INSTALLATION AND OPERATING INSTRUCTIONS
VENTILATION FAN / LIGHT
READ AND SAVE THESE INSTRUCTIONS
GENERAL SAFETY INFORMATION
1. Make sure that the electric service supply voltage is
AC 120V, 60Hz.
2. Follow all local electrical and safety codes, as well as
the Nation Electrical Code (NEC) and the Occupation Safety and Healthy Act (OSH Act).
3. Always disconnect the power source before working
on or near the ventilating fan, motor or junction box.
4. Protect the power cord from sharp edges, oil, grease,
hot surfaces, chemicals or other objects.
5. Do not kink the power cord
not install the unit where ducts are congured as
6. Do
shown in Fig. A.
7. Provide suction parts with proper ventilation.
8. This unit is UL listed for use over a bathtub or shower
when installed in a GFCI protected branch circuit.
9. These ventilating fans are intended for residential
usage only.
WARNING
TO REDUCE THE RISK OF FIRE, ELECTRIC SHOCK, OR INJURY TO PERSONS, OBSERVE THE FOLLOWING:
1. Use this unit only in the manner intended by the
manufacturer. If you have questions manufacturer.
2. Before servicing or cleaning unit, switch power o at
service panel and lock the service disconnecting means to prevent power from being switched on accidentally. When the service disconnecting means cannot be locked, securely fasten a prominent warning device, such as a tag, to the service panel.
3. Installation work and electrical wiring must be done
by qualied person(s) in accordance with all applicable codes and standards, including construction.
4. Sufcient air is needed for proper combustion and
exhausting of gases through the ue (chimney) of fuel burning equipment to prevent back drafting. Follow the heating equipment manufaturer’s guideline and safety standards such as those published by the National Fire Protection Association (NFPA), and the American Society for Heating, Refrigeration and Air Conditioning Engineers (ASHRAE) and the local code authorities.
5. When cutting or drilling into wall or ceiling, do not
damage electrical wiring and
6. Ducted fans must always be vented to the outdoors.
7. If this unit is to be installed over a tub or shower, it
must be marked as appropriate for the application and be connected to a GFCI (Ground Fault Circuit Interrupter) -protected branch circuit.
8. Do not use this unit with any other solid-state
control devices. Solid-state control devices may cause harmonic distortion, which can cause a motor humming noise.
.
, c
ontact the
o
ther hidden utilities.
re-r
ated
9. NEVER place a switch where it can be reached from
a tub or sho
10. Not to be installed in a ceiling thermally insulated to
a value greater than R40. (This is required for installation in Canada only).
Turning angle too large Duct shrink
Too many elbows Elbow near the body
we
r.
Body
Fig. A
CAUTION
1. For general ventilating use only. Do not use to
exhaust hazardous or explosive materials and vapors.
2. Not for use in cooking areas. (Fig. B)
3. This product must properly connect to the
grounding conductor of the supply circuit.
4. To reduce the risk of injury to persons, install the fan
at least 7 feet (2.1m)
SUPPLIED ACCESSORIES
Part name Appearance Quantity
Grille
Fan
Housing
Duct
Connector
“)
(4
abov
Cooking area
Do not install above or
inside this area
45°
Cooking Equipment
Fig. B
e the oor.
45°
floor
1
1
1
1
GBR100L
GU24 base
bulb lamp
(26W)
Grille bracket
Screw
(ψ4×25)
Screw
(M4x6)
Screw
(#8-32x1-1/4 ”)
1. INSTALLATIONS
MOUNT HOUSING WITH FLANGE:
1-1. To bend the housing tabs out to 90 degree and
make housing tabs contact the bottom of the joist.
1-2. The housing mounts with 4 screws (ψ4×25). Screw
housing to joist through lowest holes in each mounting ange, then through the other holes.
USING SUSPENSION BRACKETS (SOLD SEPARATELY)
1-3. Sliding suspension brackets available to allow for
your specic positioning of housing anywhere between joists and span up to 24”.
1-4. Insert suspension brackets into the channels on
housing. Make sure tabs face “up” shown.
Suspension Bracket (Sold separately)
1-5. Extend suspension brackets to the width of the joists.
Hold fan in place with the suspension brackets tabs wrapping around the bottom of joist.
Tabs
Channel
1
1
4
1
1
Joist
Joist
Screw
Tab Face
MODELS:
Page 2.
Air Flow
(CFM)
DELTA ELECTRONICS THREE YEAR LIMITED WARRANTY
Free Number: 1-888-979-9889
GlobalTowne ~ 888-726-9752
www.globaltowne.com
1-6. Fasten suspension brackets to joists with nails or
screws through holes near nails.
