IMPORTANT: This b-vent burner system must be installed into approved FMI cast iron stove
bodies, models (P)FC series ONLY. See page 3 of this manual.
QUALIFIED INSTALLER: If you encounter problems during installation of this product, please
contact DESA International’s Technical Service Department at 1-800-337-2564.
WARNING: If the information in this manual is
not followed exactly, a fire or explosion may
result causing property damage, personal injury, or loss of life.
FOR YOUR SAFETY
Do not store or use gasoline or other flammable
vapors and liquids in the vicinity of this or any
other appliance.
FOR YOUR SAFETY
WHAT TO DO IF YOU SMELL GAS
• Do not try to light any appliance.
• Do not touch any electrical switch
• Do not use any phone in your building.
• Immediately call your gas supplier from a
neighbor’s phone. Follow the gas supplier’s
instructions.
• If you cannot reach your gas supplier, call the
fire department.
This appliance may be installed in an aftermarket*, permanently located manufactured
(mobile) home, where not prohibited by state or local codes.
WARNING: Improper installation,
adjustment, alteration, service, or
maintenance can cause injury or
property damage. Refer to this
manual for correct installation and
operational procedures. For assistance or additional information
consult a qualified installer, service agency, or the gas supplier.
— Installation and service must
be performed by a qualified installer, service agency, or the gas
supplier.
— This appliance is only for use
with the type of gas indicated on
the rating plate. This appliance is
not convertible for use with other
gases, unless a certified kit is used.
*Aftermarket: Completion of sale, not for purpose of resale, from the manufacturer.
Save this manual for future reference.
CAST IRON STOVE AND BURNER SYSTEM
SAFETY
INFORMATION
WARNINGS
IMPORTANT: Read this owner’s
manual carefully and completely
before trying to assemble, operate, or service this stove and burner
system. Improper use of this stove
and burner system can cause serious injury or death from burns,
fire, explosions, electrical shock,
and carbon monoxide poisoning.
DANGER: Carbon monoxide
poisoning may lead to death!
This stove with burner system is a vented
product. This stove with burner system will
not produce any gas leakage into your home if
properly installed. This stove must be properly
installed by a qualified service person. The
glass door must be properly seated and sealed.
If this unit is not properly installed by a qualified service person with glass door properly
seated and sealed, gas leakage can occur.
Carbon Monoxide Poisoning: Early signs
of carbon monoxide poisoning resemble the
flu, with headaches, dizziness, or nausea. If
you have these signs, the stove may not have
been installed properly. Get fresh air atonce! Have stove inspected and serviced by
a qualified service person. Some people are
more affected by carbon monoxide than others. These include pregnant women, people
with heart or lung disease or anemia, those
under the influence of alcohol, and those at
high altitudes.
Propane/LP gas and natural gas are both
odorless. An odor-making agent is added to
each of these gases. The odor helps you
detect a gas leak. However, the odor added
to these gases can fade. Gas may be present
even though no odor exists.
Make certain you read and understand all
warnings. Keep this manual for reference. It
is your guide to safe and proper operation of
this stove and burner system.
WARNING: Any change to
this stove or burner system or its
controls can be dangerous.
1.This appliance is only for use with the
type of gas indicated on the rating plate.
This appliance is not convertible for use
with other gases unless a certified kit
is used.
2.For propane/LP burner system, do not
place propane/LP supply tank(s) inside
any structure. Locate propane/LP supply tank(s) outdoors. T o prevent performance problems, do not use propane/LP
fuel tank of less than 100 lbs. capacity.
3.If you smell gas
• shut off gas supply
• do not try to light any appliance
• do not touch any electrical switch; do
not use any phone in your building
• immediately call your gas supplier
from a neighbor’s phone. Follow the
gas supplier’s instructions
• if you cannot reach you gas supplier ,
call the fire department.
4.Never install the stove
• in a recreational vehicle
• where curtains, furniture, clothing, or
other flammable objects are less than
42" from the front, top, or sides of
the fireplace
• in high traffic areas
• in windy or drafty areas
5.This stove reaches high temperatures.
