Desa VP10A, VN10A, VP600BA, VN600BA, VN1000BTA, VP1000BTA, VN6D, VP5D User Manual
VENT-FREE GAS HEATER
For more information, visit www.desatech.com
For more information, visit www.desatech.com
VN600BA, VP600BA
VN1000BT A, VP1000BTA
VN10A, VP10A
VN10T A, VP10T A
VN6D, VP5D
TM
OWNER’S OPERATION AND
INSTALLATION MANUAL
WARNING: If the information in this manual is not
followed exactly, a fire or explosion may result causing property damage, personal injury, or loss of life.
—Do not store or use gasoline or other flammable
vapors and liquids in the vicinity of this or any
other appliance.
—WHAT TO DO IF YOU SMELL GAS
• Do not try to light any appliance.
• Do not touch any electrical switch; do not use
any phone in your building.
• Immediately call your gas supplier from a
neighbor’s phone. Follow the gas supplier’s
instructions.
• If you cannot reach your gas supplier, call the
fire department.
—Installation and service must be performed by
a qualified installer, service agency, or the gas
supplier.
This appliance may be installed in an aftermarket*, permanently located, manufactured (mobile)
home, where not prohibited by local codes.
This appliance is only for use with the type of gas indicated on the rating plate. This appliance
is not convertible for use with other gases.
*Aftermarket: Completion of sale, not for purpose of resale, from the manufacturer
WARNING: Improper installation, adjustment, alteration, service, or maintenance can cause
injury or property damage. Refer to this manual for correct
installation and operational procedures. For assistance or additional information consult a
qualified installer, service
agency, or the gas supplier.
WARNING: This is an unvented
gas-fired heater. It uses air (oxygen) from the room in which it is
installed. Provisions for adequate
combustion and ventilation air
must be provided. Refer to
Combustion and Ventilation
page 4 of this manual.
Air For
on
Save this manual for future reference.
Save this manual for future reference.
TABLE OF CONTENTS
SAFETY INFORMATION
2
TABLE OF CONTENTS
SAFETY INFORMATION ............................................................ 2
IMPORTANT: Read this owner’s manual carefully and
completely before trying to assemble, operate, or service this heater. Improper use of this heater can cause
serious injury or death from burns, fire, explosion,
electrical shock, and carbon monoxide poisoning.
Due to high temperatures, the appliance should be
located out of traffic and away from furniture and
draperies.
Do not place clothing or other flammable material on
or near the appliance. Never place any objects on the
heater.
DANGER: Carbon monoxide poisoning may lead
to death!
Carbon Monoxide Poisoning: Early signs of carbon monoxide
poisoning resemble the flu, with headaches, dizziness, or nausea. If
you have these signs, the heater may not be working properly. Getfresh air at once! Have heater serviced. Some people are more
affected by carbon monoxide than others. These include pregnant
women, persons with heart or lung disease or anemia, those under
the influence of alcohol, and those at high altitudes.
Natural and Propane/LP Gas: Natural and propane/LP gases are
fuel gases. Fuel gases are odorless. An odor-making agent is added
to fuel gases. The odor helps you detect a fuel gas leak. However,
the odor added to fuel gas can fade. Fuel gas may be present even
though no odor exists.
Make certain you read and understand all warnings. Keep this
manual for reference. It is your guide to safe and proper operation
of this heater.
WARNING: Any change to this heater or its
controls can be dangerous.
WARNING: Do not use any accessory not ap-
proved for use with this heater.
Surface of heater becomes very hot when running
heater. Keep children and adults away from hot surface to avoid burns or clothing ignition. Heater will
remain hot for a time after shutdown. Allow surface to
cool before touching.
Carefully supervise young children when they are in
the same room with heater.
Make sure grill guard is in place before running
heater.
Keep the appliance area clear and free from combustible materials, gasoline, and other flammable vapors
and liquids.
1.This appliance is only for use with the type of gas indicated on
the rating plate. This appliance is not convertible for use with
other gases.
2.Do not place propane/LP supply tank(s) inside any structure.
Locate propane/LP supply tank(s) outdoors.
3.Do not install 10,000 Btu units in a bathroom.
For more information, visit www.desatech.com
For more information, visit www.desatech.com
110720-01C
SAFETY INFORMATION
UNPACKING
PRODUCT IDENTIFICATION
PRODUCT FEATURES
LOCAL CODES
3
3
SAFETY INFORMATION
Continued
4.If you smell gas
• Shut off gas supply
• Do not try to light any appliance
• Do not touch any electrical switch; do not use any phone in
your building
• Immediately call your gas supplier from a neighbor’s phone.
