Delta Electronics DVP28SV11R, DVP28SV11T Instruction Sheet

Warning
This Instruction Sheet only provides descriptions for electrical specifications, general specifications, installation &
wiring. Other detail infromation about programming and intructions is compatible with EH series; please see PLC Application Manual. For more information about the optional peripherals, please see individual product instuction shee or “DVP-PLC Application Manual: Special module”.
This is an OPEN TYPE PLC. The PLC should be kept in an enclosure away from airborne dust, humidity, electric
shock risk and vibration. Also, it is equipped with protective methods such as some special tools or keys to open the enclosure, in order to prevent hazard to users or damage the PLC.
Do NOT connect the AC main circuit power supply to any of the input/output terminals, or it may damage the PLC.
Check all the wiring prior to power up. To prevent any electromagnetic noise, make sure the PLC is properly grounded . Do NOT touch terminals when power on.
Introduction
Thank you for choosing Delta DVP28SV. 28SV is a 28-point (16 input + 12 output) PLC MPU, offering various instructions and is with 16K Steps program memory, able to connect with all SS/SA/SX/SC/SV series extension models, including digital input/output (max. 512 input/output extension points), analog modules (A/D, D/A tranformation and termperature units) and all kinds of new high-speed extenstion modules. Its 4-group high-speed (200KHz) pulse outputs and the two new 2-axis interpolation instructions satisfy all kinds of applications. DVP28SV is small in size and easy to install.
 Product Profile and Outline
1
2
3
4
5
6
7
14
10
9
8
13
12
11
70
3903
17
18
16
15
60
20
19
21
Unit: mm
1 POWER/RUN/BAT.LOW/ERROR indicator 12 Extension module connection port
2 COM1(RS-232) receiving communication (Rx) indicator 13 DIN rail (35mm)
3 COM2(RS-485) sending communication (Tx) indicator 14 Extension module fastening clip
4 Input/output indicator 15 COM2 (RS-485) communication port (Master/Slave)
5 RUN/STOP switch 16 Power input port
6 VR0: M1178 enabled/D1178 corresponding value 17 3 P removable terminal (standard component)
7 VR1: M1179enabled/D1179 corresponding value 18 Power input connection cable (standard component)
8 Input/output terminal 19 New high-speed extension module connection port
9 COM1(RS-232) program I/O communication port 20 Nameplate
10 DIN rail clip 21 Direct fastening hole
11 Extension module positioning hole
ENGLISH
Specifications
Model
Item
DVP28SV11R DVP28SV11T
Power supply voltage
24V DC (-15% ~ 20%) (with counter-connection protection on the polarity of DC input power)
Inrush current
Max. 2.2A@24V DC
Power consumption
6W
Insulation resistance
> 5M (all I/O point-to-ground: 500V DC)
Noise immunity
ESD (IEC 61131-2, IEC 61000-4-2): 8KV Air Discharge EFT (IEC 61131-2, IEC 61000-4-4): Power Line: 2KV; Digital I/O: 1KV, Analog & Communication I/O: 1KV Damped-Oscillatory Wave: Power Line: 1KV, Digital I/O: 1KV RS (IEC 61131-2, IEC 61000-4-3): 26MHz ~ 1GHz, 10V/m
Earth
The diameter of grounding wire shall not be less than that of the wiring terminal of the power. (When many PLCs are in use at the same time, please make sure every PLC is properly grounded.)
Operation/storage
Operation: 0ºC ~ 55ºC (temperature); 50 ~ 95% (humidity); pollution degree 2 Storage: -40ºC ~ 70ºC (temperature); 5 ~ 95% (humidity)
Vibration/shock immunity
International standards: IEC61131-2, IEC 68-2-6 (TEST Fc)/IEC61131-2 & IEC 68-2-27 (TEST Ea)
Weight (g)
260g 240g
Type Current
Motion level Responding time
Input point
DC (Sink or Source)
24VDC
5mA
X0 ~ X7,X12 ~ X13,X16 ~ X17
OffOn
> 16.5VDC
X10 ~ X11,X14 ~ X15
OffOn
> 18.5VDC
X0 ~ X17
OnOff < 8VDC
Approx. 10 ms (can be adjusted within the range of 10 ~ 60 ms by D1020 and D1021)
Type Current Voltage Max. loading
Responding
time
Mechanical
life
Electrical life
relay-R
1.5A/1 point (5A/COM)
250VAC, > 30VDC
75VA
(inductive)
90 W
(resistive)
Approx.