Keep children and adults away from hot
surfaces to avoid burns or clothing ignition. Stove will remain hot for a time
after shutdown. Allow surfaces to cool
before touching.
6.Carefully supervise young children
when they are in the room with stove.
7.Do not modify this burner or stove under any circumstances. Any parts removed for servicing must be replaced
prior to operating stove or burner system.
8.Turn burner system off and let cool
before servicing, installing, or repairing. Only a qualified service person
should install, service, or repair the
stove or burner system. Have burner
system inspected annually by a qualified service person.
9.You must keep control compartments,
burners, and circulating air passages
clean. More frequent cleaning may be
needed due to excessive lint and dust
from carpeting, bedding material, pet
hair, etc. T urn of f the gas valve and pilot light before cleaning stove.
10. Have venting system inspected annually by a qualified service person. If
needed, have venting system cleaned
or repaired. See Cleaning and Mainte-nance, page 22.
11. Keep the area around your stove clear
of combustible materials, gasoline, and
other flammable vapor and liquids. Do
not run burner system where these are
used or stored. Do not place items such
as clothing or decorations on or around
stove.
12. Do not use this stove to cook food or
burn paper or other objects.
13. Never place anything on top of stove.
14. Do not use any solid fuels (wood, coal,
paper, cardboard, etc.) in this stove. Use
only the gas type indicated on burner
system nameplate.
15. This appliance, when installed, must be
electrically grounded in accordance
with local codes or, in the absence of
local codes, with the National Electri-
cal Code, ANS/NFPA 70, or the Canadian Electrical Code, CSA C22.1.
16. Do not obstruct the flow of combustion and ventilation air in any way . Provide adequate clearances around air
openings into the combustion chamber
along with adequate accessibility clearance for servicing and proper operation.
17. Do not install stove directly on carpeting, vinyl tile, or any combustible material other than wood. The stove must set
on a metal or wood panel extending the
full width and depth of the stove.
18. Do not use stove or burner system if
any part has been exposed to or under
water. Immediately call a qualified ser vice person to arrange for replacement
of the unit.
19. Do not operate burner system if an y
log is broken.
20. Do not use a blower insert, heat exchanger insert, or other accessory not
approved for use with this stove.
21. Do not operate burner system with glass
door removed, cracked, or broken.
22. This burner system must be properly
connected to a vent system. This burner
system is equipped with a vent safety
shutoff system.
For more information, visit www.desatech.com
2
107600
OWNER’S MANUAL
PRODUCT
IDENTIFICATION
Cast Iron
Stove Body
Log Set
Front Access Door
Venting
System
ON/OFF
Switch
(Opposite
Side)
Draft Hood
Relief
Opening
Piezo Ignitor
O
H
L
I
OFF
ON
Gas Control Valve
Cast Iron
Stove Body
LOCAL CODES
Install and use stove and burner system with
care. Follow all local codes. In the absence
to local codes, use the current National FuelGas Code ANS Z223.1, also known as
NFPA 54* (USA) or the current CAN/CGA-B149[.1 or .2]Installation Codes (Canada).
*Available from:
American National Standards Institute, Inc.
1430 Broadway
New York, NY 10018
National Fire Protection Association, Inc.
Batterymarch Park
Quincy, MA 02269
PRODUCT
FEATURES
OPERATION
This B-vent freestanding stove with burner
system is clean burning and vents vertically.
Heat is generated by both realistic flames
and glowing embers. When used without
the blower accessory, the stove with burner
system requires no electricity making it
ideal for emergency backup heat.
PIEZO IGNITOR
This burner system has a piezo ignitor. This
system requires no matches, batteries, or
other sources to light burner system.
Burner
Glass Door
Pilot Assy
Blower with
Adjustment
Knob (Optional
Installation)
Rear Cover
Glowing Embers
Grate Assembly
Figure 1 - FMI B-Vent Burner System Shown Installed in Approved FMI Cast Iron Stove
Body Models (P)FC Series Only
107600
Lava Rock
3
Assembly
For more information, visit www.desatech.com
CAST IRON STOVE AND BURNER SYSTEM
PRE-INSTALLATION
PREPARATION
WARNING: A qualified service person must install stove
and burner system. Follow all local codes.
