This is a Class A product. In a domestic environment this product may cause radio interference in which case the
user may be required to take adequate measures.
FCC Regulations
This device complies with Part 15 of the FCC Rules. Operation is subject to the following two conditions:
(1) This device may not cause harmful interference, and
(2) this device must accept any interference received, including interference that may cause undesired
operation.
NOTE: This equipment has been tested and found to comply with the limits for a Class A digital device,
pursuant to Part 15 of the FCC Rules. These limits are designed to provide reasonable protection against harmful
interference when the equipment is operated in a commercial environment. This equipment generates, uses, and
can radiate radio frequency energy and, if not installed and used in accordance with the instruction manual, may
cause harmful interference to radio communications. Operation of this equipment in a residential area is likely to
cause harmful interference in which case the user will be required to correct the interference at his own expense.
DENSO WAVE INCORPORATED does not assume any product liability arising out of, or in connection with,
the application or use of any product, circuit, or application described herein.
If it is judged by DENSO WAVE INCORPORATED that malfunction of the product is due to the product
having been dropped or subjected to impact, repairs will be made at a reasonable charge even within the
warranty period.
Intellectual Property Precaution
DENSO WAVE INCORPORATED ("DENSO WAVE") takes reasonable precautions to ensure its products do
not infringe upon any patent of other intellectual property rights of other(s), but DENSO WAVE cannot be
responsible for any patent or other intellectual property right infringement(s) or violation(s) which arise from (i)
the use of DENSO WAVE's product(s) in connection or in combination with other component(s), product(s),
data processing system(s) or equipment or software not supplied from DENSO WAVE; (ii) the use of DENSO
WAVE's products in a manner for which the same were not intended nor designed; or (iii) any modification of
DENSO WAVE's products by other(s) than DENSO WAVE.
All rights reserved. No part of this publication may be reproduced in any form or by any means without permission in
writing from the publisher.
All products and company names mentioned in this manual are trademarks or registered trademarks of their respective
holders.
Specifications are subject to change without prior notice.
Page 3
Contents
Preface ............................................................................................................................................................................. i
SAFETY PRECAUTIONS.............................................................................................................................................. ii
Care and Maintenance ..................................................................................................................................................... v
Chapter 1 Parts Names and Functions.......................................................................................................................... 1
2.1 Connecting the Interface Cable to the Scanner ........................................................................................... 2
2.2 Connecting the Scanner to Your Computer ................................................................................................ 3
Chapter 3 Reading Bar Codes ...................................................................................................................................... 5
Chapter 4 Customizing the Scanner ............................................................................................................................. 7
Chapter 5 Scanning Control ......................................................................................................................................... 8
5.1 Trigger Switch Control ................................................................................................................................ 8
5.2 Software Control ......................................................................................................................................... 9
5.3 Auto Sensing Mode—Automatic Detection of Labels ............................................................................... 11
Chapter 6 Magic Key Control ...................................................................................................................................... 12
7.1 Data Verification Mode............................................................................................................................... 14
7.1.3 Verification result output ....................................................................................................................... 17
7.1.4 Output of the master data registered...................................................................................................... 17
7.2 Specifying the Numbers of Digits of Standard 2of5 and Interleaved 2of5 Symbols to Read,
by Scanning Bar Codes ............................................................................................................................... 18
Chapter 8 Data Editing ................................................................................................................................................. 19
8.1 Extracting Data ............................................................................................................................................ 19
8.2 Substituting Data ......................................................................................................................................... 20
8.3 Blocksorting Data ........................................................................................................................................ 21
8.4 Parenthesizing AIs (Application Identifier) in EAN-128 Data................................................................... 22
8.5 Extracting AI (Application Identifier)-Prefixed Strings from EAN-128 Data........................................... 22
8.6 Data Editing Notes ...................................................................................................................................... 23
8.6.1 Data edit conditions ............................................................................................................................... 23
8.6.2 Rules for data editing............................................................................................................................. 23
8.6.3 AI table................................................................................................................................................... 24
Chapter 9 Beeper, Indicator LED and Vibrator ........................................................................................................... 29
9.2 Indicator LED .............................................................................................................................................. 31
10.3 Communication Format............................................................................................................................... 34
10.3.1 Data transmission format....................................................................................................................... 34
10.3.2 GTIN format conversion........................................................................................................................ 38
Chapter 11 Parameters and Defaults ............................................................................................................................ 39
(1) Interface to the host ........................................................................................................................ 39
(2) Asynchronous data transmission (RS-232C interface) .................................................................. 39
Appendix 2 Bar Code Sample Label ............................................................................................................................ 80
Page 5
Preface
This user's manual sets forth the procedures for handling, connecting, operating, and cleaning your bar code handy
scanner. Before you do anything else, study it carefully to make sure that you use the product both correctly and
effectively. Also keep it handy for ready reference.
i
Page 6
SAFETY PRECAUTIONS
r
t
Be sure to observe all these safety precautions.
Please READ through these instructions carefully. They will enable you to use the scanner correctly.
Always keep this manual nearby for speedy reference.
Strict observance of these warnings and cautions is a MUST for preventing accidents that could result in bodily injury
and substantial property damage. Make sure you fully understand all definitions of these terms and symbols given
below before you proceed to the text itself.
Alerts you to those conditions that could cause serious bodily injury or death if the
instructions are not followed correctly.
Alerts you to those conditions that could cause minor bodily injury or substantial property
damage if the instructions are not followed correctly.
Meaning of Symbols
A triangle (
electrical shock.
A diagonal line through a circle (
picture inside. Here you see a screwdriver inside the circle, meaning that you should not disassemble.
A black circle (
you MUST unplug the power cord.
) with a picture inside alerts you to a warning of danger. Here you see the warning fo
) warns you of something you should not do; it may or may not have a
) with a picture inside alerts you to something you MUST do. This example shows tha
ii
Page 7
• When introducing the scanner in those systems that could affect human lives (e.g., medicines
To System Designers:
management system), develop applications carefully through redundancy and safety design
which avoids the feasibility of affecting human lives even if a data error occurs.
• Keep the AC adapter from water.
Failure to do so could cause fire or electrical shock.
• Use the dedicated AC adapter only.
Failure to do so could result in fire.
• If the power cord of the AC adapter is damaged (e.g., exposed or broken lead wires), stop
using it and contact your nearest dealer.
Failure to do so could result in a fire or electrical shock.
• Never bring any metals into contact with the terminals in connectors.
Doing so could produce a large current through the scanner, resulting in heat or fire, as well as
damage to the scanner.
• Never use the scanner on the line voltage other than the specified level.
Doing so could cause the scanner to break or burn.
• Do not use the scanner where any inflammable gases may be emitted.
Doing so could cause fire.
• Do not scratch, modify, bend, twist, pull, or heat the power cable of the AC adapter. Do not
place heavy material on the cable or allow the cable to get pressed under heavy material.
Doing so could break the cable, resulting in a fire.
• Do not subject the scanning window of the scanner to direct sunlight for extended periods.
Doing so could damage the scanner, resulting in a fire.
• If smoke, abnormal odors or noises come from the scanner, immediately switch off the host
computer, disconnect the AC adapter and the interface cable, and contact your nearest dealer.
Failure to do so could cause fire or electrical shock.
• If foreign material or water gets into the scanner, immediately unplug the AC adapter and the
interface cable, and contact your nearest dealer.
Failure to do so could cause fire or electrical shock.
• If you drop the scanner so as to affect the operation or damage its housing, switch off the host
computer, unplug the AC adapter and the interface cable, and contact your nearest dealer.
Failure to do so could cause fire or electrical shock.
iii
Page 8
Never
disassemble
• Never disassemble or modify the scanner; doing so could result in an accident such as break or
fire.
Doing so could result in a fire or electrical shock.
• Do not put the scanner on an unstable or inclined plane.
The scanner may drop, creating injuries.
• Never put the scanner in places where there are excessively high temperatures, such as inside
closed-up automobiles, or in places exposed to direct sunlight.
Doing so could affect the housing or parts, resulting in a fire.
• Avoid using the scanner in extremely humid areas, or where there are drastic temperature
changes.
Moisture will get into the scanner, resulting in malfunction, fire or electrical shock.
• Do not place the scanner anyplace where it may be subjected to oily smoke or steam, e.g., near
a cooking range or humidifier.
Doing so could result in a fire or electrical shock.
• Never cover or wrap up the scanner or AC adapter in a cloth or blanket.
Doing so could cause the unit to heat up inside, deforming its housing, resulting in a fire.
Always use the scanner and AC adapter in a well-ventilated area.
• Keep the power cable of the AC adapter from any heating equipment.
Failure to do so could melt the sheathing, resulting in a fire or electrical shock.
• Do not insert or drop foreign materials such as metals or anything inflammable through the
openings (vents or scanning window) into the scanner.
Doing so could result in a fire or electrical shock.
• Do not scratch or modify the scanner or its interface cable. Do not bend, twist, pull, or heat the
cable.
Doing so could damage the scanner or its interface cable, creating a fire hazard.
• Do not put heavy material on the scanner or its interface cable, or allow the cable to get pressed
under heavy material.
• Do not look into the light source from the scanning window or do not point the scanning window
at other people's eyes.
Eyesight may be damaged by direct exposure to this light.
• Do not use the scanner if your hands are wet or damp.
Doing so could result in an electrical shock.
• Never use chemicals or organic solvents such as benzene and thinner to clean the housing. Do
not apply insecticide to the scanner.
Doing so could result in a marred or cracked housing, electrical shock or fire.
• Do not use the scanner with anti-slip gloves containing plasticizer.
The scanner housing may be broken, creating injuries, electrical shock, or fire.
iv
Page 9
• When disconnecting the AC adapter from the wall socket, hold the AC adapter body not the
power cable.
The power cable may be broken, resulting in a burnt AC adapter, electrical shock, or fire.
• If the interface cable is damaged (e.g., exposed or broken lead wires), stop using it and contact
your nearest dealer.
Failure to do so could result in a fire or electrical shock.
• If you are not using the scanner for a long time, be sure to unplug the AC adapter from the wall
socket for safety.
Failure to do so could result in a fire.
• During electrical storm activity, always unplug the AC adapter from the wall socket.
Exposure to power surges could result in a damaged scanner or fire.
• When taking care of the scanner, unplug the AC adapter from the wall socket for safety.
Failure to do so could result in an electrical shock.
• Do not drop the scanner.
The scanner housing may be broken, creating injuries.
Using the scanner whose housing is broken could result in smoke or fire.
Unplug the AC adapter from the wall socket and contact your nearest dealer.
Care and Maintenance
Dust or dirt accumulating on the clear plate of the bar code reading window will affect reading performance. If you
use the scanner in dusty areas, therefore, periodically check the clear plate and clean it if dusty.
• To clean the plate, first blow the dust away with an airbrush. Then wipe the plate with a cotton swab or the similar
soft one gently.
• If sand or hard particles have accumulated, never rub the plate; doing so will scratch or damage it. Blow the
particles away with an airbrush or a soft brush.