10 ms
2×107 times
(without
load)
1.5×105 times (5A 30VDC) 5×105 times (3A 120VAC) 3×104 times (5A 250VAC)
Max. 10KHz for Y5, Y7, Y10 ~ Y13
OffOn
20us
OnOff
30us
Output
point
transist
or-T
General: 0.3A/1 point @40ºC High-speed: < 1KHz, 0.3A/1 point @ 40ºC; 1KHz, 30mA/1point@40 ºC
30VDC
Max. 200KHz for Y0, Y1, Y2, Y3, Y4, Y6
OffOn
0.2us
OnOff
0.2us
- -
Model Name & I/O Configuration
Standard Functional MPU
Input/output specification I/O configuration
Input Output Model
Power
Point Type Point Type
Relay Transistor Point
DVP28SV11R
Relay
DVP28SV11T
24VDC
16
DC (Sink
Or
Source)
12
Transistor
S/S X0 X1 X2 X3 X4 X5 X6 X7
S/S X10 X11 X12 X13
X15 X16 X17
C0
Y0
Y1
Y2
Y3
Y4
Y5
Y6
Y7
Y10
Y11
Y12
Y13
C1
C2
C3
S/S
X0 X1 X2 X3 X4 X5 X6
X7 S/S X10 X11 X12 X13
X15 X16 X17
C0
Y0
Y1
C1
C2
Y4
Y5
Y6
Y7
Y12
Y13
C3
Y2 Y3
C4
Y10
Y11
Installation & Wiring
4.1 PLC Mounting Arrangements and Wiring Notes
How to install DIN rail:
DVP-PLC can be secured to a cabinet by using the DIN rail of 35mm in height and 7.5mm in depth. When mounting PLC to DIN rail, be sure to use the end bracket to stop any side-to-side movement of PLC and reduce the chance of wires being loosen. A small retaining clip is at the bottom of PLC. To secure PLC to DIN rail, place the clip onto the rail and gently push it up. To remove it, pull the retaining clip down and gently remove PLC from DIN rail, as shown in figure 1.
How to screw:
Please use M4 screw (see figure 2) according to the dimension of the product. Please install PLC in an enclosure with sufficient space around it to allow heat dissipation (see figure 3).
90
53.2
70
101
109.4
PLC
D
D
DD
D > 50 mm
Figure 1 Figure 2 (Unit: mm) Figure 3
Wiring:
22-1 6AW G
< 1.5m m
1. Use 22-16AWG (1.5mm) single or multiple core wire on I/O wiring terminals. The specification of the terminal is shown in the figure on the left. The PLC terminal screws shall be tightened to 1.95 kg-cm (1.7 in-lbs).
2. DO NOT place the I/O signal wires and power supply wire in the same wiring duct.
3. Use 60/75 ºC copper wires only.
DO NOT install PLC in an environment with:

Dust, smoke, metallic debris, corrosive or flammable gas
High temperature, humidity
Direct shock and vibration
4.2 Wiring Notes
 Power input wiring
The power input of DVP-SV series is DC. When operating SV series, please make sure that:
1. The power is connected to the two terminals, 24V DC and 0V, and the range of power is 20.4 ~ 28.8V DC. If the power voltage is less than 20.4V DC, PLC will stop running, all outputs will go “Off” and ERROR indicator will flash continuously.
2. The power shutdown of less than 10 ms will not affect the operation of PLC. However, power shutdown time that is too long or the drop of power voltage will stop the operation of PLC and all outputs will go “Off”. When the power supply turns normal again, PLC will automatically return to its operation. (Please be aware of the latched auxiliary relays and registers inside PLC when programming.)
24V
2A
S/S
X0 X1 X2
20.4V~28.8V
0V
DC/DC 5V
 Safety wiring
Since DVP28SV is only compatible with DC power supply, Delta power supply modules (DVPPS01/DVPPS02) are suitable power supplies for DVP28SV. Users are suggested to install the protection circuit at the power supply terminal to protect DVPPS01 or DVPPS02.