Corner Installation
CAUTION: This stove creates
warm air currents. These currents
move heat to wall surfaces next
to stove. Installing stove next to
vinyl or cloth wall coverings or
operating stove where impurities
(such as tobacco smoke, aromatic candles, cleaning fluids,
oil or kerosene lamps, etc.) in the
air exist, may discolor walls.
LOCATION AND SPACE
REQUIREMENTS
Determine the safest and most efficient location for your FMI B-vent freestanding stove.
Make sure that rafters and wall studs are not
in the way of the venting system. Choose a
location where the heat output is not affected
by drafts, air conditioning ducts, windows, or
doors. Figure 2 shows some common locations. Read all venting information in this
manual. Be aware of all restrictions and precautions before deciding the exact location
for your stove.
When deciding the location of your stove,
follow these rules:
1.Do not connect this stove and burner
system to a chimney flue serving a
separate solid-fuel burning fireplace or
appliance.
2.Due to high temperatures, do not locate this stove in high traffic areas or
near furniture or draperies.
3.Proper clearances must be maintained,
see Figures 3 and 4.
4.This stove is a freestanding unit designed to set directly on the floor. If
your stove is to be installed directly on
carpeting, vinyl tile, or any combustible
material other than wood, it must be
installed on a metal or wood panel extending the full width and depth of the
stove. See Figure 5.
On Wall with Vertical
Termination Through Ceiling
Figure 2 - Common Freestanding Stove Locations
Ceiling
42"
6
"
36"
from
Front
Floor
Figure 3 - Minimum Clearances for Standard Installation
4"
Figure 4 - Minimum Clearance for Corner
Installation
29"
4"
from
Back
Wall
1
19
4"
/2"
Figure 5 - Freestanding Stove with Burner
System Bottom Dimensions
26"
Front
Front
4
"
For more information, visit www.desatech.com
4
107600
CAST IRON STOVE
OWNER’S MANUAL
AND B-VENT
BURNER SYSTEM
ASSEMBLY
STOVE BODY ASSEMBLY
1.Lift off corrugated box enclosing stove
body crating.
2.Remove all screws fastening the wood
frame enclosure. Spread wood frame open
and lift away from plastic-bagged stove
body. The bottom pieces of pallet wood
will remain bolted to the stove body.
3.Remove plastic bag from stove body.
4.Remove back panel from stove and discard (see Figure 6). Use an adjustable
wrench or a 10 mm socket. Remove six
(6) bolts and washers. Keep bolts and
washers to attach rear cover.
5.Remove all contents from inside stove
cavity. Contents include:
(1) - Stove bottom (Discard - Not used
with this application)
(4) - Legs with leg leveler bolts
(1) - Bottom door
(3) - Top grates
(1) - Hardware kit bag with fasteners
6.Carefully lay stove body on back to attach bottom components to stove body
(see Figure 7). Rest stove on drop cloth
or blanket to avoid scratching stove edges.
7.Remove remaining pallet wood attached to bottom of stove body (see
Figure 8). Use an adjustable wrench to
remove bolts.
8.Fasten each leg to stove with four (4)
M8 x 1.25 - 20mm bolts. Use a flat
washer and lock washer with each bolt.
Tighten bolts into threaded holes on
stove body (see Figure 9 and Figure 10,
page 6). Use an adjustable wrench or a
12mm socket.