Follow the gas supplier’s instructions
• If you cannot reach your gas supplier, call the fire department
5.This heater needs fresh, outside air ventilation to run properly.
This heater has an Oxygen Depletion Sensing (ODS) safety
shutoff system. The ODS shuts down the heater if not enough
fresh air is available. See Air for Combustion and Ventilation,
pages 4 through 6.
6.Always run heater with control knob at LOW or HIGH locked
positions (VP10A) or ON position (VP5D). Never set control
knob between locked positions. Poor combustion may result.
7.Keep all air openings in the front and bottom of heater clear and
free of debris. This will insure enough air for proper combustion.
8.If heater shuts off, do not relight until you provide fresh, outside air. If heater keeps shutting off, have it serviced.
9.Do not run heater
• where flammable liquids or vapors are used or stored
• under dusty conditions
10. Before using furniture polish, wax, carpet cleaner, or similar
products, turn heater off. If heated, the vapors from these products may create a white powder residue within burner box or
on adjacent walls or furniture.
11. Do not use heater if any part has been under water. Immediately call a qualified service technician to inspect the room
heater and to replace any part of the control system and any
gas control which has been under water.
12. Turn off heater and let cool before servicing. Only a qualified
service person should service and repair heater.
13. Operating heater above elevations of 4,500 feet could cause
pilot outage.
14. T o prevent performance problems, do not use propane/LP fuel
tank of less than 100 lbs. capacity.
15. Provide adequate clearances around air openings.
UNPACKING
1.Remove heater from carton.
2.Remove all protective packaging applied to heater for shipment.
3.Check heater for any shipping damage. If heater is damaged,
promptly inform dealer where you bought heater.
PRODUCT IDENTIFICATION
Piezo Ignitor
Button
Glass
Panel
Blue Flame Heater
Figure 1 - Vent-Free Gas Heater
Control Knob
Grill
Guard
Front
Panel
Heater
Cabinet
Piezo Ignitor
Button
Infrared Heater
Control Knob
Burners
PRODUCT FEATURES
SAFETY DEVICE
This heater has a pilot with an Oxygen Depletion Sensing (ODS)
safety shutoff system. The ODS/pilot is a required feature for ventfree room heaters. The ODS/pilot shuts off the heater if there is not
enough fresh air.
PIEZO IGNITION SYSTEM
This heater has a piezo ignitor. This system requires no matches,
batteries, or other sources to light heater.
LOCAL CODES
Install and use heater with care. Follow all local codes. In the absence
of local codes, use the latest edition of National Fuel Gas Code ANSIZ223.1/NFPA 54*.
*Available from:
American National Standards Institute, Inc.
1430 Broadway
New York, NY 10018
National Fire Protection Association, Inc.
Batterymarch Park
Quincy, MA 02269
110720-01C
For more information, visit www.desatech.com
For more information, visit www.desatech.com
AIR FOR COMBUSTION AND VENTILATION
4
Providing Adequate Ventilation
Determining Fresh-Air Flow For Heater Location
AIR FOR COMBUSTION AND
VENTILATION
WARNING: This heater shall not be installed in a
confined space or unusually tight construction unless provisions are provided for adequate combustion and ventilation air. Read the following instructions to insure proper fresh air for this and other fuelburning appliances in your home.
Today’s homes are built more energy efficient than ever. New
materials, increased insulation, and new construction methods help
reduce heat loss in homes. Home owners weather strip and caulk
around windows and doors to keep the cold air out and the warm air
in. During heating months, home owners want their homes as
airtight as possible.
While it is good to make your home energy efficient, your home
needs to breathe. Fresh air must enter your home. All fuel-burning
appliances need fresh air for proper combustion and ventilation.
Exhaust fans, fireplaces, clothes dryers, and fuel burning appliances
draw air from the house to operate. You must provide adequate fresh
air for these appliances. This will insure proper venting of vented
fuel-burning appliances.
PROVIDING ADEQUATE VENTILATION
The following are excerpts from National Fuel Gas Code, ANSI
Z223.1/NFPA 54, Section 5.3, Air for Combustion and Ventilation.