1-7. Secure suspension brackets together with screws.
Screw
Joist
Joist
Bottom of Joist
(#8-32×1-1/4”).
Screw
#8-32 x 1-
4-3. Install light bulbs and attach the cover.
GU24 Lamp (26W Max.)
GBR100L
DIMENSIONS
1
"
4
"
8
5
"
2
.
8
5.7 5 "
11"
1
4" DUCT
1
"
1
1
2.5"
"
5.75"
2. DUCT CONNECTION
2-1. Insert the duct into the duct connector and tape all
ductworks connection to make them secure and air tight.
2-2. Install the duct with a gradient 1°~2° to the outside.
Duct Connector
Body
Ceiling
Grille
Tape
Inside
Duct
3. CONNECT WIRING
3-1. Follow all local electrical and safety codes,
ANSI/NFPA70.
3-2. NEVER place a switch where it can be reached from a
tub or shower.
3-3. Connect wires as shown in wiring diagrams.
LIGHT SWITCH
FAN SWITCH
BLK
LINE
WHT
IN
GRD
HOUSE ELECTRICAL BOX
BLU
LIGHT
(BLUE)
FAN
BLK
(BLK)
LIGHT/FAN ELECTRICAL BOX
3-4. Using wire nuts (not provided), connect house
power cable to ventilating fan.
3-5. 14 AWG (2.1 mm
2
) is the smallest conductor that
shall be used for branch-circuit wiring.
4. TEST RUN & GRILLE ATTACHMENT
4-1. When the power on, check for abnormal vibration or
sound.
4-2. Insert the grille bracket into the main body, and lock
screw (M4×6) to x on the main body.
Screw M4 x 6
Mount the grille to the grille bracket by screw
Outside
Gradient
1°~2°
WHT
WHT
Lock lens cover
5. OPERATION
5-1. Turn on the power switch to operate ON or OFF, and
LED indicator is green. Turn on the power to operate main light on/o.
6. MAINTENANCE
WARNING:
Disconnect power source before working on unit. Routine maintenance must be done every year.
CAUTION:
1. Never use gasoline, benzene, thinner or any other
such chemicals for cleaning the ventilating fan.
2. Do not allow water to enter motor.
3. Do not soak resin parts in water over 60°C.
CLEANING
1. Open lens cover. Remove
the l Disassemble the screw (#8-32×1-1/4”), and light power connections to remove grille.
2. Wash and clean grille. CAUTION: Do not let water
into the lamp base. (Use non-abrasive kitchen detergent, wipe dry with a new cloth.)
3. Using a cloth dampened with non-abrasive kitchen
detergent, remove dust and dirt from ventilating fan. Wipe dry with new cloth.
4. Replace grille.
ight bulbs carefully.
11"
8.25"
SPECIFICATIONS
Voltage
Model No.
GBR100L 120 60 40.0 100 6.4 Light
Note: Design and specications subject to change without notice.
(V )
Frequency
(Hz)
Power
( W)
@ 0.1SP
Weight
(lb.)
Note
WARRANTY
Delta Electronics Inc. (”Delta Electronics”) warrants to original consumer purchaser in the USA that the Breez ventilation fan products will be free from defects in
material or workmanship. This warranty is limited to three (3) years from the original date of purchase.
Limitations and Exclusions
1. During the warranty period, a replacement for any defective product will be supplied free of charge for installation by the consumer. The warranty provided herein does not cover charges for labor or other costs incurred in the troubleshooting, repair, removal, and installation service.
2. All returns of defective parts or products must include the product model number, and must be made through an authorized Delta Electronics distributor. Authorized returns must be shipped prepaid. Repaired or replacement products will be shipped by Delta Electronics F.O.B. shipping point.
3. Delta Electronics shall not be liable for any indirect, incidental, consequential, punitive, or special damages arising out of or in connection with products use or performance, regardless of the form of action whether in contract, tort (including negligence), strict product liability or otherwise.
4. This warranty does not extend to uorescent lamp starters and tubes.
5. The warranty does not cover if user does not comply
with manufacturer’s installation manual
6. To qualify for warranty service, you must notify Delta Electronics at the address or telephone number below.
7. Delta Electronics shall have no liability to the original owner-user with respect to any defect caused by abuse, misuse, neglect, improper transportation or storage, improper testing, improper installation, improper operation, improper use, improper maintenance, improper repair, improper alteration, improper modication, tampering or accident of products or parts thereof, or unusual deterioration or degradation of products or parts thereof due to a physical environment beyond the requirements of products’ specications .
Address: 4405 Cushing Parkway, Fremont, CA 94538 US Toll