Shown with optional
cabinet mantel and
hearth base.
®
WARNING: If the information in this manual is not
followed exactly, a fire or explosion may result causing property damage, personal injury, or loss of life.
— Do not store or use gasoline or other flammable
vapors and liquids in the vicinity of this or any
other appliance.
— WHAT TO DO IF YOU SMELL GAS
• Do not try to light any appliance.
• Do not touch any electrical switch; do not use
any phone in your building.
• Immediately call your gas supplier from a
neighbor’s phone. Follow the gas supplier’s
instructions.
• If you cannot reach your gas supplier, call the
fire department.
— Installation and service must be performed by a
qualified installer, service agency, or the gas
supplier.
This appliance may be installed in an aftermarket* manufactured (mobile) home, where not prohibited
by state or local codes.
* Aftermarket: Completion of sale, not for purpose of resale, from the manufacturer
WARNING: Improper installation, adjustment, alteration, service, or maintenance can cause
injury or property damage. Refer to this manual for correct
installation and operational procedures. For assistance or additional information consult a
qualified installer, service
agency, or the gas supplier.
WARNING: This is an unvented
gas-fired heater. It uses air (oxygen) from the room in which it is
installed. Provisions for adequate combustion and ventilation air must be provided.
Refer to
Ventilation
this manual.
Air for Combustion and
section on page 4 in
Save this manual for future reference.
CGFP28P and CGFP28PT
UNVENTED PROPANE/LP GAS FIREPLACE
SAFETY
INFORMATION
WARNINGS
WARNING ICON G 001
IMPORTANT: Read this owner’s
manual carefully and completely
before trying to assemble, operate, or service this fireplace. Improper use of this fireplace can
cause serious injury or death
from burns, fire, explosion, electrical shock, and carbon monoxide poisoning.
DANGER: Carbon monoxide
poisoning may lead to death!
Carbon Monoxide Poisoning: Early
signs of carbon monoxide poisoning resemble the flu, with headaches, dizziness,
or nausea. If you have these signs, the fireplace may not be working properly. Getfresh air at once! Have fireplace serviced.
Some people are more affected by carbon
monoxide than others. These include pregnant women, people with heart or lung disease or anemia, those under the influence of
alcohol, and those at high altitudes.
Propane Gas: Propane gas is odorless.
An odor-making agent is added to the gas.
The odor helps you detect a gas leak. However, the odor added to the gas can fade. Gas
may be present even though no odor exists.
Make certain you read and understand all
Warnings. Keep this manual for reference.
It is your guide to safe and proper operation
of this fireplace.
WARNING: Any change to
this fireplace or its controls can
be dangerous.
1.This appliance is only for use with the
type of gas indicated on the rating plate.
This appliance is not convertible for use
with other gases.
2.Do not place propane supply tank(s)
inside any structure. Locate propane
supply tank(s) outdoors.
3.If you smell gas
• shut off gas supply
• do not try to light any appliance
• do not touch any electrical switch; do
not use any phone in your building
• immediately call your gas supplier
from a neighbor’s phone. F ollow the
gas supplier’s instructions
• if you cannot reach your gas supplier ,
call the fire department
4.This fireplace shall not be installed in
a bedroom or bathroom.
5.Never install the fireplace
• in a recreational vehicle
• where curtains, furniture, clothing, or
other flammable objects are less than
42 inches from the front, top, or sides
of the fireplace
• in high traffic areas
• in windy or drafty areas
6.Do not use this fireplace as a woodburning fireplace. Use only the logs
provided with the fireplace.
7.Do not add extra logs or ornaments
such as pine cones, vermiculite, or rock
wool. Using these added items can
cause sooting. Do not add lava rock
around base. Rock and debris could fall
into the control area of fireplace.
8.Y ou must operate this fireplace with the
fireplace screen in place. Make sure
fireplace screen is in place before running fireplace.
9.This fireplace is designed to be smokeless. If logs ever appear to smoke, turn
off fireplace and call a qualified service
person.
slight smoking could occur due to log
curing and fireplace burning manufacturing residues.
10. To prevent the creation of soot, follow
the instructions in Cleaning and Main-tenance, page 21.
11. Do not allow fans to blow directly into
the fireplace. Avoid any drafts that alter burner flame patterns. Ceiling fans
can create drafts that alter burner flame
patterns. Altered burner patterns can
cause sooting.
