US and Canada Regulations
This device complies with Part 15 of the FCC Rules, Canadian ICES-003 Rules.
Operation is subject to the following two conditions:
(1) this device may not cause harmful interference, and
(2) this device must accept any interference received, including interference that
may cause undesired operation.
NOTE: This equipment has been tested and found to comply with the limits for a Class A
digital device, pursuant to Part 15 of the FCC Rules. These limits are designed to
provide reasonable protection against harmful interference when the equipment is
operated in a commercial environment. This equipment generates, uses, and can
radiate radio frequency energy and, if not installed and used in accordance with the
instruction manual, may cause harmful interference to radio communications. Operation
of this equipment in a residential area is likely to cause harmful interference in which
case the user will be required to correct the interference at his own expense.
NOTE: This Class A digital apparatus complies with Canadian ICES-003.
Cet appareil numérique de la classe A est conforme à la norme NMB-003 du Canada.
FCC WARNING: Changes or modifications not expressly approved by the party
responsible for compliance could void the user’s authority to operate the equipment.
Page 4
Page 5
i
SAFETY PRECAUTIONS
Be sure to observe all these safety precautions.
Please READ through this manual carefully. It will enable you to use the QK11-U
correctly.
Always keep this manual nearby for speedy reference.
Strict observance of these warning and caution indications are a MUST for preventing accidents which could result in bodily injury and substantial property damage. Make sure you fully understand all definitions of these terms and related symbols given below, before you proceed to the text itself.
WARNING
Alerts you to those conditions which could cause serious bodily injury or death if the instructions are not followed correctly.
CAUTION
Alerts you to those conditions which could cause minor bodily injury or substantial property damage if the instructions are not followed correctly.
Meaning of Symbols
A triangle (
Ì) with a picture inside alerts you to a warning of danger. Here
you see the warning for electrical shock.
A diagonal line through a circle ([) alerts you to something you should not do; it may or may not have a picture inside. Here you see a screwdriver inside the circle, meaning that you should not disassemble.
A black circle (Q) with a picture inside alerts you to something you MUST do. This example shows that you MUST unplug the power cord.
Page 6
ii
WARNING
When designing systems such as medicine management system that
could affect people's lives, take potential dangers into serious consideration and make redundancy systems and safety engineering which render those dangers even if data is entered incorrectly.
If abnormal phenomenon such as smoke, abnormal odors and noises
occur, immediately pull out the connector of the QK11-U from computer etc. devices, and contact dealer to solve.
It could cause a fire or electric shock if continuing to use in such a case.
If foreign material or water gets into the QK11-U, immediately pull out
the connector of the QK11-U from computer etc. devices, and contact dealer to solve.
It could cause a fire or electric shock if continuing to use in such a case.
If you drop the QK11-U on the ground, cause it unable to use or its
housing to be damaged during use. Please pull out connector of the QK11-U from computer etc. devices, and contact dealer to solve.
Never bring any metals into contact with the output terminals.
Doing so could produce a large current through the QK11-U resulting in heat or fire, as well as damage to the QK11-U.
Keep the QK11-U away from water or moisture.
Getting the QK11-U wet could result in a fire or electrical shock.
Never use the QK11-U on the line voltage other than the specified level.
Doing so could cause the QK11-U to break or burn.
Do not use the QK11-U where any inflammable gases may be emitted;
doing so could cause fire.
IMPORTANT: To system engineers
Page 7
iii
WARNING
If the power cable of the QK11-U is damaged (exposed or broken lead
wires etc.), please contact dealer to solve.
It could cause a fire or electric shock if continuing to use in such a case.
Do not subject the scanning window of the QK11-U to direct sunlight
for extended periods.
Doing so could damage the QK11-U, resulting in a fire.
CAUTION
Do not put the QK11-U on an unstable or inclined plane.
It may drop, creating injuries.
Never put the QK11-U in places where there are excessively high
temperatures, such as inside closed-up automobiles, or in places exposed to direct sunlight.
Doing so could affect the housing or parts, resulting in a fire.
