Desa DS-12CH, DS-18CH Instruction Manual

DESA UK Ltd, Warrington, England
INSTRUCTION MANUAL
DS-12CH DS-18CH
Please read and retain these instructions for future reference
AIR CONDITIONER
With DIY Quick Connector
2
INDEX
Index 2
Specification 3
Safety Information 4
Parts 5
Installation 6
Installing the Indoor Unit 7
Installing the Outdoor Unit 8
Testing the Unit 9
Operation 10
Remote Control Operation 11
Setting the Clock 12
Timer Function 12
Sleep Function 12
Setting the Airflow Direction 13
Maintenance 14
Fault Check List 15
3
SPECIFICATION
Model
DS-12CH DS-18CH
Power Supply
(Ph, V~Hz)
1Ph, 220-240V,
50Hz
1Ph, 220-240V,
50Hz Capacity (BTU/hr) 12,000 18,000 Power Consumption
(W)
1,100 1,650
Operating Current (A) 5.0 7.5
Cooling
EER (BTU/w.h) 3.2 3.2 Capacity (BTU/hr) 12,500 18,700 Power Consumption
(W)
1,080 1,610
Operating Current (A) 4.9 7.3
Heating
COP (BTU/w.h) 3.4 3.4
Airflow Volume
M3/hr 540 810
Dehumidifying
L/hr 1.0 1.8
Refrigerant
g/R410a 780 1,400 Noise Level (db(A)) 36 40 Dimensions WxHxD
(mm)
785x275x200 1010x320x210
Packing WxHxD (mm) 860x345x240 1060x366x285
Indoor Unit
Net/Gross Weight (kg) 11/13 21/26 Noise Level (db(A)) 50 52 Dimensions WxHxD
(mm)
800x250x540 800x250x540
Packing WxHxD (mm) 888x344x590 888x344x590
Outdoor Unit
Net/Gross Weight (kg) 37/44 40/48
Suitable Area
M2 18-26 30-43
Please note:
1. Information may vary for technical reasons
2. Measuring condition for above is based on regulation EN14511
4
SAFETY INFORMATION
General Safety
The air conditioner unit must be installed according to the instruction manual
• NEVER use the air conditioner unit near flammable liquids/gases
NEVER use the air conditioner in a confined space where other
heating/cooling appliances are being used unless there is adequate ventilation
Do not place objects on the unit or restrict the air inlet/outlet
Always supervise children and pets when the unit is in use
Always firmly fix the outdoor unit, ensuring the unit is horizontal
Electrical Safety
Always switch the unit off and unplug when not in use
Always use the remote control or emergency switch to turn the unit on/off.
NEVER use the mains power switch to operate the unit
NEVER open the indoor nor outdoor unit
Do not use in overly humid or wet environment
Do not install near ovens/boilers or similar heat producing products
If any leads/cables are damaged, they must be replaced immediately by a
qualified electrician
For Maximum Efficiency
Do not exceed the recommended room size (details in the specification)
Close all doors and windows in the room with the operating air conditioner
unit
Keep curtains and blinds closed if the room is in direct sunlight
Keep filters clean
Once the room has reached the desired conditions, change the
temperature and ventilation settings as required
5
PARTS