Bolt
Back
Stove
Panel
Figure 6 - Removing Back Panel
Front of
Stove Unit
Drop
Cloth/
Blanket
Figure 7 - Laying Down Stove On Side
Pallet Wood
Figure 8 - Removing Pallet Wood From The Bottom of The Stove
Door Hinge
Step Bolt Hole
Product
Identification
Label
Top of Stove Unit
Bolt
Leg
Hole
Front of Stove Unit
Pallet
Wood
Bolted to
Bottom of
Stove Body
Front
Door Catch Bolt With
Adjustable Hex Nuts Hole
Front
Pallet Wood
Bottom Of
Stove Unit
Leg
Hole
Stove
Unit
107600
Bottom Of
Stove Unit
Leg Hole
Figure 9 - Locating Threaded Holes for Legs and Door Attachment
5
For more information, visit www.desatech.com
Continued
CAST IRON STOVE AND BURNER SYSTEM
CAST IRON STOVE
AND B-VENT
BURNER SYSTEM
ASSEMBLY
Continued
9.Attach stove door by inserting step bolt
through door hinge pivot hole and into
threaded hole in stove body (see Figure 9, page 5 and Figure 11). Use an
adjustable wrench or a 12mm socket
to fasten step bolt. Tighten step bolt
until snug. Make sure door moves
freely.
Washers
Bolt
Figure 10 - Attaching Stove Legs
Stove Door
Panel
Door Hinge
Step
Bolt
Bolt
Shoulder
Figure 11 - Attaching Lower Stove Door
Panel
Bottom Of
Stove Unit
Leg
Threaded
Hole
10. Install door catch bolt (M8 x 1.25-55mm
with two M8 hex nuts) into threaded
hole on stove body (see Figure 9, page
5). Use an adjustable wrench or a 12mm
socket. The catch bolt has two hex nuts
attached to it (see Figure 12). The top
nut is a bolt stop and the bottom nut is
for door leveling adjustment.
11. Check general catch bolt alignment
with door claw. Make final adjustment
and door leveling after stove is in normal standing position.
12. Carefully lift stove back up on its four
attached legs.
13. Remove 2 bolts from bottom of stove
and one from the top of the stove to
remove the front panel assembly (see
Figure 13).
14. Lay the front panel assembly face down
on a protected surface. Remove the two
screws that hold the front plate onto the
front surround plate (see Figure 14).
Save these screws.
15. Remove the seven screws and washers
that hold the screen onto the front surround plate. Discard these screws,
washers, and screen. They are for ventfree use only (see Figure 14).
16. Replace the two screws from step 14
to reassemble the front plate and the
front surround plate. Set this assembly
aside until stove heater has been installed, logs have been placed inside of
heater, and glass door to heater insert
has been replaced.
17. Remove the two screws that secure the
metal plate located across the front section at the top of the stove body (see Figure 15). Discard these screws and metal
plate. They are for vent-free use only.
Bolt
Stop
Adjusting
Door
Claw
Door
Figure 12 - Catch Bolt and Door Claw
Orientation
Nut
Catch
Bolt
Stove
Body
Front
Assembly
Figure 13 - Removing Front Assembly
Front
Surround
Plate
Screw with
Washer
Screen
Front Plate
Figure 14 - Removing Screen from Front
Assembly
Screw
Metal
Plate
Figure 15 - Removing Metal Plate from
Stove Body
Bolt
Screws
Stove Body
For more information, visit www.desatech.com
6
107600
OWNER’S MANUAL
CAST IRON STOVE
AND B-VENT
BURNER SYSTEM
ASSEMBLY
Continued
INSTALLING B-VENT
BURNER SYSTEM INTO
STOVE BODY
1.Carefully lift burner system and place
into stove body from the rear of stove
(see Figure 16).
2.Place gasket on top of burner system
and align over venting hole (see Figure 17). (An extra gasket is supplied
with the burner system and should be
kept with the owner’s manual.)
3.Place 4" connector plate over gasket
and align holes. Secure with hex screws
provided (see Figure 17).
IMPORTANT:
must not be installed until after burner system has been inserted into stove body.
4.Place the left and right grate top into
top of stove body. Discard center grate
top and replace with center top grate
provided with burner system.
Gasket and connecting plate
Center Top Grate
(Included with
Burner System)
Hex Screw
Left Top Grate
Burner
System in
4" Connector Plate
Gasket
Right Top
Grate
Stove Body
Figure 17 - Installing Gasket, Connector Plate, and Top Grates
Cast Iron
Stove Body
Burner
System
O
L
H
I
P
I
OFF
L
O
ON
T
Figure 16 - Installing Burner System into Cast Iron Stove Body
107600
Continued
7
For more information, visit www.desatech.com
CAST IRON STOVE AND BURNER SYSTEM
CAST IRON STOVE
AND B-VENT
BURNER SYSTEM
ASSEMBLY
Continued
INSTALLING OPTIONAL
BLOWER ACCESSORY
NOTICE: If installing blower in an
existing stove burner system with
gas connections, shut off gas supply and disconnect burner system from gas supply. Contact a
qualified service person to do this.