Avoid using the QK11-U in extremely humid or dusty areas, or where
there are drastic temperature changes. Moisture or dust will get into the QK11-U, resulting in malfunction, fire or electrical shock.
Do not place the QK11-U anyplace where it may be subjected to oily
smoke or steam, e.g., near a cooking range or humidifier.
Doing so could result in a fire or electrical shock.
Never disassemble or modify the QK11-U.
Doing so could result in an accident such as fire or electrical shock.
Never
Disassemble
If the scanner is not used for an extended period of time, unplug the
scanner.
Neglecting this could cause a fire.
Page 8
iv
CAUTION
Never cover or wrap up the QK11-U in a cloth or blanket.
Doing so could cause the unit to heat up inside, deforming its housing, resulting in a fire.
Always use the QK11-U in a well-ventilated area.
Do not insert or drop foreign materials such as metals or anything
inflammable through the openings (vents or scanning window) into the QK11-U.
Doing so could result in a fire or electrical shock.
Do not scratch or modify the QK11-U or its interface cable. Do not
bend, twist, pull, or heat the cable.
Doing so could damage the QK11-U or its interface cable, creating a fire hazard.
Do not put heavy material on the QK11-U or its interface cable, or allow
the cable to get pressed under heavy material.
Do not look into the light source from the scanning window of the
QK11-U or do not point the scanning window at other people’s eyes.
Eyesight may be damaged by direct exposure to this light.
Do not use the QK11-U if your hands are wet or damp.
Doing so could result in an electrical shock.
Never use chemicals or organic solvents such as benzene and thinner
to clean the housing. Do not apply insecticide to the QK11-U.
Doing so could result in a marred or cracked housing, electrical shock or fire.
Be sure to hold the connector when unplugging the scanner connector.
Pulling the cord could damage it, which could lead to burning, electric shock or a fire.
Page 9
v
CAUTION
If lightening occurs, immediately unplug the scanner.
Continuing to use could cause electric shock.
Before cleaning, be sure to unplug the scanner.
Cleaning with power cord plugged in could cause electric shock.
If the interface cable is damaged (e.g., exposed or broken lead wires),
stop using it and contact your nearest dealer.
Failure to do so could result in a fire or electrical shock.
Page 10
vi
Proper Care of the QK11-U
When cleaning, always unplug the connector for safety.
Dust or dirt on scanning window will affect the reading of codes: Clean the window before using the scanner. For cleaning, first use air brush, etc. to blow off dust, and then lightly wipe dirt off using dry, soft cloth (eyeglasses cleaning cloth, etc.).
Wipe off hard-to-remove dirt with a fully wrung out cloth moistened in water with diluted neutral detergent, and then use a dry, soft cloth to wipe off moisture so that no detergent remains.
Any dirt or scratch on scanning window will affect the reading of codes: Ask your dealer to replace the scanning window.
Page 11
Content Overviews
SAFETY PRECAUTIONS................................................................................................i
Chapter 1. How to Use ...................................................................................................1
Chapter 2. How to read.................................................................................................14
Chapter 3 Communications ..........................................................................................15
Chapter 4 Parameters and Defaults..............................................................................21
Chapter 5 QR-coded Parameter Menu .........................................................................23
Menu control .........................................................................................................24
Transmission format..............................................................................................25
Setting 2D code reading .......................................................................................28
Setting barcode reading........................................................................................29
Appendix. Specifications...............................................................................................33
Page 12
Page 13
1
Chapter 1. How to Use
Scanning window
OK LED
Lights when reading is successful.
POWER LED
Lights when power is turned on.
Beeper outlet
Page 14
2
 QK11-U USB Driver Installation
This scanner can communicate with PC via the USB-COM interface. Install the USB device driver contained in the provided CD-ROM for communications via USB-COM interface: You can also download the newest version of this driver from DENSO WAVE website:
http://www.denso-wave.com/
The downloaded, compressed file contains the driver and uninstaller. Store the file in the desired folder, and double-click the file icon: The file can then be self-extracted. Connect the scanner interface cable to the USB port of PC: “Add New Hardware Wizard” will automatically start. Set up the USB device driver according to the wizard screen. The next and subsequent pages will show the procedures for setting up the driver on each OS: Windows 98SE, Me, 2000 or XP.