AC power supply load
Power circuit protection fuse (3A
Power indicator
Emergency stop
This button can cut off the system power supply when accidental emergency takes place.
System circuit isolation device
The device is made of electromagnetic contactor and relay as the switch to prevent the instability of system when the power is intermittently supplied.
DVPPS01/DVPPS02 (main processing unit)
Earth
MC
MC
NL
1
1
2
3
4
5
6
7
8
Guard Limit
MC
Power supply AC: 100 ~ 240V AC, 50/60Hz
 Input point wiring
There are two types of DC inputs, SINK and SOURCE.
Input point loop equivalent circuit Wiring loop DC Signal IN
S/S
X0
Sinking
SINK mode
(common port for current
input S/S)
24VDC
24G
X0
S/S
+24V
SINK
+5V
24G S/SX0 X1 X2+24V
Sink Type
Input point loop equivalent circuit Wiring loop DC Signal IN
S/S
X0
Sourcing
SOURCE mode
(common port for current
output S/S)
24VDC
24G
X0
S/S
+24V
SOURCE
+5V
24G S/SX0 X1 X2+24V
Source Type
 Output point wiring
Y0
RY
LED
C0
LOAD
POWER
DVP-**-**-11-R
RELAY OUTPUT
DVP-**-**-11-T
TRANSISTOR OUTPUT
LED
Y0
C0
LOAD
< 0.3A
T R G
1. DVP-SV series have two output modules, relay and transistor. See “Specifications” for their specifications.
2. Be aware of the connection of shared terminals when wiring output terminals.
3. Output terminals, Y0, Y1, and Y2, of relay models use C0 common port; Y3, Y4, and Y5 use C1 common port; Y6, Y7, and Y10 use C2 common port; Y11, Y12, and Y13 use C3 common port, as shown in the next page.
C0 Y0 Y 1 Y2 C 1 Y3 Y4 Y 5 C2 Y6 Y7 Y10 C3Y11 Y12 Y13
When output points are enabled, their corresponding indicators on the front panel will be on.
4. Output terminals, Y0 and Y1, of transistor models use C0 common port; Y2 and Y3 use C1 common port; Y4 and Y5 use C2 common port; Y6 and Y7 use C3 common p ort; Y10, Y11, Y12 and Y13 use C4 common port, as shown below.
C0Y0Y1C4Y10
Y11
Y12C1Y2Y3C2Y4Y5C3Y6Y7Y13
5. Isolation circuit: The optical coupler is used to isolate signals between the circuit i nside PLC and input modules.
 Relay (R) contact circuit wiring
Y0
RY
LED
C0
LOAD
POWER
DVP-**-**-**-R
RELAY OUTPUT
2
3
1
5
C0 Y0 Y1 C1 Y3 Y4C2Y6 Y7
4
MC1 MC2
7
10
3
2
8
9
6
R
C
Flywheel diode (SB360 3A 60V): To extend the life span of contact
Emergency stop: Uses external switch
Fuse: Uses 5 ~ 10A fuse at the common port of output contacts to protect the output circuit.
Varistor: To reduce the interference on AC load (R=100~120, C=0.1~0.2uF)
Empty terminal: not in use
DC power supply
Neon indicator
AC power supply
Incandescent light (resistive load)
Manually exclusive output: Uses external circuit and forms an interlock, together with the PLC internal program, to ensure safety protection in case of any unexpected errors.
 Transistor (T) contact circuit wiring
DVP-**-**-**-T
TRANSISTOR OUTPUT
LED
Y0
C0
LOAD
0000....5555AAAA
MC1
MC2
2
3
1
C0 Y0 Y1 C4 Y10Y11 Y12Y 13
545
3
4
DC power supply
Emergency stop
Circuit protection fuse
Flywheel diode (SB360 3A 60V) + inductive load
Manually exclusive output: Uses external circuit and forms an interlock, together with the PLC internal program, to ensure safety protection in case of any unexpected errors.