Limited Warranty on Software Products
In no event will DENSO WAVE be liable for direct, indirect, special, incidental, or consequential damages (including
imaginary profits or damages resulting from interruption of operation or loss of business information) resulting from
any defect in the software or its documentation or resulting from inability to apply the software or its documentation.
v
Page 10
Chapter 1 Parts Names and Functions
Reading window
Point this at the bar code
to read.
Trigger switch
Press this to read a bar code.
The following trigger switch operating
modes are available:
• Auto-off mode 1
• Auto-off mode 2
• Momentary switching mode 1
• Momentary switching mode 2
• Continuous reading mode
(The factory default is momentary
switching mode 1.)
In addition, the auto sensing mode is
also available for automatic trigger
operation.
Refer to Chapter 5 for details.
Indicator LED
This turns blue after a successful read and red if
there is an error.
(Refer to Chapter 9 for details.)
Magic key
This key functions as an auxiliary key for
reads, data transfers, and the like. These
auxiliary functions include:
• Illumination LED switching function
• Data retransfer function
• Specific character transfer function
• Ready/standby switching function
• Auto sensing mode switching function
• Continuous reading mode switching
function
(The factory configuration assigns none
of these functions to this key.)
Refer to Chapter 6 for details.
Interface cable
There are two types of
interface cables available.
• RS-232C interface
• PS/2 keyboard interface
1
Page 11
Chapter 2 Preparation
2.1 Connecting the Interface Cable to the Scanner
(1) Pull the connector cover of the interface cable off its connector as shown below.
(2) Plug the interface cable connector into the connector located in the bottom of the scanner.
Note: As shown below, hold the scanner body, align the
and fully insert the interface cable connector.
Scanner
Interface cable connector
Connector cover
▼ mark on the cable connector with that on the scanner,
▼ mark
▼ mark
(3) Align the two bosses on the connector cover with cutouts in the scanner body, fit the connector cover into the
scanner, and turn it clockwise to lock it.
Cutout
Connector cover
Boss
Turn the cover until the
bosses come to be
horizontal.
Connector cover
2
Page 12
A
2.2 Connecting the Scanner to Your Computer
Using the RS-232C interface
(1) Connect the RS-232C interface cable to your computer.
C adapter
Scanner
RS-232C interface cable
(2) Plug the AC adapter into the DC power jack provided in the cable connector.
(3) If the interface setting has been changed from the RS-232C interface (factory default) to the PS/2 keyboard
interface, change it back to the RS-232C interface by scanning the following bar code:
RS-232C interface
Note: When disconnecting the interface cable or DC power jack, hold the connector housings not the cables. Pulling
cables will result in breaks.
Note: Avoid connecting and disconnecting of connectors all if possible. Doing so may result in weak contact.
Note: Be sure to use the adapter exclusively designed for the scanner.
3
Page 13
(
)
Using the PS/2 keyboard interface
Note: Before proceeding to the connection procedure, be sure to switch off your computer.
(1) The PS/2 keyboard interface cable is a Y-letter type having two connectors. Connect them to your computer and
its keyboard as shown below.
For a notebook or other computer with no external keyboard connected, simply plug the cable into the external
keyboard connector.
Scanner
Connector for computer
male
PS/2 keyboard interface cable
Connector for keyboard (female)
(2) When you use the scanner first after delivery, change the interface setting to the PS/2 keyboard interface from the
RS-232C interface (factory default) by scanning the following bar code:
PS/2 keyboard interface
(3) Select the keyboard connection type from "With external keyboard (default)," "Without external keyboard," and
"With external numeric keypad" by using the bar-coded parameter menu in Chapter 12. (For details about the
keyboard connection type, refer to page 56)
(4) If you have modified the scanner settings in step (2) or (3) above, restart your computer.
Note: Do not input data from the scanner and keyboard simultaneously. The scanner cannot accept such entry normally.
4
Page 14
Chapter 3 Reading Bar Codes
(1) Press the trigger switch to turn on the illumination LED and prepare the scanner for reading.
Note: This step is not required for the continuous reading and auto sensing modes (see Section 5.3).
(2) Align the scanner over the center of the target bar code so that the illumination longitudinally scans the center of
the bar code.
Scan distance
GT10B-SM/GT11B-SM: 7 cm (2.76")
GT10B-LM: 18 cm (7.09")
Indicator LED
Illumination
Effective
scan range
Trigger switch
(3) Wait for the indicator LED to turn blue and the beeper to sound, indicating a successful read.
Note: The effective scan range is less than the full illumination range.
The effective scan range depends on the model and the distance from the scanner to the target.
GT10B-SM/GT11B-SM: approximately 10 cm (3.94") for a scan distance of 7 cm (2.76")
GT10B-LM: approximately 17 cm (6.69") for a scan distance of 18 cm (7.09")
Note: Having more than one bar code within the field of view either causes the read to fail or produces multiple
input.
Note: Bar code orientation (right side up or upside down) does not matter as long as the margins are well within
the field of view.
Note: It is sometimes necessary to vary the scanning angle or distance to eliminate reflections of the illumination
and ambient light off highly reflective labels.
Scanning modes
Regular read mode
Successful completion of read-in produces data transfer.
Data verification mode The scanner transfers only data that matches a predefined list of acceptable bar codes.
(Refer to Chapter 7 for details.)
Speed-/depth-priority scanning
Speed-
priority The scanner gives priority to reducing the time spent decoding bar code data.
Depth-priority The scanner gives priority to expanding the scan range.
For details, refer to Appendix 1.
5
Page 15
Reading RSS-14 Stacked and RSS-14 Stacked Omnidirectional symbols
The scanner reads RSS-14 Stacked and RSS-14 Stacked Omnidirectional symbols in two steps. In the 1st step, it scans
either one of the 1st and 2nd rows of the target symbol and accumulates the data in itself. In the 2nd step, it scans the
remaining row, edits the 1st and 2nd row data read, and then sends the data to the host.
To inform the user that the 1st or 2nd row data has accumulated in the scanner, the scanner emits a one-shot beep by
default. Upon completion of a successful read of the remaining row, the scanner emits a short beep just as upon
completion of a read of any other type of bar code.
To discard the accumulated data halfway through a sequence of scanning, turn off the illumination LED. In the
continuous reading mode or auto sensing mode, however, move the illumination away from the target symbol.
6
Page 16
Chapter 4 Customizing the Scanner
You can customize the scanner by modifying communications, bar code type, and other scanner parameters with the
bar-coded parameter menu or the configuration software ScannerSetting*. These parameters retain their settings even
when the power is off.
(1) Scanning parameter setting bar codes from the bar-coded parameter menu
(The bar-coded parameter menu is given in Chapter 12.)
(2) Using the configuration software (ScannerSetting)*
bar code printouts for read by scanners in the field.)
* Registered users can download the configuration software (ScannerSetting)
section on the Denso Wave website at no extra charge.
For further details on QBdirect or to register, visit the following URL.
http://www.qbdirect.net
in your computer. (The software also offers batch-process
by pressing the trigger switch.
from QBdirect, their customer support
7
Page 17
Chapter 5 Scanning Control
Two types of scanning controls are available--Trigger switch control and Software control.
Trigger switch control: Pressing the trigger switch readies the scanner for scanning.
Software control: Instead of pressing the trigger switch, you send control commands from the host computer via the
RS-232C interface to ready the scanner for scanning or put the scanner on standby.
5.1 Trigger Switch Control
Pressing the trigger switch turns on the illumination LED and readies the scanner for scanning. The scanner supports
the following five trigger switch operating modes. Select the one that best meets your needs using the bar-coded
parameter menu or the configuration software (ScannerSetting).
(1) Auto-off mode 1
Holding down the trigger switch lights the illumination LED for the specified period (selectable from 1 to 5 seconds in
one second increments with the configuration software (ScannerSetting)), during which the scanner is ready to scan.
When a bar code is read successfully or the specified period has elapsed, the illumination LED goes off and the
scanner switches to standby.
(2) Auto-off mode 2
If you press the trigger switch, the illumination LED lights for approx. 5 seconds during which the scanner is ready to
scan, regardless of whether a bar code is read successfully or the trigger switch is released.
After a bar code is read successfully, the ready-to-scan state further continues for approx. 5 seconds.
If the scanner is left without scanning operation for approx. 5 seconds, it turns off the illumination LED and switches
to standby.
(3) Momentary
Only while you hold down the trigger switch, the illumination LED lights and the scanner is ready to scan.
When you release the trigger switch or a bar code is read successfully, the illumination LED goes off and the scanner
switches to standby.
(4) Momentary
Only while you hold down the trigger switch, the illumination LED lights and the scanner is ready to scan, regardless
of whether a bar code is read successfully.
When you release the trigger switch, the illumination LED goes off and the scanner switches to standby.
(5) Continuous reading mode
When you turn the scanner on, the scanner lights the illumination LED and becomes ready to scan. The scanner
ignores all trigger switch input.
Note:When you are setting parameters using the bar-coded parameter menu, the scanner is always in the
momentary switching mode 1 regardless of the trigger switch operating mode selected.
Note: The trigger switch is disabled as long as the scan lock (see Section 7.1.3) is in effect in the data verification
mode.
switching mode 1 (Factory default)
switching mode 2
8
Page 18
5.2 Software Control
You can control the scanner by sending scanning control commands from the host computer via the RS-232C interface,
instead of pressing the trigger switch.
Scanning control commands include R, READON, LON, RC, Z, READOFF and LOFF and they are restricted by the
trigger switch operating mode, as listed below. In momentary switching mode 1, for example, the RC command is
invalid. In auto-off mode 2 and momentary switching mode 2, all of these commands are invalid.
(√ : Command valid)
Trigger switch operating modes
Commands Description
R,
READON,
LON
RC
READOFF,
LOFF
Ready-to-scan commands
Upon receipt of one of these commands,
the scanner turns on the illumination
LED and becomes ready to scan.
Standby commands
Z,
Upon receipt of one of these commands,
the scanner turns off the illumination
LED and goes on standby.
Auto-off
mode 1
Auto-off
mode 2
√ -- √ -- √
-- -- -- -- √
-- -- √ -- √
Each of these commands should be enclosed with a header and terminator for transmission according to the
communications conditions of the scanner.
Note: When the scanner is ready to scan with an R, READON or LON command, pressing the trigger switch
cancels the command control, producing the operation specified for the trigger switch.
Notification of a scanning failure
If the scanner fails to read a bar code and switches to standby in auto-off mode 1 or momentary switching mode 1, it
can send the following two types of notification data (cancel or error) to the host computer.
- CAN (18h)
- ERROR (with header and terminator)
Control scheme
(1) Auto-off mode 1 or momentary switching mode 1
Successful read
Command input (RxD)
Bar code
Illumination LEDs
Data output (TxD)
Ready-to-scan command
Momentary
switching
mode 1
Bar code data
Momentary
switching
mode 2
Continuous
reading mode
9
Page 19
Failure read
• Auto-off mode 1
Command input (RxD)
Bar code
Illumination LEDs
Data output (TxD)
Ready-to-scan command
1 to 5 sec.
