Remote-Ready and Variable Manually-Controlled Models Also Design-Certified As Vented
Decorative Appliances
FLAME-MAX® Vintage
Oak Log Design
I
H
F
F
L
O
O
Pi
lo
t
FLAME-MAX® Golden
Oak Log Design
18", 24" and 30" Variable
Manually-Controlled Models
WARNING: If the information in this manual
is not followed exactly, a fire or explosion
may result causing property damage, personal injury, or loss of life.
— Do not store or use gasoline or other
flammable vapors and liquids in the vicinity
of this or any other appliance.
— WHAT TO DO IF YOU SMELL GAS
• Do not try to light any appliance.
• Do not touch any electrical switch; do not
use any phone in your building.
• Immediately call your gas supplier from a
neighbor’s phone. Follow the gas
supplier’s instructions.
• If you cannot reach your gas supplier, call
the fire department.
— Installation and service must be performed
by a qualified installer, service agency, or
the gas supplier.
18", 24" and 36" Variable Manually-Controlled Models
18" and 24" Thermostat-Controlled Models
18", 24" and 36" Remote-Ready Models
WARNING: Improper installation, adjustment, alteration, service, or maintenance
can cause injury or property damage. Refer to this manual for correct installation
and operational procedures. For assistance or additional information consult a
qualified installer, service agency, or the
gas supplier.
WARNING: This appliance is for installation only in a solid-fuel burning masonry
or UL127 factory-built fireplace, or in an
approved ventless firebox. It is designcertified for these installations in accordance with ANSI Z21.11.2. Exception: Do
not install this appliance in a factory-built
fireplace that includes instructions stating it has not been tested or should not be
used with unvented gas logs.
WARNING: This is an unvented gas-fired heater. It uses air (oxygen) from the room in which
it is installed. Provisions for adequate combustion and ventilation air must be provided. Refer
to
Air for Combustion and Ventilation
section on page 4 of this manual.
This appliance may be installed in an aftermarket,* permanently located,
manufactured (mobile) home, where not prohibited by local codes.
This appliance is only for use with the type of gas indicated on the rating
plate. This appliance is not convertible for use with other gases.
* Aftermarket: Completion of sale, not for purpose of resale, from the manufacturer
Save this manual for future reference.
Save this manual for future reference.
TABLE OF CONTENTS
SAFETY INFORMATION
2
TABLE OF CONTENTS
SAFETY INFORMATION ...................................................................2
CLEANING AND MAINTENANCE ...................................................24
SAFETY INFORMATION
WARNINGS
IMPORTANT: Read this owner’s manual carefully and
completely before trying to assemble, operate, or service this heater. Improper use of this heater can cause
serious injury or death from burns, fire, explosion,
electrical shock, and carbon monoxide poisoning.
DANGER: Carbon monoxide poisoning may lead
to death!
Carbon Monoxide Poisoning: Early signs of carbon monoxide
poisoning resemble the flu, with headaches, dizziness, or nausea.
If you have these signs, the heater may not be working properly.
Get fresh air at once! Have heater serviced. Some people are
more affected by carbon monoxide than others. These include
pregnant women, people with heart or lung disease or anemia,
those under the influence of alcohol, and those at high altitudes.
Natural and Propane/LP Gas: Natural and propane/LP gases are
odorless. An odor-making agent is added to the gas. The odor
helps you detect a gas leak. However, the odor added to the gas can
fade. Gas may be present even though no odor exists.
Make certain you read and understand all warnings. Keep this
manual for reference. It is your guide to safe and proper operation
of this heater.
WARNING: Any change to this heater or its controls
can be dangerous.
WARNING: Do not use a blower insert, heat
exchanger insert, or other accessory not approved
for use with this heater.
WARRANTY INFORMATION............................................ Back Cover
WARNING: Do not allow fans to blow directly into
the fireplace. Avoid any drafts that alter burner flame
patterns. Ceiling fans can create drafts that alter
burner flame patterns. Altered burner patterns can
cause sooting.
Due to high temperatures, the appliance should be
located out of traffic and away from furniture and
draperies.
Do not place clothing or other flammable material on
or near the appliance. Never place any objects on
the heater.
Heater base assembly becomes very hot when running heater. Keep children and adults away from hot
surface to avoid burns or clothing ignition. Heater
will remain hot for a time after shutdown. Allow
surface to cool before touching.
Carefully supervise young children when they are in
the room with heater. When using the hand-held
remote accessory (Remote-Ready Models Only), keep
selector switch in the OFF position to prevent children from turning on burners with remote.
You must operate this heater with a fireplace screen
in place. Make sure fireplace screen is closed before
running heater.
Keep the appliance area clear and free from combustible materials, gasoline, and other flammable vapors
and liquids.
For more information, visit www.desatech.com
For more information, visit www.desatech.com
110399-01A
SAFETY INFORMATION
Continued
SAFETY INFORMATION
3
3
1.This appliance is only for use with the type of gas indicated on
the rating plate. This appliance is not convertible for use with
other gases.
2.Do not place propane/LP supply tank(s) inside any structure. Locate propane/LP supply tank(s) outdoors (propane/LP units only).