Cautions when connecting USB cable
It will take five to ten seconds for PC to recognize USB-COM device:
Therefore, wait for ten seconds or more to disconnect or connect USB-COM connector again after the connector is connected or disconnected.
USB connector can be connected or disconnected even when the power of PC is ON.
However, do not connect or disconnect USB connector when PC is in the standby (suspended) mode.
Do not connect or disconnect any other USB devices while processing connection of
our USB device.
If USB cable is disconnected during communication, not only will data be lost but the
system may be affected. Therefore, do not disconnect USB cable during communication.
Directly connect QK11-U to USB port of PC or self-power hub. If it cannot be
connected to hub (depending on type of hub) and operation is not stable, connect it directly to USB port of PC.
Cautions when installing USB device driver
If the DENSO WAVE USB-COM driver has not yet been installed, do not connect
QK11-U to USB port of PC when turning PC on: Since installation of USB driver starts during startup of Windows, the installation will not proceed properly.
If you are already using our USB-COM products with our USB-COM driver, the
USB-COM driver installed can be used for QK11-U, and new installation is not necessary. If you want to install a new driver, use the designated uninstaller to uninstall the previously installed driver.
Page 15
3
When installing the driver, be sure to specify the folder in which the driver
corresponding to your Windows version has been installed. If the driver for a different version has been installed, use the Folder Options window to choose “Show all files” or “Do not show hidden files and folders”, and then perform the following.
- If the driver for Windows
®
2000/XP has been installed in Windows® 98SE/Me PC:
(1) Open Device Manager and delete DENSO WAVE USB-COM Port with
attached.
(2) If these files are in the following folders, delete them:
C:\Windows\Inf\Other\ DENSO WAVEdwcom.inf C:\Windows\Inf\ Dwcom.inf,Dwcom.pnf, Dwcom9x.inf,Dwcom9.pnf, Dwport.inf,Dwport.pnf C:\Windows\System\ Dwport.vxd C:\Windows\Sytem32\drivers\ Dwport.sys
(3) Restart the PC.
- If the driver for Windows
®
98/98SE/Me has been installed in Windows® 2000/XP
PC. (1) Open Device Manager and delete USB Device QK11-U. (2) Delete the Oem*.inf file that has the same contents as Dwcom9x.inf from
C:\Winnt\Inf folder. (To search for the file, use Notepad to open Dwcom9x.inf
on CD, and copy the character string in the first row. Then open the
C:\Winnt\Inf folder, use the “Search” window to paste the character string on
the “A word or phrase in the file” column, and then click the Search button.)
(3) Delete Oem*.pnf from the above folder (* is the same number as that of the
above deleted file).
(4) If these files are in the following folders, delete them.
C:\Winn\Inf\ Dwcom.inf,Dwcom.pnf,
Dwcom9x.inf,Dwcom9.pnf, Dwport.inf,Dwport.pnf C:\Windows\System\ Dwport.vxd C:\Windows\Sytem32\drivers\ Dwcom9x.sys
Note: With Windows
®
XP, C:\Windows\ appears instead of C:\Winnt\.
(5) Restart the PC.
After performing the above, install the driver again.
Be sure to store the driver for Windows
®
98SE/Me (dwcom9x.ini, dwcom9x.sys,
dwport.ini, dwport.vxd) and the driver for Windows
®
2000/XP (dwcom.ini, dwcom.sys)
in different folders. (Do not uncompress the driver for Windows
®
98SE/Me and the
driver for Windows
®
2000/XP in the same folder.)
If our USB-COM driver cannot be installed, a similar USB-COM driver has possibly
been used. In this case, delete the corresponding USB-COM driver from device manager and then perform installation. However, before deleting, make sure that the corresponding USB driver is not used for other devices.
Page 16
4
Installation procedure Follow the procedure shown below and install the driver in attached CD-ROM.
