Desa HFL300 SERIES Installation Instructions Manual

Save for future reference.
For more information, visit www.desatech.com
HFL300 SERIES BRICK LINER KIT
INSTALLATION INSTRUCTIONS
IMPORTANT: Read entire instruction sheet before installing brick liner.
This brick liner accessory is approved for use in Series 4 32" vent-free gas fireplaces and fireboxes. Do not use brick liner ac
-
cessory in any other fireplace models.
The Brick Liner Kit contains the following:
• 1 - Rear Firebrick Panel
• 2 - Side Firebrick Panels
• 2 - Retainer Brackets
• 2 - #10 Screws
Tools required:
• Phillips Screwdriver
• 5/16" Hex Socket Wrench or Nut Driver
If any of these parts are missing or damaged, contact dealer where you purchased this kit. If they cannot supply original replacement parts, either contact your nearest Parts Central or call DESA Heating Products at 1-866-672-6040 for information.
IMPORTANT:
Always handle firebrick panels
with two hands.
WARNING: Turn off, unplug, and let fireplace cool before installing brick liner. Only a qualified service person should service and repair fireplace.
NOTICE: You must remove log base assembly before installing brick liner.
1. To remove screen, lift screen up off the screws in front of fireplace (see Figure 1).
Figure 1 - Removing Fireplace Screen
Screws for Mounting Screen
www.desatech.com
116466-01A
2
2. Remove logs. Remove two screws that attach log base assembly to fireplace. Carefully lift log base assembly and remove from fireplace (see Figure 2).
CAUTION: Do not pick up log base assembly by burners. This may damage burners. Only pick up base by the grate.
Note: Some installations may require the gas
supply line to be disconnected before removing log assembly. If so, call a qualified service per
-
son to disconnect gas supply from fireplace.
WARNING: A qualified ser­vice person must connect and disconnect fireplace to gas sup
-
ply. Follow all local codes.
3. Install rear firebrick panel on back wall first. Standard brick panel has larger bricks at the top while the Herringbone panel has smaller bricks at the top. Rest the bottom edge of firebrick panel on liner flange. Stand firebrick panel straight up against the back of fireplace (see Figure 3). The side brick panels will hold the rear panel in place.
CAUTION: Always handle firebrick panels with two hands. Do not force firebrick panels into place. Excessive force will break firebrick panels.
Note: If your fireplace has a thermodisc plate,
make sure you position the hole in rear fire­brick panel over the thermodisc plate on rear wall of fireplace (see Figure 3). If you cover the thermodisc plate with the firebrick panel, the fan will not run properly.
Figure 2 - Removing Log Base Assembly
from Fireplace
Burners
Two Screws
Log Base Assembly
Liner Flange
Hole
Standard Brick Panel
Rear Firebrick Panel
Thermodisc Plate (not on all models)
Figure 3 - Placing Rear Firebrick Panel
on Flange in Fireplace
Liner Flange
Hole
Herringbone Brick Panel
Rear Firebrick Panel
Thermodisc Plate (not on all models)