Delta INSPIRE Ultra 20 Instruction Manual

MINI SPLIT INVERTER- INSPIRE Ultra 20
INSTRUCTION MANUAL
26WD012I24-035DWKXZ
WARNING!
Read and follow all safety precautions in Instruction Manual - improper use can cause serious injury.
www.delta-dct.com
This appliance is not intended for use by persons (including children) with reduced physical,
sensory or mental capabilities or lack of experience and knowledge, unless they have been given supervision or instruction concerning use of the appliance by a person responsible for their safety. Children should be supervised to ensure they are away from the appliance.
Do not dispose this product as unsorted municipal waste. Collection of such waste separately for special treatment is necessary.
Content
Operation Notices
Precautions............................................................................................................1
Parts name ............................................................................................................6
Screen Operation Guide
Buttons on remote controller .................................................................................7
Introduction for icons on display screen ................................................................7
Introduction for buttons on remote controller .........................................................8
Function introduction for combination buttons .....................................................12
Operation guide ...................................................................................................13
Replacement of batteries in remote controller .....................................................13
Emergency operation ..........................................................................................14
Maintenance
Clean and maintenance.......................................................................................14
Malfunction
Malfunction analysis ............................................................................................17
Installation Notice
Installation dimension diagram ............................................................................21
Tools for installation .............................................................................................22
Selection of installation location ..........................................................................22
Requirements for electric connection ..................................................................23
Installation
Installation of indoor unit......................................................................................24
Installation of outdoor unit ...................................................................................29
Vacuum pumping .................................................................................................32
Leakage detection ...............................................................................................32
Check after installation ........................................................................................33
Test and operation
Test operation ......................................................................................................33
Attachment
Conguration of connection pipe .........................................................................34
Pipe expanding method .......................................................................................36
1
Precautions
Warning
Do not connect air conditioner to multi-purpose socket.
This appliance can be used by children aged from 8
Operation and Maintenance
If the supply cord is damaged, it must be replaced by the manufacturer, its service agent or similarly qualified persons in order to avoid a hazard.
Do not spray water on indoor unit. It may cause electric shock or malfunction.
Otherwise, it may cause fire hazard.
Children shall not play with the appliance. Cleaning and user maintenance shall not be made by
children without supervision.
years and above and persons with reduced physical, sensory or mental capabilities or lack of experience and knowledge if they have been given supervision or instruction concerning use of the appliance in a safe way and understand the hazards involved.
Do not wash the air conditioner with water to avoid electric shock.
After removing the filter, do not touch fins to avoid injury. Do not use fire or hair dryer to dry the filter to avoid
deformation or fire hazard.
Do disconnect power supply when cleaning air conditioner. Otherwise, it may cause electric shock.
Do not block air outlet or air inlet. It may cause malfunction.
remote controller may be broken.
Power cord is overheating or damaged.
There’s abnormal sound during operation.
Circuit break trips off frequently.
Air conditioner gives off burning smell.
Indoor unit is leaking.
contact the dealer or qualified professionals for service.
When turning on or turning off the unit by emergency operation switch, please press this switch with an insulating object other than metal.
outlet. It may cause personal injury or damage.
2
Precautions
Warning
conditioner and disconnect power immediatelyand then
If the air conditioner operates under abnormal conditions, it may cause malfunctionelectric shock or fire hazard.
Do not spill water on the remote controller, otherwise the
electric shock or damage. Please contact dealer when you need to repair air conditioner.
Do not repair air conditioner by yourself. It may cause
objects. It may cause damage or personal injury.
Do not step on top panel of outdoor unit, or put heavy
When below phenomenon occurs, please turn off air
Do not extend fingers or objects into air inlet or air
Maintenance must be performed by qualified professionals. Otherwise, it may cause personal injury
or damage.
Do install the circuit break. If not, it may cause malfunction.
of at least 3mm in all poles should be connected in fixed wiring.
magnet buckle
and heating buckle function, it can protect
the circuit-short and
overload.
power supply circuit and circuit break.
3
Precautions
Warning
note
the following table.Air switch should be included
Make sure the power supply matches with the requirement of air conditioner.Unstable power supply or incorrect wiring or malfunction. Please install proper power supply cables before using the air conditioner.
An all-pole disconnection switch having a contact separation
Must follow the electric safety regulations when installing the unit.
grounding wire of power socket.
Properly connect the live wire, neutral wire and
any work related to electricity and safety.
Be sure to cut off the power supply before proceeding
Including an circuit break with suitable capacity, please
Air Conditioner should be properly grounded. Incorrect
Don't use unqualified power cord.
grounding may cause electric shock.
According to the local safety regulations, use qualified
Installation must be performed by qualified professionals. Otherwise, it may cause personal injury or damage.
Attachment
Installation must be performed in accordance with the
persons in order to avoid a hazard.
must be properly grounding with specialized grounding device by a professional. Please make sure it is always grounded effectively, otherwise it may cause electric shock.
The appliance must be positioned so that the plug is accessible.
If the length of power connection wire is insufficientplease contact the supplier for a new one. Avoid extending the wire by yourself.