The provided CD-ROM contains a driver for Windows
®
98SE/Me, a driver for
Windows
®
2000/XP, and a designated uninstaller that can be used for all Windows®
in common.
Please use the designated uninstaller for uninstallation of a driver.
For Windows
®
2000/XP, administrative permission is necessary to install/uninstall
driver.
1 Windows® 98SE
(1) The power supply of a personal computer is turned on, and Windows® 98SE is
started.
(2) Double-click the compressed file for self-extraction.
(5) Choose "Search for the best driver for
your device (Recommended)" and clic
k
"Next".
(3) Connect QK11-U to your PC directly,
then a new hardware "USB Device QK11-U" is found.
(4) "Add New Hardware Wizard" starts,
then click "Next".
Page 17
5
(9) If the next screen is displayed, clic
k
"Finish".
After copying driver files is finished, "New hardware found" messages abou
t
"Unknown device" and "DENSO WAVE USB-COM Port" are displayed. Then all of install process is over.
(6) Check the “Specify a location” box, input
the folder in which the driver for Windows
®
98SE/Me is stored, and then click “Next”. (The left figure shows that the driver is stored in D:\DRIVER\WIN9X.)
(7) "DENSO WAVE USB-COM Port" is
found as "The updated diver
(Recommended)", then click "Next".
(8) Make sure that “DENSO WAVE
USB-COM Port” is displayed on the screen showing message “Windows is now ready to install the best driver fo
r
this device”, and then click “Next”.
Page 18
6
(10) The check of connection is performed
on the screen of "Device Manager".
If "DENSO WAVE USB-COM Port" is added to the item of "Port (COM & LPT)", it connects normally.
When the item is not added or become "
" and " ", please remove this driver with the uninstaller. After uninstalling and rebooting your PC, redo connection and driver installation again.
2 Windows® Me
(1) The power supply of a personal computer is turned on, and Windows® Me is
started.
(2) Double-click the compressed file for self-extraction.
(3) Connect QK11-U to your PC directly, then a new hardware "USB Device QK11-U"
is found.
(4) "Add New Hardware Wizard" starts,
then check the box of "Specify the location of the driver [Advanced]" and click "Next".
(5) Check the “Specify a location” box,
input the folder in which the driver fo
r
Windows® 98SE/Me is stored, and then click “Next”. (The left figure shows that the driver is stored in D: \DRIVER\WIN9X.)
Page 19
7
(6) Make sure that “DENSO WAVE
USB-COM Port” is displayed on the
screen showing message “Windows is
now ready to install the best driver fo
r
this device”, and then click “Next”.
(7) If the next screen is displayed, clic
k
"Finish".
A
fter copying driver files is finished,
"New hardware found" messages abou
t
"Unknown device" and "DENSO WAVE USB-COM Port" are displayed. Then all of install process is over.
(8) The check of connection is performed
on the screen of "Device Manager".
If "DENSO WAVE USB-COM Port" is added to the item of "Port (COM & LPT)", it connects normally.
When the item is not added or become "
" and " ", please remove this driver with the uninstaller. After uninstalling and rebooting your PC, redo connection and driver installation again.
Page 20
8
3 Windows® 2000
(1) The power supply of a personal computer is turned on, and Windows® 2000 is
started. Perform logon only from user with Administrator authority.
(2) Double-click the compressed file for self-extraction.
(3) Connect QK11-U to your PC directly,
then a new hardware "USB Device QK11-U" is found.
(4) "Found New Hardware Wizard" starts,
then click "Next".
(5) Choose "Search for a suitable driver fo
r
my device (Recommended) " and clic
k
"Next".
(6) Insert CD-ROM to your PC and check
the box of "Specify a location", then clic
k
"Next"
Page 21
9
(9) If the caution about "Digital Signature
Not Found" is displayed, you must continue this installation. Therefore, click "Yes".
(10) If the completion screen is displayed,
click "Finish".
(7) Input the folder in which the driver for
Windows
®
2000/XP is stored, and then click “OK”. (The left figure shows that the driver is stored in D: \DRIVER\WIN2K.)