All spaces in homes fall into one of the three following ventilation
classifications:
1.Unusually Tight Construction
2.Unconfined Space
3.Confined Space
The information on pages 4 through 6 will help you classify your
space and provide adequate ventilation.
Unusually Tight Construction
The air that leaks around doors and windows may provide enough
fresh air for combustion and ventilation. However, in buildings of
unusually tight construction, you must provide additional fresh air.
Unusually tight construction is defined as construction
where:
a.walls and ceilings e xposed to the outside atmosphere
have a continuous water vapor retarder with a rating
of one perm (6 x 10
openings gasketed or sealed
b. weather stripping has been added on openable win-
dows and doors
-11
kg per pa-sec-m2) or less with
and
and
c. caulking or sealants are applied to areas such as
joints around window and door frames, between sole
plates and floors, between wall-ceiling joints, between
wall panels, at penetrations for plumbing, electrical,
and gas lines, and at other openings.
If your home meets all of the three criteria above, you
must provide additional fresh air. See
From Outdoors
, page 6
.
Ventilation Air
If your home does not meet all of the three criteria above,
proceed to
tion,
Determining Fresh-Air Flow For Heater Loca-
page 5.
Confined and Unconfined Space
The National Fuel Gas Code, ANSI Z223.1/NFPA 54 defines a
confined space as a space whose volume is less than 50 cubic feet
per 1,000 Btu per hour (4.8 m3 per kw) of the aggregate input rating
of all appliances installed in that space and an unconfined space as
a space whose volume is not less than 50 cubic feet per 1,000 Btu per
hour (4.8 m3 per kw) of the aggregate input rating of all appliances
installed in that space. Rooms communicating directly with the
space in which the appliances are installed*, through openings not
furnished with doors, are considered a part of the unconfined space.
* Adjoining rooms are communicating only if there are doorless
passageways or ventilation grills between them.
DETERMINING FRESH-AIR FLOW FOR
HEATER LOCATION
Determining if You Have a Confined or
Unconfined Space
Use this work sheet to determine if you have a confined or unconfined space.
Space: Includes the room in which you will install heater plus any adjoining
rooms with doorless passageways or ventilation grills between the rooms.
1.Determine the volume of the space (length x width x height).
Length x Width x Height =___________ cu. ft. (volume of space)
Example:
height) = 3168 cu. ft. (volume of space)
If additional ventilation to adjoining room is supplied with grills or open-
ings, add the volume of these rooms to the total volume of the space.
2.Multiply the space volume by 20 to determine the maximum Btu/Hr
the space can support.
__________ (volume of space) x 20 = (Maximum Btu/Hr the space
Example:
Btu/Hr the space can support)
Space size 22 ft. (length) x 18 ft. (width) x 8 ft. (ceiling
can support)
2560 cu. ft. (volume of space) x 20 = 51,200 (maximum
For more information, visit www.desatech.com
For more information, visit www.desatech.com
110720-01C
Determining Fresh-Air Flow For Heater Location (Cont.)
AIR FOR COMBUSTION AND VENTILATION
Ventilation Air
5
5
AIR FOR COMBUSTION AND
VENTILATION
Continued
3.Add the Btu/Hr of all fuel burning appliances in the space.
Vent-free heater_____________ Btu/Hr
Gas water heater*_____________ Btu/Hr
Gas furnace_____________ Btu/Hr
Vented gas heater_____________ Btu/Hr
Gas fireplace logs_____________ Btu/Hr
Other gas appliances* + _____________ Btu/Hr
Total = _____________ Btu/Hr
* Do not include direct-vent gas appliances. Direct-vent draws combustion air from the outdoors and vents to the outdoors.
Example:
Gas water heater_____________ Btu/Hr
Vent-free heater+ _____________ Btu/Hr
Total= _____________ Btu/Hr
4.Compare the maximum Btu/Hr the space can support with the actual
amount of Btu/Hr used.
__________________ Btu/Hr (maximum the space can support)
__________________ Btu/Hr (actual amount of Btu/Hr used)
Example:
51,200 Btu/Hr (maximum the space can support)
50,000 Btu/Hr (actual amount of Btu/Hr used)
The space in the above example is a confined space because the actual Btu/
Hr used is more than the maximum Btu/Hr the space can support. You must
provide additional fresh air. Your options are as follows:
A. Rework worksheet, adding the space of an adjoining room. If the ex-
tra space provides an unconfined space, remove door to adjoining
room or add ventilation grills between rooms. See V entilation Air Fr omInside Building.