All wires of indoor unit and outdoor unit should be connected by a professional.
national wiring regulations.
requirement of NEC and CEC by authorized personnel only
4
Precautions
Warning
wire, which can't be used for other purposes.
The grounding resistance should comply with national electric safety regulations.
The air conditioner is the first class electric appliance. It
keep the interconnection cable away from the copper tube.
The temperature of refrigerant circuit will be high, please
the manufacturer, its service agent or similarly qualified
If the supply cord is damaged, it must be replaced by
The yellow-green wire in air conditioner is grounding
The appliance shall be installed in accordance with
Do not put through the power before finishing installation.
The indoor unit should be installed close to the wall
reachable after finishing installation.
far away from animals or plants.If it is unavoidable, please add the fence for safety purpose.
5
Precautions
Warning
place, only the qualified person can perform the work. Otherwise, it may cause personal injury or damage.
If you need to relocate the air conditioner to another
must be installed in the line.
For the air conditioner without plug, an circuit break
Select a location which is out of reach for children and
For the air conditioner with plug,the plug should be
Working temperature range
Indoor side DB/WB(℉) Outdoor side DB/WB(℉)
Maximum cooling 95/75 115/86
Maximum heating 70/59 70/--
The operating temperature range (outdoor temperature) for cooling unit is
0.4~109.4.
6
(Display content or position may be different from above graphics, please refer to actual products)
Parts name
Indoor Unit
Outdoor Unit
air inlet panel
lter
aux.button
horizontal louver
air outlet
heating indicator
temp. indicator
cooling indicator
power indicator
receiver window
drying indicator
display
remote control
Notice:
Actual product may be different from above graphics, please refer to actual
products.
air inlet
Connection wire
air outlet
7
Buttons on remote controller
Introduction for icons on display screen
1
2
5
7 9
11
10 12
8
6
4
3
1
2
3
4
5
6
7
8
9
10
11 12
ON/OFF button
MODE button
+/- button
FAN button
button
X-FAN button
Note: X-FAN is the same with BLOW
TEMP button
TURBO button
LIGHT button SLEEP button
TIMER ON/TIMER OFF button
CLOCK button
Send signal
Turbo mode
Set temperature
Set time TIMER ON / TIMER OFF
Child lock
Up & down swing
Set fan speed
X-fan mode
Light
Temp. display type
:Set temp.
:Outdoor ambient temp.
:Indoor ambient temp.
Sleep mode
Clock
Heat mode
Fan mode
Dry mode
Cool mode
Auto mode
Operation mode
8
● When selecting auto mode, air conditioner will operate automatically according to ex-factory setting. Set temperature can’t be adjusted and will not be displayed as well. Press "FAN" button can adjust fan speed. Press " " button can adjust fan blowing angle.
● After selecting cool mode, air conditioner will operate under cool mode. Cool indicator " "on indoor unit is ON. Press "+" or "-" button to adjust set tempe­ rature. Press "FAN" button to adjust fan speed. Press " " button to adjust fan blowing angle.
● When selecting dry mode, the air conditioner operates at low speed under dry mode. Dry indicator " " on indoor unit is ON. Under dry mode, fan speed can’t be adjusted. Press " " button to adjust fan blowing angle.
● When selecting fan mode, the air conditioner will only blow fan, no cooling and no heating. All indicators are OFF. Press "FAN" button to adjust fan speed. Press " " button to adjust fan blowing angle.
● When selecting heating mode, the air conditioner operates under heat mode. Heat indicator " " on indoor unit is ON. Press "+" or "-" button to adjust set temperature. Press "FAN" button to adjust fan speed. Press " " button to adjust fan blowing angle. (Cooling only unit won’t receive heating mode signal. If setting heat mode with remote controller, press ON/OFF button can’t start up the unit).
Note:
● For preventing cold air, after starting up heating mode, indoor unit will delay 1~5 minutes to blow air (actual delay time is depend on indoor ambient temperature).
● Set temperature range from remote controller: 16~30°C(61~86°F); Fan speed: auto, low speed, medium speed, high speed.
Introduction for buttons on remote controller
Note:
● After putting through the power, the air conditioner will give out a sound. Operation indictor " " is ON (red indicator). After that, you can operate the air conditioner by using remote controller.
ON/OFF button
MODE button
1
2
Press this button can turn on or turn off the air conditioner. After turning on the air conditioner, operation indicator " "on indoor unit’s display is ON (green indicator. The colour is different for different models), and indoor unit will give out a sound.
Press this button to select your required operation mode.
AUTO COOL FANDRY HEAT
9
Introduction for buttons on remote controller
FAN button
4
Pressing this button can set fan speed circularly as: auto (AUTO), low( ) ,medium ( ), high( ).
Auto
Note:
● Under AUTO speed, air conditioner will select proper fan speed automatically according to ex-factory setting.
● Fan speed under dry mode is low speed.
5
Press this button can select up&down swing angle. Fan blow angle can be selected circularly as below:
● When selecting " ", air conditioner is blowing fan automatically. Horizontal louver will automatically swing up & down at maximum angle.