使EH
DVP-PLC
DVP-PLC
(O PEN TYPE)
使使/
DVP
SV2816
+ 12
PLC
16K Steps
SS/SA/SX/SC/SV
//
512
A/DD/A
200KHz
滿
1
2
3
4
5
6
7
14
10
9
8
13
12
11
70
3903
17
18
16
15
60
20
19
21
mm
1
12
2 COM1 (RS-232)
(Rx)
13 DIN
35mm
3 COM2 (RS-485)
(Tx)
14
4
/
15
COM2 (RS-485)
(Master/Slave)
5
RUN/STOP
16
6 VR0M1178/D1178
17 3 P
7 VR1M1179/D1179
18
8 /
19
9
COM1 (RS-232)
/
20
10
DIN
21
11
DVP28SV11R DVP28SV11T
24V DC (-15% ~ 20%)
MAX 2.2A @24V DC
2.5A/30V DC
(Polyswitch)
6W
5 M (
5 00V DC)
ESD(IEC 61131-2, IEC 61000-4-2): 8KV Air Discharge EFT(IEC 61131-2, IEC 61000-4-4): Power Line: 2KV, Digital I/O: 1KV, Analog & Communication I/O: 1KV Damped-Oscillatory Wave: Power Line: 1KV, Digital I/O: 1KV RS(IEC 61131-2, IEC 61000-4-3): 26MHz ~ 1GHz, 10V/m
PLC
使
0ºC ~ 55ºC
50 ~ 95%
2
-40ºC ~ 70ºC
5 ~ 95%
IEC61131-2, IEC 68-2-6 (TEST Fc)/ IEC61131-2 & IEC 68-2-27 (TEST Ea)
, g 26 0g 240g
SINKSOURCE
-R
-T
24VDC 5mA
1.5A/15A/COM
0.3A/1@40ºC
> 1KHz, 0.3A/1
@40ºC
1KHz, 30mA/1
@40ºC
X0~X7,X12~X13,X16~X17 OffOn 16.5VDC
250VAC, 30VDC
30VDC
X10~X11,X14~X15 OffOn 18.5VDC
75VA
90W
Y5,Y7,Y10 ~ Y13
10KHz
Y0,Y1,Y2,Y3,Y4,Y6
200KHz
X0~X17 OnOff 8VDC
10 ms
OffOn 20us OnOff 30us
OffOn 0.2us OnOff 0.2us
2×10
7
(
)
-
10 msD1020D1021
10~60 ms
調
1.5×10
5
(5A 30VDC) 5×10
5
(3 A 120VAC)
3×10
4
(5 A 250VAC)
-
I/O
I/O
DVP28SV11R
DVP28SV11T
24VDC
16
Sink
Source
12
S/S X0 X1 X2 X3 X4 X5 X6 X7 S/S X10 X11 X12 X13
X15 X16 X17
C0
Y0
Y1 Y2
Y3
Y4
Y5
Y6
Y7
Y10
Y11
Y12
Y13
C1
C2 C3
S/S X0 X1 X2 X3 X4 X5 X6 X7 S/S
X10
X11 X12 X13
X15 X16 X17
C0
Y0 Y1
C1
C2 Y4
Y5 Y6
Y7
Y12 Y13
C3
Y2 Y3
C4
Y10
Y11
4.1
DIN
35mmDIN
PLC
PLC
PLCPLC
PLC
使M4
PLC
PLC
90
53.2
70
101
109.4
PLC
D
D
DD
D > 50 mm
22-16AWG
< 1.5mm
1. /
使
22-16AWG (1.5mm)
PLC
1.95 kg-cm (1.7 Ib-in)
2.
3.
使
60/75 ºC
PLC
4.2
SV
使
1.
24VDC0V
20.4 ~ 28.8V DC
20.4V DCPLC
OffERROR LED
2.
10msPLC
使
PLC
Off
PLC
PLC
使
使
24V
2A
S/S X0 X1 X2
20.4V~28.8V
0V
DC/DC
5V
DVP28SV
DC Only
(DVPP S01/DVPPS02)
DVP28SV
DVPPS01/DVPPS02
(3A)
使
DVPPS01/DVPPS02
MC
MC
NL
1
1
2
3
4
5
6
7
8
Guard Limit
MC
(AC)100 ~ 240V AC, 50/60Hz
DC
SINKSOURCE
DC Signal IN
S/S
X0
Sinking
SINK
S/S
24VDC
24G
X0
S/S
+24V
SINK
+5V
24G S/SX0 X1 X2+24V
Sink Type
DC Signal IN
S/S
X0
Sourcing
SOURCE
S/S
24VDC
24G
X0
S/S
+24V
SOURCE
+5V
24G S/SX0 X1 X2+24V
Source Type
Y0
RY
LED
C0
LOAD
POWER
DVP-**-**-11-R
RELAY OUTPUT
DVP-**-**-11-T
TRANSISTOR OUTPUT
LED
Y0
C0
LOAD
< 0.3A
T R G
1. DVP-SPLC
2.