4.If you smell gas
• shut off gas supply
• do not try to light any appliance
• do not touch any electrical switch; do not use any phone in
your building
• immediately call your gas supplier from a neighbor’s phone.
Follow the gas supplier’s instructions
• if you cannot reach your gas supplier, call the fire department
4.This heater shall not be installed in a bedroom or bathroom,
unless installed as a vented appliance. See Installing DamperClamp Accessory for Vented Operation, page 11 (RemoteReady and Variable Manually-Controlled Models Only).
5.Before installing in a solid fuel burning fireplace, the chimney
flue and firebox must be cleaned of soot, creosote, ashes and
loose paint by a qualified chimney cleaner. Creosote will ignite if highly heated. Inspect chimney flue for damage. If damaged, repair flue damper before operating heater.
6.If fireplace has glass doors, never operate this heater with glass
doors closed. If you operate heater with doors closed, heat
buildup inside fireplace will cause glass to burst. Also if fireplace opening has vents at the bottom, you must open the vents
before operating heater.
7.To prevent the creation of soot, follow the instructions in Clean-ing and Maintenance, page 24.
8.Before using furniture polish, wax, carpet cleaner, or similar
products, turn heater off. If heated, the vapors from these products may create a white powder residue within burner box or
on adjacent walls and furniture.
9.This heater needs fresh, outside air ventilation to run properly .
This heater has an Oxygen Depletion Sensing (ODS) safety
shutoff system. The ODS shuts down the heater if enough fresh
air is not available. See Air for Combustion and Ventilation,
pages 5 through 7. If heater keeps shutting off, see Trouble-shooting, pages 25 through 27.
10. Do not run heater
• where flammable liquids or vapors are used or stored
• under dusty conditions
11. Do not use this heater to cook food or burn paper or other
objects.
12. Do not use heater if any part has been exposed to or under
water. Immediately call a qualified service technician to inspect the room heater and to replace any part of the control
system and any gas control which has been under water.
13. Do not operate heater if any log is broken. Do not operate
heater if a log is chipped (dime-sized or larger).
14. Turn heater off and let cool before servicing, installing, or repairing. Make sure the selector switch is in the OFF position
(Remote-Ready Models Only). Only a qualified service person should install, service, or repair heater.
15. Make sure the selector switch is in the OFF position when you
are away from home for long periods of time (Remote-Ready
Models Only).
16. Operating heater above elevations of 4,500 feet may cause pilot outage.
17. T o prevent performance problems, do not use propane/LP fuel
tank of less than 100 lb. capacity (propane/LP units only).
18. Provide adequate clearances around air openings.
110399-01A
For more information, visit www.desatech.com
For more information, visit www.desatech.com
PRODUCT IDENTIFICATION
OPTIONAL REMOTE CONTROL ACCESSORIES
4
LOCAL CODES
UNPACKING
PRODUCT IDENTIFICATION
Flame-Max® Golden Oak Logs
Five Piece Log Set
(One-Piece Log Set
for 36" Models)
Piezo Ignitor
Burner Assembly
Control Knob
Five Piece Log Set
(One-Piece Log Set
for 36" Models)
Optional
Remote
Control
Optional Selector Switch
Flame Adjustment Knob
C
O
O
L
A
U
T
O
O
N
O
F
F
W
A
R
M
E
R
T
E
M
E
P
R
Piezo
Ignitor
Base Assembly
Control Knob
OPTIONAL REMOTE
CONTROL ACCESSORIES
There are four optional remote controls that can be purchased
separately for Remote-Ready Models Only:
• wall switch• hand-held ON/OFF remote
• wall thermostat• hand-held thermostat remote.
See Accessories, page 31.
The wall thermostat or hand-held thermostat may not be used where
vented decorative listing is required.
LOCAL CODES
Install and use heater with care. Follow all local codes. In the
absence of local codes, use the latest edition of The National FuelGas Code ANSI Z223.1/NFPA 54*.
*Available from:
American National Standards Institute, Inc.
1430 Broadway
New York, NY 10018
National Fire Protection Association, Inc.
Batterymarch Park
Quincy, MA 02269
Note:
Where listed vented decorative logs are required, thermostat
operation is not permitted.
UNPACKING
Flame-Max® Vintage Oak Logs
Burner
Piezo Ignitor
Burner Assembly
Control Knob
Figure 1 - Product Identification
For more information, visit www.desatech.com
For more information, visit www.desatech.com
Two Piece
Log Set
CAUTION: Do not remove the data plates from the
grate assembly. The data plates contain important
warranty and safety information.
1.Remove logs and heater base assembly from carton.
Note:
Do
not pick up heater base assembly by burners. This could damage heater. Always handle base assembly by grate.
2.Remove all protective packaging applied to logs and heater
for shipment.
3.Check all items for any shipping damage. If damaged, promptly
inform dealer where you bought heater.
110399-01A
PRODUCT FEATURES
PRODUCT FEATURES
AIR FOR COMBUSTION AND VENTILATION
Providing Adequate Ventilation
5
5
OPERATION
This heater is clean burning. It requires no outside venting. There is
no heat loss out a vent or up a chimney. Heat is generated by both
realistic flames and glowing coals. This heater is designed for ventfree operation with flue damper closed. It has been tested and
approved to ANSI Z21.11.2 standard for unvented heaters. State and
local codes in some areas prohibit the use of vent-free heaters. This
heater may also be operated as a vented decorative (ANSI Z21.60)
product by opening the flue damper (Non-Thermostat Models Only).