Failure notification
• Momentary switching mode 1
Command input (RxD)
Bar code
Illumination LEDs
Data output (TxD)
Ready-to-scan command
Standby command
Failure notification
(2) Continuous reading mode
Switching to the ready-to-scan state with an R, READON or LON command
Command input (RxD)
Bar code
Illumination LEDs
Data output (TxD)
Standby command
Bar code data
Switching to the ready-to-scan state with an RC command
Command input (RxD)
Bar code
Illumination LEDs
Data output (TxD)
Standby command
Bar code data
10
Ready-to-scan command
Ready-to-scan command
Page 20
5.3 Auto Sensing Mode—Automatic Detection of Labels
In auto sensing mode, bringing a bar code label within the scan range of the reading window turns on the illumination
LED and starts the scanner reading the bar code. No trigger switch operation is required. Use this mode when the
scanner is stationary to a stand and a bar code label is moved.
The illumination LED comes on when you bring a bar code label within the designated range or move a bar code label
within the same range. The LED goes off when a bar code label is moved away from the range or stays within the
range without move for approx. 5 seconds.
The scanner offers a choice of three sensitivity levels for responding to bar codes. Switch to a higher sensitivity level
if the illumination LED will not come on when a bar code is brought into the range, for example.
Note: Even if you do not bring a bar code label within the scan range, the illumination LED may come on when
the ambient level of light changes or any shadows move within the scan range.
Note: Given below is a guide for scanning EAN-13 symbols in auto sensing mode under these conditions: At the
center of the effective scan range and at the ambient illuminance of 500 lux or higher.
GT10B-SM/GT11B-SM: Scan distance of approx. 21 cm (8.27")
GT10B-LM: Scan distance of approx. 40 cm (15.75")
Note: It is sometimes necessary to vary the scanning angle or distance to eliminate reflections of the illumination
and ambient light off highly reflective labels.
11
Page 21
Chapter 6 Magic Key Control
The magic key can act as an auxiliary key for scanning or data transfer. You can assign any of the following five
functions or no function at all to the magic key. Select the function that best meets your needs using the bar-coded
parameter menu or the configuration software (ScannerSetting).
(1) Illumination switching function
Pressing the magic key alternately turns the illumination LED on and off. Note, however, that turning on the LED
does not make the scanner ready to scan. That requires pressing the trigger switch.
The scanner automatically turns off the illumination LED after approximately 3 minutes without detecting completion
of a scanning operation.
The scanner ignores magic key input if the trigger switch operating mode is continuous read or auto sensing mode.
Completion of scanning
The illumination
LED comes on.
Press the magic key.
Press the trigger switch.
(2) Data retransfer function
Pressing the magic key resends the preceding data. Note, however, that the scanner ignores such requests if there is no
such data available--that is, you have turned off the power since the last read operation.
(3) Specific character transfer function
Pressing the magic key transfers a character string (max. 10 bytes) specified with the configuration software
(ScannerSetting).
(4) Ready/standby switching function
When the trigger switch is in the continuous reading mode, pressing the magic key switches the scanner between
ready-to-scan (illumination LED ON) and standby (illumination LED OFF).
(5) Auto sensing mode switching function
Pressing the magic key toggles between the auto sensing mode and the currently selected trigger switch operating
mode.
(6) Continuous reading mode switching function
Pressing the magic key toggles between the continuous reading mode and the currently selected trigger switch
operating mode.
(7) No function (Disable)
If no function has been assigned to the magic key, pressing the key produces no operation.
12
Page 22
The following table lists the relationship between the magic key functions and trigger switch operating modes. (It
applies to both the regular read mode and data verification mode.) The "--" indicates that the scanner ignores the
magic key functions assigned. In auto-off mode 1, for example, the ready/standby switching function is ignored.
Trigger switch operating modes
Auto-off mode 1 Auto-off mode
Magic key functions
Illumination switching
function
Data retransfer function √ √ √ √ √ √
Specific character transfer
function
Ready/standby switching
function
Auto sensing mode
switching function
Continuous reading mode
switching function
No function √ √ √ √ √ √
√ √ √ √ -- --
√ √ √ √ √ √
-- -- -- -- √ --
√ √ √ √ √ --
√ √ √ √ -- √
2
Momentary
switching
mode 1
Momentary
switching
mode 2
Continuous
reading mode
Auto sensing
mode
13
Page 23
r
r
Chapter 7 Scanning Functions
7.1 Data Verification Mode
The data verification mode verifies the bar code data read against the master data stored in the scanner and reports the
match status with data output.
Data verification read is available in two types--"n-point verification" and "2-point verification."
Selecting the n-point verification requires registering master data only one time for 1:n verification. The scanner
verifies all bar code data read after registration against the master data.
The 2-point verification refers to 1:1 verification. Selecting it requires registering master data each time preceding bar
code scanning. After registration of master data, the scanner reads a bar code, verifies the bar code data read against
the master data and then becomes ready to register new master data. This way, the 2-point verification read alternately
repeats master data registration and bar code scanning.
The master data registration procedure is different in n-point and 2-point verification reads. (See Section 7.1.1.)
The verification parameters can be specified using the bar-coded parameter menu or configuration software
(ScannerSetting). After specifying them, scan a master bar code, and the scanner becomes capable of data verification
read.
7.1.1 Verification setup procedure
e
n-point v
After one-time registration of master data, the scanner verifies all bar code data read after registration against the
master data.
- Switch to the data verification mode.
- Specify the verification parameters
(verification conditions and result
output ways).
rification read
↓
Scan a master bar code to register.
(Registration of master data)
↓
Scan bar codes.
Use the bar-coded parameter menu or configuration software.
The indicator LED flashes in red
registered in the scanner.
Hold down the magic key to light the indicator LED in green
magic key held down and press the trigger switch to scan a master ba
code.
After registration of master data, the indicator LED goes off
Use the scanner to scan a target bar code. The scanner verifies the ba
code read against the master data registered and then outputs the result.
After a successful read, the indicator LED lights in blue
, indicating that no master bar code is
. Keep the
.
.
Note: For what clears the registered master data, see the next page.
14
Page 24
r
2-point verification read
After registration of master data, the scanner reads a bar code, verifies the bar code data read against the master data
and then becomes ready to register new master data.
- Switch to the data verification mode.
- Specify the verification parameters
(verification conditions, result output
ways, and verification retry after
mismatch*).
↓
Scan a master bar code to register.
(Registration of master data)
↓
Scan bar codes.
*Verification retry after mismatch in 2-point verification
The 2-point verification read provides the "Verification retry after mismatch" option that retries verification against
the same master data. Enabling this option readies the scanner not for registering new master data but for reading a bar
code again if the verification result is a mismatch.
Disabling this option readies the scanner for registering new master data after bar code reading, no matter what the
verification result is.
Note: Any of the following events clears the master data stored in the scanner.
- Customizing the scanner by modifying the parameters with the configuration software (ScannerSetting) or
batch-process bar code symbols.
- Modifying the "verification start position in data verification mode" or "number of characters to verify, starting
from the verification start position" setting with the bar-coded parameter menu.
- The scanner power is turned off due to the removal/replacement of the battery cartridge or the low battery.
Use the bar-coded parameter menu or configuration software.
The indicator LED lights in green
to register master data.
Press the trigger switch to scan a master bar code.
After registration of master data, the indicator LED goes off
Use the scanner to scan a target bar code. The scanner verifies the ba
code read against the master data registered and then outputs the
result.
After a successful read, the indicator LED lights in green
that the scanner is ready to register new master data.
, indicating that the scanner is ready
.
, indicating
15
Page 25
7.1.2 Verification conditions
You can set a verification starting position and the number of characters to check.
- Starting position: The choices are 1st through 7th characters.
- Number of characters: The choices are 1 through 7 and everything following the starting position (up to a
maximum of 32 characters).
For example, you can specify all characters or particular characters of bar code data to check as shown below.
Master data
Verification conditions: All characters to check
To check all characters as underlined at left, for example, set the following:
12345601
Bar code data readable
12345601
- Starting position: 1st character
- Number of characters: All characters
Max. 32 bytes of bar code data can be verified.
Master data
Verification conditions: Particular characters to check
To check particular characters as underlined at left, for example, set the
following:
- Starting position: 3rd character
- Number of characters: 2 characters
5601
1234
Bar code data readable
7803
0134
Note: If the bar code type (symbology) of data read is different from that of the master data, the verification results
in a mismatch even if those data matches.
16
Page 26
7.1.3 Verification result output
(1) Report of match/mismatch status
You can select any of the following report types by using the bar-coded parameter menu or configuration software
(ScannerSetting). Selecting "Disable transmission" reports nothing.
Setting If there is a match: If there is a mismatch:
1 Disable bar code data transmission. Disable bar code data transmission.
2 Enable bar code data transmission. Disable bar code data transmission.
3 Enable bar code data transmission. Enable NG transmission.
4 Enable OK transmission. Enable NG transmission.
(2) Beeper, indicator LED, and vibrator
You can check whether the verification result is a match or mismatch, with the beeper, indicator LED and vibrator.
When the beeper, indicator LED and vibrator are enabled, they act as listed below.
Beeper Indicator LED
If there is a match: Emits a short beep. Lights in blue. Operates. --
If there is a mismatch: Emits a long beep. Lights in red. -- Operates.
"OK" vibrations"NG" vibrations
Vibrator
(3) Scan lock
The scan lock function locks the scanner on standby if the verification result is a mismatch. You can enable or disable
this function with the bar-coded parameter menu or configuration software (ScannerSetting).
Once the scanner is locked, it switches to standby regardless of the current trigger switch control selected. The scanner
remains on standby even if the trigger switch is pressed or a ready-to-scan command (R, READON or LON) is
received.
Pressing the magic key or turning off the power releases the scan lock.
7.1.4 Output of the master data registered
utput master data" bar code given below lets the scanner output the master data registered in the
Scanning the "
O
verification setup procedure.
Note: In the 2-point verification read, the scanner cannot read this bar code, so it cannot output master data.
Output master data
17
Page 27
7.2 Specifying the Numbers of Digits of Standard 2of5 and Interleaved 2of5 Symbols to
Read, by Scanning Bar Codes
You can specify the numbers of digits of Standard 2of5 and Interleaved 2of5 symbols to read.
First enable the parameter "specification of the number of digits by bar code scanning" by using the bar-coded
parameter menu or configuration software. Then scan Standard 2of5 or Interleaved 2of5 symbols. The numbers of
digits of symbols scanned first and second (after you enable the parameter or turn the scanner on) will be registered in
the memory.
After the registration, the scanner can read only Standard 2of5 or Interleaved 2of5 symbols having either of those
specified numbers of digits.
(Example)
123457
1234567895
987653
98765430
Specifying the number of digits readable
First scan: 6-digit Interleaved 2of5 symbol
→ Just the bar code type and the number of digits will be stored in the scanner.