1.Remove 4 hex bolts securing rear cover
to back of stove body (see Figure 18).
2.Separate bottom cover from rear cover
by loosening the 8 mounting screws
(see Figure 18).
3.Align the holes in the top mounting tabs
of blower with the holes in wall of rear
cover. Using the 4 screws provided,
mount blower and tighten screws securely (see Figure 19).
4.Attach thermal switch and bracket to
inside rear cover wall with two hex head
screws provided as shown. After secur ing bracket to rear cover, carefully bend
along existing bend line on bracket to
almost a 90° angle (see Figure 19). This
will allow thermal switch to be positioned against stove rear wall and sense
temperature when in operating mode.
5.Place speed control on left inside of rear
cover and push the plastic control shaft
through opening (see Figure 19).
6.While supporting speed control, secure
control shaft with lock nut by pushing and
turning lock nut with pliers clockwise
until tight against the side of rear cover.
Place control knob provided onto shaft.
7.Place the green ground wire between the
bottom hole on the blower assembly and
the hex screw and tighten (see Figure 20,
page 9).
8.Connect the blue wire to the blower assembly and one side of the thermal
switch (see Figure 20, page 9).
9.Connect the black wire to the other side
of the thermal switch (see Figure 20,
page 9).
10. Connect the white wire to the other terminal on the blower motor assembly
(see Figure 20, page 9). Make sure the
thermal switch has been properly installed to fit against back of burner system after the rear cover assembly has
been reinstalled.
11. Make sure all wire connections to terminals on blower motor and thermal switch
are securely attached and that the screw
retaining the green ground wire is tight.
12. Check to make sure that the power cord
is completely clear of the blower wheel
and that there are no foreign objects in
blower wheel.
WARNING: Never touch the
blower wheel while in operation.
13. Peel of f the backing paper and stick the
supplied wiring diagram decal on the
inside of rear cover as shown (see Figure 20, page 9).
14. Connect or reconnect gas supply following instructions in Connecting
Stove and Burner System to Gas Supply, page 14.
Hex Bolts
Stove Body
Bottom Cover
Figure 18 - Removing Rear Cover and Bottom Cover from Stove Body
WARNING: A qualified installer or service person must
connect burner system to gas
supply. Follow all local codes.
15. Reattach bottom cover to rear cover
with 8 screws removed in step 2 on
page 8 (see Figure 18, page 8). Make
sure that you don’t pinch any wires
during reassembly.
WARNING: Failure to position
the parts in accordance with supplied diagrams or failure to use
only parts specifically approved
with this heater may result in damage or personal injury.
Power Cord
Speed
Control
Box
Black
Wire
Thermal
Switch
Screw
Green Ground Wire
Figure 20 - Blower Wiring Layout
107600
(Route Through
Plastic Bushing in
Bottom Cover When
Assembled)
White
WireBlue Wire
Wiring Diagram Decal
INSTALLING REAR COVER
1.Place rear cover behind stove body.
Rear cover will rest on the bottom ledge
of the stove body.
2. Place wire harness from ON/OFF
switch under the cast of stove body.
3.Using bolts provided, attach rear cover
to back of stove body. See Figure 21.
IMPORTANT:
securely in place before venting pipes
are installed.
4.Open lower door panel. The valve is
attached to the underside of the burner
system assembly.
5.Connect one terminal of the wire from
ON/OFF switch to the THTP terminal
on the valve. Connect remaining wire
terminal to the TH terminal on the
valve. Make sure that the wire terminals are in the positions on the unit as
pictured in Figure 22. If wires are not
connected as shown, the ON/OFF
switch will not work.
