DELVCAM DELV-2LCD-7XLPRO, DELV-2LCD-RM, DELV-2LCD7XLS User Manual

Page 1
DUAL NTSC 7" COLOR TFT 16:9 / 4:3
LCD R
ACKMOUNT MONITOR SERIES
USER MANUAL
DELV-2LCD-7XLPRO DELV-2LCD7XLS
DELV-2LCD-RM
Page 2
Looping BNC input
STANDARD NTSC-M
POWER REQUIREMENTS
DELV-2LCD-7XLPRO: 110-220 Volts AC 50/60 cyc Auto switching, 14 watts DELV-2LCD7XLS:(SDI) 110-220 Volts AC 50/60 cyc Auto switching, 14 watts DELV-2LCD-RM: Dual AC Power Adapters 12v 2A
OPERATING TEMPERATURE 32-122 Degrees F (0-50°C) REMOTE CONTROL Handheld Infrared
DIMENSIONS
DELV-2LCD-7XLPRO: 19"W x 4.5"D x 7"H (4RU) DELV-2LCD7XLS:(SDI) 19"W x 4.5"D x 7"H (4RU) DELV-2LCD-RM: 19"W x 1.75"D x 7"H (4RU) WEIGHT XLPRO-16.0 Lbs.
XLS-18.0 Lbs. RM-10.0 Lbs.
Features:
Picture Mode Select: 16:9 Wide Cinema Mode
4:3 Normal Mode 4:3 Wide Mode
4:3 Full Mode Looping BNC inputs High Resolution Performance NTSC-M Standard CATV, UHF, VHF TV Receiver (Monitor A only) Allows 180° of tilt while mounted in rack Low power consumption and heat dissipation for mobile applications Fits in standard 19" rack, 4 spaces high On screen color, tint, brightness and contrast controls Wireless I/R remote control Assembled in USA, 3 Year Warranty
I. Product Description
Get ready for the new and demanding high resolution video production market, the Delvcam LCD series advanced monitoring system is loaded with features. A dual mon­itor rackmount solution for the high end video environment, the Delvcam LCD series provides both 16:9 and standard 4:3 aspect ratio video monitoring in a well designed, rackmount housing with optional adjustable pitch.
II. Product Specifications
Page 3
III. Items Included
DELV-2LCD-7XLPRO & DELV-2LCD7XLS
Hand-Held IR Remote Control Unit (2)
75 Ohm Terminator (2)
RF Adapter (Monitor A Only)
110-220V 50/60Hz Power Adapter: 12VDC @ 4A
2
4
3
1
Items Included
DELV-2LCD-RM
Hand-Held IR Remote Control Unit (2)
Video Input Looping Cable / Terminator (2)
BNC Male to RCA Female Adapter (2)
RF Adapter (2)
A/V Input Cable (2)
110-220V 50/60Hz Power Adapter: 12VDC @ 1A (2)
12V Cigarette Adapter (2)
4
2
3
1
5
6
7
1
2
3
4
1
2
3
5
6
7
4
Page 4
IV. Front Panel Product Controls
IR Remote
Complete instructions for LCD setup and operation are covered in the included LCD
manual. Please note that the manual does cover mechanical items and topics that
are no longer covered for the Delvcam dual-rack monitor configuration.
It is recommended that you read and study that manual first.
Selects between composite video and SDI (DELV-2LCD7XLS only)
Page 5
Power Entry
Monitor B - Video input (looping)
Monitor B - Audio input
Monitor B - SDI input (DELV-2LCD7XLS only)
Monitor A - RF (CATV) input
Monitor A - Audio input
Monitor A - SDI input (DELV-2LCD7XLS only)
Monitor A - Video input (looping)
6
8
7
2
4
1
5
3
1
2
3
4
5 6
V. Rear Panel Connections
DELV-2LCD-7XLPRO & DELV-2LCD7XLS
V. Monitor Tilt Operation
Mount Monitor in Rack
Push Top or Bottom of Monitor to Tilt as Desired
2
1
7 8
Side View
Page 6
Monitor B - Audio Input
Monitor B - Video Input Looping
(Looping / Termination Cable Provided)
Monitor B - Headphone Audio Output
Monitor B - Power Input
Monitor A -
Audio Input
Monitor A - Video Input Looping
(Looping / Termination Cable Provided)
Monitor A - Headphone Audio Output
Monitor A - Power Input
Monitor B - RF Antennna (CATV) Input
Monitor B - External Antenna
Monitor A - RF Antennna (CATV) Input
Monitor A - External Antenna
7
8
6
2
4
1
5
3
1 2
3
4
5 6
VI. Rear Panel Connections
DELV-2LCD-RM
7 8
9
9
10
11
10
11
12
12
Page 7
SAFETY WARNING
1. To prevent fire or shock hazard, do not expose this equipment to the environment of high humidity and dust. Do not use it in an unprotected outdoor installation or any area classified as wet.
2. The temperature for installation should be kept between -40°C ~ +95°C. Avoid direct sunlight or extreme changes of temperature.
3. For the sake of safety, do not disseminate the unit or put it on an unstable base. Do not drop it and avoid heavy impact.
4. Ventilation: Openings in the enclosure are provided for ventilation and to ensure reliable operation of the unit and to protect it from overheating. These openings must not be blocked or covered. This unit should not be placed in a built-in installation unless proper ventilation is provided.
5. Cleaning: Unplug the unit from the outlet before cleaning. Do not use liquid cleaners or aerosol cleaners. Use a damp cloth.
6. Overload: Do not overload outlets and extension cords as this may result in a risk of fire or electric shock.
7. Object and Liquid Entry: Never push objects of any kind into this unit through openings as they may touch dangerous voltage points or short-out parts that could result in a fire or electric shock. Never spill liquid of any kind on the unit.
8. Service: Do
not attempt to open or service this unit yourself as opening or removing covers may expose you to dangerous voltage of other hazards.
Page 8
1 Tower Drive Saugerties, NY 12477 Tel 845-246-0428 Fax 845-246-0626
Video Source
75 ohm Terminator
DELV-LOOP
5 / 7XLPRO LCD Monitor Looping Accessory
This monitor has been designed and shipped with an open 75 ohm (unterminated) video input. It must not be used without proper termina­tion provided by the looping / terminating Y-cable included with monitor. Several monitors (DELV-5XLPRO / DELV-7XLPRO) can be looped using standard looping / terminating procedures which observes 75 ohm line terminat ion at the last monitor. See diagram below:
75 ohm
Terminator
Video Input
BNC
Video Out to
Monitor
Bridging
Audio Input
Looping
Video Input
Monitor 1
Monitor 2
Monitor 3
Typical three monitor looping set-up
note that monitor 3 provides final termination
Y-cable
1
Y-cable
2
Y-cable
3
Loading...