● When selecting "
、 、
● When selecting "
● Hold " "button above 2s to set your required swing angle. When reaching your required angle, release the button.
Note:
● "
" may not be available. When air conditioner receives this signal, the
air conditioner will blow fan automatically.
button
no display (horizontal louvers stops at current position)
+/- button
3
● Press "+" or "-" button once increase or decrease set temperature 1
(1°F).
Holding "+" or "-" button, 2s later, set temperature on remote controller will
tor on indoor unit will change accordingly. (Temperature can’t be adjusted under auto mode)
● When setting TIMER ON, TIMER OFF or CLOCK, press "+" or "-" button to adjust time. (Refer to CLOCK, TIMER ON, TIMER OFF buttons) When setting TIMER ON, TIMER OFF or CLOCK, press "+" or "-" button to adjust time. (Refer to CLOCK, TIMER ON, TIMER OFF buttons)
10
Press this button to set clock time. " " icon on remote controller will blink. Press "+" or "-" button within 5s to set clock time. Each pressing of "+" or "-" button, clock time will increase or decrease 1 minute. If hold "+" or "-" button, 2s later, time will change quickly. Release this button when reaching your required time. Press
Note:
● Clock time adopts 24-hour mode.
The interval between two operation can’t exceeds 5s. Otherwise, remote contro-
ller will quit setting status. Operation for TIMER ON/TIMER OFF is the same.
CLOCK button
6
Introduction for buttons on remote controller
TIMER ON / TIMER OFF button
7
TIMER ON button "TIMER ON" button can set the time for timer on. After pressing this button, " " icon disappears and the word "ON" on remote controller blinks. Press "+" or "-" button to adjust TIMER ON setting. After each pressing "+" or "-" button, TIMER ON setting will increase or decrease 1min. Hold "+" or "-" button, 2s later, the time will change quickly until reaching your required time.
resumes displaying. Cancel TIMER ON: Under the condition that TIMER ON is started up, press "TIMER ON" button to cancel it.
TIMER OFF button "TIMER OFF" button can set the time for timer off. After pressing this button," " icon disappears and the word "OFF" on remote controller blinks. Press "+" or "-" button to adjust TIMER OFF setting. After each pressing "+" or "-" button, TIMER OFF setting will increase or decrease 1min. Hold "+" or "-" button, 2s later, the time will change quickly until reaching your required time. Press "TIMER OFF" word "OFF" will stop blinking. " " icon resumes displaying. Cancel TIMER OFF. Under the condition that TIMER OFF is activating up, press "TIMER OFF" button to cancel it.
Note:
● Under on and off status, you can set TIMER OFF or TIMER ON simultaneously.
● Before setting TIMER ON or TIMER OFF, please adjust the clock time.
After activating up TIMER ON or TIMER OFF, set the constant circulating valid.
After that, air conditioner will be turned on or turned off according to setting time. ON/OFF button has no effect on setting. If you don’t need this function, please use remote controller to cancel it.
11
TEMP button
9
Introduction for buttons on remote controller
By pressing this button, you can see indoor set temperature, indoor ambient temp­erature or outdoor ambient temperature on indoor unit’s display. The setting on
remote controlleris selected circularly as below:
no display
● When selecting " " or no display with remote controller, temperature indicator
on indoor unit displays set temperature.
● When selecting " " with remote controller, temperature indicator on indoor unit
displays indoor ambient temperature.
● When selecting " " with remote controller, temperature indicator on indoor unit
displays outdoor ambient temperature.
Note:
Outdoor temperature display is not available for some models. At that time, indoor
unit receives " "signal, while it displays indoor set temperature.
● It’s defaulted to display set temperature when turning on the unit.There is no
display in the remote controller.
● Only for the models whose indoor unit has dual-8 display.
● When selecting displaying of indoor or outdoor ambient temperature, indoor
temperature indicator displays corresponding temperature and automatically turn
to display set temperature after three or ve seconds.
X-FAN button
8
Press this button under cool and dry mode to start up x-fan function, and " " icon on remote controller will be displayed. Press this button again to cancel x-fan
function, and " "icon will disappear.
Note:
● When x-fan function is on, if the air conditioner is turned off, indoor fan will still
operate at low speed for a while to blow the residual water inside the air duct.
● During x-fan operation, press X-FAN button to turn off x-fan function. Indoor fan
will stop operation immediately.
TURBO button
10
Under COOL or HEAT mode, press this button to turn to quick COOL or quick HEAT mode. " " icon is displayed on remote controller. Press this button again
to exit turbo function and " " icon will disappear.
12
Function introduction for combination buttons
Child lock function
Press "+" and "-" simultaneously to turn on or turn off child lock function. When
child lock function is on, " " icon is displayed on remote controller. If you operate the remote controller, the " " icon will blink three times without sending signal to the unit.
Temperature display switchover function
Under OFF status, press "-" and "MODE" buttons simultaneously to switch temp-
erature display between ℃ and ℉.
Introduction for buttons on remote controller
Press this button to turn off display light on indoor unit. " " icon on remote controller disappears. Press this button again to turn on display light. " " icon is displayed.