The code data will be sent.
Second scan: 10-digit Interleaved 2of5 symbol
→ Just the bar code type and the number of digits will be stored in the scanner.
The code data will be sent.
After that, 6-digit and 10-digit Interleaved 2of5 symbols only can be read.
Scanning after setting the number of digits readable
6-digit Interleaved 2of5 bar code
→ This bar code can be read.
8-digit Interleaved 2of5 bar code
→ This bar code cannot be read.
18
Page 28
Chapter 8 Data Editing
The scanner can edit bar code data read in the format specified with the configuration software (ScannerSetting) and
transfer it to the host computer.
The format specification parameters retain their settings until the configuration software (ScannerSetting) or
bar-coded parameter menu sets "All defaults."
8.1 Extracting Data
The scanner extracts a part of bar code data read according to the extraction conditions--"Specified number of digits
from head position," "Specified number of digits from tail position," "From the specified start to tail positions," and
"From the specified start to end positions.
The following sample bar code and scanner settings output data as listed below depending upon the extraction
conditions.
- Bar code sample
Bar code type: Code 128, Data read: 1234567890
- Scanner settings
Header: STX, Terminator: ETX, Prefix/Suffix: None, Code ID mark: Type 1,
Transmission of number of digits: 2 digits
(1) Extracting the specified number of digits of data from head position
The number of digits must be within the range from 1 to 99. If the number of digits in bar code data read is less than
the one specified, an error occurs.
(Example)
Number of digits Output data
(2) Extracting the specified number of digits of data from tail position
The number of digits must be within the range from 1 to 99. For example, three digits of data from the tail position
contain "890." If the number of digits in bar code data read is less than the one specified, an error occurs.
(Example)
Number of digits Output data
3 digits [STX]K03123[ETX]
8 digits [STX]K0812345678[ETX]
12 digits Error
3 digits [STX]K03890[ETX]
8 digits [STX]K0834567890[ETX]
12 digits Error
19
Page 29
(3) Extracting data from the specified start to tail positions
The start position must be within the range from the 2nd to 99th digits. If the number of digits in bar code data read
does not reach the specified start position, an error occurs.
(Example)
Start position Output data
3rd position [STX]K0834567890[ETX]
8th position [STX]K03890[ETX]
12th position Error
(4) Extracting data from the specified start to end positions
The start and end positions must be within the range from 2nd to 99th digits each. The end position must be equal to
or greater than the start position. If the number of digits in bar code data read does not reach the specified start or end
position, an error occurs.
(Example)
Start position End position Output data
3rd position 7th position [STX]K0534567[ETX]
8th position 10th position [STX]K03890[ETX]
10th position 11th position Error
8.2 Substituting Data
The scanner searches the specified string (max. 10 characters long) in bar code data read, starting from the specified
start position (the head to the 10th position) to the end. If the bar code data contains the specified string, the scanner
substitutes it with the specified substitution string (max. 3 characters long) and transfers it according to the
substitution conditions--"Transferring the substituted element string only," "Transferring the substituted element string
+ bar code data," and "Transferring the substituted full string."
The following sample bar code and scanner settings output data as listed below depending upon the substitution
conditions.
- Bar code sample
Bar code type: Code 128, Data read: 1234567890
- Scanner settings
Header: STX, Terminator: ETX, Prefix/Suffix: None, Code ID mark: Type 1,
Transmission of number of digits: 2 digits
(1) Transferring the substituted element string only
If the bar code data contains the specified substitution string within the specified search area, the scanner transfers the
substituted element string only.
(Example)
Search start position Search string Substitution stringOutput data
2nd position 456 A [STX]K01A[ETX]
5th position 890 XYZ [STX]K03XYZ[ETX]
9th position 890 XYZ Error
20
Page 30
(2) Transferring the substituted element string
If the bar code data contains the specified substitution string within the specified search area, the scanner transfers the
substituted element string followed by the bar code data read.
(Example)
Search start position Search string Substitution stringOutput data
2nd position 456 A [STX]K11A1234567890[ETX]
5th position 890 XYZ [STX]K13XYZ1234567890[ETX]
9th position 890 XYZ Error
(3) Transferring the substituted full string
If the bar code data contains the specified substitution string within the specified search area, the scanner substitutes
the search string with the substitution string and transfers the full string. If it contains two or more search strings, only
the first one is substituted.
(Example)
Search start position Search string Substitution stringOutput data
2nd position 456 A [STX]K08123A7890[ETX]
5th position 890 XYZ [STX]K101234567XYZ[ETX]
9th position 890 XYZ Error
8.3 Blocksorting Data
The scanner splits bar code data read into a maximum of 5 blocks at the specified split positions and sorts those blocks
in the specified order.
The split position must be specified by the number of digits from the head of bar code data. Specifying the number of
digits exceeding that in the bar code data results in an error.
The following sample bar code and scanner settings output data as listed below depending upon the sorting conditions.
- Bar code sample
Bar code type: Code 128, Data read: 1234567890
- Scanner settings
Header: STX, Terminator: ETX, Prefix/Suffix: None, Code ID mark: Type 1,
Transmission of number of digits: 2 digits
(Example)
Split position Order of blocks Output data
3rd position, 8th position Block 2, 1, 3 [STX]K104567812390[ETX]
3rd position, 8th position Block 1, 3 [STX]K0512390[ETX]
21
Page 31
8.4 Parenthesizing AIs (Application Identifier) in EAN-128 Data
The scanner parenthesizes all AIs contained in EAN-128 data read and transfers the data. (For the definition of AIs,
see Section 8.6.3.)
The following sample bar code and scanner settings output data with AIs parenthesized as listed below.
- Bar code sample
Bar code type: EAN-128, Data read: 0194901234567894110308081303081017040208
- Scanner settings
Header: STX, Terminator: ETX, Prefix/Suffix: None, Code ID mark: Type 1,
8.5 Extracting AI (Application Identifier)-Prefixed Strings from EAN-128 Data
The scanner extracts element strings prefixed with the specified AIs (up to three types of AIs) and separates them with
the specified delimiters (selectable from headers/terminators, commas, and tabs) instead of AIs to transfer them. (For
the definition of AIs, see Section 8.6.3.)
The following sample bar code and scanner settings output data as listed below depending upon the AI conditions.
- Bar code sample
Bar code type: EAN-128, Data read: (01)94901234567894(11)030808(13)030810(17)040208
- Scanner settings
Header: STX, Terminator: ETX, Prefix/Suffix: None, Code ID mark: Type 1,
Transmission of number of digits: 2 digits
(1) Header/terminator
Specifying a header/terminator as a delimiter prefixes a header and suffixes a terminator to each element string
separated.
A prefix, suffix, the number of digits, and code ID mark can be also added to each element string if their transmissions
are enabled. The number of digits is that in each element string after editing.
Specifying a comma as a delimiter outputs comma-delimited data. No comma follows the tail of the data.
A header and terminator are added to the full string. A prefix, suffix, the number of digits, and code ID mark can be
also added to the full string if their transmissions are enabled. The number of digits is that in the full string after
editing.
(Example)
AI1=01, AI2=17 [STX]W2194901234567894,040208[ETX]
AIs specified Output data
AIs specified Output data
22
Page 32
(3) Tab (ASCII 09h <HT>)
Specifying a tab as a delimiter outputs tab-delimited data. No tab follows the tail of the data.
A header and terminator are added to the full string. A prefix, suffix, the number of digits, and code ID mark can be
also added to the full string if their transmissions are enabled.
Scanners equipped with PS/2 keyboard interfaces also transfer ASCII 09h for tab, instead of TAB key.
390n n4+n..15 Amount Payable--Single Monetary Area (****)
391n n4+n3+n..15 Amount Payable and ISO Currency Code (****)
392n n4+n..15
393n n4+n3+n..15
Amount Payable for a Variable Measure Trade Item--Single Monetary
Area (****)
Amount Payable for a Variable Measure Trade Item and ISO Currency
Code (****)
400 n3+an..30 Customer's Purchase Order Number
401 n3+an..30 Consignment Number
402 n3+n17 Shipment Identification Number
403 n3+an..30 Routing Code
410 n3+n13 Ship to (Deliver to) EAN.UCC Global Location Number
411 n3+n13 Bill to (Invoice to) EAN.UCC Global Location Number
412 n3+n13 Purchased from EAN.UCC Global Location Number
413 n3+n13 Ship for (Deliver for) EAN.UCC Global Location Number
26
Page 36
AI Format Description
414 n3+n13
Identification of a Physical Location--EAN.UCC Global Location
Number
415 n3+n13 EAN.UCC Global Location Number of the Invoicing Party
420 n3+an..20 Ship to (Deliver to) Postal Code Within a Single Postal Authority
421 n3+n3+n..9
Ship to (Deliver to) Postal Code with Three-Digit ISO Country Code
Prefix
422 n3+n3 Country of Origin of a Trade Item
423 n3+n3+n..12 Country of Initial Processing
424 n3+n3 Country of Processing
425 n3+n3 Country of Disassembly
426 n3+n3 Country of Final Processing
43 n2+n4+n7+an6..10+n1 Carrier Assigned Tracking Number
7001 n4+n13 NATO Stock Number (NSN)
7002 n4+an..30 UN/ECE Meat Carcasses and Cuts Classification
7030 n4+n3+an..27
7031 n4+n3+an..27
703n n4+n3+an..27
Approval Number of Processor with Three-Digit ISO Country Code,
Butchery
Approval Number of Processor with Three-Digit ISO Country Code, 1st
Processing Place
Approval Number of Processor with Three-Digit ISO Country Code,
2nd to 9th Processing Places
8001 n4+n14 Roll Products--Width, Length, Core Diameter, Direction, and Splices
8002 n4+an..20 Cellular Mobile Telephone Identifier
8003 n4+n14+an..16 EAN.UCC Global Returnable Asset Identifier (GRAI)
8004 n4+an..30 EAN.UCC Global Individual Asset Identifier (GIAI)
8005 n4+n6 Price Per Unit of Measure
8006 n4+n14+n2+n2 Identification of the Component of a Trade Item
8007 n4+an..30 International Bank Account Number (IBAN)
8008 n4+n8+n..4 Date and Time of Production (YYMMDDHHMMSS)
8018 n4+n18 EAN.UCC Global Service Relation Number (GSRN)
8020 n4+an..25 Payment Slip Reference Number
8100 n4+n1+n5
8101 n4+n1+n5+n4
8102 n4+n1+n1
UPC Coupon Extended Code--Number System Character and Offer
Code
UPC Coupon Extended Code--Number System Character, Offer Code,
and End of Offer Code
UPC Coupon Extended Code--Number System Character Preceded by
Zero
90 N2+an..30 FACT Data Identifiers
91 N2+an..30 Company Internal Information--Company
92 N2+an..30 Company Internal Information--Company
93 N2+an..30 Company Internal Information--Company
27
Page 37
AI Format Description
94 N2+an..30 Company Internal Information--Company
95 N2+an..30 Company Internal Information--Carrier
96 N2+an..30 Company Internal Information--Carrier
97 N2+an..30 Company Internal Information--Company
98 N2+an..30 Company Internal Information--Company
99 N2+an..30 Company Internal Information
(*) To indicate only year and month, DD must be FILLED with "00."