Note:
During initial operation,
12. Before using furniture polish, wax, carpet cleaner, or similar products, turn
heater off. If heated, the vapors from
these products may create a white powder residue within burner box or on
adjacent walls or furniture.
13. Do not use a blower insert, heat exchanger insert or other accessory not
approved for use with this heater.
14. This fireplace needs fresh air ventilation to run properly . This fireplace has
an oxygen depletion sensor (ODS) pilot light safety system. The ODS shuts
down the fireplace if not enough fresh
air is available. See Air for Combus-tion and Ventilation, pages 4 through
6. If fireplace keeps shutting off, see
Troubleshooting , pages 22 through 24.
15. Do not run fireplace
• where flammable liquids or vapors
are used or stored
• under dusty conditions
16. Do not use this fireplace to cook food
or burn paper or other objects.
17. Ne ver place any objects in the fireplace
or on logs.
18. Fireplace front and screen becomes
very hot when running fireplace. K eep
children and adults away from hot surfaces to avoid burns or clothing ignition. Fireplace will remain hot for a
time after shutdown. Allow surf aces to
cool before touching.
19. Carefully supervise young children
when they are in the room with fireplace.
20. Do not use fireplace if any part has been
exposed to or under water . Immediately
call a qualified service technician to
inspect the fireplace and to replace any
part of the control system and any gas
control which has been under water.
21. Do not operate fireplace if any log is
broken. Do not operate fireplace if a
log is chipped (dime-sized or larger).
22. Turn fireplace off and let cool before
servicing. Only a qualified service person should service and repair fireplace.
23. Operating f ireplace above ele vations of
4,500 feet could cause pilot outage.
24. To prevent performance problems, do
not use propane fuel tank of less than
100 lbs. capacity.
2
103414
OWNER’S MANUAL
PRODUCT
IDENTIFICATION
Bottom Mid
Log (#2)
Base
Front Burner
Front Log (#3)
Figure 1 - Log Base Assembly
Top Louvered
Hood
Firebox
Support
Top Log (#4)
Gas Regulator
Rear Log (#1)
Rear Burner
Top Outer
Casing
LOCAL CODES
Install and use fireplace with care. Follow all
local codes. In the absence of local codes, use
the latest edition of The National Fuel GasCode ANS Z223, also known as NFPA 54*.
*Available from:
American National Standards Institute, Inc
1430 Broadway
New York, NY 10018
National Fire Protection Association, Inc.
Batterymarch Park
Quincy, MA 02269
UNPACKING
CAUTION: Do not remove the
metal data plates from the grate
assembly. The data plates contain
important product information.
1.With utility knife, cut the carton all the
way around above the staples on the
bottom tray. Lift the car ton off the firebox. Remove packing.
2.Locate two screws above top corners
of the fireplace screen. Remove and
discard these screws. Lift fireplace
screen up and pull out to remove.
3.Remove protective packaging applied to
logs, log base assembly, and fireplace.
4.Check all items for any shipping damage. If damaged, promptly inform
dealer where you bought fireplace.
.
Screen Assembly
Figure 2 - Fireplace
103414
Rear Access Door
Bottom Louver
Assembly
3
CGFP28P and CGFP28PT
UNVENTED PROPANE/LP GAS FIREPLACE
PRODUCT
FEATURES
OPERATION
This vent-free fireplace is clean burning. It
requires no outside venting. There is no heat
loss out a vent or up a chimney. Heat is
generated by both realistic flames and glowing embers. The fireplace requires no electricity making it ideal for emergency backup heat.
SAFETY FEATURES
This fireplace has a pilot with an Oxygen
Depletion Sensor Shutoff System (ODS).
The ODS/pilot is a required feature for ventfree room heaters. The ODS system protects
against oxygen depletion and any interruption in the fuel supply. If either occurs, the
ODS shuts off gas flow to the burner, turning the fireplace off. An internal regulator
controls fluctuations in your gas pressure.
PIEZO IGNITION SYSTEM
This fireplace has a piezo ignitor. This system requires no matches, batteries, or other
sources to light fireplace.
THERMOSTAT CONTROL
MODELS (CGFP28PT)
These fireplaces have a thermostat sensing
bulb and a control valve. The thermostat
controls the heat output and flame height.