Under COOL, HEAT or DRY mode, press this button to start up sleep function.
" " icon is displayed on remote controller. Press this button again to cancel sleep function and " " icon will disappear.
SLEEP button
LIGHT button
11
12
13
1.
After putting through the power, press "ON/OFF" button on remote controller to
turn on the air conditioner.
2.
Press "MODE" button to select your required mode: AUTO, COOL, DRY, FAN,
HEAT.
3.
Press "+" or "-" button to set your required temperature. (Temperature can’t be
adjusted under auto mode).
4.
Press "FAN" button to set your required fan speed: auto, low, medium and high
speed.
5.
Press " " button to select fan blowing angle.
Operation guide
Replacement of batteries in remote controller
1. Press the back side of remote controller marked
with " ", as shown in the g, and then push out
the cover of battery box along the arrow direction.
2. Replace two 7# (AAA 1.5V) dry batteries, and make sure the position of "+" polar and "-" polar
are correct.
3. Reinstall the cover of battery box.
signal sender battery
Cover of battery box
remove
reinstall
Note:
● During operation, point the remote control signal sender at the receiving
window on indoor unit.
● The distance between signal sender and receiving window should be no
more than 8m, and there should be no obstacles between them.
● Signal may be interfered easily in the room where there is uorescent lamp
or wireless telephone; remote controller should be close to indoor unit during operation.
● Replace new batteries of the same model when replacement is required.
● When you don’t use remote controller for a long time, please take out the
batteries.
● If the display on remote controller is fuzzy or there’s no display, please
replace batteries.
14
Emergency operation
If remote controller is lost or damaged, please use auxiliary button to turn on or turn off the air conditioner. The operation in details are as below:
As shown in the g. Open panel, press aux. button to turn on or turn off the
air conditioner. When the air conditioner is turned on, it will operate under auto mode.
aux. button
panel
Clean and maintenance
Note:
■ Turn off the air conditioner and disconnect the power before cleaning the air
conditioner to avoid electric shock.
■ Do not wash the air conditioner with water to avoid electric shock.
■ Do not use volatile liquid to clean the air conditioner.
Clean surface of indoor unit
When the surface of indoor unit is dirty, it is recommended to use a soft dry cloth or wet cloth to wipe it.
Note:
● Do not remove the panel when cleaning it.
15
Clean and maintenance
1
2
3
4
Open panel
Pull out the panel to a certain ● Use dust catcher or water to
the water (below 45
) to clean
it, and then put it in a shady and cool place to dry.
panel cover tightly.
Note:
operating environment, cleaning frequency can be increased.
16
Clean and maintenance
Checking before operating-season
Checking after operating-season
1. Check whether air inlets and air outlets are blocked.
2. Check whether circuit break, plug and socket are in good condition.
4. Check whether mounting bracket for outdoor unit is damaged or corroded. If yes, please contact dealer.
5. Check whether drainage pipe is damaged.
1. Disconnect power supply.
3. Check whether mounting bracket for outdoor unit is damaged or corroded. If yes, please contact dealer.
Notice for recovery
1. Many packing materials are recyclable materials. Please dispose them in appropriate recycling unit.
2. If you want to dispose the air conditioner, please contact local dealer or consultant service center for the correct disposal method.
17
Malfunction analysis
General Malfunction analysis
Please check below items before asking for maintenance. If the malfunction still
Phenomenon Check items Solution
Indoor unit can’t receive remote controller’s signal or remote controller has no action.
● Whether it's interfered severely
(such as static electricity,stable voltage)?
● Whether remote controller is
within the signal receiving range?
● Whether there are obstacles?
● Whether remote controller is
pointing at the receiving window?
● Is sensitivity of remote contro­ ller low; fuzzy display and no display?
● No display when operating
remote controller?
● Fluorescent lamp in room?
● Pull out the plug. Reinsert
the plug after about 3min, and then turn on the unit again.
● Signal receiving range is 8m.
● Remove obstacles.
Select proper angle and point
the remote controller at the re-
ceiving window on indoor unit.
● Check the batteries. If the
power of batteries is too low, please replace them.
Take the remote controller close to indoor unit.
and then try it again.
● Check whether remote cont-
roller appears to be damaged.
If yes, replace it.
No air
emitted from indoor unit
Air inlet or air outlet of indoor unit is blocked?
● Eliminate obstacles.
● Under heating mode, indoor
temperature is reached to set temperature?
After reaching to set temper- ature, indoor unit will stop bl-
owing out air.
● Heating mode is turned on just
now?
● In order to prevent blowing
out cold air, indoor unit will be
started after delaying for sev­ eral minutes, which is a nor-
mal Malfunction.
18
Malfunction analysis
● Power failure?
● Is plug loose?
● Circuit breaker trips off or fuse is burnt out?
● Wiring has malfunction?
● Unit has restarted immediately after stopping operation?
● Whether the function setting for remote controller is correct?
● Reset the function.
● Wait for 3min, and then turn on the unit again.
● Ask professional to replace it.
● Ask professional to replace circuit breaker or fuse.
