equipment shutoff valve (see Figure 7).
2.Pressurize supply piping system by either
using compressed air or opening main gas
valve located on or near gas meter.
3.Check all joints from gas meter to equipment shutoff valve (see Figure 7). Apply
mixture of liquid soap and water to gas
joints. Bubbles forming show a leak.
4.Correct all leaks at once.
Equipment Shutoff
Valve
Gas Meter
Figure 7 - Checking Gas Joints
HEARTH KIT ASSEMBLY
AND INSTALLATION
Kit Assembly
1. Unscrew burner inlet fitting from
burner manifold.
2. Place burner manifold in pan with
threaded opening facing open knockout plug (see Figure 8). Make sure the
burner ports face downward.
3. Using thread sealant (resistant to the
action of propane/LP gas) on larger
end of fitting, screw the burner inlet
fitting through hole and into burner
manifold. Tighten using a wrench. If
using propane/LP gas, see Propane/LPGas Conversion, pages 10 and 11.
4.If using optional GA9000 kit, go to Op-
tional GA9000 On/Off Safety V alve/Pilot Kit section for installation instruc-
tions. If using optional GA9100 kit,
follow instructions included with kit for
installation and operation.
5. Using thread sealant on the male
threads, install the burner connection
fittings into the 1/8" NPT holes on each
side of the burner manifold.
6.Press the right and left side burners onto
the burner connection fittings. The
burner porting should face downward
(see Figure 8).
Burner
Connection
Fittings
Figure 8 - Installing Burner
Burner Manifold
Side
Burners
Burner Inlet
Fitting
Installation and Gas Connection
1.Place the burner pan assembly in the
center of the fireplace floor. Make sure
the inlet end of the pan faces the gas
supply.
2. Thread the gas supply fitting to the
fireplace gas supply pipe. Use thread
sealant.
3. Install adapter fitting onto the burner
inlet fitting using thread sealant on
male threads of burner inlet fitting
(see Figure 9). Adjust to most convenient position.
4.Install the gas connector tube to the gas
supply fitting. Carefully shape tube to
attach to adapter fitting. Be careful not
to cause kinks in tube.
5.Using the 1/4" x #8 provided, install
the cover over the inlet fitting.
For additional convenience and safety, or
for propane/LP conversion, an optional ON/
OFF safety valve/pilot kit is available. See
Accessories, page 19.
WARNING: You must use a
ON/OFF safety valve/pilot kit for
propane/LP conversion.
Note:
The control cover provided with the
GA9000 should be discarded and replaced
with the one provided with the log set.
Natural Gas Installation
1.Thread the gas control valve onto the
burner inlet fitting (see Figure 10). Use
thread sealant on the male threads of
the burner inlet fitting. Hold the burner
inlet fitting with a wrench to prevent
overtightening the connection to the
burner. Make sure the control rod is
facing the front (see Figure 10).
Gas
Control
Valve
Burner Pan
Assembly
Figure 10 - Installing Gas Control Valve
Burner Inlet
Fitting
Control Rod
901267
Continued
9
®
VENTED NATURAL GAS LOGS
INSTALLATION
Continued
2.Attach the pilot gas line to the pilot outlet of the gas control valve and tighten.
Connect the thermocouple to the rear of
the gas control valve. See Figure 11. Do
not overtighten. If using propane/LP gas,
see Changing Pilot Orifice, page 11.
3. Install the inlet fitting into the inlet
opening of the gas control valve (see
Figure 12). Use thread sealant on the
male pipe threads.
4.Place the burner pan assembly in the
center of the fireplace floor. Make sure
front of pan faces the room from which
you wish to control the appliance.
5.Thread the gas supply fitting to the fireplace gas supply pipe. Adjust to most
convenient position.
6.
Install the gas connector tube to the gas
supply fitting. Carefully shape tube to
attach to adapter fitting. Be careful not
to cause kinks in tube.
7.Test for leaks following instructions
under Testing Burner for Leaks, page 1 1.
8.
Retighten and adjust the location of the
gas control as necessary. The gas control should be level, with the control rod
to the front.
9.Install cover, provided with log set, to
burner pan using screws provided.