WARNING: Read all instructions completely and thoroughly
before attempting installation. Failure to do so could result in serious
injury, property damage, or loss of
life. Operation of improperly installed and maintained venting system could result in serious injury,
property damage, or loss of life.
NOTICE: Failure to follow these
instructions will void the warranty.
INSTALLATION PRECAUTIONS
Consult local building codes before beginning the installation. Only a qualified service person should install venting system.
The installer must follow these safety rules:
• Wear gloves and safety glasses for
protection
• Use extreme caution when using ladders
or when on roof tops
• Be aware of electrical wiring locations
in walls and ceilings
The following actions will void the warranty on your venting system:
• Installation of any damaged venting
component
• Unauthorized modification of the venting system
• Installation of any component part not
manufactured or approved by DESA
International
• Installation other than as instructed by
these instructions
Your burner system is approved for use with
any listed gas vent. A listed gas vent is a factory
made and listed system designed, and installed
exclusively for removing products of combustion, excess air, and dilution air resulting from
burning fuel gas. Metal vents, the most common type of vent, employ double wall construction enclosing an insulating air space.
This air space both helps keep flue gases warm
and reduce heat transferred to nearby combustibles. This appliance is equipped with a safety
control system designed to protect against
improper venting of combustion products.
Continued
CAST IRON STOVE AND BURNER SYSTEM
VENTING
INSTALLATION
Continued
It is very important that the venting system
maintain its balance between the combustion air intake and the flue gas exhaust.
Certain limitations apply to vent configurations and must be strictly followed.
WARNING: This gas stove with
burner system and vent assembly
must be vented directly to the outside. The venting system must
NEVER be attached to a chimney
serving a separate solid fuel burning appliance.
TYPE B-VENT INSTALLATION
(Listed B-0 or Greater)
Before beginning installation be sure that the
overall height and gas vent size conform to
building code requirements. Gas vents extending through pitched roofs can extend a
minimum height of at least 600 mm (2')
higher than any obstruction within 3m (10').
Gas vents extending through flat roofs are
required to extend at least 600 mm (2') above
the roof and at least 600 mm (2') higher than
any portion of the building or adjoining building within 3m (10') of the gas vent.
• Venting instruction contained in this
manual may or may not apply to your
area. Consult your local authority for requirement in your area.
• Where the gas vent extends through accessible spaces, it should be enclosed to
avoid personal contact and damage. Enclosure walls should have a fire rating
equal to or greater than the floors through
which the gas vent passes except in single
or two-family dwellings.
• Situate the gas vent in the structure so
that it can be installed without cutting
joists, sills, plates, or major load bearing
partitions or members. It is also important to locate the base of the gas vent as
near as possible to the heating appliance.
• This heater must be properly connected to
a venting system. This heater is equipped
with a vent safety shutoff system.
• Use only vents labeled "FOR EXTERIOR USE" above the roofline.
• Consult the authority having jurisdiction to select the correct gas vent diameter. Avoid using a larger than necessary diameter.
Round Top
Storm Collar
Flashing
Firestop
Spacer
Enclosure
Wall
Gas Vent
Length
Support
Plate
Adjustable
Length
Figure 23 - Typical B-Vent Installation
Keep Electrical
Wires and Building
Insulation Away
from Gas Vent and
Out of the Required
Air Space
Roof
Support
25mm (1")
Clearance to
Combustible
Material
25mm (1")
Clearance to
Combustibles
INSTALLATION OF LISTED
B-1 VENT
WARNING: Installation should
only be made by qualified persons who are familiar with the
safety procedures required for
the installation of the product,
who are equipped with the proper
tools and testing instruments,
and who have achieved proper
certification of licensing. Installations made by unqualified persons can result in the risk of injury or electrical shock which can
be serious or even fatal.
Figure 24 and Figures 25 and 26, page 11,
show other options for the gas vent. When
venting through a side wall your vent pipe
must have the proper temperature rating
(see Figure 26, page 11). Manufacturer’s
clearances must also be maintained. Consult the authority having jurisdiction in your
area regarding venting through side wall.
Figure 24 - Vertical Venting Through
Ceiling Using Two 90
°
Elbows
For more information, visit www.desatech.com
10