The squirt DC is a battery operated chemical dispenser with a programmable timer designed
primarily for dispensing chemical into drains. Its intended use is for drain applications when a
degreaser is needed in the drain regularly. The timer is programmable up to 8 events and can be
set for specified time periods to run the pump.
Warnings
Installation of DEMA products must meet all applicable electrical codes and
regulations established by national, city, county, parish, provincial or other
agencies. It is possible that electrical codes and regulations require that a certified
electrical contractor or engineer perform the electrical installation. For questions,
contact a certified electrician.
ALL ELECTRICAL POWER MUST BE TURNED OFF TO THE
DISPENSER AND TO THE APPLIED MACHINE.
All installations must conform to local plumbing codes and use approved
backflow prevention devices. A pressure indicating tee is to be installed with
existing faucets according to local plumbing codes in the state of Wisconsin and
any other state that requires the use of a pressure indicating tee.
ALWAYS WEAR PROTECTIVE CLOTHING AND EYEWEAR WHEN
WORKING WITH CHEMICAL PRODUCTS.
I-1048 Page 1 of 7
Rev. A-39406 11/27/13
Page 2
Specifications
Packing List
DEMA
NO.
2504 25-220-1 81-16-3 25-68-20 (LDPE) 81-312-1
2505 25-220-1 81-16-3
Operational Requirements
Overall Size
SQUIRT
DC DRAIN
UNIT
Main Power (8) D-CELL BATTERIES (NOT INCLUDED)
Case Material ABS
Product Weight 1.18 kg 2.60 lbs.
The integrity and operational characteristics of this unit are not guaranteed
outside the above mentioned parameters. Use of this unit outside of these
CABLE
TIES (8)
For indoor use only
parameters nullifies warranty.
¼” TUBING
25-160-20 (SUPER
TUBE)
SPLIT
PICK UP
TUBE
81-312-1
SQUEEZE TUBE
81-231-1
(EPDM, JACO)
81-231-4
(EPDM, CONE)
I-1048 Page 2 of 7
Rev. A-39406 11/27/13
Page 3
Parts List
NO. PART NO. DESCRIPTION
1 81-278-1 PUMP BLANK COVER
2 81-226-5 PUMP HEAD ASSY.
3 81-220-1 DRIVE SHAFT ADAPTER
4 81-311-2 118 RPM MOTOR ASSEMBLYT
5 25-212-2 (8) POSITION D-CELL BATTERY HOLDER
6 25-20-3 TIMER
7 44-116-2 #8 X 3/8” HI/LO SCREW
8 81-18-1 #6 X 3/8” HI/LO SCREW
9 83-16-2 VELCRO PATCH
Installation
Mount the unit no higher than 6 feet from the chemical container. Take into account the
proximity to the chemical, and the drain. Secure the mounting bracket to the wall and then mount
the unit on the wall. Cut the tubing to the proper length to reach from the chemical container to
the dispenser and the dispenser to the drain where the chemical is being dispensed.
I-1048 Page 3 of 7
Rev. A-39406 11/27/13
Page 4
Squeeze Tube Installation
Install the squeeze tube by removing the pump cover by depressing the tab on the front of the
unit. (1) Place one end of the squeeze tube on the left side of the pump in the slot provided. (2)
Wrap the squeeze tube around the rollers of the pump. (3) Then stretch the squeeze tube so that
the end of the tube goes into the slot provided. (4) Replace the cover on the pump.
(1) (2) (3) (4)
Close Pump Head
The pump head has an added feature which will help to ensure the pump head is retained
properly. When pushing the pump head on, be sure to push the pump head on tightly so that the
tab is grasping the pump head. If the tab is not fully engaged, there is a possibility the pump
head becoming dislodged.
Pump head
Push tab up
Correct Incorrect
Operation
Programming the Dispenser
CAUTION: When the unit is powered the first time, a rechargeable
display back up battery begins charging. When fully charged it
provides approximately 200 hours of reserve time before the display
and program may be lost. If the unit loses power, it will not lose the
program for 200 hours, but it will not run the pump from the
rechargeable display back up battery and will not dispense chemical. If
the unit becomes unplugged from the wall for a short amount of time,
plugging the unit back in will not affect the programming done to the
unit.
I-1048 Page 4 of 7
Rev. A-39406 11/27/13
Page 5
A. Press the reset button before programming.
Note: If a mistake is made during the programming, simply push the reset button
and start over.
B. 12 Hour or 24 Hour (Military) Mode
1. Hold the “Clock” button down for 5 seconds or more to change back & forth to
between the 12 & 24 hour modes.
C. SettheTimeandDay
When the unit arrives the display may be blank or may display a time. Insert the (8) D-Cell
batteries into the dispenser and that will provide power to the timer.
NOTE: Make sure that the indicator bar in the bottom of the display is over the word
OFF. Press the MANUAL button until it is in the off position.