10. Install thermocouple, pilot, and ignitor
onto valve cover as shown in Figure 13.
Use the provided screws.
11. Push the control rod extension onto the
“D” shaped control rod through the center hole in the cover.
12.
Install the position decal and control
knob making sure to align the marks
with the correct stop positions of the
gas control. Pilot position will allow
the knob to push in about 1/2". Align
the decals in the pilot position.
Gas
Connector
Tube
Screw
Inlet
Opening
Thermocouple
Gas Inlet
Fitting
Pilot
Gas Control
Valve
Figure 12 - Installing Inlet Fitting and Gas
Connector Tube
Ignitor
Propane/LP Gas Conversion
To convert to propane/LP gas, the burner
inlet fitting and pilot orifice must be replaced. The propane/LP burner inlet fitting is
supplied with the orifice installed for a 24"
log set. If you have an 18" set, you must
change this orifice also. See Figure 1, page 3
for product identification.
Burner Inlet Fitting
1.Remove the burner inlet fitting from the
burner pan assembly (see Figure 14).
DO NOT remove the orifice from this
fitting. The propane/LP burner inlet fitting is included in the hardware kit (see
Figure 15).
2.Be sure to use the correct orifice for your
appliance. The hardware kit included
with this appliance contains two orifices
with a cone-like shape. If you have an
18" set, the orifice for the burner inlet
fitting is red. If you have a 24" log set,
the orifice is already installed inside the
fitting. The black orifice will not be
used in any multi-side unit and may be
discarded.
Burner Inlet Fitting
for Natural Gas
Thermocouple
and Line
Pilot and Line
Gas Control
Valve
Figure 11 - Gas Control Valve with Thermocouple and Pilot
Valve Cover
Piezo Ignitor
Control
Knob
Figure 13 - Installing Cover, Control Knob,
and Piezo Ignitor
Control Rod
Extension
10
Figure 14 - Remove Burner Inlet Fitting
Injector for
Natural Gas
NATURAL
GAS
FITTING
Figure 15 - Burner Inlet Fittings with
Injectors
Injector for
Propane/LP
Gas
PROPANE/
LP GAS
FITTING
901267
OWNER’S MANUAL
INSTALLATION
Continued
3.For an 18" set, use a 10mm socket or
nut driver to remove the orifice from
the propane/LP burner inlet fitting.
Choose the correct orifice for your log
set size and install in place of the orifice you just removed.
4.Using thread sealant (resistant to the
action of propane/LP gas) on larger end
of fitting, screw the burner inlet fitting
through hole and into burner manifold.
Tighten using a wrench.
5 . Follow steps 1 through 12 under Natu-
ral Gas Installation, pages 9 and 10.
Changing Pilot Orifice
The pilot is provided with a natural gas
orifice installed. For propane/LP gas you
must remove it and replace it with an propane/LP orifice. The hardware kit contains
an propane/LP orifice with a red stripe for
converting the pilot.
1. Gently loosen and remove the pilot
line connection from the bracket (see
Figure 16).
2. Replace the injector (see Figure 16)
with the propane/LP pilot injector with
the red stripe.
3.Replace and tighten the pilot line to the
bracket.
4. Continue with step 3 under NaturalGas Installation, pages 9 and 10.
Pilot
Injector
TESTING BURNER FOR
LEAKS
1.Generously apply soapy solution to all
connections.
WARNING: Never check for
gas leaks with open flame.
2.Light the burner with the shutoff valve
no more than half open and holding a
match slightly in front of the pan (see
Lighting Instructions, page 12).
3.Inspect all connections for bubbles, raw
gas odor, or flame from any area other
than the burner (leaks). If leaks are detected, shut off the gas valve immediately. Tighten, or reassemble the loose
connection(s) using pipe joint compound until burner system is leak free.
4.When the burner is tested and leak free,
observe the individual tongues of flame
on the burner.
includes more ports on the outside of the
bar. Make sure that all ports are clear
and producing flame evenly across the
burner. If any ports appear blocked, clear
them by removing the burner manifold
and reaming the ports with a modified
paper clip or other suitable tool.
