INSTALLATION AND
OPERATING
INSTRUCTIONS
VENTILATION FAN / LIGHT
READ AND SAVE THESE
INSTRUCTIONS
GENERAL SAFETY INFORMATION
1. Make sure that the electric service supply voltage is
AC 120V, 60Hz.
2. Follow all local electrical and safety codes, as well as
the Nation Electrical Code (NEC) and the Occupation
Safety and Healthy Act (OSH Act).
3. Always disconnect the power source before working
on or near the ventilating fan, motor or junction box.
4. Protect the power cord from sharp edges, oil, grease,
hot surfaces, chemicals or other objects.
5. Do not kink the power cord.
. Do not install the unit where ducts are congured as
6
shown in Fig. A.
7. Provide suction parts with proper ventilation.
8. This unit is UL listed for use over a bathtub or shower
when installed in a GFCI protected branch circuit.
9. These ventilating fans are intended for residential
usage only.
WARNING
TO REDUCE THE RISK OF FIRE, ELECTRIC SHOCK, OR
INJURY TO PERSONS, OBSERVE THE FOLLOWING:
1. Use this unit only in the manner intended by the
manufacturer. If you have questions, co
manufacturer.
2. Before servicing or cleaning unit, switch power o at
service panel and lock the service disconnecting
means to prevent power from being switched on
accidentally. When the service disconnecting means
cannot be locked, securely fasten a prominent
warning device, such as a tag, to the service panel.
3. Installation work and electrical wiring must be done
by qualied person(s) in accordance with all
applicable codes and standards, including re
construction.
4. Sufcient air is needed for proper combustion and
exhausting of gases through the ue (chimney) of
fuel burning equipment to prevent back drafting.
Follow the heating equipment manufacturer’s
guideline and safety standards such as those
published by the National Fire Protection Association
(NFPA), and the American Society for Heating,
Refrigeration and Air Conditioning Engineers
(ASHRAE) and the local code authorities.
5. When cutting or drilling into wall or ceiling, do not
damage electrical wiring and ot
6. Ducted fans must always be vented to the outdoors.
7. If this unit is to be installed over a tub or shower, it
must be marked as appropriate for the application
and be connected to a GFCI (Ground Fault Circuit
Interrupter) -protected branch circuit.
8. Do not use this unit with any other solid-state
control devices. Solid-state control devices may
cause harmonic distortion, which can cause a motor
humming noise.
ntact the
-rated
her hidden utilities.
9. NEVER place a switch where it can be reached from
a tub or shower.
10. Not to be installed in a ceiling thermally insulated to
a value greater than R40. (This is required for
installation in Canada only).
Turning angle too large Duct shrink
Too many elbows Elbow near the body
Body
Fig. A
CAUTION
1. For general ventilating use only. Do not use to
exhaust hazardous or explosive materials and vapors.
2. Not for use in cooking areas. (Fig. B)
3. This product must properly connect to the
grounding conductor of the supply circuit.
4. To reduce the risk of injury to persons, install the fan
at least 7 feet (2.1m) above the
Cooking area
Do not install above or
inside this area
45°
Cooking
Equipment
Fig. B
SUPPLIED ACCESSORIES
Part name Appearance Quantity
Grille
Fan
Housing
Duct
Connector
(4”)
oor.
45°
floor
1
1
1
1
GBR50L / GBR80
GU24 base
bulb lamp
(26W)
Grille bracket
Screw
(ψ4×25)
Screw
(M4x6)
Screw
(#8-32x1-1/
)
1. INSTALLATIONS
MOUNT HOUSING WITH FLANGE:
1-1. To bend the housing tabs out to 90 degree and
make housing tabs contact the bottom of the joist.
Tabs
1-2. The housing mounts with 4 screws (ψ4×25). Screw
housing to joist through lowest holes in each
mounting ange, then through the other holes.
Screw
USING SUSPENSION BRACKETS (SOLD SEPARATELY)
1-3. Sliding suspension brackets available to allow for
your specic positioning of housing anywhere
between joists and span up to 24”.
1-4. Insert suspension brackets into the channels on
housing. Make sure tabs face “up” shown.
Suspension Bracket
(Sold
separately)
Channel
1-5. Extend suspension brackets to the width of the joists.
Hold fan in place with the suspension brackets tabs
wrapping around the bottom of joist.
1
1
4
1
1
Joist
Joist
Tab Face
1-6. Fasten suspension brackets to joists with nails or
screws through holes near nails.
1-7. Secure suspension brackets together with screws.
Lock Screw
#8-32 x 1-
MODELS: GBR50L / GBR80L
Page 2.