(**) n indicates the length of data.
(***) n indicates the decimal point position.
(****) n indicates the number of digits after decimal point
Note 1: The EAN-128 AIs are compliant with the General EAN.UCC Specifications v. 6.0.
Note 2: If the specified AI is variable in length and the number of digits in data read is less than the maximum number
of digits defined for the AI, the output contains a GS (1Dh) in the data read.
28
Page 38
Chapter 9 Beeper, Indicator LED and Vibrator
9.1 Beeper
(1) Beeping
The scanner emits a short, long, one-shot, or intermittent beep to indicate the scanner status as described below. The
intermittent and one-shot beeps apply when the scanner reads an RSS-14 Stacked or RSS-14 Stacked Omnidirectional
symbol.
The beeper can be disabled with the bar-coded parameter menu or configuration software (ScannerSetting); however,
in some cases it sounds regardless of the beeper setting. For details, see the next page.
Note: Whether to enable or disable the beeper when the scanner reads RSS-14 Stacked or RSS-14 Stacked
Omnidirectional symbols can be selected with the "Beeper when reading RSS-14 Stacked/RSS-14 Stacked
Omnidirectional" bar code on the bar-coded parameter menu. The "Beeper" bar code for other bar codes has no effect
on RSS-14 Stacked or RSS-14 Stacked Omnidirectional symbols.
1
A short beep (60, 80, or 120 ms selectable*
• a read of a bar code is successfully complete,
• master data registration is successfully complete in the verification setup procedure,
• bar code data read matches the master data in the data verification mode,
• data retransfer or specific character transfer with the magic key is complete,
• bar code data read in the specified data editing matches the editing conditions,
• the scanner has read a parameter setting bar code from the bar-coded parameter menu (given in Chapter 12), or
• the scanner has read the "DATA" bar code out of batch-process bar code symbols generated with the configuration
software.
A short beep of 60 ms when:
• the "Start setting" or "End setting" bar code is read from the bar-coded parameter menu (given in Chapter 12),
• the scanner has read the "START" or "END" bar code out of batch-process bar code symbols generated with the
configuration software,
• the configuration software starts up or accepts new setting, or
• the setting cannot be made because the "START" barcode from a batch-process barcode printed with a version of the
configuration software that does not match the scanner firmware was scanned.
) when:
A long beep of 180 ms when:
• parameter setting with the bar-coded parameter menu (given in Chapter 12) has failed.
A long beep of 480 ms when:
• a master bar code has the wrong number of digits during registration of master data,
• bar code data read does not match the master data in the data verification mode,
• bar code data read in the specified data editing does not match the editing conditions, resulting in no transfer,
• a transmission error or timeout has occurred during communication with the configuration software
(ScannerSetting),
• a communications error has occurred,
• the previously sent data is not available at the time of data retransfer (using the magic key),
• three minutes have elapsed without scanning any parameter setting bar code from the bar-coded parameter menu
(given in Chapter 12) in the parameter setting procedure, or
• there is a possibility of an abnormal setting because the "END" barcode from a batch-process barcode printed with a
version of the configuration software that does not match the scanner firmware was scanned.
29
Page 39
One-shot beep*2 (40 ms) or intermittent beep*2 (at 60 ms intervals) when:
• either one of the 1st and 2nd rows of an RSS-14 Stacked or RSS-14 Stacked Omnidirectional symbol is read.
(Selecting an intermittent beep continues to beep as long as either one of the 1st and 2nd rows is left unread.)
(Upon completion of a read, the beeper emits a short beep*
1
The configuration software (ScannerSetting) provides three choices for the beeping time of a short beep--60, 80,
*
1
.)
and 120 ms.
2
The bar-coded parameter menu or the configuration software (ScannerSetting) provides three choices for the
*
beeper type in reading RSS-14 Stacked and RSS-14 Stacked Omnidirectional symbols--One-shot beep, intermittent
beep, and disabled.
The beeper can be disabled with the bar-coded parameter menu or configuration software (ScannerSetting). In any of
the following cases, however, the beeper sounds regardless of the current beeper setting:
- When the scanner is being customized with the bar-coded parameter menu (Chapter 12).
- When the configuration software (ScannerSetting) starts up or accepts any new setting.
- When a batch-process bar code symbol is read.
- When the scanner has failed to save the parameter settings.
(2) Beeper volume
You can adjust the beeper volume to three level--High, medium and low, by using the bar-coded parameter menu or
the configuration software (ScannerSetting). The factory default is High.
Each time the "Beeper volume" bar code is read, the beeper volume cycles as shown below.
High
MediumLow
Turning the scanner power off does not affect this setting..
(3) Beeper frequency
The configuration software (ScannerSetting) provides the following three choices for beeper frequency.
- "Low: 2.0 kHz"
- "Medium: 4.0 kHz"
- "High: 4.3 kHz"
The factory default is Medium (4.0 kHz).
Turning the scanner power off does not affect this setting.
(4) Trigger timing for the reading completion beeper and indicator LED
The configuration software (ScannerSetting) provides the following two trigger timing choices for the reading
completion beeper and indicator LED (blue).
- "Before data transmission": The trigger timing is when bar code scanning has been completed, regardless of
whether the bar code data is normally transferred.
- "After data transmission": The trigger timing is when bar code scanning has been completed and the data has been
normally transferred.
The factory default is "Before data transmission."
30
Page 40
9.2 Indicator LED
The indicator LED lights or flashes in blue, green, red or orange to indicate the scanner status as described below.
Lights in blue when:
• a read of a bar code is successfully complete (Note that when the auto sensing mode switching function* is enabled,
the indicator LED lights in green.),
• the "Start setting" or "End setting" bar code symbol is read from the bar-coded parameter menu (given in Chapter
12),
• bar code data read matches the master data in the data verification mode,
• the auto sensing mode switching function* has switched the scanner to the currently selected trigger switch
operating mode, or
• switched to the trigger switch operating mode using the continuous reading mode switching function.
Lights in green when:
• a processing started by magic key control has completed,
• the scanner is ready to register master data in the data verification mode, or
• the scanner has read a bar code (except a master bar code for data verification) successfully with the auto sensing
mode switching function* being enabled.
Lights in red when:
• a check digit error has occurred,
• a bar code read has the wrong number of digits,
• bar code data read does not match the master data in the data verification mode,
• a master bar code read has the wrong number of digits in registration of master data,
• the data retransfer function failed to transfer data, or
• an editing error has occurred in the specified data editing, resulting in no transfer.
Flashes red when:
• no master data has been registered in the data verification mode.
Lights in orange when:
• the auto sensing mode switching function* has switched the scanner to the auto sensing mode, or
• switched to the continuous reading mode using the continuous reading mode switching function.
The indicator LED can be disabled with the bar-coded parameter menu or configuration software (ScannerSetting). In
any of the following cases, however, the indicator LED comes on regardless of the current LED setting:
- When the scanner is being customized with the bar-coded parameter menu (Chapter 12).
- When the configuration software (ScannerSetting) starts up or accepts any new setting.
- When a batch-process bar code symbol is read.
- When a master bar code is being registered or the registration is complete.
- When any error has occurred during entry of a master bar code.
- When the verification result is a mismatch, the scanner is locked, or no master data has been registered in the data
verification mode.
- When data retransfer with the magic key is complete or the previously sent data is not available at the time of data
retransfer.
- When specific character transfer with the magic key is complete.
- When a hardware error has occurred.
- When the scanner has failed to save setting.
*For the auto sensing mode switching function assigned to the magic key, refer to Chapter 6.
31
Page 41
9.3 Vibrator
The bar-coded parameter menu and configuration software (ScannerSetting) provide three configuration choices:
indicating successful scanning (OK), indicating an error (NG), and disabled.
"OK" vibrations: The vibrator operates to indicate any of the following OK conditions.
• Successful transmission of the bar code data just read
• In data verification mode, successful registration of master data
• In the data verification mode, a match between the bar code data just read and master data registered
• End of data transmission started by the retransfer or specific character transfer function
• Scanning of "Start setting," "End setting," or parameter setting bar code from the bar-coded parameter menu
(Chapter 12)
• Start or end of parameter setting with the configuration software (ScannerSetting)
• Scanning of a batch-process bar code symbol generated with the configuration software (ScannerSetting)
"NG" vibrations: The vibrator operates to indicate any of the following failure conditions.
•- Wrong check digit(s) with check digits enabled
• Wrong number of digits in data for new master data registration
• In data verification mode, a mismatch between the bar code data just read and master data registered
• Editing error in the specified data editing, resulting in no transfer
• No ACK response received in the ACK/NAK mode
Note: It is recommended that the vibrator be disabled when the scanner is stationary to a stand.
32
Page 42
Chapter 10 Communication
10.1 RS-232C Interface
The scanner uses asynchronous data transmission and communicates with the connected host computer or external
equipment via the RS-232C. You may set various communications conditions using the bar-coded parameter menu or
configuration software (ScannerSetting). Bar code data read is transferred in the following format.
(1) Communications protocol
You can select either non-acknowledge mode or ACK/NAK mode.
Non-acknowledge mode (default)
If the CTS signal is at a high level (Enable transmission), the scanner transmits bar code data read.
Note: The configuration software provides CTS timeout settings from 100 ms to 9.9 s in 0.1-second increments.
ACK/NAK mode
If the CTS signal is at high level (Enable transmission), the scanner transmits bar code data read. After that, the
scanner waits for and then processes a response. If the response is an ACK, the scanner normally ends the
transmission; if it is a NAK, the scanner transmits the bar code data again.
Note: The configuration software provides independent CTS timeout and response settings from 100 ms to 9.9 s in
0.1-second increments.
(2) RTS signal control protocol
You can select either the scanner ready mode or the data ready mode.
Scanner ready mode (default)
The RTS signal goes High and stays at a high level when the scanner is ready to communicate at power on. Make sure
that the RTS signal is at a high level when transmitting a command from the host to the scanner.
Data ready mode
The RTS signal goes High before the scanner transmits data to the host and goes Low after the data transmission is
completed.
Commands can be transmitted from the host to the scanner regardless of the level of the RTS signal.
However, there is a short time when commands cannot be transmitted to the scanner after power has been turned on.
(3) CTS signal monitor
The configuration software ScannerSetting provides two choices of the CTS signal monitor--enable or disable.
Enabling the CTS signal monitor does not output data when the RTS signal at the host is disabled.
(4) Transmission speed
There are six transmission speeds available, ranging from 1200 bps to 38,400 bps (default: 9600 bps).
(5) Characters
Characters that the scanner transfers are all ASCII codes. The frame format has the following parameters.