This maintains a consistent room temperature. Even the lowest setting provides realistic flames and glowing embers from two
burners. Selecting higher comfort settings
allows fireplace to run longer, producing
greater heat output. At lower comfort settings, the fireplace will run less. This results
in increased heating comfort. This can also
result in lower gas bills. An optional thermostatically (GA3650T) or manually
(GA3750) controlled blower is available
(see Accessories, page 32).
VARIABLE MANUAL
CONTROL (CGFP28P)
These fireplaces have a variable manual control valve which allows the user to choose the
heat setting that best suits his needs. Any
setting between low and high may be selected
by simply turning the control knob. An optional manually controlled blower (GA3750)
is available (see Accessories, page 32).
AIR FOR
COMBUSTION AND
VENTILATION
WARNING: This heater shall
not be installed in a confined space
or unusually tight construction
unless provisions are provided for
adequate combustion and ventilation air. Read the following instructions to insure proper fresh air for
this and other fuel-burning appliances in your home.
Today’s homes are built more energy efficient than ever. New materials, increased
insulation, and new construction methods
help reduce heat loss in homes. Home owners
weather strip and caulk around windows and
doors to keep the cold air out and the warm air
in. During heating months, home owners
want their homes as airtight as possible.
While it is good to make your home energy
efficient, your home needs to breathe. Fresh
air must enter your home. All fuel-burning
appliances need fresh air for proper combustion and ventilation.
Exhaust fans, fireplaces, clothes dryers, and
fuel burning appliances draw air from the
house to operate. You must provide adequate fresh air for these appliances. This
will insure proper venting of vented fuelburning appliances.
PROVIDING ADEQUATE
VENTILATION
The following are excerpts from National
Fuel Gas Code. NFPA 54/ANS Z223.1, Section 5.3, Air for Combustion and Ventilation.
All spaces in homes fall into one of the three
following ventilation classifications:
1. Unusually Tight Construction
2. Unconfined Space
3. Confined Space
The information on pages 4 through 6 will
help you classify your space and provide
adequate ventilation.
Unusually Tight Construction
The air that leaks around doors and windows may provide enough fresh air for
combustion and ventilation. However, in
4
buildings of unusually tight construction,
you must provide additional fresh air.
Unusually tight construction is defined as construction where:
a. walls and ceilings exposed to the
outside atmosphere have a continuous water vapor retarder with
a rating of one perm (6x10
pa-sec-m2) or less with openings
gasketed or sealed
b. weather stripping has been ad ded
on openable windows and doors
and
c. caulking or sealants are applied to
areas such as joints around window and door frames, between
sole plates and floors, between
wall-ceiling joints, between wall
panels, at penetrations for plumbing, electrical, and gas lines, and
at other openings.
If your home meets all of the three
criteria above, you must provide additional fresh air. See
From Outdoors
If your home does not meet all of the
three criteria above, proceed to
mining Fresh-Air Flow For Fireplace
Location
, page 5..
, page 6.
-11
kg per
and
Ventilation Air
Deter-
Confined Space and Unconfined
Space
The National Fuel Gas Code (ANS Z223.1,
1992 Section 5.3) defines a confined space
as a space whose volume is less than 50
cubic feet per 1,000 Btu per hour (4.8 m3 per
kw) of the aggregate input rating of all
appliances installed in that space and an
unconfined space as a space whose volume
is not less than 50 cubic feet per 1,000 Btu
per hour (4.8 m3 per kw) of the aggregate
input rating of all appliances installed in that
space. Rooms communicating directly with
the space in which the appliances are installed*, through openings not furnished
with doors, are considered a part of the
unconfined space.
This heater shall not be installed in a confined space or unusually tight construction
unless provisions are provided for adequate
combustion and ventilation air.
* Adjoining rooms are communicating only
if there are doorless passageways or ventilation grills between them.
103414
OWNER’S MANUAL
AIR FOR
COMBUSTION AND
VENTILATION
Continued
DETERMINING FRESH-AIR FLOW FOR FIREPLACE LOCATION
Determining if You Have a Confined or Unconfined Space
Use this work sheet to determine if you have a confined or unconfined space.
Space: Includes the room in which you will install fireplace plus any adjoining rooms with doorless passageways or ventilation grills
between the rooms.
1.Determine the volume of the space (length x width x height).
Length x Width x Height = _________________cu. ft. (volume of space)
Example:
If additional ventilation to adjoining room is supplied with grills or openings, add the volume of these rooms to the total vol ume of
the space.
