Desa DUALBRITE 4291 User Manual

DUALBRITE
MANUAL MODE
AUTO
TEST
®
Motion Sensing Diecast Lantern
TEST
Set the ON-TIME switch on the bottom of the cover plate to TEST.
AUTO
Set ON-TIME switch to 1, 5, or 10 minutes.
TEST 1 5 10 MIN
TEST 1 5 10 MIN
Model 4291
Features
• Light comes on when motion is detected.
• Dusk Accent lighting.
• Photocell keeps the light off during daylight
hours.
This package includes:
• Lantern
• Easy to use universal mounting bracket
(X-Bar)
• Mounting hardware
• Wire nuts
Requirements
• The Light Control requires 120 volts AC.
• If you want to use Manual Mode, the control
must be wired through a switch.
Some codes require installation by a
qualified electrician.
OPERATION
Mode: On-Time Works: Day Night
Test Auto 1, 5, or 10 Min x Manual To Dawn* x Accent 3,6 Hr. to Dawn x
* resets to Auto Mode at dawn.
Note: When first turned on wait about 1 1/2
minutes for the circuitry to calibrate.
IMPORTANT: Attach receipt in case of possible warranty issues.
5 Sec x x
MANUAL MODE
Manual mode only works at night because daylight re­turns the sensor to AUTO.
Flip the light switch off for one second then back on to toggle between AUTO and MANUAL MODE.
Manual mode works only with the ON-TIME switch in the 1, 5, or 10 position.
1 Second
OFF then...
... back on.
Mode Switching Summary
ON-TIME Switch at 1,
5, or 10 minutes
Flip light switch
off for one second
then back on*
* If you get confused while switching modes,
turn the power off for one minute, then back on. After the calibration time the control will be in the AUTO mode.
UALBRITE
D
Light comes on half bright for selected time after dusk (3 hr., 6 hr., until dawn). If motion is sensed, the light turns on full bright for the ON-TIME (1, 5, or 10 minutes) then returns to dim mode.
®
Dimmer Control
© 2006 DESA Specialty Products™ 598-1234-01
INSTALLATION
For best performance, mount the fixture about 6 feet (1.8 m) above the ground.
WARNING: Turn power off at circuit
breaker.
1. Remove
two nuts.
2. Remove
X-Bar.
WIRING
WHITE
One Motion Light
BLACK
BLACK
BLACK
3. Tighten screws
finger tight.
5. Attach X-Bar to
junction box
SENSITIVITY
MIN
4. Set sensitivity on fixture
back to the mid-position.
MAX
Junction
Box
BLACK
WHITE
Two Motion
Lights
WHITE
Twist the junction box wires and the
fixture wires together as shown below. Secure with wire connectors. If you have a metal junction box, you may not need the green “pigtail”. If you are unsure about the grounding method, consult your local building code.
CAUTION: DO NOT connect the RED wire
unless you want to control other lights from the motion sensor.
Recommended Grounding Method
Use a green ground “pigtail” (not provided) and twist one end together with the bare fixture wire and the box ground wire. Secure with a wire connector. Secure the other end of the "pigtail" with the GND screw on the X-bar.
Due to the size and weight of the fixture, you may find it helpful to have an assistant hold the fixture in place while connecting the wires.
Black to black
2
White to white
598-1234-01
OPTIONAL WIRING
When wiring to additional standard
fixture only: Strip the motion sensor's red wire and connect to the standard
light's black wire. Connect all white wires together. Total fixture ratings must not exceed 360 Watts (3.0 A.).
NOTE: All wiring between fixtures should
be run in accordance with the National Electrical Code (Canadian Electrical Code in Canada) through conduit or another acceptable means. Contact a qualified
electrician if there is any question as to the suitability of the system.
BLACK
RED
WHITE
BLACK
(Standard)
WHITE
This fixture is provided with a sensor rated
for 360 Watts. Since the fixture is only rated 100 Watts, 260 Watts of additional load may be controlled by this sensor.
When determining what a fixture is rated
for, do not simply look at the rating on the lamp in the fixture. Look at the marking which specifies the maximum lamp watt­age for which the fixture is suitable.
Once you have selected the fixtures to be
connected and determined their maximum ratings, add these ratings up. For instance, if you have 3 fixtures rated 100 Watts, 150 Watts, and 75 Watts respectively, you have a total load of 325 Watts.
BLACK
WHITE
RED
BLACK
RED
WHITE
Slave
Wiring to Motion Light &
Standard Fixture
Master
Wiring to Control One Motion Sensing Lantern (Slave) from Another (Master)
It is also possible to wire two motion sensing coach lights so that either unit will turn on both lights at the same time (dual master system). It is recommended that only people with plenty of electrical experience attempt this configuration. Please call our customer service number (1-800-858-8501) before attempting this wiring. If the dual master wiring is not
done correctly, it can destroy both motion sensing fixtures and void your warranty.
598-1234-01
3
COMPLETE THE
INSTALLATION
Stuff the wires into the junction box. Make
sure none of the wires get pinched.
Slide the fixture onto the mounting
screws and tighten nuts.
Junction Box
TESTING
Turn on the circuit breaker and light
switch.
NOTE: Sensor has a 1 1/2 minute warm up pe-
riod before it will detect motion. When first turned on, wait 1 1/2 minutes.
Switch the on-time to TEST position and
DUALBRITE® switch to the OFF position.
Install one 100 W max. light bulb.Install the fixture top. Secure with
decorative screws.
After completing the tests on page 5, caulk
fixture mounting surface with silicone
weather sealant.