(8) If "DENSO WAVE USB-COM Port" is
found, then click "Next". (The left figure shows that DWCOM.INF is stored in D: \DRIVER\WIN2K.)
Page 22
10
(11) The check of connection is performed
on the screen of "Device Manager".
If "DENSO WAVE USB-COM Port" is added to the item of "Port (COM & LPT)", it connects normally.
When the item is not added o
r
become " " and " ", please remove this driver with the uninstaller. Afte
r
uninstalling and rebooting your PC, redo connection and driver installation again.
Page 23
11
4 Windows® XP
(1) The power supply of a personal computer is turned on, and Windows® XP is
started. Perform logon only from user with Administrator authority.
(2) Double-click the compressed file for self-extraction.
(3) Connect QK11-U to your PC directly,
then a new hardware "USB Device QK11-U" is found.
(4) "Found New Hardware Wizard" starts,
then check the box of "Install from a lis
t
or specific location [Advanced]" and click "Next".
(5) Choose “Search for the best driver in
these locations.” check the box “Include this location in the search”, input the folder in which the driver for Windows
®
2000/XP is stored, and then click “OK”. (The left figure shows that the driver is stored in D: \DRIVER\WIN2K.)
(6) If the caution about Windows Logo
testing is displayed, you must continue this installation. Therefore, click "Continue Anyway".
Page 24
12
(7) If the completion screen is displayed,
click "Finish".
(8) After copying driver files is finished,the
hint message; "Found New Hardware" are displayed.
Then all of install process is over.
(9) The check of connection is performed on
the screen of "Device Manager".
If "DENSO WAVE USB-COM Port" is added to the item of "Port (COM & LPT)", it connects normally.
When the item is not added or become
Page 25
13
 Setting initial conditions
Although the communication conditions and specifications of codes to be read have
been set at the factory, they can be modified using the QR-coded parameter menu.
Notes: (1) Check “4. Parameters and Defaults” and “5. QR-coded parameter menu” for
details on QR-coded parameter menu.
(2) The contents set using QR-coded parameter menu will be stored in memory of
scanner even if power is turned off.
 Cautions for connections
Cautions
Make some allowance for scanner cable.
Do not leave the scanner cable on the floor.
Do not step on the cable or let it get caught on anything so that it gets scratched.
Be sure to hold the connector securely when plugging in and unplugging the
USB cable.
 Cautions for installation
Caution Remarks Do not install the scanner in a place that is exposed to direct sunlight or near a heater. Do not install it where the temperature and humidity are high, such as in greenhouse, or where the temperature is extremely low, such as in a refrigerator.
The circuits and optical components in scanner can be damaged in an environment where the temperature is extremely high or low, or the humidity is very high.
Do not install where water may be splashed.
Water entering the scanner could
cause fault. It is recommended that you firmly secure the scanner or cable on a table where the scanner is set up, to prevent it from falling off the table. Bundle the surplus cable so that the scanner does not fall when the cable gets caught on something.
If the scanner falls, its appearance
may be damaged or it may
malfunction.
Do not install near a device that generates high frequencies.
High frequencies could cause the
scanner to malfunction. Set up the scanner so that no sunlight or strong light from some lighting device, etc. enters the scanning window.
If the sunlight or strong light from
some lighting device, etc. enters the
scanning window, reading may be
impossible.
Page 26
14
Chapter 2. How to read
Scanning Codes
Turn power on: The QK11-U will be ready for scanning. In this status, bring the LCD of a mobile phone near the scanning window as shown in the figure below. The QK11-U will read codes, output the data, sound buzzer and cause the OK LED to light.
Reading may be impossible depending on the mobile phone model, setting status of
contrast and backlight, or the condition of LCD surface (pasting of seal, scratches, etc.).
By command control, QK11-U is ready for scanning, it can change into a standby state or a reading code can be set up. Please refer to 3. Communications about the method of command control.