B. Vent room directly to the outdoors. See Ventilation Air From
Outdoors.
C. Install a lower Btu/Hr heater, if lower Btu/Hr size makes room un-
confined.
If the actual Btu/Hr used is less than the maximum Btu/Hr the space can
support, the space is an unconfined space. You will need no additional fresh
air ventilation.
WARNING: If the area in which the heater may be
operated is smaller than that defined as an unconfined space or if the building is of unusually tight
construction, provide adequate combustion and ventilation air by one of the methods described in the
National Fuel Gas Code, ANSI Z223.1/NFPA 54, Section 5.3
or applicable local codes.
40,000
10,000
50,000
VENTILATION AIR
Ventilation Air From Inside Building
This fresh air would come from an adjoining unconfined space.
When ventilating to an adjoining unconfined space, you must
provide two permanent openings: one within 12" of the ceiling and
one within 12" of the floor on the wall connecting the two spaces
(see options 1 and 2, Figure 2). You can also remove door into
adjoining room (see option 3, Figure 2). Follow the National Fuel
Gas Code, ANSI Z223.1/NFPA 54, Section 5.3, Air for Combustion
and Ventilation for required size of ventilation grills or ducts.
12"
Ventilation Grills
Ventilation
Grills
into Adjoining
Room,
Option 1
Or
Remove
Door into
Adjoining
Room,
Option 3
Figure 2 - Ventilation Air from Inside Building
Ventilation Air From Outdoors
Provide extra fresh air by using ventilation grills or ducts. You must
provide two permanent openings: one within 12" of the ceiling and
one within 12" of the floor. Connect these items directly to the
outdoors or spaces open to the outdoors. These spaces include attics
and crawl spaces. Follow the National Fuel Gas Code, ANSI Z223.1/NFPA 54, Section 5.3, Air for Combustion and Ventilation for
required size of ventilation grills or ducts.
IMPORTANT:
attic if attic has a thermostat-controlled power vent. Heated air
entering the attic will activate the power vent.
Outlet
Air
Do not provide openings for inlet or outlet air into
Outlet
Air
Inlet
Air
Inlet Air
Into Adjoining Room,
12"
Ventilated
Attic
Option 2
Ventilated
Crawl Space
To Attic
To
Crawl
Space
110720-01C
Figure 3 - Ventilation Air from Outdoors
For more information, visit www.desatech.com
For more information, visit www.desatech.com
T
INSTALLATION
6
Check Gas Type
Installation Items
Locating Heater
INSTALLATION
NOTICE: This heater is intended for use as supplemental heat. Use this heater along with your primary
heating system. Do not install this heater as your
primary heat source. If you have a central heating
system, you may run system’s circulating blower
while using heater. This will help circulate the heat
throughout the house. In the event of a power outage,
you can use this heater as your primary heat source.
WARNING: A qualified service person must in-
stall heater. Follow all local codes.
CHECK GAS TYPE
Use only the correct type of gas (natural or propane/LP). If your gas
supply is not the correct gas type, do not install heater. Call dealer
where you bought heater for proper type heater.
INSTALLATION ITEMS
Before installing heater, make sure you have the items listed below.
• for propane/LP gas, external regulator (supplied by installer)
• piping (check local codes)
• sealant (resistant to propane/LP gas)
• equipment shutoff valve *
• ground joint union
• sediment trap
• tee joint
• pipe wrench
• for natural gas, test gauge connection*
* A CSA design-certified equipment shutoff valve with 1/8" NPT
tap is an acceptable alternative to test gauge connection. Purchase
the optional CSA design-certified equipment shutoff valve from
your dealer. See Accessory, page 30.
WARNING: Never install the heater
• in a bathroom (10,000 Btu/hr only. 6,000 Btu/hr models are allowed in a bathroom. Check local codes.)
• in a recreational vehicle
• where curtains, furniture, clothing, or other flam-
mable objects are less than 36 inches from the
front, top, or sides of the heater
• as a fireplace insert
• in high traffic areas
• in windy or drafty areas
CAUTION: This heater creates warm air currents.
These currents move heat to wall surfaces next to
heater. Installing heater next to vinyl or cloth wall
coverings or operating heater where impurities (such
as, but not limited to, tobacco smoke, aromatic
candles, cleaning fluids, oil or kerosene lamps, etc.)
in the air exist, may discolor walls or cause odors.
