Air Pressure
Air Flow
(mm H
2
O)
(IN H
2
O)
(M3/MIN)
(CFM)
UNIT :
(INCH)
mm
L
M
H
HH
0.48
0.40
0.32
0.24
0.16
0.08
0
2.41.81.20.60
BFB0305/12XA-A
0 .015 .030 .060.045 .075
12.0
10.0
8.0
4.0
2.0
0
6.0
24.0±0.3
24.0±0.3
7.6
30.0±0.5
30.0±0.5
10.0±0.5
(1.181±0.020)
(0.945±0.012)
(0.394±0.020)
(0.299)
(0.945±0.012)
(1.181±0.020)
21.0
(0.827)
6.0
(0.236)
2-Ø2.4±0.3
(2-Ø0.094±0.012)
5.0
(0.197)
150.0±10.0
(5.906±0.394)
http://www.deltaww.com
BFB
■
DIMENSIONS DRAWING
■
P & Q CURVE
(AT RATED VOLTAGE)
30 x 30 x 10 MM SERIES
*
Bearing Type
Ball Bearings
*
Material
Impeller & Frame : Plastic(UL 94V-0)
*
Lead Wires :
UL 1571 AWG #28 OR Equivalent
Red Wire Positive(+)
Black Wire Negative(-)
*
Weight : 10g (0.35 OZ)
MODEL
Rated
Voltage
Operating
Voltage
Range
Input
Current
Input
Power
Speed
Maximum
Air Flow
Maximum
Air Pressure
Noise
PART NO.
REV.
FUNCTION VDC VDC Amp Watt R.P.M. m3 /min CFM mmH2O IN H2O dB-A
BFB0305LA -A -R00 / -F00 5 4.0 to 5.5 0.06 0.30
5500 0.030 1.06 3.66 0.144 24.0
BFB0312LA -A -R00 / -F00 12 7.0 to 13.2 0.04 0.48
BFB0305MA -A -R00 / -F00 5 4.0 to 5.5 0.08 0.40
6500 0.035 1.24 5.23 0.206 26.0
BFB0312MA -A -R00 / -F00 12 7.0 to 13.2 0.05 0.60
BFB0305HA -A -R00 / -F00 5 4.0 to 5.5 0.11 0.55
7500 0.041 1.45 7.24 0.285 29.0
BFB0312HA -A -R00 / -F00 12 7.0 to 13.2 0.06 0.72
BFB0305HHA -A -R00 / -F00 5 4.0 to 5.5 0.15 0.75
8500 0.047 1.66 9.40 0.370 31.0
BFB0312HHA -A -R00 / -F00 12 7.0 to 13.2 0.08 0.96
* Function type is optional.
* The max. air ow and the speed are measured in free air ; max. air pressure is measured at zero air ow.
* Noise is measured in anechoic chamber in free air, one meter from intake side.
* All readings are typical values at rated voltage.
* Specications are subject to change without notice.