TEST 1 5 10 MIN
ON-TIME
OFF 3 6 DUSK TO
HOUR DAWN
Avoid aiming the control at:
• Objects that change temperature rapidly,
such as heating vents and air condition- ers. These heat sources could cause false triggering.
• Areas where pets or traffic may trigger
the control.
Nearby large, light-colored objects
reflecting light may trigger the shut-off feature. Do not point other lights at the sensor.
150°
6 ft.
(1.8 m)
30 ft.
(9.1 m)
Maximum Range Maximum Coverage Angle
The detector is less sensitive to motion di rectly towards it and more sensitive to across motion.
Motion
Sensor
Motion
Least Sensitive Most Sensitive
4
598-1234-01
-
Walk through the coverage area noting
1
5
0
°
1
5
0
°
where you are when the lights turn on. Move the sensor head left or right to change the coverage area.
IMPORTANT: Grasp the sensor only as shown and turn the entire sensor. Any other method may damage the sensor. Do not force the sensor past the stop­ping points.
If you need to change the sensitivity,
temporarily remove the fixture and make the adjustment. Too much sensitivity may increase false triggering.
Set the amount of TIME you want the light
to stay on after motion is detected. (1, 5, or 10 minutes).
Set the amount of time after dusk you want
the lights on accent level.
SPECIFICATIONS
Range .........Up to 30 ft. (9.1 m) [varies with
surrounding temperature].
Sensing Angle ............................Up to 150°
Electrical Load .... Up to 100 Watt Maximum
Incandescent.
Sensor Capacity ..... Up to 360 Watt (3.0 A.)
Maximum
Power Requirements ......... 120 VAC, 60 Hz
Operating Modes ............ TEST, AUTO, and
MANUAL MODE
Time Delay ........................1, 5, 10 minutes
DUALBRITE® timer .....3, 6 hrs, Dusk-to-Dawn
598-1234-01
Rotating Sensor Head to Change
Coverage Area
DESA Specialty Products™ reserves the right to discontinue products and to change specifications at any time without incurring any obligation to incorporate new features in products previously sold.
5
TROUBLESHOOTING GUIDE
SYMPTOM
Light will not come on.
Light comes on in daylight.
POSSIBLE CAUSE
1. Light switch is turned off.
2. Bulb is loose or burned out.
3. Fuse is blown or circuit breaker is turned off.
4. Daylight turn-off is in ef fect (recheck after dark).
5. Incorrect circuit wiring, if this is a new installation.
1. Light Control may be in­stalled in a relatively dark location.
2. Light Control is in Test
(Set control switch to an ON-TIME position).
-
SYMPTOM
Light comes on for no apparent reason.
Light stays on continuously.
Light flashes on and off.
POSSIBLE CAUSE
1. Light Control may be sensing small animals or automobile traffic sensitivity).
1.
The sensor is pointed toward a heat source like an air vent, dryer vent, or brightly painted, heat reflective surface (Reduce sensitivity).
1. Light Control is in the Test mode and warming up
(Flashing is normal under these conditions).
(Reduce
TECHNICAL SERVICE
Please call 1-800-858-8501 for assistance before returning product to store.
If you experience a problem, follow this guide. You may also want to visit our Web site at: www.desatech.com. If the problem persists, call* for assistance at 1-800-858-8501, 7:30 AM to 4:30 PM CST (M-F). You may also write* to: DESA Specialty Products™ P.O. Box 90004, Bowling Green, KY 42102-9004 ATTN: Technical Service Specialty Products
* If contacting Technical Service, please have the following information available: Model Number, Date of Purchase, and Place of Purchase.
No Service Parts Available for this Product
This is a “Limited Warranty” which gives you specific legal rights. You may also have other rights which vary
THREE YEAR LIMITED WARRANTY
from state to state or province to province. For a period of three years from the date of purchase, any malfunction caused by factory defective parts or workmanship will be corrected at no charge to you. Not Covered - Repair service, adjustment and calibration due to misuse, abuse or negligence, light bulbs, batteries, and other expendable items are not covered by this warranty. Unauthorized service or modifica­tion of the product or of any furnished component will void this warranty in its entirety. This warranty does not include reimbursement for inconvenience, installation, setup time, loss of use, unauthorized service, or return shipping charges. This warranty covers only DESA Specialty Products™ assembled products and is not extended to other equipment and components that a customer uses in conjunction with our products. THIS WARRANTY IS EXPRESSLY IN LIEU OF ALL OTHER WARRANTIES, EXPRESS OR IMPLIED, INCLUDING ANY WARRANTY, REPRESENTATION OR CONDITION OF MERCHANT ABILITY OR THAT THE PRODUCTS ARE FIT FOR ANY PARTICULAR PURPOSE OR USE, AND SPECIFICALLY IN LIEU OF ALL SPECIAL, INDIRECT, INCIDENTAL, OR CONSEQUENTIAL DAMAGES. REPAIR OR REPLACEMENT SHALL BE THE SOLE REMEDY OF THE CUSTOMER AND THERE SHALL BE NO LIABILITY ON THE PART OF DESA SPECIALTY PRODUCTS™ FOR ANY SPECIAL, INDIRECT, INCIDENTAL, OR CONSEQUENTIAL DAMAGES, INCLUDING BUT NOT LIMITED TO ANY LOSS OF BUSINESS OR PROFITS, WHETHER OR NOT FORESEEABLE. Some states or provinces do not allow the exclusion or limitation of incidental or consequential damages, so the above limitation or exclusion may not apply to you. Proof of purchase is required for warranty claims.