IMPORTANT:
Vent-free heaters add moisture to the air. Although this is beneficial, installing heater in rooms without enough
ventilation air may cause mildew to form from too much moisture.
See Air for Combustion and Ventilation, pages 4 through 6.
CAUTION: If you install the heater in a home
garage
• heater pilot and burner must be at least 18 inches
above floor
• locate heater where moving vehicle will not hit it
For convenience and efficiency, install heater
• where there is easy access for operation, inspection, and service
• in coldest part of room
CEILING
LOCATING HEATER
This heater is designed to be mounted on a wall.
WARNING: Maintain the minimum clearances
shown in Figure 4. If you can, provide greater clearances from floor, ceiling, and joining wall.
For more information, visit www.desatech.com
For more information, visit www.desatech.com
6" Blueflame
8" Plaque
Minimum
From
Sides Of
Heater
Left
Side
Figure 4 - Mounting Clearances As Viewed From Front of Heater
36"
Minimum
Right
Side
3"
Minimum To
Minimum To Top
Of Carpeting,
Surface Of Carpeting,
Tile Or Other
Combustible Material
110720-01C
INSTALLATION
Continued
Thermostat Sensing Bulb (Thermostat Models Only)
INSTALLATION
Installing Heater To Wall
7
7
THERMOSTAT SENSING BULB (Thermostat
Models Only)
The thermostat sensing bulb is located inside the heater. Do not
move this bulb during installation or operation of the heater.
INSTALLING HEATER TO WALL
Marking Screw Locations
1.Determine where you will locate heater.
WARNING: Maintain minimum clearances shown
in Figure 5. If you can, provide greater clearances
from floor and joining wall.
2.Mark two mounting screw locations on wall (see Figure 5).
3
/4"
Mounting
Screw
Locations
FLOOR
7
1
20
/4"
Minimum To
Maintain 3"
Clearance
From Floor
8 7/8"
Blue Flame
7
/8" Plaque
10
Minimum To
Maintain 6"
Clearance
From Wall
JOINING WALL
Figure 5 - Mounting Screw Locations
4.For thin walls (1/2" or less), insert red key into wall anchor.
Push red key to “pop” open anchor wings (see Figure 7).
IMPORTANT:
Do not hammer key! For thick walls (over 1/2"
thick) or solid walls, do not pop open wings.
5.Tighten two screws until 1/16" space (thickness of penny) is
between screwheads and wall (see Figure 8).
Thin Walls (1/4" to 1/2" thick)
Figure 6 - Folding Anchor
1/16"
Space
Figure 8 - Tightening Anchors
Figure 7 - Popping Open Anchor
Wings For Thin Walls
Thin or
Thick Wall
(thick wall
shown)
Solid
Wall
Placing Heater On Mounting Screws
1.Locate two keyhole slots on back panel of heater (see Figure 9).
2.Place large openings of slots over screwheads. Slide heater
down until screws are in small portion of slots.
Installing Two Mounting Screws
Note:
Wall anchors and mounting screws are in hardware package.
The hardware package is provided with heater.
Attaching to wall stud method
For attaching mounting screw to wall stud
1.Drill hole at marked location using 9/64" drill bit.
2.Insert mounting screw into wall stud.
3.Tighten screw until 1/16" space (thickness of penny) is between screwhead and wall.
Attaching to wall anchor method
Follow instructions below to attach mounting screws to hollow walls
(wall areas between studs) or solid walls (concrete or masonry).
1.Drill holes at marked locations using 5/16" drill bit. For solid
walls (concrete or masonry), drill at least 1 1/4" deep.
2.Fold wall anchor (see Figure 6).
3.Insert wall anchor (wings first) into hole. Tap anchor flush to wall.
For more information, visit www.desatech.com
For more information, visit www.desatech.com
110720-01C
Keyhole Slots
Figure 9 - Location Of Keyhole Slots On Back Panel Of Heater
Removing Front Panel Of Heater
1.Remove two screws near bottom corners of front panel.
2.Lift straight up on grill guard until it stops. Grill guard will slide
up about 1/4".
3.Pull bottom of front panel forward, then down.
Figure 10 - Removing Front Panel Of Heater
INSTALLATION
8
Installing Heater To Wall (Cont.)
Connecting To Gas Supply
INSTALLATION
Continued
Installing Bottom Mounting Screw
1.Locate bottom mounting hole. This hole is near bottom on back
panel of heater (see Figure 11).