● Reinsert the plug.
● Wait until power is restored.
Air condit­ioner can’t operate
Mist appeared from indoor unit’s air outlet
● Indoor temperature and hum­ idity is high?
● Because indoor air is cooled rapidly. After a while, indoor temperature and humidity will be decreased and mist will disappear.
Phenomenon Check items Solution
Set temper­ature can’t be adjusted
● Unit is operating under auto mode?
Temperature can’t be adju- sted under auto mode. Please switch the operation mode if you need to adjust temperature.
Your required temperature exceeds the set temperature range?
● Set temperature range: 16℃~30℃.
Cooling (heating) effect is not good.
Voltage is too low?
● Wait until the voltage resume to normal.
● Filter is dirty?
● Set temperature is in proper range?
Adjust temperature to proper range.
● Door or window are open? ● Close doors and windows.
19
Phenomenon Check items Solution
Odours are emitted
● Whether there’s odour source,
such as furniture and cigarette, etc.
● Eliminate the odour source.
● Clean the lter.
Air conditio-
ner operates abnormally
● Whether there’s interference,
such as thunder, wireless devices, etc.
● Disconnect power, put back
power, and then turn on the unit again.
Outdoor unit has vapor
● Heating mode is turned on?
● During defrosting under he-
ating mode, it may generate vapor, which is a normal phenomenon.
“Water
owing”
noise
● Air conditioner is turned on or
turned off just now?
● The noise is the sound of refrigerant owing inside
the unit, which is a normal phenomenon.
Cracking noise
● Air conditioner is turned on or
turned off just now?
● This is the sound of friction
caused by expansion and/or contraction of panel or other parts due to the change of temperature.
Malfunction analysis
20
Malfunction analysis
Error Code
● When air conditioner status is abnormal, temperature indicator on indoor unit will blink to display corresponding error code. Please refer to below list for identic-
ation of error code.
Indoor display
Error code
Above indicator diagram is only
for reference. Please refer to actual product for the actual indicator and position.
■ When below phenomenon occurs, please turn off air conditioner and discon­ nect power immediately, and then contact the dealer or qualied professionals
for service.
● Power cord is overheating or damaged.
● There’s abnormal sound during operation.
● Circuit break trips off frequently.
● Air conditioner gives off burning smell.
● Indoor unit is leaking.
■ Do not repair or ret the air conditioner by yourself.
■ If the air conditioner operates under abnormal conditions, it may cause malfunction, electric shock or re hazard.
Warning
Error code
H1
E5
U8
H6
C5 F1
F2
Troubleshooting
Means defrosting status. It’s the normal phenomenon.
It can be eliminated after restarting the unit. If not,please
contact qualied professionals for service.
It can be eliminated after restarting the unit. If not,please
contact qualied professionals for service.
It can be eliminated after restarting the unit. If not,please
contact qualied professionals for service.
Please contact qualied professionals for service.
Please contact qualied professionals for service.
Please contact qualied professionals for service.
Note: If there're other error codes, please contact qualied professionals for
service.
21
Installation dimension diagram
Drainage pipe
At least 250cm
At least 15cm
At least 50cm
At least 50cm
At least
30cm
At least 300cm
At least 200cm
Space to the oor
Space to the obstruction
Space to the
obstruction
Space to the
obstruction
Space to the ceiling
Space to the obstruction
Space to the obstruction
At least 30cm
At least 15cm
At least 15cm
Space to the wall
Space to the wall
Space to the wall
22
1. There should be no obstruction near air inlet and air outlet.
2. Select a location where the condensat­ ion water can be dispersed easily and
won't affect other people.
3. Select a location which is convenient to connect the outdoor unit and near the power socket.
4. Select a location which is out of reach for children.
5.
The location should be able to withstand
the weight of indoor unit and won't incr-
ease noise and vibration.
6.
The appliance must be installed 2.5m
above oor.
7. Don't install the indoor unit right above
the electric appliance.
8. Please try your best to keep way from
uorescent lamp.
Tools for installation
Selection of installation location
1 Level meter 2 Screw driver 3 Impact drill 4 Drill head 5 Pipe expander 6 Torque wrench
7 Open-end wrench 8 Pipe cutter
9 Leakage detector
10 Vacuum pump 11 Pressure meter 12 Universal meter
13 Inner hexagon spanner 14 Measuring tape
Note:
● Please contact the local agent for installation.
● Don't use unqualied power cord.
Basic requirement
Outdoor unit
Indoor unit
Installing the unit in the following pla­ces maycause malfunction. If it is un­avoidable, please consult the local dealer:
1.The place with strong heat sources,
vapors, ammable or explosive gas
,
or volatile objects spread in the air.
2.The place with high-frequency devices (such as welding machine, medical equipment).
3.The place near coast area.
4.
The place with oil or fumes in the air.
5.The place with sulfureted gas.
6.Other places with special circums­ tances.
7.Do not use the unit in the immediate surroundings of a laundry a bath a shower or a swimming pool.
1. Select a location where the noise and outow air emitted by the outdoor unit
will not affect neighborhood.