1
"
4
11"
4" DUCT
1
"
2
2
3
5
"
4
Screw
Joist
Joist
Bottom of Joist
2. DUCT CONNECTION
2-1. Insert the duct into the duct connector and tape all
ductworks connection to make them secure and air
tight.
2-2. Install the duct with a gradient 1°~2° to the outside.
Outside
Inside
Duct
Connector
Ceiling
Body
Grille
Tape
Duct
Gradient
1°~2°
3. CONNECT WIRING
3-1. Follow all local electrical and safety codes.
3-2. NEVER place a switch where it can be reached from a
tub or shower.
3-3. Connect wires as shown in wiring diagrams.
LIGHT
SWITCH
FAN
SWITCH
BLK
LINE
WHT
IN
GRD
HOUSE ELECTRICAL BOX
BLU
BLK
LIGHT/FAN ELECTRICAL BOX
LIGHT
(BLUE)
FAN
(BLK)
WHT
WHT
3-4. Using wire nuts (not provided), connect house
power cable to ventilating fan.
3-5. 14 AWG (2.1 mm
2
) is the smallest conductor that
shall be used for branch-circuit wiring.
4. TEST RUN & GRILLE ATTACHMENT
4-1. When the power on, check for abnormal vibration or
sound.
4-2. Insert the grille bracket into the main body, and lock
screw (M4×6) to x on the main body.
4-4. Install light bulbs and attach the cover.
GU24 Lamp (26W Max.)
Lock lens cover
5. OPERATION
5-1. Turn on the power switch to operate ON or OFF, and
LED indicator is green. Turn on the power to operate
main light on/o.
6. MAINTENANCE
WARNING:
Disconnect power source before working on unit. Routine
maintenance must be done every year.
CAUTION:
1. Never use gasoline, benzene, thinner or any other
such chemicals for cleaning the ventilating fan.
2. Do not allow water to enter motor.
3. Do not soak resin parts in water over 60°C.
CLEANING:
1. Open lens cover. Remove the light
bulbs carefully.
Disassemble the screw (#8-32×1-1/4”), and light
power connections to remove grille.
2. Wash and clean grille. CAUTION: Do not let water
into the lamp base. (Use non-abrasive kitchen
detergent, wipe dry with a new cloth.)
3. Using a cloth dampened with non-abrasive kitchen
detergent, remove dust and dirt from ventilating fan.
Wipe dry with new cloth.
4. Replace grille.
DIMENSIONS
88""
11
""
44
88
33
55
44
1111 ""
""
1111 ""
11"
SPECIFICATIONS
Voltage
Model No.
GBR50L 120 60 33.1 50 6.4 Light
GBR80L 120 60 40.1 80 6.4 Light
Note: Design and specications subject to change without notice.
(V )
Frequency
(Hz)
WARRANTY
DELTA ELECTRONICS THREE YEAR LIMITED WARRANTY
Delta Electronics Inc. (”Delta Electronics”) warrants to the
original consumer purchaser in the USA that the Breez
ventilation fan products will be free from defects in
material or workmanship. This warranty is limited to three
(3) years from the original date of purchase.
Limitations and Exclusions
1. During the warranty period, a replacement for any
defective product will be supplied free of charge for
installation by the consumer. The warranty provided
herein does not cover charges for labor or other costs
incurred in the troubleshooting, repair, removal, and
installation service.
2. All returns of defective parts or products must include
the product model number, and must be made through
an authorized Delta Electronics distributor. Authorized
returns must be shipped prepaid. Repaired or
replacement products will be shipped by Delta
Electronics F.O.B. shipping point.
3. Delta Electronics shall not be liable for any indirect,
incidental, consequential, punitive, or special damages
arising out of or in connection with products use or
performance, regardless of the form of action whether in
contract, tort (including negligence), strict product
liability or otherwise.
4. This warranty does not extend to uorescent lamp
starters and tubes.
5. The warranty does not cover if user does not comply
with manufacturer’s installation manual.
6. To qualify for warranty service, you must notify Delta
Electronics at the address or telephone number below.
7. Delta Electronics shall have no liability to the original
owner-user with respect to any defect caused by abuse,
misuse, neglect, improper transportation or storage,
improper testing, improper installation, improper
operation, improper use, improper maintenance,
improper repair, improper alteration, improper
modication, tampering or accident of products or parts
thereof, or unusual deterioration or degradation of
products or parts thereof due to a physical environment
beyond the requirements of product’s specications.
Address: 4405 Cushing Parkway, Fremont, CA 94538 US
Toll Free Number: 1-888-979-9889
Power
( W)
Air Flow
@ 0.1SP
(CFM)
1
8
"
4
Weight
Note
(lb.)
Screw M4 x 6
4-3. Mount the grille to the grille bracket by screw
(#8-32×1-1/4”).