2.Mark screw location on wall.
3.Remove heater from wall.
4.If installing bottom mounting screw into hollow or solid wall,
install wall anchor. Follow steps 1 through 5 under Attaching ToW all Anchor Method, page 7. If installing bottom mounting screw
into wall stud, drill hole at marked location using 9/64" drill bit.
5.Replace heater on wall.
6.Insert bottom anchor screw through back panel into bottom
anchor or drilled hole (see Figure 11).
7.Tighten screw until heater is firmly secured to wall. Do not
over tighten.
Note:
Do not replace front panel at this time. Replace front
panel after making gas connections and checking for leaks (see
pages 8 through 10).
Figure 11 - Installing Bottom Mounting Screw
CONNECTING TO GAS SUPPLY
WARNING: This appliance requires a 3/8" NPT
(National Pipe Thread) inlet connection to the pressure regulator.
CAUTION: For propane/LP gas, never connect
heater directly to the propane/LP supply. This heater
requires an external regulator (not supplied). Install
the external regulator between the heater and propane/LP supply.
For propane/LP gas, the installer must supply an external regulator.
The external regulator will reduce incoming gas pressure. You must
reduce incoming gas pressure to between 11 and 14 inches of water.
If you do not reduce incoming gas pressure, heater regulator damage
could occur. Install external regulator with the vent pointing down
as shown in Figure 12. Pointing the vent down protects it from
freezing rain or sleet.
CAUTION: Use only new, black iron or steel pipe.
Internally-tinned copper tubing may be used in certain areas. Check your local codes. Use pipe of large
enough diameter to allow proper gas volume to heater.
If pipe is too small, undue loss of volume will occur.
Installation must include equipment shutoff valve, union, and plugged
1/8" NPT tap. Locate NPT tap within reach for test gauge hook up.
NPT tap must be upstream from heater (see Figure 13, page 9).
IMPORTANT:
location. The equipment shutoff valve is for turning on or shutting
off the gas to the appliance.
Check your building codes for any special requirements for locating
equipment shutoff valve to fireplaces.
Apply pipe joint sealant lightly to male NPT threads. This will
prevent excess sealant from going into pipe. Excess sealant in pipe
could result in clogged heater valves.
WARNING: Use pipe joint sealant that is resistant
to liquid petroleum (LP) gas.
Install an equipment shutoff valve in an accessible
WARNING: A qualified service person must con-
nect heater to gas supply. Follow all local codes.
WARNING: For natural gas, never connect heater to
private (non-utility) gas wells. This gas is commonly
known as wellhead gas.
IMPORTANT
connecting heater to gas line. Gas line pressure must be no greater than
14 inches of water. If gas line pressure is higher, heater regulator
damage could occur.
: For natural gas, check gas line pressure before
For more information, visit www.desatech.com
For more information, visit www.desatech.com
Propane/LP
Supply Tank
Figure 12 - External Regulator With Vent Pointing Down
(propane/LP systems only)
External Regulator
Vent Pointing Down
110720-01C
ON
POSITIO
OF
POSI
INSTALLATION
Continued
We recommend that you install sediment trap in supply line as
shown in Figure 13. Locate sediment trap where it is within reach for
cleaning. Install in piping system between fuel supply and heater.
Locate sediment trap where trapped matter is not likely to freeze. A
sediment trap traps moisture and contaminants. This keeps them
from going into heater controls. If sediment trap is not installed or
is installed wrong, heater may not run properly.
IMPORTANT:
necting it to gas piping and/or fittings. Do not over tighten pipe
connection to regulator. The regulator body could be damaged.
3/8" NPT
Pipe Nipple
Ground
Joint Union
Equipment
Shutoff Valve*
Natural Gas
From Gas Meter
(4" W.C. to 10.5"
W.C. Pressure)
Propane/LP
From External
Regulator
(11" W.C. to 14"
W.C. Pressure)
Figure 13 - Gas Connection
* A CSA design-certified equipment shutoff valve with 1/8" NPT
tap is an acceptable alternative to test gauge connection. Purchase
the optional CSA design-certified equipment shutoff valve from
your dealer. See Accessory, page 30.
CHECKING GAS CONNECTIONS
WARNING: Test all gas piping and connections
for leaks after installing or servicing. Correct all leaks
at once.