SAFETY DEVICE
This heater has a pilot with an Oxygen Depletion Sensing (ODS)
safety shutoff system. The ODS/pilot is a required feature for ventfree room heaters. The ODS/pilot shuts off the heater if there is not
enough fresh air.
PIEZO IGNITION SYSTEM
This heater has a piezo ignitor. This system requires no matches,
batteries, or other sources to light heater.
AIR FOR COMBUSTION AND
VENTILATION
WARNING: This heater shall not be installed in a
confined space or unusually tight construction unless provisions are provided for adequate combustion and ventilation air. Read the following instructions to insure proper fresh air for this and other
fuel-burning appliances in your home.
Today’s homes are built more energy efficient than ever. New materials, increased insulation, and new construction methods help reduce
heat loss in homes. Home owners weather strip and caulk around
windows and doors to keep the cold air out and the warm air in. During
heating months, home owners want their homes as airtight as possible.
While it is good to make your home energy efficient, your home
needs to breathe. Fresh air must enter your home. All fuel-burning
appliances need fresh air for proper combustion and ventilation.
Exhaust fans, fireplaces, clothes dryers, and fuel burning appliances
draw air from the house to operate. You must provide adequate fresh
air for these appliances. This will insure proper venting of vented
fuel-burning appliances.
PROVIDING ADEQUATE VENTILATION
The following are excerpts from National Fuel Gas Code, ANSI
Z223.1/NFPA 54, Section 5.3, Air for Combustion and Ventilation.
All spaces in homes fall into one of the three following ventilation
classifications:
1.Unusually Tight Construction
2.Unconfined Space
3.Confined Space
The information on pages 5 through 7 will help you classify your
space and provide adequate ventilation.
Unusually Tight Construction
The air that leaks around doors and windows may provide enough
fresh air for combustion and ventilation. However, in buildings of
unusually tight construction, you must provide additional fresh air.
Unusually tight construction is defined as construction
where:
a.walls and ceilings e xposed to the outside atmosphere
have a continuous water vapor retar der with a rating
of one perm (6 x 10
openings gasketed or sealed
b. weather stripping has been added on openable win-
dows and doors
c. caulking or sealants are applied to areas such as
joints around window and door frames, between sole
plates and floors, between wall-ceiling joints, between
wall panels, at penetrations for plumbing, electrical,
and gas lines, and at other openings.
If your home meets all of the three criteria above,
you must pro vide additional fresh air . See
Air From Outdoors
If your home does not meet all of the three criteria above,
proceed to
tion,
Determining Fresh-Air Flow For Heater Loca-
page 6.
Confined and Unconfined Space
The National Fuel Gas Code, ANSI Z223.1/NFPA 54 defines a
confined space as a space whose volume is less than 50 cubic feet
per 1,000 Btu per hour (4.8 m3 per kw) of the aggregate input rating
of all appliances installed in that space and an unconfined space as
a space whose volume is not less than 50 cubic feet per 1,000 Btu per
hour (4.8 m3 per kw) of the aggregate input rating of all appliances
installed in that space. Rooms communicating directly with the
space in which the appliances are installed*, through openings not
furnished with doors, are considered a part of the unconfined space.
* Adjoining rooms are communicating only if there are doorless
passageways or ventilation grills between them.
-11
kg per pa-sec-m2) or less with
and
and
Ventilation
, page 7
.
110399-01A
For more information, visit www.desatech.com
For more information, visit www.desatech.com
AIR FOR COMBUSTION AND VENTILATION
6
Determining Fresh-Air Flow for Heater Location
AIR FOR COMBUSTION AND
VENTILATION
Continued
DETERMINING FRESH-AIR FLOW FOR
HEATER LOCATION
Determining if You Have a Confined or
Unconfined Space
Use this work sheet to determine if you have a confined or unconfined space.
Space: Includes the room in which you will install heater plus any adjoining
rooms with doorless passageways or ventilation grills between the rooms.
1.Determine the volume of the space (length x width x height).
Length x Width x Height =___________ cu. ft. (volume of space)
Example:
height) = 2560 cu. ft. (volume of space)
If additional ventilation to adjoining room is supplied with grills or open-
ings, add the volume of these rooms to the total volume of the space.
2.Multiply the space volume by 20 to determine the maximum Btu/Hr
the space can support.
__________ (volume of space) x 20 = (Maximum Btu/Hr the space
Example:
Btu/Hr the space can support)
3.Add the Btu/Hr of all fuel burning appliances in the space.
* Do not include direct-vent gas appliances. Direct-vent draws combustion air from the outdoors and vents to the outdoors.
4.Compare the maximum Btu/Hr the space can support with the actual
amount of Btu/Hr used.