3.
Y0Y1Y2C0Y3Y4Y5C1Y6Y7
Y10C2
Y11Y12Y13C3
C0 Y0 Y 1 Y2 C 1 Y3 Y4 Y 5 C2 Y6 Y7 Y10 C3Y11 Y12 Y13
4.
Y0Y1C0Y2Y3C1Y4Y5C2Y6Y7
C3
Y10Y11Y12Y13C4
C0Y0Y1C4Y10
Y11
Y12C1Y2Y3C2Y4Y5C3Y6Y7Y13
5.
PLC
使
(R)
Y0
RY
LED
C0
LOAD
POWER
DVP-**-**-**-R
RELAY OUTPUT
2
3
1
5
C0 Y0 Y1 C 1 Y3 Y4C2Y6 Y7
4
MC1
MC2
7
10
3
2
8
9
6
R
C
(SB360 3A 60V)
使
使
5 ~ 10A
(R = 100 ~ 120, C = 0.1 ~ 0.24uF)
使
PLC
(T)
DVP-**-**-**-T
TRANSISTOR OUTPUT
LED
Y0
C0
LOAD
0000....5555AAAA
MC1
MC2
2
3
1
C0 Y0 Y1 C4 Y10Y11 Y 12 Y 13
545
3
4
(SB360 3A 60V) +
PLC
使线EH
DVP-PLC
DVP-PLC
(O PEN TYPE)
使使 线
线
DVP
SV28
16
+ 12
PLC
16K Steps
SS/SA/SX/SC/SV
/
512
A/DD/A
200KHz
1
2
3
4
5
6
7
14
10
9
8
13
12
11
70
3903
17
18
16
15
60
20
19
21
mm
1
12
2
COM1 (RS-232)
(Rx)
13
DIN (3 5mm)
3
COM2 (RS-485)
(Tx)
14
4
/
15
COM2 (RS-485)
(Master/Slave)
5 RUN/STOP 16
6
VR0M1178/D1178
17
3 P
(
)
7
VR1M1179/D1179
18
线 (
)
8
/
19
9
COM1 (RS-232)
/
20
10
DIN
21
11
DVP28SV11R DVP28SV11T
24V DC (-15% ~ 20%)
MAX 2.2A @24V DC
2.5A/30V DC
(Po lyswitch)
6W
5 M
500V DC
ESD (IEC 61131-2, IEC 61000-4-2): 8KV Air Discharge EFT (IEC 61131-2, IEC 61000-4-4): Power Line: 2KV, Digital I/O: 1KV, Analog & Communication I/O: 1KV Damped-Oscillatory Wave: Power Line: 1KV, Digital I/O: 1KV RS(IEC 61131-2, IEC 61000-4-3): 26MHz ~ 1GHz, 10V/m
线线线线
PLC
使
0ºC ~ 55º C
50 ~ 95%
湿
2
-40ºC ~ 70ºC
5 ~ 95%
湿
IEC61131-2, IEC 68-2-6 (TEST Fc)/ IEC61131-2 & IEC 68-2-27 (TEST Ea)
, g
260g 260g
SINKSOURCE
-R
-T
24V DC 5mA
1.5A/15A/COM
0.3A/1@40ºC
> 1KHz, 0.3A/1
@40ºC
1KHz, 30mA/1
@40ºC
X0 ~ X7,X12 ~ X13, X16 ~ X17 OffOn 16.5V DC
250VAC, 30VDC
30VDC
X10 ~ X11,X14 ~ X15 OffOn 18.5V DC
75VA
90W
Y5,Y7,Y10 ~ Y13
10KHz
Y0,Y1,Y2,Y3,Y4,Y6
200KHz
X0 ~ X17 OnOff 8VDC
10 ms
OffOn 20us OnOff 30us
OffOn 0.2us OnOff 0.2us
寿
2×10
7
-
10 msD1020D1021