Hold pressure regulator with wrench when con-
Pressure
Regulator
Heater
Cabinet
Tee Joint
3"
Minimum
Reducer
Bushing to
1/8" NPT
1/8" NPT
Plug Tap
Tee
Joint
Pipe
Nipple
Cap
Test
Gauge
Connection*
Sediment
Trap
Connecting To Gas Supply (Cont.)
INSTALLATION
Checking Gas Connections
9
9
CAUTION: For propane/LP gas, make sure external regulator has been installed between propane/LP
supply and heater. See guidelines under
to Gas Supply
, page 8.
Connecting
Pressure Testing Gas Supply Piping System
Test Pressures In Excess Of 1/2 PSIG (3.5 kPa)
1.Disconnect appliance with its appliance main gas valve (control
valve) and equipment shutoff valve from gas supply piping system. Pressures in excess of 1/2 psig will damage heater regulator.
2.Cap off open end of gas pipe where equipment shutoff valve
was connected.
3.Pressurize supply piping system by either opening propane/LP
supply tank valve for propane/LP gas or opening main gas valve
located on or near gas meter for natural gas, or using compressed air.
4.Check all joints of gas supply piping system. Apply a noncorrosive leak detection fluid to all joints. Bubbles forming
show a leak.
5.Correct all leaks at once.
6.Reconnect heater and equipment shutoff valve to gas supply.
Check reconnected fittings for leaks.
Test Pressures Equal To or Less Than 1/2 PSIG (3.5 kPa)
1.Close equipment shutoff valve (see Figure 14).
2.Pressurize supply piping system by either opening propane/LP
supply tank valve for propane/LP gas or opening main gas
valve located on or near gas meter for natural gas, or using
compressed air.
Equipment
Shutoff Valve
Figure 14 - Equipment Shutoff Valve
Open
Closed
WARNING: Never use an open flame to check for
a leak. Apply a noncorrosive leak detection fluid to all
joints. Bubbles forming show a leak. Correct all leaks
at once.
For more information, visit www.desatech.com
For more information, visit www.desatech.com
110720-01C
10
INSTALLATION
Checking Gas Connections (Cont.)
OPERATING HEATER (Manual Control Blue Flame Models)
For Your Safety Read Before Lighting
Lighting Instructions
INSTALLATION
Continued
3.Check all joints from gas meter for natural or propane/LP
supply to equipment shutoff valve (see Figure 17 or 18).
Apply a noncorrosive leak detection fluid to all joints. Bubbles
forming show a leak.
4.Correct all leaks at once.
Pressure Testing Heater Gas Connections
1.Open equipment shutoff valve (see Figure 14, page 9).
2.Open main gas valve located on or near gas meter for natural
gas or open propane/LP supply tank valve.
3.Make sure control knob of heater is in the OFF position.
4.Check all joints from equipment shutoff valve to control valve
(see Figures 15 and 16). Apply a noncorrosive leak detection
fluid to all joints. Bubbles forming show a leak.
5.Correct all leaks at once.
6.Light heater (see Operating Heater pages 10 through 14).
Check the rest of the internal joints for leaks.
7.Turn off heater (see To Turn Off Gas to Appliance, pages 11,
12 or 14, depending on your model).
8.Replace front panel.
Control Valve Location
Gas
Meter
Equipment
Shutoff Valve
OPERATING HEATER
MANUAL CONTROL
BLUE FLAME MODELS
FOR YOUR SAFETY READ
BEFORE LIGHTING
WARNING: If you do not follow these instructions
exactly, a fire or explosion may result causing property damage, personal injury or loss of life.
A. This appliance has a pilot which must be lighted by hand.
When lighting the pilot, follow these instructions exactly.
B. BEFORE LIGHTING smell all around the appliance ar ea
for gas. Be sure to smell next to the floor because some gas
is heavier than air and will settle on the floor.
WHAT TO DO IF YOU SMELL GAS
• Do not try to light any appliance.
• Do not touch any electric switch; do not use any phone in
your building.
• Immediately call your gas supplier from a neighbor’s
phone. Follow the gas supplier’s instructions.
• If you cannot reach your gas supplier, call the fire department.
C. Use only your hand to push in or turn the gas control knob.
Never use tools. If the knob will not push in or turn by
hand, don’t try to repair it, call a qualified service technician or gas supplier. Force or attempted repair may result
in a fire or explosion.
D. Do not use this appliance if any part has been under water.
Immediately call a qualified service technician to inspect the
appliance and to replace any part of the control system and
any gas control which has been under water.