2.Divide the space volume by 50 cubic feet to determine the maximum Btu/Hr the space can support.
_________________ (volume of space) ÷ 50 cu. ft. = (Maximum Btu/Hr the space can support)
Example:
3.Add the Btu/Hr of all fuel burning appliances in the space.
Vent-free fireplace___________________Btu/Hr
Gas water heater*___________________Btu/Hr
Gas furnace___________________Btu/Hr
Vented gas heater___________________Btu/Hr
Gas fireplace logs___________________Btu/Hr
Other gas appliances*+ ___________________Btu/Hr
Total= ___________________Btu/Hr
* Do not include direct-vent gas appliances. Direct-vent draws combustion air from the outdoors and vents to the outdoors.
4.Compare the maximum Btu/Hr the space can support with the actual amount of Btu/Hr used.
_________________ Btu/Hr (maximum the space can support)
_________________ Btu/Hr (actual amount of Btu/Hr used)
Example:
The space in the above example is a confined space because the actual Btu/Hr used is more than the maximum Btu/Hr the space can support.
You must provide additional fresh air. Your options are as follows:
A. Re work w ork sheet, adding the space of an adjoining room. If the e xtra space provides an unconfined space, remove door to adjoin-
ing room or add ventilation grills between rooms. See Ventilation Air from Inside Building, page 6.
B. Vent room directly to the outdoors. See Ventilation Air from Outdoors, page 6.
C. Install a lower Btu/Hr fireplace, if lower Btu/Hr size makes room unconfined.
If the actual Btu/Hr used is less than the maximum Btu/Hr the space can support, the space is an unconfined space. You will need no
additional fresh air ventilation.
Space size 22 ft. (length) x 18 ft. (width) x 8 ft. (ceiling height) = 3168 cu. ft. (volume of space)
3168 cu. ft. (volume of space) ÷ 50 cu. ft. = 63.3 or 63,300 (maximum Btu/Hr the space can support)
Example:
Gas water heater40,000Btu/Hr
Vent-free fireplace +28,000Btu/Hr
Total=68,000Btu/Hr
63,300 Btu/Hr (maximum the space can support)
68,000 Btu/Hr (actual amount of Btu/Hr used)
WARNING: If the area in which the heater may be operated is smaller than that defined as an unconfined space
or if the building is of unusually tight construction, provide adequate combustion and ventilation air by one of
the methods described in the
103414
National Fuel Gas Code, ANS Z223.1, 1992, Section 5.3
5
or applicable local codes.
Continued
CGFP28P and CGFP28PT
UNVENTED PROPANE/LP GAS FIREPLACE
AIR FOR
COMBUSTION AND
VENTILATION
Continued
VENTILATION AIR
Ventilation Air From Inside
Building
This fresh air would come from an adjoining
unconfined space. When ventilating to an
adjoining unconfined space, you must provide two permanent openings: one within
12" of the ceiling and one within 12" of the
floor on the wall connecting the two spaces
(see options 1 and 2, Figure 3). You can also
remove door into adjoining room (see option 3, Figure 3). Follow the National Fuel
Gas Code NFPA 54/ANS Z223.1, Section
5.3, Air for Combustion and Ventilation for
required size of ventilation grills or ducts.
WARNING: Rework worksheet, adding the space of the
adjoining unconfined space. The
combined spaces must have
enough fresh air to supply all
appliances in both spaces.
Ventilation Air From Outdoors
Provide extra fresh air by using ventilation
grills or ducts. You must provide two permanent openings: one within 12" of the
ceiling and one within 12" of the floor.
Connect these items directly to the outdoors
or spaces open to the outdoors. These spaces
include attics and crawl spaces.
IMPORTANT:
inlet or outlet air into attic if attic has a
thermostat-controlled power vent. Heated air
entering the attic will activate the power vent.
Do not provide openings for
12"
Ventilation
Grills
Into Adjoining
Room,
Option 1
Figure 3 - Ventilation Air from Inside Building
Outlet
Air
Inlet
Air
Figure 4 - Ventilation Air from Outdoors
Or
Remove
Door into
Adjoining
Room,
Option
3
12"
Outlet
Air
Inlet Air
Ventilation Grills
Into Adjoining Room,
Option 2
Ventilated
Attic
Ventilated
Crawl Space
To Attic
To
Crawl
Space
6
103414
INSTALLATION
NOTICE: This heater is intended
for use as supplemental heat. Use
this heater along with your primary heating system. Do not install this heater as your primary
heat source. If you have a central
heating system, you may run
system’s circulating blower while
using heater. This will help circulate the heat throughout the
house. In the event of a power
outage, you can use this heater
as your primary heat source.