__________________ Btu/Hr (maximum the space can support)
__________________ Btu/Hr (actual amount of Btu/Hr used)
Example:
Space size 20 ft. (length) x 16 ft. (width) x 8 ft. (ceiling
can support)
2560 cu. ft. (volume of space) x 20 = 51,200 (maximum
Vent-free heater_____________ Btu/Hr
Gas water heater*_____________ Btu/Hr
Gas furnace_____________ Btu/Hr
Vented gas heater_____________ Btu/Hr
Gas fireplace logs_____________ Btu/Hr
Other gas appliances* + _____________ Btu/Hr
Total = _____________ Btu/Hr
Example:
Gas water heater_____________ Btu/Hr
Vent-free heater+ _____________ Btu/Hr
Total= _____________ Btu/Hr
51,200 Btu/Hr (maximum the space can support)
73,000 Btu/Hr (actual amount of Btu/Hr used)
40,000
33,000
73,000
The space in the above example is a confined space because the actual Btu/
Hr used is more than the maximum Btu/Hr the space can support. You must
provide additional fresh air. Your options are as follows:
A. Rework worksheet, adding the space of an adjoining room. If the ex-
tra space provides an unconfined space, remove door to adjoining
room or add ventilation grills between rooms. See V entilation Air Fr omInside Building, page 7.
B. Vent room directly to the outdoors. See Ventilation Air From Out-
doors, page 7.
C.Install a lower Btu/Hr heater, if lower Btu/Hr size makes room unconfined.
If the actual Btu/Hr used is less than the maximum Btu/Hr the space can support,
the space is an unconfined space. You will need no additional fresh air ventilation.
WARNING: If the area in which the heater may be
operated is smaller than that defined as an unconfined space or if the building is of unusually tight
construction, provide adequate combustion and ventilation air by one of the methods described in the
National Fuel Gas Code, ANSI Z223.1/NFPA 54 Section 5.3
or applicable local codes
.
For more information, visit www.desatech.com
For more information, visit www.desatech.com
110399-01A
AIR FOR COMBUSTION AND
VENTILATION
Continued
VENTILATION AIR
AIR FOR COMBUSTION AND VENTILATION
Ventilation Air
7
7
Ventilation Air From Inside Building
This fresh air would come from an adjoining unconfined space.
When ventilating to an adjoining unconfined space, you must
provide two permanent openings: one within 12" of the ceiling and
one within 12" of the floor on the wall connecting the two spaces
(see options 1 and 2, Figure 2). You can also remove door into
adjoining room (see option 3, Figure 2). Follow the National Fuel
Gas Code, ANSI Z223.1/NFPA 54, Section 5.3, Air for Combustion
and Ventilation for required size of ventilation grills or ducts.
Ventilation Air From Outdoors
Provide extra fresh air by using ventilation grills or ducts. You must
provide two permanent openings: one within 12" of the ceiling and
one within 12" of the floor. Connect these items directly to the
outdoors or spaces open to the outdoors. These spaces include attics
and crawl spaces. Follow the National Fuel Gas Code, ANSI
Z223.1/NFPA 54, Section 5.3, Air for Combustion and Ventilation
for required size of ventilation grills or ducts.
IMPORTANT:
attic if attic has a thermostat-controlled power vent. Heated air
entering the attic will activate the power vent.
Do not provide openings for inlet or outlet air into
12"
Ventilation
Grills
Into Adjoining
Room,
Option 1
Figure 2 - Ventilation Air from Inside Building
Outlet
Air
Or
Remove
Door into
Adjoining
Room,
Option
3
12"
Outlet
Air
Ventilation Grills
Into Adjoining Room,
Option 2
Ventilated
Attic
To Attic
110399-01A
Inlet
Air
Inlet Air
Figure 3 - Ventilation Air from Outdoors
For more information, visit www.desatech.com
For more information, visit www.desatech.com
To
Crawl
Space
Ventilated
Crawl Space
INSTALLATION
8
Check Gas Type
Installation and Clearances for Vent-Free Operation
INSTALLATION
NOTICE: This heater is intended for use as supplemental heat. Use this heater along with your primary
heating system. Do not install this heater as your
primary heat source. If you have a central heating
system, you may run system’s circulating blower
while using heater. This will help circulate the heat
throughout the house. In the event of a power outage,
you can use this heater as your primary heat source.
WARNING: A qualified service person must in-
stall heater. Follow all local codes.
NOTICE: State or local codes may only allow operation of this appliance in a vented configuration. Check
your state or local codes.
WARNING: Make sure the selector switch is in the
OFF position before installing heater (Remote-Ready
Models Only).
WARNING: Before installing in a solid fuel burning fireplace, the chimney flue and firebox must be
cleaned of soot, creosote, ashes and loose paint by
a qualified chimney cleaner. Creosote will ignite if
highly heated. A dirty chimney flue and firebox may
create and distribute soot within the house. Inspect
chimney flue for damage. If damaged, repair flue
damper before operating heater.
CAUTION: This heater creates warm air currents.
These currents move heat to wall surfaces next to
heater. Installing heater next to vinyl or cloth wall
coverings or operating heater where impurities (such
as, but not limited to, tobacco smoke, aromatic
candles, cleaning fluids, oil or kerosene lamps, etc.)
in the air exist, may discolor walls or cause odors.
IMPORTANT:
this is beneficial, installing heater in rooms without enough ventilation air may cause mildew to form from too much moisture. See
Air for Combustion and Ventilation, pages 5 through 7.