Figure 15 - Checking Gas Joints for Natural Gas
Propane/LP
Supply Tank
Figure 16 - Checking Gas Joints for Propane/LP Gas
For more information, visit www.desatech.com
For more information, visit www.desatech.com
Control
Valve Location
Equipment
Shutoff Valve
LIGHTING
INSTRUCTIONS
1.STOP! Read the safety information above.
2.Make sure equipment shutoff valve is fully open.
3.Turn control knob clockwise
4.Wait five (5) minutes to clear out any gas. Then smell for
gas, including near the floor. If you smell gas, STOP! Follow “B” in the safety information, above. If y ou don’t smell
gas, go to the next step.
5.Press in control knob and turn counterclockwise
to the PILOT position. Keep control knob pressed in for
five (5) seconds (see Figure 17, page 11).
Note:
You may be running this heater for the first time
after hooking up to gas supply . If so, the control knob may
need to be pressed in for 30 seconds or more. This will allow air to bleed from the gas system.
• If control knob does not pop up when released, contact a
qualified service person or gas supplier for repairs.
to the OFF position.
Clockwise
C-clockwise
110720-01C
OPERATING HEATER
Continued
OPERATING HEATER (Manual Control Blue Flame Models)
Lighting Instructions (Cont.)
To Turn Off Gas To Appliance
Manual Lighting Procedure
OPERATING HEATER (Manual Control Infrared Models)
For Your Safety Read Before Lighting
11
11
6.With control knob pressed in, push do wn and release ignitor button. This will light pilot. The pilot is attached to the
front of burner. If needed, keep pressing ignitor button until
pilot lights.
Note:
If pilot does not stay lit, refer to Troubleshooting,
pages 16 through 18. Also contact a qualified service person or gas supplier for repairs. Until r epairs are made, light
pilot with match. To light pilot with match, see ManualLighting Procedure.
7.Keep control knob pressed in for 30 seconds after lighting
pilot. After 30 seconds, release control knob.
Note:
If pilot goes out, repeat steps 3 through 7.
8.T urn contr ol knob counterclockwise
C-clockwise
to the HIGH
position. The main burner should light. Set control knob
to any heat level between HIGH and LO W . To turn control
knob from HIGH to a lower setting, press in the control
knob and turn counterclockwise
Note:
Both HIGH and LOW ar e locked positions. You must
C-clockwise
.
press in control knob befor e turning it from these positions.
CAUTION: Do not try to adjust heating levels by
using the equipment shutoff valve.
Ignitor Button
Control Knob
PILOT
OFF
TO TURN OFF GAS
TO APPLIANCE
Shutting Off Heater
1.Tur n control knob clockwise
2.Press in control knob and turn clockwise
OFF position.
Clockwise
to the PILOT position.
Clockwise
to the
Shutting Off Burner Only (pilot stays lit)
Turn control knob clockwise
to the PILOT position.
Clockwise
MANUAL LIGHTING
PROCEDURE
1.Remove front panel (see Figure 10, page 7).
2.Follow steps 1 through 5 under Lighting Instructions, page 10.
3.With control knob pressed in, strik e match. Hold match to
pilot until pilot lights.
4.Keep control knob pressed in for 30 seconds after pilot is
lit. After 30 seconds, release control knob. Follow step 8
under Lighting Instructions.
5.Replace front panel.
MANUAL CONTROL INFRARED MODELS
IGNITOR
Figure 17 - Control Knob In The OFF Position
Figure 18 - Pilot
110720-01C
HIGH
LOW
Thermocouple
Ignitor Electrode
For more information, visit www.desatech.com
For more information, visit www.desatech.com
Pilot Burner
FOR YOUR SAFETY READ
BEFORE LIGHTING
WARNING: If you do not follow these instructions
exactly, a fire or explosion may result causing property damage, personal injury or loss of life.
A. This appliance has a pilot which must be lighted by hand.
When lighting the pilot, follow these instructions exactly.
B. BEFORE LIGHTING smell all around the appliance ar ea
for gas. Be sure to smell next to the floor because some gas
is heavier than air and will settle on the floor.
WHAT TO DO IF YOU SMELL GAS
• Do not try to light any appliance.
• Do not touch any electric switch; do not use any phone in
your building.
• Immediately call your gas supplier from a neighbor’s
phone. Follow the gas supplier’s instructions.
• If you cannot reach your g as supplier, call the fire department.