1. To set the time and day of the week, press and hold the CLOCK button and press the day,
hour, and minute buttons until the proper day, hour, and minute is achieved.
Note: The days will be across the top of the screen and will advance as the button is
pressed. The time must be set to AM or PM. Pressing in the Day, Hour, or Minute
button for three seconds will advance the setting until the button is released.
C. Programming the Dispensing Events: Up to 8 independent dispensing events can be
programmed
1. Press and release the TIMER button to enter the programming mode. The event number
will be in the bottom left corner. Note: To program a full event, a pump start time and
stop time will need to be programmed.
NOTE: THE PUMP WILL RUN FOR 23 HRS 59 MIN NO SOP TIME HAS BEEN
SET.
a) Press the “DAY” button until the desired days are shown.
b) Press the “HOUR” and “MINUTE” buttons until the time is reached when the pump
should start.
Note: AM or PM in top left corner of screen.
2. Press and release the TIMER button again to move to programming the pump stop time.
a) This setup will be used to turn the pump off. Use
the table to determine the pump run time.
b) Press the “DAY” button until the days match the
days programmed in the pump start portion of the
programming.
c) Press the “HOUR” and “MINUTE” buttons until
the desired run time is reached.
3. To program another event, press TIMER button
again for Programs 2-8 and follow Programming
Steps 1 and 2 above. Every START function needs a
RUN
TIME
1 min 110 ml 3.5 oz
3 min ~295 ml ~10 oz
5 min 550 ml 17.5 oz
6 min ~590 ml ~20 oz
10 min 1100 ml 35 oz
20 min 2200 ml 70 oz
AMOUNT
DISPENSED
ml oz
corresponding STOP function in order to stop the pump.
4. When finished programming, push the CLOCK button again to return to time of day
(normal) display.
D. Priming the Pump
I-1048 Page 5 of 7
Rev. A-39406 11/27/13
Page 6
1. To prime the pump, press the MANUAL button – the bar at the bottom of the display will
move from right to left from OFF to AUTO to ON. When it reaches ON, the pump will
run until the MANUAL button is pressed again. Use this position to prime the pump. To
stop priming press the MANUAL button – the bar at the bottom of the display will move
from left to right from ON to AUTO to OFF.
Note: The unit may continue to run in the AUTO position. The MANUAL button
must be pressed until the bar at the bottom of the display is over the OFF position to
stop the pump.
E. Setting into Programmed Position
1. Press the MANUAL button until the bar in the bottom of the display moves from the OFF
to the AUTO position. If the unit is not in the AUTO position, the program will not be
executed.
Troubleshooting
Symptom Probable Cause Remedy
1. Check the program, date, and time to make sure
they are set properly. A common mistake could be
where an AM is supposed to be a PM.
2. Check the programs for a stop time for each
program.
1. Check the tubing from the chemical container to
the pump head for leaks by feeling the tubing for
chemical that has leaked out. Replace the tube if
necessary.
2. Replace the squeeze tube after inspecting it for a
possible hole or leak.
3. Tighten the nuts on the squeeze tube fitting.
1. Check the program(s) to make sure they are set
properly. A common mistake could be where an
AM is supposed to be a PM.
2. Replace batteries.
1. Check the programs for a stop time for each
program; make sure the events are matched up.
Pump running when it is not
programmed to run.
Pump is not priming or not
holding a prime.
Pump over feeding (using
too much chemical). Pump
under feeding (not enough
chemical).
Pump runs constantly.
1. The program, date, or time are set
wrong.
2. Did not program stop time.
1. Hole in the tubing from the chemical
container to the pump head.
2. Hole in the squeeze tube in the pump
head.
3. Pick up tubing is not sealed to the
squeeze tube fitting.
1. The programs entered in the unit were
set wrong.
2. The batteries are low on power
1. Did not match the Event #, Days or
AM/PM for the stop time.
Warranty
Merchandise Returns
No Merchandise will be returned for credit without DEMA’S written permission. Returned merchandise
authorization number is required in advance of return.
Product Warranty
DEMA products are warranted against defective material and workmanship under normal use and service
for one year from the date of manufacture. This limited warranty does not apply to any products that have
a normal life shorter than one year or failure and damage cause d by chemicals, corrosion, physical abuse,
or misapplication. Rubber and synthetic rubber parts such as “O”-rings, diaphragms, PVC tubing, and
gaskets are considered expendable and are not covered under warranty. This warranty is extended only to
I-1048 Page 6 of 7
Rev. A-39406 11/27/13
Page 7
the original buyer of DEMA products. If products are altered or repa ired without prior approval of DEMA,
this warranty is void.
Defective units or parts should be returned to the factory with transportation prepaid. If inspection shows
them to be defective, they will be repaired or replaced without charge, F.O.B. factory. DEMA assumes no
liability for damages. Return merchandise authorization number must be granted in advance of returned
units for repair or replacement (See “Merchandise Returns” above).
I-1048 Page 7 of 7