Vent-free heaters add moisture to the air. Although
CHECK GAS TYPE
Use the correct gas type (natural or propane/LP) for your unit. If
your gas supply is not correct, do not install log set. Call dealer
where you bought log set for proper type fireplace.
INSTALLATION AND CLEARANCES FOR
VENT-FREE OPERATION
WARNING: Maintain the minimum clearances. If
you can, provide greater clearances from floor, ceiling, and adjoining wall.
MINIMUM FIREPLACE
CLEARANCE TO
COMBUSTIBLE MATERIALS
WARNING: Seal any fresh air vents or ash cleanout doors located on floor or wall of fireplace. If not,
drafting may cause pilot outage or sooting. Use a heatresistant sealant. Do not seal chimney flue damper.
WARNING: Never install the heater
• in a bedroom or bathroom unless installed as a
vented appliance, see page 11 (Remote-Ready and
Variable Manually-Controlled Models Only)
• in a recreational vehicle
• where curtains, furniture, clothing, or other flam-
mable objects are less than 42 inches from the
front, top, or sides of the heater
Installation and Clearances for Vent-Free Operation (Cont.)
INSTALLATION
9
9
Carefully follow the instructions below. This will ensure safe
installation into a masonry, UL127-listed manufactured fireplace,
or listed vent-free firebox.
Minimum Clearances For Side Combustible
Material, Side Wall, and Ceiling
A. Clearances from the side of the fireplace cabinet to any combus-
tible material and wall should follow diagram in Figure 4.
Example:
combustible material and protrudes 3
combustible material must be 4" from the side of the fireplace
cabinet (see Figure 4).
Note:
follow firebox manufacturer’s instructions for minimum clearances
to combustible materials.
B. Clearances from the top of the fireplace opening to the ceiling
should not be less than 42 inches.
*Minimum 16 inches from Side Wall
Figure 4 - Minimum Clearance for Combustible to Wall
NOTICE: Manual control heaters may be used as a
vented product. If so, you must always run heater with
chimney flue damper open. If running heater with
damper open, noncombustible material above fireplace opening is not needed. Go to
Clamp Accessory for Vented Operation,
The face of a mantel, bookshelf, etc. is made of
1
/2" from the wall. This
When installing your gas logs into a manufactured firebox,
Example
*
Installing Damper
page 11.
noncombustible material behind it. Noncombustible material must
extend at least 8" up (for all models). If noncombustible material is
less than 12", you must install the fireplace hood accessory (24", 30"
and 36" Models Only). See Figure 5 for minimum clearances.
If Using Mantel
You must have noncombustible material(s) above the fireplace
opening. Noncombustible materials (such as slate, marble, tile, etc.)
must be at least 1/2 inch thick. With sheet metal, you must have
noncombustible material behind it. Noncombustible material must
extend at least 8 inches up (for all models). If noncombustible
material is less than 12", you must install the fireplace hood
accessory (24", 30" and 36" Models Only). Even if noncombustible
material is more than 12", you may need the hood accessory to
deflect heat away from your mantel shelf. See Figure 5 and Figures
6 and 7, page 9, for minimum clearances.
IMPORTANT:
If you cannot meet these minimum clearances, you
must operate heater with chimney flue damper open. Go to Install-ing Damper Clamp Accessory for Vented Operation, page 11.
NoncombustibleRequirements for
Material Distance (A) Safe Installation
12" or moreNoncombustible material OK.
Between 8" and 12"24" ,30" or 36" Models: Install
fireplace hood accessory (GA6050,
GA6052, or GA6053 see
ries
, page 31).
18" Model: Noncombustible
material OK.
Less than 8"Noncombustible material must be
extended to at least 8". See
8" and 12"
extend material, you must operate
heater with flue damper open.
Heat Resistant
Material
, above. If you cannot
(A)
Accesso-
Between
Minimum Noncombustible Material Clearances
If Not Using Mantel
Note:
If using a mantel proceed to If Using Mantel. If not using a
mantel, follow the information on this page.
You must have noncombustible material(s) above the fireplace
opening. Noncombustible materials (such as slate, marble, tile, etc.)
must be at least 1/2 inch thick. With sheet metal, you must have
In addition to meeting noncombustible material clearances, you
must also meet required clearances between fireplace opening and
mantel shelf. If you do not meet the clearances listed below, you will
need a hood.
Determining Minimum Mantel Clearance
If you meet minimum clearance between mantel shelf and top of
fireplace opening, a hood is not required (see Figure 6).
Determining Minimum Mantel Clearance When
Using a Hood
If minimum clearances in Figure 6 are not met, you must have a
hood. When using a hood there are still certain minimum mantel
clearances required. Follow minimum clearances shown in Figure 7
when using hood.
NOTICE: Surface temperatures of adjacent walls and
mantels become hot during operation. Walls and
mantels above the firebox may become hot to the
touch. If installed properly, these temperatures meet
the requirement of the national product standard.
Follow all minimum clearances shown in this manual.
NOTICE: If your installation does not meet the minimum
clearances shown, you must do one of the following:
• operate the logs only with the flue damper open
• raise the mantel to an acceptable height
• remove the mantel
FLOOR CLEARANCES
A. If installing appliance on the floor level, you must maintain
the minimum distance of 14" to combustibles (see Figure 8).