10~60 ms
寿
1.5×10
5
(5A 30VDC)
5×10
5
(3A 120VAC)
3×10
4
(5A 250VAC)
-
I/O
I/O
DVP28SV11R
DVP28SV11T
24VDC
16
Sink
Source
12
S/S X0 X1 X2 X3 X4 X5 X6 X7 S/S X10 X11 X12 X13
X15 X16 X17
C0
Y0
Y1
Y2
Y3
Y4
Y5
Y6
Y7
Y10
Y11
Y12
Y13
C1
C2
C3
S/S
X0 X1 X2 X3 X4 X5 X6
X7 S/S X10 X11 X12 X13
X15 X16 X17
C0
Y0
Y1
C1
C2
Y4
Y5
Y6
Y7
Y12
Y13
C3
Y2 Y3
C4
Y10
Y11
4.1
线
DIN
35mmDIN
PLC
PLC
PLC
PLC
PLC
使M4
PLC
PLC
90
53.2
70
101
109.4
PLC
D
D
DD
D > 50 mm
线
线线
线
22-16AWG
< 1.5mm
1.
线使
22-16AWG (1.5mm)
线
线
PLC
1.95 kg-cm (1.7 Ib-in)
2.
线线线线
3.
使
60/75 ºC
线
PLC
4.2
线
SV
使
1.
24VDC0V
20.4VDC ~ 28.8VDC
20.4VDC
PLC
OffERROR LED
2.
10ms
PLC
使
PLC
Off
PLC
PLC
使
使
24V
2A
S/S
X0 X1 X2
20.4V~28.8V
0V
DC/DC
5V
线
DVP28SV
DC Only
(DVPP S01/DVPPS02)
DVP28SV
DVPPS01/DVPPS02
(3A)
使
DVPPS01/DVPPS02
MC
MC
NL
1
1
2
3
4
5
6
7
8
Guard Limit
MC
(AC)100 ~ 240V AC, 50/60Hz
线
DC
SINKSOURCE
线
DC Signal IN
S/S
X0
Sinking
SINK
S/S
24VDC
24G
X0
S/S
+24V
SINK
+5V
24G
S/S
X0 X1 X2+24V
Sink Type
线
DC Signal IN
S/S
X0
Sourcing
SOURCE
S/S
24VDC
24G
X0
S/S
+24V
SOURCE
+5V
24G
S/S
X0 X1 X2+24V
Source Type
线
Y0
RY
LED
C0
LOAD
POWER
DVP-**-**-11-R
RELAY OUTPUT
DVP-**-**-11-T
TRANSISTOR OUTPUT
LED
Y0
C0
LOAD
< 0.3A
T R G
1. DVP-SPLC
2.
线
3.
Y0Y1Y2C0
Y3Y4Y5C1
Y6Y7
Y10
C2
Y11Y12Y13
C3
C0Y0Y1Y2C1Y3Y4Y5C2Y6Y7
Y10C3Y11
Y12
Y13
4.
Y0Y1C0
Y2Y3C1
Y4Y5
C2
Y6Y7
C3
Y10Y11Y12Y13
C4
C0 Y0 Y1 C4Y10 Y11 Y12C1 Y2 Y3 C2 Y4 Y5 C3 Y6 Y7 Y13
5.
PLC
使
(R)
线
Y0
RY
LED
C0
LOAD
POWER
DVP-**-**-**-R
RELAY OUTPUT
2
3
1
5
C0 Y0 Y1 C 1 Y3 Y4C2Y6
Y7
4
MC1 MC2
7
10
3
2
8
9
6
R
C
(SB360 3A 60V)
寿
使
使
5 ~ 10A
(R = 100 ~ 120, C = 0.1 ~ 0.24uF)
使
PLC
(T)
线
DVP-**-**-**-T
TRANSISTOR OUTPUT
LED
Y0
C0
LOAD
0000....5555AAAA
MC1
MC2
2
3
1
C0 Y0 Y1 C4 Y10 Y11 Y12 Y13
545
3
4
(SB360 3A 60V) +
PLC
Loading...