Re-read prevention
The QK11-U supports the re-read prevention function, so that if a code fits on the scanning window, it will not read the same code multiple times in succession. Therefore, if you want the QK11-U to read the same code again, separate the code from the scanning window for at least one second to release the re-read prevention function. However, if you fit a low-quality code that cannot be read for more than one second on the window, the QK11-U can re-read the code at an interval of one second or more.
Page 27
15
Chapter 3 Communications
QK11-U employs USB1.1 standard to integrate virtual COM port driver special for computers. All communication software based on serial port formerly could use this product. You may set various communications conditions by scanning QR-coded parameters printed in Chapter 5.
Precautions for use
Please assign correct COM port to the device through the device manager before
use when connecting scanner for the first time or after changing the connecting port of QK11-U in case of Windows 2000 or Windows XP.
In case of Windows 98 SE or Windows Me as operation system, COM port can not
be fixed due to it is distributed automatically by the operation system. So when connecting QK11-U for the first time or having connected it, perform the following operation, COM port could be changed after restarting the computer. If performing the following operation after connecting it for the first time, please restart the computer and confirm the COM port through the device manager under the system in the control panel to use.
- Change the set number of QK11-U to be connected
- Change the connecting port of QK11-U
Please assign different COM port to different communication software when
multi-communication software being turned on.
When the communication software is turned on, some computers may have
communication malfunction after interruption status is released. In such a case, turn off the communication software, and then re-operate it again.
Transmission rate, data bit, parity check and stop bit set by communication
software based on serial port will be omitted, so do not change these settings. Flow control option should be "hardware (RTS/CTS)" or "nil".
Virtual COM port of computer and QK11-U are connected by the following virtual
means.
Computer
QK11-U
TxD RxD
RxD TxD
RTS CTS
CTS
DTR
DSR
DCD
Page 28
16
Data Transfer
 Transmission format
Header Code ID mark No. of digits Data read Terminator BCC
(1) Header
You may select either "No header" or STX.
(2) Terminator
You may select ETX, CR, LF, or CR LF.
(3) BCC
The data following the header, and up to the terminator, are exclusive OR; these data are transferred byte by byte in binary codes.
You select whether BCC is to be transferred or not. Note that BCC cannot be transferred without a header.
(4) Code ID marks
Code ID marks are characters that identify the types of two-dimensional codes and bar codes. You may select whether those ID marks will be transferred, by using the QR-coded parameter menu.
Code type Code ID mark
QR code Q
UPC-A or EAN-13 A
UPC-E C
EAN-8 B
CODE39 M
Interleaved 2 of 5 I
CODABAR N
CODE128 K
EAN-128 W
Page 29
17
(5) No. of digits
The number of digits in code data is expressed in 4 bytes. You may select whether it will be transferred, by using the QR-coded parameter menu.
n1: 4th digit (0 to 9) n2: 3rd digit (0 to 9) n3: 2nd digit (0 to 9) n4: 1st digit (0 to 9)
(6) Code data
The QK11-U will transfer data read whose contents differ depending upon the code type as described below.
QR Code
All data read
UPC-A
0 S X1 X2 X3 X4 X5 X6 X7 X8 X9 X10 C/D
where, S: Number system character
X1 to X10: Data digits
C/D: Check digit
UPC-E
X1 X2 X3 X4 X5 X6 C/D
where, X1 to X6: Data digits
C/D: Check digit
EAN-13
Y1 Y2 X1 X2 X3 X4 X5 X6 X7 X8 X9 X10 C/D
where, Yn: Flag character
X1 to X10: Data digits C/D: Check digit
EAN-8
Y1 Y2 X1 X2 X3 X4 X5 C/D
where, Yn: Flag character
X1 to X5: Data digits C/D: Check digit
Page 30
18
CODE39 and Interleaved 2 of 5(ITF)
Data read except for the start/stop codes
CODABAR (NW-7)
Data read, including/excluding start/stop codes
CODE128 (EAN-128)
Data read except for start/stop codes, FNC codes*, and check digit
Note that FNC1 placed in any positions except the 1st and 2nd positions immediately following the start code will be converted into GS (1Dh) and then transmitted. If FNC1 immediately follows the start code, the code system will be identified as EAN-128 and the code mark "W" will be used.