B. If combustible materials are less than 14" to the fireplace, you
must install appliance at least 5" above the combustible flooring (see Figure 9).
"
Mantel Shelf
18"8"20"
14"
Distances to
Underside of
Mantel
22"
17"
Underside of
Mantel Shelf
24"
20"
Top of Fireplace
Opening
All minimum
distances are
in inches
Log Set
24"/30"/36" Models
18" Model
Minimum NonCombustible
Material
10"
8"
6"
1
/2
2
(A)
12"
8"
Minimum NonCombustible
Material Height
Figure 6 - Minimum Mantel Clearances Without Using Hood
8"
Min.
Mantel Shelf
12"15"18"
Distances to
Underside of
Mantel
Underside of
Mantel Shelf
All minimum
distances are
in inches
20"
Top of Fireplace
Opening
Minimum NonCombustible
Material
12"
10"
8"
6"
1
2
/2
"
Hood
Hood
(GA6050, GA6052,
(GA6050, GA6052)
or GA6053)
Figure 7 - Minimum Mantel Clearances When Using Hood
Combustible
Material
14"
Min.
Noncombustible
Non-Combustible Material
Material
Figure 8 - Minimum Fireplace
Clearances If Installed at
Floor Level
Installing Damper Clamp Accessory for Vented Operation
INSTALLATION
Installing Heater Base Assembly
11
11
INSTALLING DAMPER CLAMP ACCESSORY
FOR VENTED OPERATION
Note:
When used as a vented heater, appliance must be installed
only in a solid-fuel burning fireplace with a working flue and
constructed of noncombustible material.
If your heater is a manually-controlled model, you may use this
heater as a vented product. There are three reasons for operating
your heater in the vented mode.
1.The fireplace does not meet the clearance to combustibles re-
quirements for vent-free operation.
2.State or local codes do not permit vent-free operation.
3.You prefer vented operation.
If reasons number 1 or 2 above apply to you, you must permanently
open chimney flue damper. You must install the damper clamp
accessory (to order, see Accessories, page 31). This will insure vented
operation (see Figure 10). The damper clamp will keep damper open.
Installation instructions are included with clamp accessory.
See chart below for minimum permanent flue opening you must
provide. Attach damper clamp so the minimum permanent flue
opening will be maintained at all times.
WARNING: You must secure this heater to fireplace floor. If not, heater will move when you adjust
controls. Moving heater may cause a gas leak or log
misplacement.
WARNING: If installing in a sunken fireplace,
special care is needed. You must raise the fireplace
floor to allow access to heater control panel. This
will insure adequate air flow and guard against
sooting and controls being damaged. Raise fireplace floor with noncombustible material. Make sure
material is secure.
CAUTION: Do not pick up heater base assembly by
burners. This could damage heater. Only handle base
assembly by grates.
IMPORTANT:
not level, heater will not work properly. For thermostat models,
avoid damage to thermostat bulb. Avoid nicks or sharp bends in
thermostat bulb wire. Keep thermostat bulb in mounting bracket
until ready to mount base to floor. See Optional Positioning OfThermostat Sensing Bulb, page 28.
Installation Items Needed
• hardware package (provided with heater)
• approved flexible gas hose and fittings (not provided) (if allowed
by local codes)
• sealant (resistant to propane/LP gas, not provided)
• electric drill with 3/16" drill bit (metal or masonry as applicable)
• flathead screwdriver
• pipe wrench
1.Apply pipe joint sealant lightly to male threads of gas fitting
(not provided). For Variable Manually-Controlled and Thermostat-Controlled Models connect approved flexible gas hose
to gas regulator of heater (see Figure 11, page 12). For Remote-Ready models connect approved flexible gas hose to gas
control fitting in heater (see Figure 12, page 12).
IMPORTANT:
ing flexible gas hose (Variable Manually-Controlled and Thermostat-Controlled Models Only). Hold gas fitting with wrench
when connecting flexible gas hose (Remote-Ready Models Only).
2.Locate two masonry screws in hardware package.
3.Place heater base in fireplace.
Make sure the heater burners are level. If heater is
Hold gas regulator with wrench when connect-
Figure 10 - Attaching Damper Clamp
For more information, visit www.desatech.com
For more information, visit www.desatech.com
110399-01A
INSTALLATION
12
Installing Heater Base Assembly (Cont.)
INSTALLATION
Continued
4.Place logs in their proper position on heater base (see Installing
Logs, pages 15 through 17).
5.Center heater base and logs front-to-back and side-to-side in
fireplace.
6.Carefully remove logs without moving heater base.
7.Mark screw locations through one hole on each side of the
mounting bracket (see Figures 13, 14 or 15, depending on your
model). If installing in a brick-bottom fireplace, mark screw
locations in mortar joint of bricks.
8.Remove heater base from fireplace. If installing optional control accessories, do so at this time (Remote-Ready Models
Only). Follow all directions provided with accessory .
9.Drill holes at marked locations using 3/16" drill bit.
10. Attach base assembly to fireplace floor using two masonry
screws (in hardware package).