Data bits: 7 bits or 8 bits (default)
Parity: Odd, Even, or None (default)
Stop bits: 1 bit (default) or 2 bits
33
Page 43
10.2 PS/2 Keyboard Interface
This IBM PS/2 keyboard interface uses CMOS signal levels.
(1) Keyboard connection type
Select one of the following connection types according to your connection.
Select: When the scanner is connected:
"With external keyboard" (default) Between the desktop computer and its keyboard (excluding a numeric keypad).
"Without external keyboard" To a notebook computer (without connection to the keyboard).
"With external numeric keypad" Between the computer and its numeric keypad.
(2) Caps Lock/Num Lock states of host computer
Select Caps Lock ON or OFF and Num Lock ON or OFF to match the states of the connected keyboard. (Default:
Caps Lock OFF, Num Lock ON)
(3) Keyboard type
Select the connected keyboard type. (Default: U.S. English)
(4) Data transmission interval
When the scanner reads a large volume of data in succession or it is connected to a computer whose processing speed
is low, the computer may cause a data overflow and issues an alarm error. For the solution, there are seven choices for
transmission interval, ranging from 1 ms to 100 ms. (Default: 1 ms)
10.3 Communication Format
10.3.1 Data transmission format
Select one of the following two data transmission formats.
Header
Code ID mark Prefix
Header
Prefix Code ID mark
No. of digits
n1 n2 n3 n4
No. of digits
n1 n2 n3 n4
Bar code data Suffix
Bar code data Suffix
Terminator
Terminator
(1) Header/Terminator
The following choices are available.
RS-232C interface
Header: None (default) or STX
Terminator: CR (default), LF, CR LF, ETX, or none
Note: Selecting none for a terminator automatically uses a CR terminator in the control command transmission format.
PS/2 keyboard interface
Header: None (default), TAB, ESC, ENTER or others
Terminator: None, TAB, ESC, ENTER (default) or others
Note: A user-defined header or terminator can be specified with the configuration software. It should be a maximum
of four bytes long and consist of ASCII characters (00h to 7Fh and E7h to FDh).
34
Page 44
(2) Prefix/Suffix
Each of a prefix and suffix should be a maximum of eight bytes long and consist of ASCII characters (00h to FEh).
The default is no prefix/suffix. You can specify a prefix or suffix with the configuration software (ScannerSetting).
(3) Code ID mark
This optional field specifies a code ID mark identifying a bar code symbology. Six types of system-defined code ID
marks are available as listed below. (Default: Type 1)
In addition, a user-defined code ID mark is also available for each of the bar code symbologies listed below. It should
be a maximum of two bytes long and consist of ASCII characters (00h to FEh).
You can also select whether or not to transmit the code ID mark. (Default: No transmission)
Code ID mark
Bar code symbologies
UPC-A A C A ]X0
UPC-E C E D A ]X0
EAN-13 A F B A ]E0
EAN-8 B FF A A ]E4
UPC-A with 2-digit add-on A F A ]X1 ]X3
UPC-A with 5-digit add-on A G A ]X2 ]X3
UPC-E with 2-digit add-on C E H A ]X1 ]X3
UPC-E with 5-digit add-on C E I A ]X2 ]X3
EAN-13 with 2-digit add-on A F L A ]E1 ]E3
EAN-13 with 5-digit add-on A F M A ]E2 ]E3
EAN-8 with 2-digit add-on B FF J A ]E5
EAN-8 with 5-digit add-on B FF K A ]E6
Standard 2of5 (short) H O G ]R0
Standard 2of5 (normal) H O G ]S0
Interleaved 2of5 I N F ]Im
Code 32 M X B ]X0
Code 39 M V B ]Am
Code 39 Full ASCII M W B ]Am
CODABAR (NW-7) N R C ]Fm
Code 93 L U E ]G0
Code 128 K T D ]Cm
EAN-128 W k K ]C1
MSI P Z J ]M1
Plessey T a T ]P0
RSS** R None None ]e0
* Type 5 or 6 is a code ID mark system compliant with the AIM USA "Guidelines on Symbology Identifiers." The "m" suffix
differs depending upon the data transmission format of each bar code symbology.
and RSS Limited symbologies as RSS. (The RSS Expanded and RSS Expanded Stacked symbologies are not supported by
this scanner.)
Type 1
(DENSO 1)
Type 2
(DENSO 2)
Type 3 Type 4
Type 5
(AIM)*
Type 6
(AIM Type 2)*
35
Page 45
(4) Number of digits
This optional field specifies the number of digits (2 or 4 digits) of bar code data to transmit or disables the
transmission (default). Note that UPC and EAN codes (except EAN-128) skip this field.
n1 : thousands (0 to 9)
n2 : hundreds (0 to 9)
n3 : tens (0 to 9)
n4 : units (0 to 9)
Selecting the two-digit length does not transmit n1 or n2.
(5) Bar code data
The following are the data transmission formats for bar code symbologies.
For the GTIN format conversion of UPC, EAN, Interleaved 2of5 (14-digit), RSS, and EAN-128, refer to Section
10.3.2.
UPC-A
0 Data (11-digit) C/D
You can select whether or not to transmit the padding character "0," number system character (leading "0" in 11-digit
data), and a check digit to the host.
UPC-E
When conversion to UPC-A is disabled (ZERO suppression format)
0 Data (6-digit) C/D
When conversion to UPC-A is enabled (ZERO insertion format)
0 Data (11-digit) C/D
You can select whether or not to transmit the padding character "0," number system character (leading "0" in 11-digit
data), and a check digit to the host.
The ZERO insertion format converts the data length to 11 according to the UPC standard.
EAN-13
Data (12-digit) C/D
You can select whether or not to transmit the country code and a check digit to the host and enable conversion to
ISBN/ISSN format.
Conversion, if enabled, produces ISBN/ISSN format according to the EAN standard.
EAN-8
Data (7-digit) C/D
You can select whether or not to add the five padding characters "0" (leading "0") to bring the total length to the same
as EAN-13, as well as selecting whether or not to transmit a check digit.
UPC/EAN with ADD-ON
UPC/EAN data ADD-ON data (2- or 5-digit)
Standard 2of5, Interleaved 2of5
Data C/D
The Standard 2of5 and Interleaved 2of5 symbologies may or may not contain a check digit. You can select whether or
not to check a check digit and transmit the check digit read.
(C/D: Check digit)
36
Page 46
Codabar (NW-7)
Start code Data C/D Stop code
The Codabar symbology may or may not contain a check digit. You can select whether or not to check a check digit
and transmit the check digit read. There are two check digit methods available: modulo arithmetic-16 (MOD-16) and
7-check method.
You can also select whether or not to transmit start/stop codes, as well as selecting either lowercase letters "a/b/c/d" or
uppercase letters "A/B/C/D" for start/stop codes.
Code 32
A Data (8-digit)C/D
You can select whether or not to transmit the leading "A" in Code 32 data to the host and check a check digit.
Six-digit Code 39 data is converted to the 9-digit Code 32 format and then transmitted to the host when all of the
following conditions are satisfied. Other number of digits of Code 39 data is transmitted in the original format without
conversion.
<Conversion conditions>
- "Scanning Code 39" is enabled,
- "Conversion from Code 39 to Code 32 format" is enabled,
- Code 39 data is 6 digits long,
- Code 39 consists of any of "0 to 9" and "alphabets except A, E, I and O," and
- The conversion result is within the range from 0 to 99999999 excluding a check digit.
Code 39
Start code Data C/D Stop code
The Code 39 symbology may or may not contain a check digit. You can select whether or not to check a check digit
and transmit the check digit read.
You can also select whether or not to transmit start/stop codes (which are "*") and enable conversion to Code 39
FULL ASCII or Code 32 format.
Code 93, Code 128, EAN-128
Data
When Code 128 is specified, data in the following format is regarded as an EAN-128 code.
Start code FNC1 Data C/D Stop code
You can select whether to convert an FNC1 (if contained) to GS (1Dh) and transfer or not to transfer an FNC1.
MSI, Plessey
Data C/D
(Note)
RSS
(Note) This manual collectively calls RSS-14, RSS-14 Truncated, RSS-14 Stacked, RSS-14 Stacked Omnidirectional, and
RSS Limited symbologies as RSS. (The RSS Expanded and RSS Expanded Stacked symbologies are not supported by this
scanner.)
Data
37
Page 47
10.3.2 GTIN Format Conversion
If the GTIN format conversion function is enabled, EAN-13, EAN-8, UPC-A, UPC-E and Interleaved 2of5 (14-digit)
codes can be output in GTIN format, and GTIN format RSS and EAN-128 codes can be output by EAN/JAN (product
code format).
(1) Conversion of EAN/UPC to GTIN format
If converting to GTIN format, it is possible to select from conversion to 16 digits or conversion to 14 digits, and to
select the transmitted PI from "0" to "9". Furthermore, by selecting prohibition of conversion to GTIN format, it is
possible to prohibit only the conversion of EAN/UPC codes to GTIN format.
EAN-13 (16-digit) 01 PIData (12-digit) C/D
(14-digit) PI Data (12-digit) C/D
EAN-8 (16-digit) 01 PI 00000Data (7-digit) C/D
(14-digit) PI 00000Data (7-digit) C/D
UPC-A (16-digit) 01 PI 0Data (11-digit) C/D
(14-digit) PI 0Data (11-digit) C/D
UPC-E (16-digit) 01 PI 0Data (11-digit) C/D
(14-digit) PI 0Data (11-digit) C/D
EAN-13 with add-on (16-digit) 01 PI 0Data (11-digit) C/D ADD-ON data (2- or 5-digit)
(14-digit) PI 0Data (11-digit) C/D ADD-ON data (2- or 5-digit)
EAN-8 with add-on (16-digit) 01 PI 0Data (11-digit) C/D ADD-ON data (2- or 5-digit)
(14-digit) PI 0Data (11-digit) C/D ADD-ON data (2- or 5-digit)
UPC-A with add-on (16-digit) 01 PI 0Data (11-digit) C/D ADD-ON data (2- or 5-digit)
(14-digit) PI 0Data (11-digit) C/D ADD-ON data (2- or 5-digit)
UPC-E with add-on (16-digit) 01 PI 0Data (11-digit) C/D ADD-ON data (2- or 5-digit)
(14-digit) PI 0Data (11-digit) C/D ADD-ON data (2- or 5-digit)
UPC-E code data is converted to the ZERO insertion format and then to the GTIN format.
(C/D: Check digit)
(PI: Package indicator)
(2) Conversion of Interleaved 2of5 (14-digit) to GTIN format
In the case of Interleaved 2of5 symbology, conversion to the GTIN format applies to 14-digit data. Other number of
digits of data is transmitted in the original format.
Interleaved 2of5 (14-digit) 01 Data (13-digit) C/D
01 Data (14-digit)
(C/D: Check digit)
Check digits are transmitted regardless of the setting.