5. When finished testing, turn the gas
shutoff valve OFF to extinguish all
flames.
Note:
The burner design
ADDING PAN MATERIAL
1.Open the bags of ash bed material (vermiculite) and spread it evenly across the
burner pan to the top. You may overflow the front and sides of the pan to
cover the entire pan and connecting
hardware. Do not cover GA9000 or
GA9100 valve.
2.Open the glowing embers and evenly
cover the ash bed material (vermiculite) in the burner pan.
INSTALLING THE GRATE
AND LOGS
1.Place the grate over the burner pan. The
grate should “lock” into place over the
corners of the pan (see Figure 17).
2. Place one of the bottom logs on the
grate and slide forward against the front
grate bars. Repeat for other side (see
Figure 18).
5.Place the smaller top logs onto the bottom logs (see Figure 19). Leave as
much open space between logs as possible to minimize flame impingement
and sooting.
they are handled roughly or if hit together while being placed.
Grate
Burner
Pan
Figure 17 - Installing Grate (Pan Material
Not Shown)
Figure 18 - Placement of Bottom Logs
Note:
Logs may chip if
Figure 16 - Installing Propane/LP Pilot
Orifice
901267
Figure 19 - Placement of Top Logs
11
®
VENTED NATURAL GAS LOGS
OPERATING
APPLIANCE
FOR YOUR SAFETY
READ BEFORE
LIGHTING
WARNING: Keep flue open
when operating unit.
WARNING: If you do not follow these instructions exactly, a
fire or explosion may result causing property damage, personal
injury or loss of life.
BEFORE LIGHTING smell all around
the appliance area for gas. Be sure to
smell next to the floor because some gas is
heavier than air and will settle on the
floor.
WHAT TO DO IF YOU SMELL GAS
• Do not try to light any appliance.
• Do not touch any electric switch; do
not use any phone in your building.
• Immediately call your gas supplier
from a neighbor’s phone. Follow the
gas supplier’s instructions.
• If you cannot reach y our gas supplier,
call the fire department.
LIGHTING
INSTRUCTIONS
1.STOP! Read the safety information,
above.
2.Turn the gas shutoff valve to OFF.
3.Wait f ive (5) minutes to clear out any
gas. If you then smell gas STOP! F ollow the safety information above. If
you don‘t smell gas, go on to the next
step.
4.Light a match and lay it on top of
the pan material about 2" from the
end of the supply side of the pan
5.Slowly turn the gas shutoff valve ON
until the burner ignites. If the bur ner
doesn’t ignite within 10 seconds with
the match burning, turn the shutoff
valve OFF and repeat steps 1 through
4 again.
GAS SHUTOFF
VALVE OPERATION
Flame Adjustment
1.Adjust the flame ON/OFF by turning the gas shutoff valve counterclockwise to open or clockwise to close, as necessary.
Shutting Off Appliance
1. Turn gas shutoff valve clockwise
to the OFF position.
CURING LOGS
During the 2-3 hour appliance break-in
period, you may detect an odor from the
appliance as the various paints and compounds used in the manufacturing of this
log set cure. This is a normal and temporary situation that is not cause for alarm.
However, you may want to provide extra
ventilation to the room during this time.
To ensure proper curing of the logs:
• Ignite a 2" flame and maintain it for 1
hour .
• Burn the logs in consecutive 1 hour pe-
riods raising the flame an additional
2" to full flame height for a total of
three hours.
OPERATING
INSTRUCTIONS FOR
GA9000
Note:
Operation instructions for GA9100
Remote Ready Valve/Pilot Kit will be
included with the kit.
1.STOP! Read the safety information,
column one this page.
2.Make sure equipment shutoff valve
is fully open.
3.Press in and turn control knob clock-
wise to the OFF position.
4.Wait f ive (5) minutes to clear out an y
gas. Then smell for gas ar ound log set
and near floor. If you smell gas,
STOP! See Safety information, page 2
and Air For Combustion And Ventila-tion, pages 4 through 6. If you don’t
smell gas, go to the next step.
5. T ur n control knob counterclockwise
to the PILOT position and
press in. Keep control knob pressed
in for five (5) seconds.