2. The location should be well ventilated and dry, in which the outdoor unit
won't be exposed directly to sunlight or strong wind.
3. The location should be able to withstand the weight of outdoor unit.
4. Make sure that the installation follows the requirement of installation dimension diagram.
5. Select a location which is out of reach for children and far away from animals or plants.If it is unavoidable, please add the fence for safety purpose.
23
Requirements for electric connection
Safety precaution
Grounding requirement
1. Must follow the electric safety regulations when installing the unit.
circuit break.
3. Make sure the power supply matches with the requirement of air conditioner. Unstable power supply or incorrect wiring or malfunction. Please install proper power supply cables before using the air conditioner.
4. Properly connect the live wire, neutral wire and grounding wire of power socket.
5. Be sure to cut off the power supply before proceeding any work related to electricity and safety.
7. If the supply cord is damaged, it must be replaced by the manufacturer, its
8. The temperature of refrigerant circuit will be high, please keep the interconnec­ tion cable away from the copper tube.
9. The appliance shall be installed in accordance with national wiring regulations.
10.Installation must be performed in accordance with the requirement of NEC and CEC by authorized personnel only
grounding with specialized grounding device by a professional. Please make sure it is always grounded effectively, otherwise it may cause electric shock.
2. The yellow-green wire in air conditioner is grounding wire, which can't be used for other purposes.
3. The grounding resistance should comply with national electric safety regulations.
4. The appliance must be positioned so that the plug is accessible.
5. An all-pole disconnection switch having a contact separation of at least 3mm in
6. Including an circuit break with suitable capacity, please note the following table. Air switch should be included magnet buckle and heating buckle function, it can protect the circuit-short and overload. (Caution: please do not use the fuse only for protect the circuit)
Air-conditioner Circuit break capacity
09、12K 15A
24
Installation of indoor unit
Step one: choosing installation location
Step two: install wall-mounting frame
rm it with the client.
1. Hang the wall-mounting frame on the wall; adjust it in horizontal position with the
plastic expansion particles in the holes.
3. Fix the wall-mounting frame on the wall with tapping screws (ST4.2X25TA) and
.
1. Choose the position of piping hole according to the direction of outlet pipe. The position of piping hole should be a little lower than the wall-mounted frame, shown as below.
Step three: open piping hole
2. Open a piping hole with the diameter of Φ55 or Φ70 on the selected outlet pipe position. In order to drain smoothly, slant the piping hole on the wall slightly downward to the outdoor side with the gradient of 5-10°.
0912K:
Left
Wall
Φ55/Φ70
Right
Mark in the middle of it
Level meter
Rear piping hole
Wall
Space
to the
wall
above
150mm
Space
to the
wall
above
150mm
Φ55/Φ70
Rear piping hole
25
1. Aim the pipe joint at the corresponding bellmouth.
2. Pretightening the union nut with hand.
3. Adjust the torque force by referring to the following sheet. Place the open-end wrench on the pipe joint and place the torque wrench on the union nut. Tighten the union nut with torque wrench.
2. When select leading out the pipe from left or right, please cut off the corresponding hole on the bottom case.
cut off the hole
left right
1. The pipe can be led out in the direction of right, rear right, left or rear left.
left
rear left
right
rear right
Step four: outlet pipe
Installation of indoor unit
union nutpipe joint
pipe
Note:
● Pay attention to dust prevention and take relevant safety measures when
opening the hole.
The plastic expansion particles are not provided and should be bought
locally.
Indoor
5-10
outdoor
Φ55/ Φ70
26
4. Wrap the indoor pipe and joint of con­ nection pipe with insulating pipe, and then wrap it with tape.
Step six: install drain hose
Installation of indoor unit
torque wrench
open-end wrench
indoor pipe
pipe
union nut
Hex nut diameter Tightening torque (N.m)
Φ 6
Φ 9.52
Φ 12 Φ 16 Φ 19
30~40
45~55
60~65 70~75
15~20
insulating pipe
1. Connect the drain hose to the outlet pipe of indoor unit.
2. Bind the joint with tape.
outlet
pipe
drain hose
drain hose
tape
outlet pipe
drain hose
insulating pipe
Note:
● Add insulating pipe in the indoor
drain hose in order to prevent condensation.
● The plastic expansion particles are
not provided.
1. Open the panel, remove the screw on the wiring cover and then take down the cover.
wiring cover
screw
panel
Step seven: connect wire of indoor unit
27
4. Put wiring cover back and then tighten the screw.
5. Close the panel.
Installation of indoor unit
Note:
All wires of indoor unit and outdoor unit should be connected by a professional.
for a new one. Avoid extending the wire by yourself.
installation.
● For the air conditioner without plug, an circuit break must be installed in the line.
The circuit break should be all-pole parting and the contact parting distance
should be more than 3mm.
3. Remove the wire clip; connect the power connection wire to the wiring terminal
with wire clip.
power connection wire
cable-cross hole
2. Make the power connection wire go through the cable-cross hole at the back
of indoor unit and then pull it out from
the front side.