(3) Conversion of GTIN format RSS/EAN-128 to EAN/JAN
If converting to EAN/JAN (product code format), it is possible to select from conversion to 14 digits or conversion to
13 digits. Furthermore, by selecting prohibition of conversion to EAN/JAN, it is possible to prohibit only the
conversion of GTIN format RSS/EAN-128 codes to EAN/JAN.
Conversion provides two choices--14- and 13-digit EAN formats.
RSS, EAN-128 (14-digit)PI Data (12-digit) C/D
(13-digit)Data (12-digit) C/D
(C/D: Check digit)
(PI: Package indicator)
38
Page 48
Chapter 11 Parameters and Defaults
The tables below list the parameters and their defaults. Those parameter settings can be changed with the bar-coded
parameter menu and configuration software (ScannerSetting), except shadowed ones only with the configuration
software.
When the scanner leaves the factory, all of these parameters are set to defaults.
(1) Interface to the host
Items Parameters DefaultsRefer to:
Interface
(2) Asynchronous data transmission (RS-232C interface)
The following settings take effect when the RS-232C interface is used.
Items Parameters DefaultsRefer to:
Communications protocol
RTS signal control protocol
CTS signal monitor
Transmission speed
Data bit
Parity
Stop bit
Header
Terminator
CTS signal timeout 0.1 to 9.9 s 0.2 s
ACK/NAK response time 0.1 to 9.9 s 1 s
RS-232C interface √
PS/2 keyboard interface
Non-acknowledge mode √
ACK/NAK mode
Scanner ready mode √
Data ready mode
Enable
Disable √
1200 bps
2400 bps
4800 bps
9600 bps √
19200 bps
38400 bps
7 bits
8 bits √
Odd
Even
None √
1 bit √
2 bits
None √
STX
ETX
CR √
LF
CR LF
None
: Can be changed only with the configuration software.
39
Section 10.1 (1)
Section 10.1 (2)
Section 10.1 (3)
Section 10.1 (4)
Section 10.1 (5)
Section 10.3.1 (1)
Section 10.1 (1)
Page 49
N
(3) PS/2 keyboard interface
The following settings take effect when the PS/2 keyboard interface is used.
Items Parameters DefaultsRefer to:
With external keyboard √
Keyboard connection type
Caps Lock of host's keyboard
Num Lock of host's keyboard
Keyboard type
Data transmission interval
Numeric key type
Without external keyboard
With external numeric keypad
OFF (Lowercase letter) √
ON (Uppercase letter)
ON √
OFF
U.S. English (101 key type) √
Germany (102 key type)
French (102 key type)
U.K. English (102 key type)
Italian (102 key type)
Swedish (102 key type)
Japanese (106 key type)
IBM 5576-001
IBM 5576-002/003
1 ms √
5 ms
10 ms
15 ms
30 ms
50 ms
100 ms
Inboard numeric keys √
Numeric keypad
Section 10.2 (1)
Section 10.2 (2)
(See Note 1.)
Section 10.2 (3)
Section 10.2 (4)
(See Note 2.)
(Note 1) Select the Caps Lock and Num Lock states that match the host's keyboard states.
(Note 2) When selecting "Numeric keypad," set the host's Num Lock to ON.
Inboard numeric keys
U.S. English (101 key type)
40
umeric keypad
Page 50
Items Parameters DefaultsRefer to:
Special key transmission
Enable
Disable √
(See Note 3.)
None √
STX
ETX
CR
LF
CR LF
TAB
Header
ESC
Section 10.3.1 (1)
ENTER
Right Ctrl
←
↑
→
↓
User-defined
(Note 3) Special key transmission applies to the fields except header and terminator in the data transmission format.
Enabling this function substitutes E7h to FDh data with the special keys as listed below and transmits the
substituted data to the host.
The Left SHIFT, Left CTRL, and Left ALT are transmitted as a simultaneous depression with the subsequent
character or key.
Upper
Lower
E F
0↓
1 F1
2 F2
3 F3
4 F4
5 F5
6 F6
7 Left SHIFT F7
8 Left CTRL F8
9 Left ALT F9
A TAB F10
B ESC F11
C ENTER F12
D ← Right CTRL
E ↑
F →
Special Key Substitution Table
: Can be changed only with the configuration software.
41
Page 51
Terminator
Items Parameters DefaultsRefer to:
None
STX
ETX
CR
LF
CR LF
TAB
ESC
Section 10.3.1 (1)
ENTER √
Right Ctrl
←
↑
→
↓
User-defined
: Can be changed only with the configuration software.
42
Page 52
(4) Data transmission format and bar code symbologies
Items Parameters DefaultsRefer to:
Prefix transmission
Suffix transmission
Data editing
Transmission of code ID mark
Code ID mark position
Enable
Disable √
Enable
Disable √
Enable
Disable √
Enable
Disable √
Before prefix
After prefix √
Type 1 (DENSO 1) √
Type 2 (DENSO 2)
Type 3
Code ID mark
Type 4
Type 5 (AIM)
Type 6 (AIM Type 2)
User-defined
Enable, in 4 digits
Transmission of the number of digits
(not applicable to UPC/EAN codes)
Enable, in 2 digits
Disable √
GTIN format conversion
Enable
Disable √
16-digit GTIN format √
Conversion type from EAN/UPC/
Interleaved 2of5 (14-digit) to GTIN format
14-digit GTIN format
Disable conversion
14-digit EAN format √
Conversion type from RSS/EAN-128 in
GTIN format to EAN format
13-digit EAN format
Disable conversion
Prefix PI in conversion from EAN/UPC/
Interleaved 2of5 (14-digit) to GTIN format
0 to 9 0 Section 10.3.2 (1)
Section 10.3.1 (2)
Chapter 8
Section 10.3.1 (3)
Section 10.3.1 (4)
Section 10.3.2
Section 10.3.2 (1)
Section 10.3.2 (2)
: Can be changed only with the configuration software.
43
Page 53
UPC-A/E, EAN-13/8
Items Parameters DefaultsRefer to:
Reading UPC-A, UPC-E, EAN-13 and
EAN-8
Reading UPC/EAN with 2-digit add-on
Reading UPC/EAN with 5-digit add-on
Transmission of the number system character
of UPC-A
Transmission of the number system
character of UPC-E
Transmission of padding characters "0" for
UPC-A
Transmission of padding characters "0" for
UPC-E
Transmission of a check digit for UPC-A
Transmission of a check digit for UPC-E
Transmission of a check digit for EAN-13
Transmission of a check digit for EAN-8
Transmission format of EAN-8
(Conversion to EAN-13)
Transmission format of UPC-E
(Conversion to UPC-A)
Transmission of country code for EAN-13
Conversion to ISBN/ISSN format
for EAN-13
Enable √
Disable
Enable
Disable √
Enable
Disable √
Enable √
Disable
Enable √
Disable
Enable √
Disable
Enable
Disable √
Enable √
Disable
Enable √
Section 10.3.1 (5)
Disable
Enable √
Disable
Enable √
Disable
Enable conversion
Disable conversion √
Enable conversion
Disable conversion √
Enable √
Disable
Enable
Disable √
Section 10.3.1 (5)
(See Note 4.)
Section 10.3.1 (5)
(Note 4) A country code is in the upper two digits of the prefix character field in EAN-13.
: Can be changed only with the configuration software.
44
Page 54
Standard 2of5
Items Parameters DefaultsRefer to:
Scanning Standard 2of5
Minimum number of digits readable
for Standard 2of5
Maximum number of digits readable
for Standard 2of5
Transmission of a check digit
for Standard 2of5
Specification of the number of digits for
Standard 2of5, by bar code scanning
Interleaved 2of5
Scanning Interleaved 2of5
Minimum number of digits readable
for Interleaved 2of5
Maximum number of digits readable
for Interleaved 2of5
Transmission of a check digit
for Interleaved 2of5
Specification of the number of digits for
Interleaved 2of5, by bar code scanning
Items Parameters DefaultsRefer to:
Codabar (NW-7)
Scanning Codabar (NW-7)
Minimum number of digits readable
for Codabar (NW-7)
Maximum number of digits readable
for Codabar (NW-7)
Transmission of a check digit
for Codabar (NW-7)
Items Parameters DefaultsRefer to:
Enable, without C/D
Enable, with C/D
Disable √
3 digits
1 to 99 digits
99 digits
Enable √
Disable
Enable
Disable √
Enable, without C/D √
Enable, with C/D
Disable
4 digits
2 to 99 digits
99 digits
Enable √
Disable
Enable
Disable √
Enable, without C/D √
Enable, with C/D
Disable
3 to 99 digits
(including start/stop codes)
Enable √
Disable
4 digits
99 digits
(See Note 5.)
Section 10.3.1 (5)
(See Note 6.)
Section 7.2
(See Note 5.)
Section 10.3.1 (5)
(See Note 6.)
Section 7.2
(See Note 5.)
Section 10.3.1 (5)
(See Note 6.)
(Note 5) The setting range differs from the number of digits that the scanner can actually read.
(Note 6) To enable the transmission of a check digit, it is also necessary to select the "Enable, with C/D" parameter for
scanning.
: Can be changed only with the configuration software.
45
Page 55
Item Parameters DefaultsRefer to:
Check digit method for Codabar (NW-7)
Transmission of start/stop codes
for Codabar (NW-7)
Code 32
Item Parameters DefaultsRefer to:
Conversion from Code 39 to Code 32 format
Transmission of leading "A" in Code 32 data
Checking of a check digit in Code 32 data
Code 39
Item Parameters DefaultsRefer to:
Scanning Code 39
Minimum number of digits readable
for Code 39
Maximum number of digits readable
for Code 39
Transmission of a check digit for Code 39
Transmission of start/stop codes for Code 39
Conversion to Full ASCII for Code 39
Code 93
Items Parameters DefaultsRefer to:
Scanning Code 93
Minimum number of digits readable
for Code 93
Maximum number of digits readable
for Code 93
MOD-16 √
7-check method
Transmit a/b/c/d
Section 10.3.1 (5)
Transmit A/B/C/D
Disable √
Enable
Disable √
Enable
Disable √
Section 10.3.1 (5)
Enable
Disable √
Enable, without C/D √
Enable, with C/D
Disable
1 to 99 digits
(excluding start/stop codes)
Enable √
Disable
1 digit
99 digits
(See Note 5.)
Section 10.3.1 (5)
(See Note 6.)
Enable
Disable √
Enable
Section 10.3.1 (5)
Disable √
Enable
Disable √
1 to 99 digits
(excluding start/stop codes and 2-digit
C/D)
1 digit
99 digits
(See Note 5.)
(Note 5) The setting range differs from the number of digits that the scanner can actually read.
(Note 6) To enable the transmission of a check digit, it is also necessary to select the "Enable, with C/D" parameter for
scanning.
: Can be changed only with the configuration software.