Heater Gas
Regulator
Masonry
Screw
VINTAGE OAK LOG CHASSIS
(Variable Manually-Controlled and
Thermostat-Controlled Models)
Figure 13 - Attaching Heater to Fireplace Floor (Variable ManuallyControlled and Thermostat-Controlled Models Only)
Bracket with
Screw Holes
Masonry
Screw
Fitting
Flexible Gas Hose (if
allowed by local codes)
Figure 11 - Attaching Flexible Gas Hose to Heater Gas
Regulator (Variable Manually-Controlled and ThermostatControlled Models Only)
Flexible Gas
Hose (if allowed
by local codes)
Fitting
Figure 12 - Attaching Flexible Gas Hose to Heater (RemoteReady Models Only)
GOLDEN OAK MODEL CHASSIS
(Variable Manually-Controlled and
Thermostat-Controlled Models)
Figure 14 - Attaching Base to Fireplace Floor (Remote-Ready
Models Only)
Bracket with
Screw Holes
Masonry
Screw
GOLDEN OAK MODEL CHASSIS
(Remote-Ready Models)
Figure 15 - Attaching Base Assembly to Fireplace Floor
For more information, visit www.desatech.com
For more information, visit www.desatech.com
Bracket with
Screw Holes
110399-01A
INSTALLATION
Continued
Connecting To Gas Supply
INSTALLATION
13
13
CONNECTING TO GAS SUPPLY
WARNING: This appliance requires a 1/2" NPT
(National Pipe Thread) inlet connection to the pressure regulator.
WARNING: A qualified service person must connect heater to gas supply. Follow all local codes.
CAUTION: Never connect propane/LP fireplace
directly to the propane/LP supply. This heater requires
an external regulator (not supplied). Install the external
regulator between the heater and propane/LP supply.
WARNING: Never connect natural gas fireplace to
private (non-utility) gas wells. This gas is commonly
known as wellhead gas.
Installation Items Needed
Before installing heater, make sure you have the items listed below.
• external regulator (supplied by installer)
• piping (check local codes)
• sealant (resistant to propane/LP gas)
• equipment shutoff valve *
• test gauge connection *
• sediment trap
• tee joint
• pipe wrench
* A CSA design-certified equipment shutoff valve with 1/8" NPT
tap is an acceptable alternative to test gauge connection. Purchase
the optional CSA design-certified equipment shutoff valve from
your dealer. See Accessories, page 31.
For propane/LP units, the installer must supply an external regulator. The external regulator will reduce incoming gas pressure. You
must reduce incoming gas pressure to between 11 and 14 inches of
water. If you do not reduce incoming gas pressure, heater regulator
damage could occur. Install external regulator with the vent pointing down as shown in Figure 16. Pointing the vent down protects it
from freezing rain or sleet.
Installation must include an equipment shutoff valve, union, and
plugged 1/8" NPT tap. Locate NPT tap within reach for test gauge
hook up. NPT tap must be upstream from heater (see Figures 17 or
18 page 14, depending on your model).
IMPORTANT:
location. The equipment shutoff valve is for turning on or shutting
off the gas to the appliance.
Check your building codes for any special requirements for locating
equipment shutoff valve to fireplaces.
Apply pipe joint sealant lightly to male NPT threads. This will
prevent excess sealant from going into pipe. Excess sealant in pipe
could result in clogged heater valves.
WARNING: Use pipe joint sealant that is resistant
to liquid petroleum (LP) gas.
We recommend that you install a sediment trap in supply line as
shown in Figures 17 or 18 page 14, depending on your model.
Locate sediment trap where it is within reach for cleaning. Install in
piping system between fuel supply and heater. Locate sediment trap
where trapped matter is not likely to freeze. A sediment trap traps
moisture and contaminants. This keeps them from going into heater
controls. If sediment trap is not installed or is installed wrong, heater
may not run properly.
CAUTION: Avoid damage to regulator. Hold gas
regulator with wrench when connecting it to gas
piping and/or fittings (Variable Manually-Controlled
and Thermostat-Controlled Models Only).
CAUTION: Avoid damage to gas control. Hold gas
fitting with wrench when connecting it to gas piping
and/or fittings (Remote-Ready Models Only).
Install equipment shutoff valve in an accessible
External Regulator
Propane/LP
Supply Tank
CAUTION: Use only new, black iron or steel pipe.
Internally-tinned copper tubing may be used in certain
areas. Check your local codes. Use pipe of 1/2" diameter or greater to allow proper gas volume to heater. If
pipe is too small, undue loss of volume will occur.
For more information, visit www.desatech.com
For more information, visit www.desatech.com
110399-01A
Vent Pointing Down
Figure 16 - External Regulator With Vent Pointing Down
INSTALLATION
14
Connecting to Gas Supply (Cont.)
Checking Gas Connections
INSTALLATION
Continued
CSA Design-Certified Equipment
PROPANE/LP
From External
Regulator
(11" W.C.**
to 14" W.C.
Pressure)
NATURAL
From Gas
Meter
(5" W.C.**
to 10.5" W.C.