Note:
You ma y be running this log
set for the first time after hooking up
to gas supply . If so, the contr ol knob
may need to be pressed in for 30 seconds. This will allow air to bleed from
the gas system.
• If control knob does not pop up
when released, contact a qualified
service person or gas supplier for
repairs.
6.With control knob pressed in, push
down and release ignitor button. This
will light pilot. The pilot is attached
to the rear of the front burner. If
needed, keep pressing ignitor button
until pilot lights.
Note:
If pilot does not stay lit, contact a qualified service person or gas
supplier for repairs. Until repair s are
made, light pilot with match.
7.Keep control knob pressed in for 30
seconds after lighting pilot. After 30
seconds, release control knob.
Note:
If pilot goes out, repeat steps
3 through 7.
8.T urn contr ol knob counterclockwise
to the ON position. Burner
should light. If burner does not light,
call a qualified service person.
Ignitor
Figure 20 - Ignitor and Control Knob
Pilot
Figure 21 - Thermocouple and Pilot
Control Knob
Pilot
ON
FROM "PILOT" POSITION
SLIGHT PUSH TO
TURN OFF
On
PULL PUSH
TURN OFF
PULL PUSH
SLIGHT PUSH TO
FROM "PILOT" POSITION
ONOFF
OFF
Off
ON
FROM "PILOT" POSITION
SLIGHT PUSH TO
PULL PUSH
TURN OFF
OFF
Thermocouple
12
901267
OWNER’S MANUAL
OPERATING
APPLIANCE
Continued
TO TURN OFF GAS
TO APPLIANCE
Shutting Off Appliance
1.T urn control knob clockwise
to the PILOT position.
2.Press in and turn control clockwise
to the OFF position.
Shutting Off Burner Only (pilot
stays lit)
Turn control knob clockwise to
the PILOT position.
TROUBLESHOOTING
Note:
For additional help, visit DESA
International’s Technical Service web
site at www.desatech.com.
Note:
All troubleshooting items are listed in
order of operation.
CLEANING AND
MAINTENANCE
• Keep the area around the log set clean
and clear of debris.
• Occasionally, you may use a soft bristle
brush to clean logs.
• Once every year a qualified agency or
certified chimney sweep should examine and clean the venting system of the
fireplace.
WARNING: Turn off log set
and let cool before servicing. Only
a qualified service person should
service and repair log set.
OBSERVED PROBLEM
Log set is smoking/sooting excessively
(
Note:
It is natural and unavoidable for
vented gas log sets to produce moderate
levels of carbon (soot) where flames
contact the logs. This is especially true
with propane/LP gas.)
Burner is excessively noisy
(
Note:
The movement and combustion of
gas will create low, unavoidable levels of
noise.)
Burner flame is too low or too high
POSSIBLE CAUSEREMEDY
1. Poor fuel quality
2. Fireplace venting system not drafting
properly
3. Excessive flame impingement or
blockage
4. Improper fuel/air mixture
5. Excessive gas supply/pressure
1. Passage of air/gas across irregular surfaces
1. Incorrect gas supply or pressure
2. Blocked burner orifice or burner manifold ports
3. Improper burner orifice size
1. Contact local natural or propane/LP gas
company
2. Adjust damper wide open and/or have
fireplace and venting professionally
cleaned and checked
3. Separate the logs to allow more flame
passage
4. Remove any foreign items from the
flame pattern and/or check for proper
orifice sizing
5. Preheat flue in very cold weather
1. Relieve any tight bends or kinks in gas
supply line
1. Check for proper gas supply pressure
2. Free burner orifice and manifold ports
of any burrs, paint, or other blockage
When ignitor button is pressed, there is no
spark at pilot (GA9000 Only)
When ignitor button is pressed, there is
spark at pilot but no ignition (GA9000 Only)
Pilot lights but flame goes out when control
knob is released (GA9000 Only)
POSSIBLE CAUSE
1. Ignitor electrode not connected to ignitor cable
2. Ignitor cable pinched or wet
3. Bad ground on piezo ignitor
4. Broken ignitor cable
5. Bad piezo ignitor
6. Ignitor electrode broken
7. Ignitor electrode positioned wrong
1. Gas supply turned off or equipment
shutoff valve closed
2. Control knob not in PILOT position
3. Control knob not pressed in while in
PILOT position
4. Air in gas lines when installed
5. Pilot adjustment screw closed
6. Pilot is clogged
7. Low gas pressure
1. Control knob not fully pressed in
2. Control knob not pressed in long enough
3. Equipment shutoff valve not fully open
4. Pilot flame not touching thermocouple,
which allows thermocouple to cool,
causing pilot flame to go out. This problem could be caused by one or both of
the following:
A) Low gas pressure
B) Dirty or partially clogged pilot
5. Thermocouple connection loose at control valve
6. Thermocouple damaged
7. Control valve damaged
REMEDY
1. Reconnect ignitor cable
2. Free ignitor cable if pinched by any
metal or tubing. Keep ignitor cable dry
3. Scrape away paint on bracket for better
contact with ground on piezo ignitor
4. Replace ignitor cable
5. Replace piezo ignitor
6. Replace electrode
7. Reposition electrode
1. Turn on gas supply or open equipment
shutoff valve
2. Turn control knob to PILOT position
3. Press in control knob while in PILOT
position
4. Continue holding down control knob.
Repeat igniting operation until air is removed
5. Adjust pilot flame for approximately
2" blue flame
6. Clean pilot (see Cleaning and Mainte-nance, page 13) or replace pilot assembly
7. Replace gas control
1. Press in control knob fully
2. After pilot lights, keep control knob
pressed in 30 seconds
3. Fully open equipment shutoff valve
4. A) Contact local natural gas company
B) Clean pilot (see Cleaning and
Maintenance, page 13) or replace pilot
assembly
5. Hand tighten until snug, then tighten
1/4 turn more
6. Replace thermocouple
7. Replace control valve
Burner does not light after pilot is lit
(GA9000 Only)
Delayed ignition burner (GA9000 Only)
1. Burner orifice clogged
2. Inlet gas pressure is too low
3. Burner orifice diameter is too small
4. Thermocouple leads disconnected or improperly connected
1. Pilot flame needs adjusting
2. Wrong pilot orifice
www.desatech.com
14
1. Clean burner orifice
2. Contact local natural or propane/LP gas
company
3. Replace burner orifice
4. Reconnect leads
1. Adjust pilot flame for approximately
2" blue flame
2. Replace pilot orifice set
901267
TROUBLESHOOTING
Continued
WARNING: If you smell gas
• Shut off gas supply.
• Do not try to light any appliance.
• Do not touch any electrical switch; do not use any phone in
your building.
• Immediately call your gas supplier from a neighbor’s phone.
Follow the gas supplier’s instructions.
• If you cannot reach your gas supplier, call the fire department.
OWNER’S MANUAL
IMPORTANT:
Cleaning supplies, paint, paint remover, cigarette smoke, cements and glues, new
carpet or textiles, etc., create fumes. These fumes may mix with combustion air
and create odors. These odors will disappear over time.
OBSERVED PROBLEM
Log Set produces a clicking/ticking noise
just after burner is lit or shut off
Log Set produces unwanted odors
Gas odor even when control knob is in OFF
position
Gas odor during combustion
Operating log set where impurities in air exist may create odors.
POSSIBLE CAUSE
1. Metal expanding while heating or contracting while cooling
1. Log Set burning vapors from paint, hair
spray, glues, cleaners, chemicals, new
carpet, etc. (See
ment above)
2. Gas leak. See W arning statement at
top of page
1. Gas leak. See W arning statement at
top of page
2. Control valve defective
1. Gas leak. See W arning statement at
top of page
IMPORTANT
state-
REMEDY
1. This is common with most log sets. If
noise is excessive, contact qualified service person
1. Open flue to maximum. Stop using odor
causing products while log set is running
2. Locate and correct all leaks (see Check-ing Gas Connections, page 8)
1. Locate and correct all leaks (see Check-ing Gas Connections, page 8)
2. Replace control valve
2. Locate and correct all leaks (see Check-ing Gas Connections, page 8)
901267
www.desatech.com
15
®
VENTED NATURAL GAS LOGS
ILLUSTRATED
PARTS
BREAKDOWN
VVMR18
VVMR24
7
9
10
10
12
6
11
5
1
8
4
3
16
2
901267
OWNER’S MANUAL
PARTS LIST
VVMR18
VVMR24
This list contains replaceable parts used in your log set. When ordering parts, follow the
instructions listed under Replacement Parts on page 19 of this manual.