You may select whether to transmit the start/stop codes or not, by using the QR-coded parameter menu.
Page 31
19
Control Commands
Issuing commands from PC, etc. allows you to set the read status and read codes.
Command/response communication format
Header Command Terminator
Controlling with commands
Command Response Content
Z (Note 1) None
Standby for reading:
When QK11-U receives “Z” command, it will stop reading and enter the reading standby status.
R (Note 1) None
Start of reading:
When QK11-U receives “R” command, it will enter the
reading enable status and start to read codes.
S OK/NG To specify the codes to be read (see the table below for
parameters)
LA OK/NG Automatically controls on/off of illumination LED.
LR OK/NG Always turns illumination LED on during reading operation
(turns it off in reading standby status).
LZ OK/NG Always turns illumination LED off.
PW
(Note 2)
OK/NG Stores in flash memory the status designated by control
command. Without this command, the status set by a command will be reset whenever power is turned off.
VER Ver.n.nn To confirm version n.nn: Version No.
Note 1: Reading enable status when power is turned on. Note 2: Do not turn power off until the OK/NG response is received after the PW
command has been transmitted.
Page 32
20
Setting S command parameters You can specify the following parameters for S command:
Codes to be read Format
Micro QR code Q
UPC-A/UPC-E/EAN-13/EAN-8 A
Interleaved 2 of 5 I (reading enabled without check digit)
I:C (reading enabled with check digit)
CODABAR N (reading enabled without check digit)
N:C (reading enabled with check digit)
CODE39 M (reading enabled without check digit)
M:C (reading enabled with check digit)
CODE128/EAN128 K
When specifying multiple parameters, use commas to delimit them. Example: When SA,N:C,M,K is specified, reading of the following codes will be enabled: QR code, with CODABAR CD, without CODE39 CD, CODE128/EAN128
Page 33
21
Chapter 4 Parameters and Defaults
The table below lists the parameters and their default values. Note that the defaults given below are values preset when the QK11-U leaves the factory. Some of the communications parameters and readable bar code settings may have been modified by dealers according to your needs.
You may change parameters given in the table below by using the QR-coded parameter menu given in Chapter 5. QR-coded parameter menu will be stored in the memory of the QK11-U.
Parameter group Parameters Function Factory defaults
Transmission format
Header None
STX
Terminator ETX
CR LF CR LF
Transmission of code
ID mark
Disabled Enabled
Transmission of no.
of digits
Disabled Enabled
BCC Disabled
Enabled
Setting 2D code reading
Reading MicroQR Disabled
Enabled
Page 34
22
Setting barcode reading
UPC-A/E and EAN-13/8
Disabled Enabled
Interleaved 2 of 5 Disabled
Enabled (without check digits )
Enabled (with check digits)
CODE128(EAN-128) Disabled
Enabled
CODABAR (NW-7) Disabled
Enabled (without check digits)
Enabled (with check digits)
Transmission of starter/ stop codes for CODABAR (NW-7)
Disabled Enabled
CODE39 Disabled
Enabled (without check digits)
Enabled (with check digits)
Other settings Beeper control Disabled
Enabled
Reading
confirmation LED
Disabled Enabled
Page 35
23
Chapter 5 QR-coded Parameter Menu
The QR-coded parameter menu allows you to change a variety of functions built in the QK11-U according to the procedure below.
Parameter change procedure
(1) Make the QK11-U ready for scan. (2) Scan the "Start setting" code in the menu control shown on the next page. (3) Scan a QR code(s) of the parameter(s) you want to set. (4) Scan the "End setting" code in the menu control.
This stores new settings in the memory and completes the parameter change procedure. The QK11-U will become ready to scan. If you turn off the power, those new settings will be retained.
NOTE: If you turn off the power without scanning the "End setting" code, new
settings you made will be canceled.
To restore factory defaults, scan the "Defaults" code in the menu control.