Pressure)
TeeCapPipe
JointNipple
Figure 17 - Gas Connection (Variable Manually-Controlled and
Thermostat-Controlled Models Only)
CSA Design-Certified Equipment
Shutoff Valve With 1/8" NPT Tap*
Approved Flexible
Gas Hose (if allowed
by local codes)
Gas Control
Figure 18 - Gas Connection (Remote-Ready Models Only)
* Purchase the optional CSA design-certified equipment shutoff valve
from your dealer. See Accessories, page 31.
** Minimum inlet pressure for purpose of input adjustment.
Shutoff Valve With 1/8" NPT Tap*
Approved Flexible
Gas Hose (if allowed
by local codes)
3" Minimum
Sediment Trap
3" Minimum
Pipe CapTee
NippleJoint
Sediment Trap
Gas Regulator
PROPANE/LP From External
Regulator
(11" W.C.**
to 14" W.C.
Pressure)
NATURAL From Gas
Meter
(5" W.C.**
to 10.5" W.C.
Pressure)
CHECKING GAS CONNECTIONS
WARNING: Test all gas piping and connections
for leaks after installing or servicing. Correct all
leaks at once.
WARNING: Never use an open flame to check for
a leak. Apply a noncorrosive leak detection fluid to all
joints. Bubbles forming show a leak. Correct all leaks
at once.
CAUTION: Make sure external regulator has been
installed between propane/LP supply and heater. See
guidelines under
Pressure Testing gas Supply Piping system
Test Pressures In Excess Of 1/2 PSIG (3.5 kPa)
1.Disconnect appliance with its appliance main gas valve (control
valve) and equipment shutoff valve from gas supply piping system. Pressures in excess of 1/2 psig will damage heater regulator.
2.Cap off open end of gas pipe where equipment shutoff valve
was connected.
3. Pressurize supply piping system by either opening
propane/LP supply tank valve for propane/LP gas or opening
main gas valve located on or near gas meter for natural gas, or
using compressed air.
4.Check all joints of gas supply piping system. Apply noncorrosive
leak detection fluid to all joints. Bubbles forming show a leak.
5.Correct all leaks at once.
6.Reconnect heater and equipment shutoff valve to gas supply.
Check reconnected fittings for leaks.
Test Pressures Equal To or Less Than 1/2 PSIG (3.5 kPa)
1.Close equipment shutoff valve (see Figure 19, page 15).
2.Pressurize supply piping system by either opening propane/LP supply tank valve for propane/LP gas or opening main gas valve located on or near gas meter for natural gas, or using compressed air.
3.Check all joints from gas meter to equipment shutoff valve for
natural gas or propane/LP supply to equipment shutoff valve
for propane/LP (see Figures 20 and 21, page 15). Apply noncorrosive leak detection fluid to all joints. Bubbles forming
show a leak.
4.Correct all leaks at once.
Connecting to Gas Supply
, page 13.
For more information, visit www.desatech.com
For more information, visit www.desatech.com
110399-01A
INSTALLATION
Continued
Pressure Testing Heater Gas Connections
1.Open equipment shutoff valve (see Figure 19).
2.Open main gas valve located on or near gas meter for natural
gas or open propane/LP supply tank valve.
3.Make sure control knob of heater is in the OFF position.
4.Check all joints from equipment shutoff valve to thermostat
gas valve (Thermostat-Controlled Models), to control valve
(Manually-Controlled Models), or to gas control (RemoteReady Models)(see Figures 20 and 21). Apply noncorrosive
leak detection fluid to all joints. Bubbles forming show a leak.
5.Correct all leaks at once.
6.Light heater (see Operating Heater, pages 18 through 23, depending on your model). Check all other internal joints for leaks.
7.Turn off heater (see To Turn Off Gas to Appliance, page 19 for
Thermostat-Controlled models, page 20 for Manually-Controlled
Models, or page 22 for Remote-Ready Models).
Gas Meter
Checking Gas Connections (Cont.)
Equipment
Shutoff Valve
INSTALLATION
Installing Logs
Thermostat Gas
Valve or Control
Valve Location
15
15
Equipment
Shutoff
Valve
Figure 19 - Equipment Shutoff Valve
Equipment
Shutoff Valve
Propane/LP
Supply Tank
Figure 20 - Checking Gas Joints (propane/LP only)
ON
Open
POSITION
OFF
POSITION
Closed
Thermostat Gas
Valve or Control
Valve Location
Figure 21 - Checking Gas Joints (Natural Gas Only)
INSTALLING LOGS
WARNING: Failure to position the parts in accordance with these diagrams or failure to use only parts
specifically approved with this heater may result in
property damage or personal injury.
CAUTION: After installation and periodically thereafter, check to ensure that no flame comes in contact
with any log. With the heater set to High, check to see
if flames contact any log. If so, reposition logs according to the log installation instructions in this
manual. Flames contacting logs will create soot.
Vintage Oak Two-Piece Log Set
It is very important to install these logs exactly as instructed. Do not
modify logs. Only use logs supplied with heater.
1.Place front log on top of the grate and over front posts on chassis
(see Figure 22, page 15).
2.Place rear log on rear of chassis (see Figure 22, page 15). Slide
log forward so that it sits against rear posts on chassis.
MPORTANT:
(see Figure 23, page 15).
3.Place lava rock around base of heater if desired.
Make sure logs do not cover any burner ports
110399-01A