NOTICE: A qualified service person must install fireplace. Follow
all local codes.
WARNING: Never install the
fireplace
• in a bedroom or bathroom
• in a recreational vehicle
• where curtains, furniture,
clothing, or other flammable
objects are less than 42 inches
from the front, top, or sides of
the fireplace
• in high traffic areas
• in windy or drafty areas
CAUTION: This fireplace creates warm air currents. These currents move heat to wall surfaces
next to fireplace. Installing fireplace next to vinyl or cloth wall
coverings or operating fireplace
where impurities (such as tobacco smoke, aromatic candles,
cleaning fluids, oil or kerosene
lamps, etc.) in the air exist, may
discolor walls.
IMPORTANT:
ture to the air. Although this is beneficial,
installing fireplace in rooms without enough
ventilation air may cause mildew to form
from too much moisture. See Air for Com-bustion and Ventilation, pages 4 through 6.
IMPORTANT:
level. If fireplace is not level, log set will not
work properly.
Vent-free heaters add mois-
Make sure the fireplace is
OWNER’S MANUAL
Note:
Your Comfort Glow fireplace is de-
signed to be used in zero clearance installations. Wall or framing material can be placed
directly against any exterior surface on the
rear, sides, or top of your fireplace, except
where stand-off spacers are integrally attached. If stand-off spacers are attached to
your fireplace, these spacers can be placed
directly against wall or framing materials.
Use the dimensions shown for rough openings to create the easiest installation (see
Built-In Fireplace Installation, page 13).
CHECK GAS TYPE
Use only propane gas. If your gas supply is
not propane gas, do not install fireplace.
Call dealer where you bought fireplace for
proper type fireplace.
ELECTRICAL HOOKUP
(When Using Optional
Blower)
The optional blower accessories (GA3650T
and GA3750) have a power cord 5 feet in
length. You must locate the fireplace within
reach of a 120 volt grounded electrical outlet, or install an electrical outlet within reach
of the blower power cord. For built-in installation, an outlet accessory (GA3555) is
available (see Accessories, page 32). This
allows the outlet to be installed inside the
firebox. All electrical installations should
be performed by a qualified service person.
ASSEMBLING AND
ATTACHING OPTIONAL
BRASS TRIM ACCESSORY
(Included with Mantel)
Note:
The instructions below show assem-
bling and attaching brass trim to fireplace.
Do not yet install brass trim if performing a
built-in installation (See Built-In FireplaceInstallation, page 13).
1.Remove packaging from three pieces
of brass trim.
2.Locate four brass screws, two adjusting plates with set screws, and two
shims in the hardware packet.
3.Align shim under adjusting plate as
shown in Figure 5.
4.Slide one end of adjusting plate/shim
in slot on mitered edge of top brass trim
(see Figure 5).
5.Slide other end of adjusting plate/shim
in slot on mitered edge of side brass
trim (see Figure 5).
6.While firmly holding edges of brass
trim together, tighten both set screws
on the adjusting plate with slotted
screwdriver.
7.Repeat steps 1 through 6 for other side.
8.Tighten trim hanging screws (#10 x
6.25 shoulder) into holes in cabinets.
Place the assembled trim onto fireplace
cabinet. Align hanging notches on trim
with hanging screws on side of fireplace
(see Figure 6). Push trim firmly into
place, sliding hanging notches over
hanging screws.
Side
Brass
Adjusting
Trim
Plate
Slot
Figure 5 - Assembling Brass Trim
Assembled
Brass Trim
Figure 6 - Attaching Brass Trim to Fireplace
Set Screws
Mitered Edge
Hanging
Notches on
Trim
Top
Brass
Trim
Shim
Slot
Trim Hanging
Screws
Continued
103414
7
CGFP28P and CGFP28PT
AUTO
OFF
ON
3
2
1
UNVENTED PROPANE/LP GAS FIREPLACE
INSTALLATION
Continued
INSTALLING GA3650T
BLOWER ACCESSORY
(For CGFP28P Model Only)
NOTICE: Shut-off gas supply and
disconnect heater from gas supply. Contact a qualified service
person to do this.