KEY PART NUMBER FOR
NO.VVMR18VVMR24DESCRIPTIONQTY.
1901063-01901063-01Brass 3/8 FLR x 1/2 FPT Elbow1
2901057-01901057-01Brass 3/8 FLR x 3/8 FPT Elbow1
3901066-01901066-01Brass Air Mixer - Natural Gas1
4901064-10901064-03Natural Gas Injector1
5901763-02901763-01Burner Manifold1
6901767-02901767-01Burner Pan1
7901242-01901242-01Damper Clamp - Std. Assembly1
8901232-01901232-01Gas Line - 12" Aluminum1
9901800-01901757-01Log Grate1
10901060-01901060-01Burner Connection Fitting2
11901765-03901765-01Right Side Burner1
12901765-04901765-02Left Side Burner1
PARTS AVAILABLE — NOT SHOWN
901156-01901156-01.125# Bag Embers1
901155-01 –1.5# Bag Ash Bed Material
KEY PART NUMBER FOR
NO.VMLR18VMLR24DESCRIPTIONQTY.
1901603-01901604-01Bottom Front 12
2 901593-01901594-01Bottom Front 22
3 901588-01901588-01VS-12 Top Log1
4 —901592-01VCR-12 Top Log1
5901591-02901591-02VCR-11\VC Top Log1
6901551-03901551-03CHR-13\VC Top Log1
7901587-01901587-01VCR-9 Top Log1
This list contains replaceable parts used in your log set. When ordering parts, follow the
instructions listed under Replacement Parts on page 19 of this manual.
6
5
2
Kingston Split Oak Logs
4
3
7
1
18
901267
OWNER’S MANUAL
REPLACEMENT
PARTS
Note:
Use only original replacement parts.
This will protect your warranty coverage for
parts replaced under warranty.
PARTS UNDER WARRANTY
Contact authorized dealers of this product.
If they can’t supply original replacement
part(s), call DESA International’s Technical Service Department at 1-800-323-5190.
When calling DESA International, have
ready
• your name and address
• model and serial numbers of your log set
• how log set was malfunctioning
• type of gas used (propane/LP or natural gas)
• purchase date
Usually, we will ask you to return the defec-
tive part to the factory.
PARTS NOT UNDER
WARRANTY
Contact authorized dealers of this product.
If they can’t supply original replacement
part(s), call DESA International’s Parts
Department at 1-800-972-7879 for referral
information. When calling DESA International, have ready
• model number of your log set
• the replacement part number
ACCESSORIES
Purchase these log set accessories from your
local dealer. If they can not supply these
accessories, call DESA International’s Parts
Department at 1-800-972-7879 for referral
information. You can also write to the address listed on the back page of this manual.
RECEIVER AND HANDHELD REMOTE CONTROL
KIT - GHRC Series
For all models. Allows the gas log set to be
turned on and off by using a hand-held
remote control. Valve/Pilot Kit GA9100
must be used with this remote.
WALL-MOUNT ON/OFF
SWITCH - GWMS2
(Not Shown)
For all models. Allows the gas log set to be
turned on and off with a wall switch when
used with GA9100.
ON/OFF SAFETY VALVE/
PILOT KIT - GA9000
(Not Shown)
For all models. Required for propane/LP
installation.
REMOTE READY VALVE/
PILOT KIT - GA9100
(Not Shown)
For all models.
INDIVIDUAL ROUND LOG
GA9400
(Not Shown)
For all models. Use when more logs are
desired. Carton of 6
INDIVIDUAL SPLIT LOG
GA9500
(Not Shown)
For all models. Carton of 6.
ASH BED MATERIAL
(Vermiculite) - GA9700
(Not Shown)
For all models. Carton of 6.