46
Page 56
Code 128, EAN-128
Items Parameters DefaultsRefer to:
Scanning Code 128
Scanning EAN-128
Minimum number of digits readable
for Code 128 and EAN-128
Maximum number of digits readable
for Code 128 and EAN-128
Transmission of FNC1 for Code 128 and
EAN-128
Enable √
Disable
Enable √
Disable
1 to 99 digits
(excluding 1-digit C/D)
1 digit
99 digits
Transmit after conversion to GS √
Disable
MSI, Plessey
Items Parameters DefaultsRefer to:
Scanning MSI
Minimum number of digits readable for MSI3 digits
Maximum number of digits readable for MSI
Scanning Plessey
Minimum number of digits readable
for Plessey
Maximum number of digits readable
for Plessey
Enable
Disable √
3 to 99 digits
(including 2-digit C/D)
99 digits
Enable
Disable √
4 to 99 digits
(including 2-digit C/D)
4 digits
99 digits
RSS
Item Parameters DefaultsRefer to:
RSS-14 Stacked,
RSS-14 Stacked Omnidirectional
Scanning RSS Limited
Enable Scanning RSS-14, RSS-14 Truncated,
Disable √
Enable
Disable √
(See Note 5.)
Section 10.3.1 (5)
(See Note 5.)
(See Note 5.)
(Note 5) The setting range differs from the number of digits that the scanner can actually read.
: Can be changed only with the configuration software.
47
Page 57
(5) Trigger switch control and magic key control
Items Parameters DefaultsRefer to:
Auto-off mode 1
Auto-off mode 2
Trigger switch control
Momentary switch mode 1 √
Momentary switch mode 2
Continuous reading mode
Auto sensing mode
1 sec.
2 sec.
Scanning period in auto-off mode 1
3 sec.
4 sec.
5 sec. √
High (Sensitive)
Scanner sensibility level in auto sensing
mode
Medium √
Low (Insensitive)
Illumination switching function
Data retransfer function
Specific character transfer function
Magic key control
Ready/standby switching function
Auto sensing mode switching function
Continuous reading mode switching
function
No function √
Section 5.1
Section 5.1
Section 5.3
Chapter 6
: Can be changed only with the configuration software.
48
Page 58
(6) Beeper, indicator LED and vibrator
Items Parameters DefaultsRefer to:
Beeper
Beeping time of a short beep
Beeper volume
Beeper frequency
Trigger timing for the reading completion
beeper and indicator LED
Beeper when reading RSS-14 Stacked and
RSS-14 Stacked Omnidirectional
Beeping pattern when reading RSS-14
Stacked and RSS-14 Stacked
Omnidirectional
Indicator LED
Vibrator
Enable √
Disable
Section 9.1
Short (60 ms) √
Medium (80 ms)
Section 9.1
Long (120 ms)
High √
Medium
Section 9.1
Low
Low (2.0 kHz)
Medium (4.0 kHz) √
Section 9.1
High (4.3 kHz)
Before data transmission √
After data transmission
Enable √
Disable
Section 9.1
One-shot beep √
Intermittent beep
Enable √
Disable
Section 9.2
"OK" vibrations √
"NG" vibrations
Section 9.3
Disable
: Can be changed only with the configuration software.
49
Page 59
(7) Data verification mode
Items Parameters DefaultsRefer to:
Scanning modes
Data verification type
Verification retry after mismatch
in 2-point verification
Verification result output in data
verification mode
(Report of match/mismatch status)
Regular read mode √
Data verification mode
2-point verification
n-point verification √
Disable √
Enable
Disable transmission/
Disable transmission
Enable bar code data transmission/
Disable transmission
Enable bar code data transmission/
Enable NG transmission
Enable OK transmission/
Enable NG transmission
1st character √
2nd character
3rd character
Verification start position in data
verification mode
4th character
5th character
6th character
7th character
1 character
2 characters
3 characters
Number of characters to verify, starting
from the verification start position
4 characters
5 characters
6 characters
7 characters
No specification √
Scan lock in data verification mode
Enable
Disable √
(8) Notification of a scanning failure under software control
Items Parameters DefaultsRefer to:
Notification of a scanning failure that
occurred under software control
Enable CAN (18h) transmission √
Enable "ERROR" transmission
Disable transmission
√
Section 7.1
Section 5.2
: Can be changed only with the configuration software.
50
Page 60
(9) Speed-/depth-priority scanning
Items Parameters DefaultsRefer to:
Speed-/depth-priority scanning
(Note 7) The default is speed-priority scanning for the GT10B-SM/GT11B-SM, and depth-priority scanning for the
GT10B-LM.
Speed-priority scanning √
Depth-priority scanning √
: Can be changed only with the configuration software.
Chapter 3
(See Note 7.)
51
Page 61
Chapter 12 Bar-Coded Parameter Menu
12.1 Parameter Setting Procedure Using the Bar-Coded Parameter Menu
"Start setting"
↓ Three beeps
Scan parameter setting
bar codes.
↓
"End setting"
Three beeps
Scanning the "All defaults" bar code in the bar-coded parameter menu makes all items in the menu revert to the
factory defaults.
TIP: "Interface" and "Beeper volume" bar codes in the bar-coded parameter menu
These items can be set even if the above procedure is omitted. No "Start setting" or "End setting" bar code is required
to be scanned.
Scan the "Start setting" bar code.
Scan desired parameter setting bar codes.
NOTE: When using the bar-coded parameter menu, scan bar codes within three
minutes. Otherwise, the scanner cancels newly settings and returns to the previous
ones.
Scan the "End setting" bar code.
52
Page 62
12.2 Bar-Coded Parameter Menu
Menu control (Starting/ending the setting procedure and reverting to defaults)
Start setting
All defaults
The beeper volume and interface items can be set by only scanning the following bar codes. No "Start setting" or
"End setting" bar code is required to be scanned.
Adjusting the beeper volume
Scanning the following bar code cycles between the High, Medium, and Low settings. The factory default is
High.
End setting
Selecting the interface
RS-232C interface
Beeper volume
53
PS/2 keyboard interface
Page 63
Communications parameters for the RS-232C interface
Communications protocol (RS-232C interface)
Non-acknowledge mode (default)
RTS signal control mode (RS-232C interface)
Scanner ready mode (default)
CTS signal monitor (RS-232C interface)
Enable
Transmission speed (RS-232C interface)
1200 bps
ACK/NAK mode
Data ready mode
Disable (default)
2400 bps
4800 bps
19200 bps
9600 bps (default)
38400 bps
54
Page 64
Data bits (RS-232C interface)
7 bits
Parity (RS-232C interface)
Odd
8 bits (default)
None (default)
Stop bits (RS-232C interface)
1 bit (default)
Header (RS-232C interface)
None (default)
Terminator (RS-232C interface)
ETX
Even
2 bits
STX
CR (default)
LF
None
CR LF
55
Page 65
Communications parameters for the PS/2 keyboard interface
Keyboard connection type (PS/2 keyboard interface)
With external keyboard (default)
With external numeric keypad
Caps Lock of host's keyboard (PS/2 keyboard interface)
Select the Caps Lock state that matches the host's keyboard state.
OFF (default)
Num Lock of host's keyboard (PS/2 keyboard interface)
Select the Num Lock state that matches the host's keyboard state.
ON (default)
Without external keyboard
ON
OFF
56
Page 66
Keyboard type (PS/2 keyboard interface)
Select the type of the keyboard to be connected.
U.S. English (101 Keyboard) (default)
French (102 Keyboard)
Italian (102 Keyboard)
Japanese (106 keyboard)
IBM 5576-002/003
Germany (102 Keyboard)
U.K. English (102 Keyboard)
Swedish (102 Keyboard)
IBM 5576-001
57
Page 67
Header (PS/2 keyboard interface)
None (default)
ETX
LF
TAB
ENTER
←
STX
CR
CR LF
ESC
Right Ctrl
→
58
↑
↓
Page 68
Terminator (PS/2 keyboard interface)
None
ETX
LF
TAB
ENTER (default)
←
STX
CR
CR LF
ESC
Right Ctrl
→
59
↑
↓
Page 69
Data transmission interval (PS/2 keyboard interface)
Select the data transmission interval according to the computer's processing speed.
If bar code data is not displayed correctly (e.g., character missing), use a longer interval.
1 ms (default)
10 ms
30 ms
100 ms
Numeric key type (PS/2 keyboard interface)
Inboard numeric keys (default)
Special key transmission (PS/2 keyboard interface)
Enable
5 ms
15 ms
50 ms
Numeric keypad
Disable (default)
60
Page 70
Data transmission format and bar code symbologies
Transmission of code ID mark
Enable
Code ID mark position
Code ID mark
Type 1 (DENSO 1) (default)
Before prefix
Type 3
Type 5 (AIM)
Disable (default)
After prefix (default)
Type 2 (DENSO 2)
Type 4
Type 6 (AIM Type 2)
Transmission of the number of digits (not applicable to UPC/EAN codes)
Enable, in 4 digits
Disable (default)
61
Enable, in 2 digits
Page 71
UPC-A/-E and EAN-13/-8
Scanning UPC-A, UPC-E, EAN-13 and EAN-8
Enable (default)
Scanning UPC/EAN with Add-on
Enable, no restriction on add-on digits
Enable 2-digit add-on only
Transmission of the number system character of UPC-A
Enable (default)
Transmission of the number system character of UPC-E
Enable (default)
Disable
Enable 5-digit add-on only
Disable (default)
Disable
Disable
Transmission of the pad character "0" for the specified number of digits of UPC-A
Enable (default)
62
Disable
Page 72
Transmission of the padding character "0" for the specified number of digits of UPC-E
Enable
Transmission of a check digit for UPC-A
Enable (default)
Transmission of a check digit for UPC-E
Enable (default)
Transmission of a check digit for EAN-13
Enable (default)
Transmission of a check digit for EAN-8
Enable (default)
Disable (default)
Disable
Disable
Disable
63
Disable
Page 73
Transmission format of EAN-8 (Conversion to EAN-13)
Enable conversion
Transmission format of UPC-E (Conversion to UPC-A)
Enable conversion
Transmission of country code for EAN-13
Enable (default)
Conversion to ISBN/ISSN format for EAN-13
Enable
Standard 2of5
Scanning Standard 2of5
Enable, without C/D
Disable conversion (default)
Disable conversion (default)
Disable
Disable (default)
Disable (default)
Enable, with C/D
64
Page 74
Transmission of a check digit for Standard 2of5
Enable (default)
Specification of the number of digits for Standard 2of5, by bar code scanning
Enable
Interleaved 2of5
Scanning Interleaved 2of5
Enable, without C/D (default)
Disable
Transmission of a check digit for Interleaved 2of5
Enable (default)
Disable
Disable (default)
Enable, with C/D
Specification of the number of digits for Interleaved 2of5, by bar code scanning
Enable
65
Disable (default)
Disable
Page 75
Scanning Codabar (NW-7)
Enable, without C/D (default)
Codabar (NW-7)
Disable
Transmission of a check digit for Codabar (NW-7)
Enable (default)
Calculation method for a check digit of Codabar (NW-7)
MOD-16 (default)
Transmission of start/stop codes for Codabar (NW-7)