1.Remove fireplace screen (see Figure 7).
WARNING: You must operate
this fireplace with the fireplace
screen in place. Make sure fireplace screen is in place before
running fireplace.
2.If logs are installed, carefully remove
the logs and set aside, noting the properly mounted location of each.
3.Remove screws that attach log base assembly to fireplace (do not discard).
Carefully lift up log base assembly and
remove from fireplace, taking care to
pull flexible gas line through the access holes (see Figure 8).
7.Remove the three screws (do not discard) and cover plate from center of
firebox wrapper rear wall. Discard this
cover plate.
8.Mount the supplied thermostatic switch
and cover assembly into firebox wrapper wall. Do this by feeding terminal
ends of wire harness into the hole. Allow wires to fall to bottom of firebox
cavity (see Figure 11).
9.Using three screws from step 7, attach
switch and cover assembly to firebox
wrapper rear wall. Tighten screws
firmly (see Figure 11).
10. Mount selector switch to front flange
of left floor support bracket. Align
graphics on switch upright and push
firmly to snap switch into rectangular
hole. Push the selector switch to the off
(middle) position (see Figure 10).
11. Install three plastic wire clips provided
into floor support bracket (see Figure 10).
Secure by pushing clips firmly into holes.
WARNING: Failure to connect
all wires properly as indicated
may cause electrical short circuit
or personal injury. A qualified
electrician should check that all
connections are made properly.
Screws
Log Base
Flexible Gas Line
Figure 8 - Removing Log Base from Fireplace
Exhaust
Port
#8 Screws
Blower
Lower Rear
Wall of Firebox
Figure 9 - Mounting Blower to Firebox
CAUTION: Do not pick up log
base assembly by burners. This
could damage burners. Only
handle base by grates.
4.Place the blower against lower rear wall
of firebox outer wrapper with the exhaust port directed upward. Align the
holes in top mounting tabs of blower
with holes in wall of wrapper (see Figure 9). Using two #8 screws provided,
mount blower and tighten screws firml y.
5.Route terminals end of power cord
through large hole near top of left floor
support bracket. Make sure to pass the
cord from the outside (left side) towards
the center of firebox (see Figure 10).
6.Using two #6 screws provided attach
power cord mounting plate to the outside
face of left floor support bracket. Drive
screws from inside (right side) of floor support bracket. Attach the plate so that the
power cord is directed towards rear of firebox (see Figure 10). Tighten scre ws firmly .
Notches
Screen Mounting Screws
Figure 7 - Removing Fireplace Screen
8
Wire
Selector
Switch
Figure 10 - Installing Power Cord, Mounting Plate, and Selector switch
Figure 11 - Installing Switch and Cover
Assembly
#6 Screws
Switch and Cover Assembly
#10 Screw
Clips
103414
OWNER’S MANUAL
Blue
Fan Switch
(Off/On/Auto)
Red
Fan
Switch
(N.O.)
Green
White
On
110/115
V.A.C.
Blower
Motor
Black
Off
1
2
3
Auto
INSTALLATION
Continued
12. Attach green ground wire ring terminal
to floor support bracket using #10 sheet
metal grounding screw provided (see
Figure 10, page 8). Tighten scre w firmly .
13. Attach all five remaining wiring terminals
to the appropriate switch or motor terminal. Carefully note the correct color coding (see Figures 12 and 14). Push female
wire terminals fully onto male terminal.
14. Secure wires into the appropriate plastic wire clips (see Figure 12).
15. Plug in blower power cord.
If your fireplace system is installed
as a freestanding unit with an accessory mantel, install one plastic bush-
ing (provided) into the 1.5" hole in the
lower left side of the outer casing (see
Figure 13). Route power cord through
plastic bushing. Plug the power cord
into a properly grounded three-prong
wall receptacle near the firebox.
If your fireplace system installation is
recessed, install one plastic bushing pro-
vided into the 1.5" hole near the middle of
the left floor support bracket (see Figure
13). Route power cord through plastic
bushing. Plug the power cord into a properly installed duplex outlet. (If an outlet is
not available, the accessory model
GA3555 Outlet Kit with cover can be installed in your fireplace. This will supply
a convenient three-prong grounded electrical outlet for your blower. Refer to the
installation manual provided with the
model GA3555 accessory for instructions
on wiring the duplex outlet.)