0912K:
2 3N(1)
Outdoor unit connection
2 3N(1)
28
Installation of indoor unit
Step eight: bind up pipe
1. Bind up the connection pipe, power cord and drain hose with the band.
indoor unit
gas pipe
indoor and
outdoor power cord
liquid pipe
drain hose
band
2. Reserve a certain length of drain hose and power cord for installation when binding them. When binding to a certain degree, separate the indoor power and then separate the drain hose.
3. Bind them evenly.
4. The liquid pipe and gas pipe should be bound separately at the end.
Note:
● The power cord and control wire
can't be crossed or winding.
● The drain hose should be bound
at the bottom.
drain hose
band
connection pipe
indoor power cord
Step nine: hang the indoor unit
1. Put the bound pipes in the wall pipe and then make them pass through the wall hole.
2. Hang the indoor unit on the wall-mounting frame.
3. Stuff the gap between pipes and wall hole with sealing gum.
4. Fix the wall pipe.
5. Check if the indoor unit is installed rmly and closed to the wall.
Note:
● Do not bend the drain hose too excessively in order to prevent blocking.
indoor
outdoor
wall pipe
sealing gum
upper hook
lower hook of wall-mounting frame
29
Installation of outdoor unit
Step one: x the support of outdoor unit
(select it according to the actual installation situation)
1. Select installation location according to the house structure.
2. Fix the support of outdoor unit on the selected location with expansion screws.
at least 3cm above the floor
Note:
● Take sufcient protective measures when
installing the outdoor unit.
Make sure the support can withstand at least
four times of the unit weight.
● The outdoor unit should be installed at least 3cm above the oor in order to install drain
joint.
● For the unit with cooling capacity of 2300W
~5000W, 6 expansion screws are needed; for the unit with cooling capacity of 6000W ~8000W, 8 expansion screws are needed; for the unit with cooling capacity of 10000W
~16000W, 10 expansion screws are needed.
Step two: install drain joint (Only for cooling and heating unit)
1. Connect the outdoor drain joint into the hole on the chassis, as shown in the picture below.
2. Connect the drain hose into the drain vent.
chassis
outdoor drain joint
Drain hose
drain vent
Step three: x outdoor unit
1. Place the outdoor unit on the support.
2. Fix the foot holes of outdoor unit with bolts.
foot holes
foot holes
30
Installation of outdoor unit
Step four: connect indoor and outdoor pipes
1. Remove the screw on the right han­ dle of outdoor unit and then remove the handle.
2. Remove the screw cap of valve and aim the pipe joint at the bellmouth of pipe.
3. Pretightening the union nut with hand.
4. Tighten the union nut with torque wrench by referring to the sheet below.
handle
screw
gas pipe
liquid pipe
liquid valve
gas valve
union nut
pipe joint
Hex nut diameter
Tightening torque
(N.m)
Φ 6
Φ 9.52
Φ 12 Φ 16 Φ 19
30~40
45~55
Indoor unit connection
09、12K:
2 3N(1)
L2L1
2 3N(1)
L1
L2
POWER
60~65 70~75
15~20
1. Remove the wire clip; connect the power connection wire and signal control wire (only for Heat pump type) to the wiring terminal according to the color; fix them with screws.
31
Step six: neaten the pipes
1. The pipes should be placed along the wall, bent reasonably and hidden possibly. Min. semidiameter of bending the pipe is 10cm.
2. If the outdoor unit is higher than the wall
hole, you must set a U-shaped curve in the
pipe before pipe goes into the room, in order to prevent rain from getting into the room.
● The through-wal height of drain hose shouldn't be higher than the outlet
pipe hole of indoor unit.
● Slant the drain hose slightly dow­ nwards. The drain hose can't be curved, raised and uctuant, etc.
● The water outlet can't be placed
in water in order to drain smoothly.
Installation of outdoor unit
U-shaped curve
wall
drain hose
the drain hose
can't raise upwards.
The drain hose can't be fluctuant
The drain hose can't be fluctuant
The water outlet can't be fluctuant
The water outlet can't be placed in water
Note:
2. Fix the power connection wire and signal control wire with wire clip (only for cooling and heating unit).
Note:
● After tighten the screw, pull the power cord slightly to check if it is rm.
● Never cut the power connection wire to prolong or shorten the distance.
32
Vacuum pumping
Leakage detection
1. Remove the valve caps on the liquid valve and gas valve and the nut of refri­ gerant charging vent.
2. Connect the charging hose
of piezometer to the refri-
gerant charging vent of gas valve and then connect the other charging hose to the vacuum pump.
3. Open the piezometer com-
pletely and operate for 10-15min to check if the
pressure of piezometer re-
mains in -0.1MPa.
4. Close the vacuum pump and maintain this status for 1-2min to check if the pres-
sure of piezometer remains
in -0.1MPa. If the pressure decreases, there may be leakage.
5. Remove the piezometer, open the valve core of liquid valve and gas valve
completely with inner hexagon spanner.