GLOWING EMBERS - GA9900
(Not Shown)
For all models. Use for firebox decoration
only.
SILICA SAND - GA9800
(Not Shown)
For all models. Use for firebox decoration
only. Carton of 6.
LAVA ROCK - GA6066
(Not Shown)
For all models. Use for firebox decoration
only.
DECORATIVE ASH BED
CONTROL COVER - DABK
(Not Shown)
An attractive way to cover control knob
and piezo ignitor.
18" ORNAMENTAL GRATE
ENHANCER - GA9310
(Not Shown)
For 18" models only. Additional decoration
for front grate.
24" ORNAMENTAL GRATE
ENHANCER - GA9320
(Not Shown)
For 24" models only. Additional decoration
for front grate.
EQUIPMENT SHUTOFF
VALVE - GA5010
For all models. Equipment shutoff valve with
1/8" NPT tap. Fits 1/2" NPT pipe.
901267
PINE CONES - GA9600
(Not Shown)
For all models. Use for additional decoration only. Carton of 6 Boxes (3 pine cones
per box).
19
WARRANTY INFORMATION
KEEP THIS WARRANTY
Model
Serial No.
Date Purchased
Always specify model and serial numbers when communicating with the factory.
We reserve the right to amend these specifications at any time without notice. The only warranty applicable is our standard written
warranty. We make no other warranty, expressed or implied.
LIMITED WARRANTY
VANGUARD VENTED GAS LOGS
DESA International warrants this product to be free from defects on burner system for four (4) years and logs for a lifetime from the
date of first purchase, provided that the product has been properly installed, operated and maintained in accordance with all applicable
instructions. To make a claim under this warranty the Bill of Sale or cancelled check must be presented.
This warranty is extended only to the original retail purchaser. This warranty covers the cost of part(s) required to restore this log set
to proper operating condition and an allowance for labor when provided by a DESA Authorized Service Center. Warranty part(s) MUST
be obtained through authorized dealers of this product and/or DESA International who will provide original factory replacement parts.
Failure to use original factory replacement parts voids this warranty. The log set MUST be installed by a qualified installer in accordance
with all local codes and instructions furnished with the unit.
This warranty does not apply to parts that are not in original condition because of normal wear and tear, or parts that fail or become
damaged as a result of misuse, accidents, lack of proper maintenance or defects caused by improper installation. Travel, diagnostic cost,
labor, transportation and any and all such other costs related to repairing a defective log set will be the responsibility of the owner.
TO THE FULL EXTENT ALLOWED BY THE LAW OF THE JURISDICTION THAT GOVERNS THE SALE OF THE PRODUCT;
THIS EXPRESS WARRANTY EXCLUDES ANY AND ALL OTHER EXPRESSED WARRANTIES AND LIMITS THE DURATION OF ANY AND ALL IMPLIED WARRANTIES, INCLUDING WARRANTIES OF MERCHANTABILITY AND FITNESS
FOR A PARTICULAR PURPOSE TO FOUR (4) YEARS ON BURNER SYSTEM AND A LIFETIME ON LOGS FROM THE DATE
OF FIRST PURCHASE; AND DESA INTERNATIONAL’S LIABILITY IS HEREBY LIMITED TO THE PURCHASE PRICE OF
THE PRODUCT AND DESA INTERNATIONAL SHALL NOT BE LIABLE FOR ANY OTHER DAMAGES WHATSOEVER
INCLUDING INDIRECT, INCIDENTAL OR CONSEQUENTIAL DAMAGES.
Some states do not allow a limitation on how long an implied warranty lasts or an exclusion or limitation of incidental or consequential
damages, so the above limitation on implied warranties, or exclusion or limitation on damages may not apply to you.
This warranty gives you specific legal rights, and you may also have other rights that vary from state to state.
For information about this warranty write:
INTERNATIONAL
2701 Industrial Drive
P.O. Box 90004
Bowling Green, KY 42102-9004
www.desatech.com
901267 01
NOT A UPC
901267-01
Rev. A
04/00
Loading...
+ hidden pages
You need points to download manuals.
1 point = 1 manual.
You can buy points or you can get point for every manual you upload.