16. Check to make sure that the power cord
and wires are completely clear of the
blower wheel and that there are no other
foreign objects in blower wheel. Turn
blower on by pushing the selector switch
to the on position and check for operation. Turn blo wer off before continuing.
17. Peel of f the backing paper and stick the
supplied wiring diagram decal on the
firebox bottom approximately 12" in
front of blower.
WARNING: Never touch the
blower wheel while in operation.
103414
18. Replace log base assembly in fireplace.
Feed flexible gas supply line into fireplace base area while replacing log base
assembly. Make sure the entir e flexible
gas line is in fireplace base area.
Note:
If firebrick is installed, make sure
the back of the firebox bottom slides
under the rear panel of the firebrick. (lift
the firebrick up if necessary.)
IMPORTANT:
Do not pick up log base
assembly by burners. This could damage
burners. Only handle base by grates.
19. Reattach log base assembly to fireplace
with screws removed in step 3.
20. Install logs and fireplace screen per in-
structions in operating manual provided
with fireplace.
WARNING: Failure to position
the parts in accordance with supplied diagrams or failure to use
only parts specifically approved
with this heater may result in damage or personal injury.
21. Connect gas supply to fireplace per instructions in operating manual provided
with fireplace.
NOTICE: A qualified service person must connect fireplace to
gas supply. Follow all local codes.
Note:
To prevent short
circuit, white wire MUST
be connected to motor.
Blue
Wire
Blue
Wire
AUTO
3
OFF
2
ON
1
Red Wire
Figure 12 - Wire Attachment
Black
Wire
To Switch and
Cover Assembly
White
Wire
Green
Wire
9
If any of the original wire as supplied with
the appliance must be replaced, it must be
replaced with 105˚C wire or it's equivalent.
Bushing Location for
Freestanding Installation
Bushing Location
for Recessed
Installation
Figure 13 - Installing Bushings
Figure 14 - Wiring Diagram
OPERATING THE BLOWER
Light your gas appliance with the blower
off. After about 5 minutes, turn the blower
on to deliver heated air at the top louvers.
The thermostatic ally-controlled blower features a three position switch. The three settings are: ON, OFF, and AUTO. In the ON
position, the blower will operate constantly.
In the OFF position, the blower will not
operate. In the AUTO position, the blower
will start when the thermostat senses a sufficient increase in firebox temperature.
Note:
Your gas logs and thermostat blower
will not turn on and off at the same time. The
fireplace may run for several minutes before
the blower turns on. After the heater modulates to the pilot position, the blower will
continue to run. The blower will shut off
after the firebox temperature decreases.
Note:
It is safe to operate fireplace with
blower turned off. However, the blower helps
distribute heated air from the fireplace.
Note:
Periodically check the louvers of the
firebox and remove any dust, dirt, or other
obstructions.
CGFP28P and CGFP28PT
UNVENTED PROPANE/LP GAS FIREPLACE
INSTALLATION
Continued
INSTALLING GA3650T
BLOWER ACCESSORY
(For CGFP28PT Model Only)
NOTICE: Shut-off gas supply and
disconnect heater from gas supply. Contact a qualified service
person to do this.
1.Remove fireplace screen (see Figure 15).
WARNING: You must operate
this fireplace with the fireplace
screen in place. Make sure fireplace screen is in place before
running fireplace.
2.If logs are installed, carefully remove
the logs and set aside, noting the properly mounted location of each.
3.Remove screws that attach log base assembly to fireplace. Carefully lift up log
base assembly and remove from fireplace, taking care to pull flexible gas line
through the access holes (see Figure 16).
CAUTION: Do not pick up log
base assembly by burners. This
could damage burners. Only
handle base by grates.
7.Place control knob provided on plastic
control shaft of speed control.
8.Mount the speed control on the front
leg of the left floor support bracket using 2 screws provided (see Figure 18).
Notches
Screen Mounting Screws
Figure 15 - Removing Fireplace Screen
Flexible
Gas Line
Lower
Rear Wall
of Firebox
Blower
Screws
Exhaust Port
Top Mounting Tab
Power Cord
Figure 17 - Mounting Blower to Firebox
Left Floor
Support
Bracket
4.Attach power cord to blower motor by
firmly pushing the two female terminals of the power cord onto the two
spade terminals on blower motor. Using screw provided, attach ringed terminal of power cord to mounting tab
of blower housing (see Figure 17).