To cancel the parameter change procedure, scan the "Cancel" code.
Page 36
24
 Menu control
"Start setting"
"Cancel"
"Defaults"
"End setting"
Page 37
25
 Transmission format
Header
"None" (default)
"STX"
Page 38
26
Termi n ator
"ETX"
"CR" (default)
"LF"
"CRLF"
Page 39
27
Transmission of code ID mark
"Disabled" (default)
"Enabled"
Transmission of no. of digits
"Disabled" (default)
"Enabled"
Page 40
28
BCC
"Disabled" (default)
"Enabled"
 Setting 2D code reading
Reading MicroQR
"Disabled" (default)
"Enabled"
Page 41
29
 Setting barcode reading
UPC-A/E and EAN-13/8
"Disabled"
"Enabled" (default)
Interleaved 2 of 5
"Enabled with check
digits"
"Disabled"
"Enabled without
check digits" (default)
Page 42
30
CODABAR (NW-7)
"Disabled"
"Enabled without
check digits" (default)
"Enabled with check
digits"
Transmission of start/stop codes for CODABAR (NW-7)
"Disabled"
"Enabled" (default)
Page 43
31
CODE39
"Disabled"
"Enabled without
check digits" (default)
"Enabled with check
digits"
CODE128(EAN-128)
"Disabled"
"Enabled" (default)
Page 44
32
Beeper control
"Disabled"
"Enabled" (default)
Reading confirmation LED
"Disabled"
"Enabled" (default)
Page 45
33
Appendix. Specifications
External dimensions 163 x 72 x 54 mm (cable:1.5m)
Weight
Approx. 370g
Resolution 0.33mm min.
for two-dimensional codes
0.26mm min. for bar codes
Scanning performance
Mobile phone LCD
Readable codes
Model 1 and Model 2 of QR Code, MicroQR, UPC-A/E and EAN-13/8
Resolution 0.33 mm min.
for two-dimensional codes
0.25mm min. for bar codes
Printing
on paper
Readable codes
Model 1 and Model 2 of QR Code, MicroQR, UPC-A/E, EAN-13/8, CODE39, CODABAR (NW-7), Interleaved 2 of 5(ITF), and CODE128 (EAN-128)
Standard USB1.1 specifications Interface
Connector USB plug type A
(JST UB) connector
Environments Operating temperature
range
0°C to 40°C
Operating humidity range 10 to 85% RH
(without dew condensation)
Ambience Without dust, dirt,
or corrosive gases
Power ratings (DC) Drive voltage 4.75 to 5.25 VDC
(supplied from USB port)
Power consumption Max. 500mA (at 5.0VDC)
Page 46
Page 47
Specifications are subject to change without notice.
DENSO WAVE INCORPORATED does not assume any product liability arising out of,
or in connection with, the application or use of any product, circuit, or application described herein.
Intellectual Property Precaution
DENSO WAVE INCORPORATED (“DENSO WAVE”) takes reasonable precautions to ensure its products do not infringe upon any patent of other intellectual property rights of other(s), but DENSO WAVE cannot be responsible for any patent or other intellectual property right infringement(s) or violation(s) which arise from (i) the use of DENSO WAVE’s product(s) in connection or in combination with other component(s), product(s), data processing system(s) or equipment or software not supplied from DENSO WAVE; (ii) the use of DENSO WAVE’s products in a manner for which the same were not intended nor designed; or (iii) any modification of DENSO WAVE’s products by other(s) than DENSO WAVE.
Fixed Type 2D Code Scanner
QK11-U
User's Manual
First Edition, November 2003
DENSO WAVE INCORPORATED
The purpose of this manual is to provide accurate information in the handling and operating of the QK11-U. Please feel free to send your comments regarding any errors or omissions you may have found, or any suggestions you may have for generally improving the manual.
In no event will DENSO WAVE be liable for any direct or indirect damages resulting from the application of the information in this manual.
Page 48
4-2-12, Toranomon, Minato-ku, Tokyo, Japan 105-0001 http://www.denso-wave.com
496817-0560
Loading...