6. Tighten the screw caps of valves and refrigerant charging vent.
7. Reinstall the handle.
Use vacuum pump
liquid valve
gas valve
refrigerant charging vent
nut of refrigerant charging vent
vacuum pump
piezometer
valve cap
Lo Hi
inner hexagon spanner
open
close
1. With leakage detector: Check if there is leakage with leakage detector.
2. With soap water: If leakage detector is not available, please use soap water for leakage detection.
Apply soap water at the suspected position and keep the soap water for more than 3min. If there are air bubbles coming out of this position, there's a leakage.
33
Check after installation
Test operation
● Check according to the following requirement after nishing installation.
Items to be checked Possible malfunction
Has the unit been installed rmly? The unit may drop, shake or emit noise. Have you done the refrigerant leakage
test?
It may cause insufcient cooling
(heating) capacity.
Is heat insulation of pipeline sufcient?
It may cause condensation and water dripping.
Is water drained well?
It may cause condensation and water dripping.
Is the voltage of power supply accord­ing to the voltage marked on the nameplate?
It may cause malfunction or damaging the parts.
Is electric wiring and pipeline installed correctly?
It may cause malfunction or damaging
the parts. Is the unit grounded securely? It may cause electric leakage. Does the power cord follow the speci-
cation?
It may cause malfunction or damaging
the parts. Is there any obstruction in the air inlet
and outlet?
It may cause insufcient cooling
(heating) capacity. The dust and sundries caused during
installation are removed?
It may cause malfunction or damaging
the parts. The gas valve and liquid valve of
connection pipe are open completely?
It may cause insufcient cooling
(heating) capacity.
1. Preparation of test operation
● The client approves the air conditioner.
● Specify the important notes for air conditioner to the client.
2. Method of test operation
● Put through the power, press ON/OFF button on the remote controller to start
operation.
● Press MODE button to select AUTO, COOL, DRY, FAN and HEAT to check
whether the operation is normal or not.
● If the ambient temperature is lower than 16℃, the air conditioner can’t
start cooling.
34
Conguration of connection pipe
1. Standard length of connection pipe
● 5m, 7.5m, 8m.
4. The additional refrigerant oil and refrigerant charging required after prolonging connection pipe
● After the length of connection pipe is prolonged for 10m at the basis of
standard length, you should add 5ml of refrigerant oil for each additional 5m of connection pipe.
● The calculation method of additional refrigerant charging amount (on the basis
of liquid pipe):
Additional refrigerant charging amount = prolonged length of liquid pipe ×
additional refrigerant charging amount per meter
● When the length of connection pipe is above 5m, add refrigerant according to
the prolonged length of liquid pipe. The additional refrigerant charging amount per meter is different according to the diameter of liquid pipe. See the following sheet.
Cooling capacity
Cooling capacity
5000Btu/h
(1465W)
24000Btu/h
(7032W)
7000Btu/h
(2051W)
28000Btu/h
(8204W)
9000Btu/h
(2637W)
36000Btu/h
(10548W)
12000Btu/h
(3516W)
42000Btu/h
(12306W)
18000Btu/h
(5274W)
48000Btu/h
(14064W)
Max height difference
Max height difference
Max length of connec­tion pipe
Max length of connec­tion pipe
15 255 10
15 305 10
15 305 20
20 3010 20
25 3010 20
2.Min. length of connection pipe is 3m.
3.Max. length of connection pipe and max. high difference.
35
Additional refrigerant charging amount for R22, R407C, R410A and R134a
Diameter of connection pipe
Liquid pipe(mm) Gas pipe(mm)
Φ6
Φ6 or Φ9.52
Φ12
Φ16
Φ19
Φ22.2
Φ9.52 or Φ12
Φ16 or Φ19
Φ19 or Φ22.2
Φ25.4 or Φ31.8
_
_
Cooling only(g/m) Cooling and heating(g/m)
15
15
30
60
250 250
350
350
120
120
50
20
Outdoor unit throttle
Conguration of connection pipe
36
Pipe expanding method
Note:
Improper pipe expanding is the main cause of refrigerant leakage. Please expand the pipe according to the following steps:
A: Cut the pipe
● Conrm the pipe length according to
the distance of indoor unit and outdoor unit.
● Cut the required pipe with pipe cutter.
pipe
pipe cutter
leaning uneven burr
B: Remove the burrs
● Remove the burrs with shaper and
prevent the burrs from getting into the pipe.
downwards
pipe
shaper
C: Put on suitable insulating pipe D: Put on the union nut
● Remove the union nut on the indoor
connection pipe and outdoor valve; install the union nut on the pipe.
union pipe
pipe
E: Expand the port
● Expand the port with expander.
Note:
● "A" is different according to the
diameter, please refer to the sheet below:
expander
hard mold
pipe
F: Inspection
● Check the quality of expanding port.
If there is any blemish, expand the port again according to the steps above.
the length is equal
improper expanding
leaning
damaged
surface
crack uneven
thickness
smooth surface
Outer diameter
(mm)
A(mm)
Max Min
Φ6-6.35(1/4")
Φ9.52(3/8")
Φ12-12.7(1/2")
Φ15.8-16(5/8")
1.3 0.7
1.6 1.0
1.8 1.0
2.4 2.2
66129916452