Tighten screw securely.
5.Place the blower against lower rear wall
of firebox outer wrapper with the exhaust port directed upward. Align the
holes in top mounting tabs of blower
with holes in wall of wrapper (see Figure 17). Using 2 screws provided, mount
blower and tighten screws securely.
6.Be certain that all wire terminals are
securely attached to terminals on
blower motor and that the screw retaining the green ground wire is tight.
Screws
Log Base
Figure 16 - Removing Log Base from
Fireplace
10
Screws
Speed
Control
Control
Control
Knob
Figure 18 - Attaching Speed Control to
Firebox
Shaft
103414
OWNER’S MANUAL
INSTALLATION
Continued
9.Plug in blower power cord.
a. If your fire place system is installed
as a freestanding unit with an accessory mantel, determine whether
the power cord will exit the left side
or the right side of the firebox. Install 1 plastic bushing provided into
the 1.5" hole in the floor support
bracket on the exit side (see Figure
19). Install the second plastic bushing provided into the 1.5" hole in the
outer casing through which the
power cord will exit. Route power
cord through both plastic bushings
and plug the power cord into a properly grounded 3-prong wall receptacle near the firebox.
b.If your fireplace system installation
is recessed, you must install GA3555
Outlet kit with cover in your fireplace
which will supply a convenient 3prong grounded electrical outlet for
your blower. Refer to the installation
manual provided with the model
GA3555 accessory for instructions on
wiring the duplex outlet.
Note:
A qualified installer must
make all electrical connections.
10. Check to make sure that the power cord
is completely clear of the blower wheel
and that there are no other foreign objects in blower wheel. Turn blower on
and check for operation. Turn blower
off by rotating knob fully counterclockwise before continuing.
11. Peel off the backing paper and stick the
supplied wiring diagram decal on the
firebox bottom approximately 12" in
front of blower and 3" to the right of the
blower speed control. (see Figure 20).
WARNING: Never touch the
blower wheel while in operation.
12. Replace log base assembly in fireplace.
Feed flexible gas supply line into fireplace base area while replacing log base
assembly. Make sure the entir e flexible
gas line is in fireplace base area.
Note:
If firebrick is installed, make sure
the back of the firebox bottom slides
under the rear panel of the firebrick. (lift
the firebrick up if necessary.)
IMPORTANT:
assembly by burners. This could damage
burners. Only handle base by grates.
13. Reattach log base assembly to fireplace
with screws removed in step 3.
Note:
items.
14. Install logs and fireplace screen per instructions in operating manual provided
with fireplace.
Do not pick up log base
Discard the remaining hardware
WARNING: Failure to position
the parts in accordance with supplied diagrams or failure to use
only parts specifically approved
with this heater may result in damage or personal injury.
15. Connect gas supply to fireplace per instructions in operating manual provided
with fireplace.
NOTICE: A qualified service person must connect fireplace to
gas supply. Follow all local codes.
Operating the Blower
Light your gas appliance with the blower
off. After about 15 minutes, turn the blower
on to deliver heated air at the top louvers.
The blower features a variable control which
allows you to select the speed you desire.
Note:
Periodically check the louvers of the
firebox and remove any dust, dirt, or other
obstructions.
Right Floor
Support
Bracket
Figure 19 - Installing Plastic Bushing for
Power Cord
itch
w
ariable
V
Blower
Motor
Fan S
n
O
lack
B
ff
hite
O
lack
W
B
lack
B
lack
B
.
hite
.C
W
110/115
.A
reen
V
G
Figure 20 - Location of Wiring Diagram Decal, 12" in Front of Blower and 3" from
Blower Speed Control
Plastic
Bushing
Wiring
Diagram
WARNING: Never attempt to service heater
while it is plugged in, operating, or hot. Burns and
electrical shock could result. Only a qualified ser vice person should service or repair heater.
If any of the original wire as supplied with the appliance
must be replaced, it must be replaced with 105°C wire or
it’s equivalent.
WARNING: Label all wires prior to disconnection when servicing controls. Wiring errors
can cause improper and dangerous operation.
Verify proper operation after servicing.
Variable
Fan Switch
Off
110/115
V.A.C.
Black
Green
120 Vac. 60 Hz. . 78 Amps
DESA International, Bowling Green, KY
Black
On
Black
Black
WhiteWhite
Blower
Motor
101584-05
103414
11