Delta GBR80H User Manual

Model
Quantity
Comments
Project:
Location:
Architect:
Engineer:
Contractor:
Submitted by:
Date:
MODEL GBR80H
(80 CFM)
Full Speed:
80 CFM/0.8 Sones @ 0.1 SP, 9.7 Watts 68 CFM/1.2 Sones @ 0.25 SP, 11.8 Watts
Low Speed:
50 CFM/<0.3 Sones @ 0.1 SP, 4.0 Watts 37 CFM/1.0 Sones @ 0.25 SP, 6.0 Watts
Description
Low noise ceiling mount ventilating fan, rated for continuous running. Fan has been awarded ENERGY STAR® Most Ecient in
2014. It is HVI, UL, and cUL certied, and can be used to comply with ASHRAE 62.2 (local and whole building continuous and intermittent operation), CA Title 24, and CALGreen requirements.
Motor/Blower
Power rating of 120 volts/60Hz
DC brushless motor engineered to run continuously
Motor equipped with thermal cuto fuse.
Removable with permanently lubricated plug-in motor
Housing
• Galvanized steel body
• Detachable 4” diameter duct adapter
• Built-in backdraft damper
• Easy installation with expandable extension bracket
Grille
• Attractive design using ABS material
• Attaches directly to housing with torsion springs
LED Indicator
• Blue and amber LED indicator lights to show humidity sensor and full speed modes
Warranty
• 3-year limited warranty
Features
• Adjustable humidity set points between ~50% to ~80% RH
• Adjustable low speed airow
• For ceiling mount only, airow of 80 CFM(±10%) and 0.8 Sones at 0.1” static pressure
• Power consumption approximately 9.7 Watts with an eciency rating approximately 8.2 CFM/Watt at 0.1” static pressure
• UL and cUL listed for tub/shower enclosure when used with GFCI-protected branch circuit wiring
GreenBuilder GBR80H
Static Pressure (inches w.g.) 0.1 0.25 0.1 0.25 Air Flow (CFM) 50 37 80 68
Power Consumption (Watts) 4.0 6.0 9.7 11.8 Energy Eciency (CFM/Watt) 12.5 6.1 8.2 5.7 Current (Amps) 0.16 Max 0.22 Max
Continuous low speed
Full speed
06 / 021 )zH/V( gnitaR rewoP
DC Motor Technology
Allows fan to operate in full speed mode or humidity control mode by manual switch.
For humidity control mode, when humidity is above the user-adjustable set-point, fan runs at full speed (80 CFM). When humidity is below the set-point, the fan runs continuously at a pre-set lower level (0 or 50 CFM).
Built-in soft start function to increase bearings life
Automatically powers OFF when impeller is locked
8.25”
4.0”
10.75"
8.0”
10.75"
Control Options
%RH
80
70
50
60
2.18.00.1 3.0< senoS
CFM
50
0
0.90
0.80
0.70
0.60
O)
2
0.50
0.40
0.30
0.25
0.20
Air Pressure (IN H
0.10
0
0 30.0 60.0 90.0 120.0 150.0
Fan Curve
Air Flow ( CFM)
Full Speed
80CFM
Low Speed
50CFM
50ft
40ft
30ft
20ft
10ft
5.75”
4405 Cushing Parkway | Fremont, CA 94538 | tel 1.888.979.9889 | www.deltabreez.com
Loading...