Delta Agema AG5648 Installation Manual

Page 1
Delta Networking – Agema Family
AG5648 Leaf/ToR Switch
Installation Guide
Page 2
ii
AG5648 Leaf/ToR Switch
Copyright
different from the photos.
All trademarks and logos mentioned in this guide are the properties of their respective holders.
Copyright © 2017 Agema Systems Inc. All rights reserved.
Regulatory and Safety Information
This product has been tested in accordance to, and complies with the following safety standards and
electromagnetic compatibility (EMC) inspection standards.
Emissions
Applicable standard
AS/NZS CISPR 22: Class A
ICES-003, Issue Class A
EN 55022: Class A
VCCI Class A
FCC CFR 47 Part 15, Subpart B Class A
Safety
Applicable standard
EN 60950-1, Second Edition
UL/CSA 60950-1, Second Edition
IEC 60950-1, Second Edition Including All National
Immunity
Applicable standard
EN 300 386, EMC for Network Equipment
EN 55024:
EN 61000-3-2: Harmonic Current Emissions
EN 61000-3-3: Voltage Fluctuations and Flicker
EN 61000-4-2: ESD
EN 61000-4-3: Radiated Immunity
EN 61000-4-4: EFT
EN 61000-4-5: Surge
EN 61000-4-6: Low Frequency Conducted Immunity
EN61000-4-8: Power Frequency magnetic eld
EN61000-4-11: Voltage dips and interruptions
RoHS
Applicable standard All AG-Series components are EU RoHS compliant
Warning: Fiber Optic Port Safety
When using a ber optic port, never look at the transmit laser while it is powered
on. Also, never look directly at the ber TX port and ber cable ends when they are
powered on.
Page 3
iii
Table of Contents
Table of Contents
Chapter 1: Introduction -------------------------------------------------------------------1
1.1 Overview ------------------------------------------------------------------------------------ 1
1.2 Package Content -------------------------------------------------------------------------- 1
1.3 Features ------------------------------------------------------------------------------------- 2
Chapter 2: Appearance and Mechanism --------------------------------------------3
2.1 Product Overview ------------------------------------------------------------------------- 3
2.2 LED Identication ------------------------------------------------------------------------- 4
2.3 System Requirements ------------------------------------------------------------------- 6
2.4 Data Center Deployment ---------------------------------------------------------------- 7
2.5 Power Supply Modules ------------------------------------------------------------------ 7
2.6 Fan Tray Module -------------------------------------------------------------------------- 8
Chapter 3: Installation ---------------------------------------------------------------------9
3.1 Mounting ------------------------------------------------------------------------------------ 9
3.2 Installing an Optional Transceiver and Cable -------------------------------------11
3.3 Connecting to the Console Port ------------------------------------------------------12
3.4 Connecting to a Power Source -------------------------------------------------------13
Chapter 4: Making the Network Connections ----------------------------------- 15
4.1 Twisted-pair Connections --------------------------------------------------------------15
4.2 Fiber Optic Connections ---------------------------------------------------------------16
4.3 Ethernet Cabling -------------------------------------------------------------------------17
Appendix 1 : Technical Specifications --------------------------------------------- 18
Appendix 2 : Warranty ------------------------------------------------------------------- 19
Limited and Support Warranty -------------------------------------------------------------19
Technical Support -----------------------------------------------------------------------------19
Page 4
1
AG5648 Leaf/ToR Switch
Chapter 1: Introduction
1.1 Overview
The AG5648 is next generation leaf/ToR switch for Data Center Networks, as well as
Enterprise network deployments. It leverage the 100G technology (4x25G Serdes) to provide
48-port 25G SFP28 and 6-port 100G QSFP28 in a compact 1RU form factor with 2.5 times
speed upgrade from current 10Gigabits leaf/ToR switch. The 48 ports 25G are backward
compatible to 10G and the 100G uplink offer dual speed – 40G and 100G.
The AG5648 is also SDN capable and supports ONIE installer and OpenFlow for today’s
open network ecosystem. It also provides comprehensive capability on layer 2 and layer
3 features, including SNMP, Spanning Tree, VLAN, QinQ, Trunk, QoS, RIP, OSPF, IGMP,
DVMRP, PIM-DM, PIM-SM, Access Control, etc. This product which aims for Data Center
Networks also supports advance features such as MPLS, TRILL, PFC, VEPA, QCN, VxLAN
and NVGRE to meet the high-demanding Data Center high performance and virtualization
requirement. The AG5648 is excellent choice for next generation hyper scale and medium
size datacenters and Core/Aggregation switches in Enterprise network environment.
1.2 Package Content
After unpacking this switch, check the contents to be sure you have received all the
components. Then, before beginning the installation, be sure you have all other necessary
installation equipment.
AG5648 switch
1 x AC power supply for AC version or 1 x DC power supply for DC version
Rack-mounting kits
2 x Velcro strips
Installation guide
If any item is missing or damaged, contact the vendor immediately, see Technical Support”.
Page 5
2
• IntroductionChapter 1
1.3 Features
The following lists the key main features of the AG5648 switch:
48 x 25GbE SFP28 ports
6 x 100GbE QSFP28 ports
1 x OOB Management
1 x Console port (RJ-45 type)
1 x USB port
Hot plugging redundant power supply support
4 Fan modules
System / Fan / Power status LED indication
On board high performance CPU system with large memory
Internal power supply; Max power 550W (AC version) or 550W (DC version)
Standard 1U chassis high
1.8 Tbps full-duplex switching
Automatic address learning function to build the packet-forwarding information table. The
table contains up to 288K MAC addresses
Low pin-to-pin latency: Cut-Through & Store and Forward Mode
16MB of packet buffer memory
Support Jumbo Frame up to 12Kbyte
Page 6
3
AG5648 Leaf/ToR Switch
Chapter 2: Appearance and Mechanism
2.1 Product Overview
2.1.1 Front View
Management port x 1
RJ-45 Console port x 1
SFP28 port x 48
QSFP28 port x 6
(Figure 2-1: Front View)
2.1.2 Rear View
PSU x 1
4 Fan tray slots
Secondary PSU
slot x 1 (optional)
USB port x 1
Reset x 1
(Figure 2-2: Rear View)
NOTE:
The switch supports up to two PSUs. However, it is shipped with one power supply pre-installed in the rear panel of the switch. You may purchase an additional PSU for redundancy.
Page 7
4
• Appearance and MechanismChapter 2
2.2 LED Identification
This section provides an overview of the front and rear LEDs.
2.2.1 Front LEDs
System LED
Upper SFP28
Port LED
Power LED
Fan Status LED
Lower SFP28
Port LED
Upper QSFP28 Port LED
Lower QSFP28 Port LED
(Figure 2-3: Front LED Identification)
LED Description
System LED
• Off – No Power
• Blinking Green – Booting, or System in Diagnostic mode
• Solid Green – Normal operation
• Solid Yellow – Critical Alarm
• Blinking Yellow – Non-critical alarm
Power LED
• Solid Green – Booting
• Off – Power is disconnected
When NOS is running:
• Solid Green – 2 Power Supplies are supplied to the switch and operating normally
• Solid Yellow – Single power supply is installed and operating
• Blinking Yellow – 2 Power Supplies are installed, but only single power supply
is operating
Fan Status LED
• Solid Green – FAN is operating normally
• Solid Amber – FAN is failed including incompatible airow direction
25G SFP28 slots
• Off – No link
• Solid Green – A valid link 25G link
• Solid Yellow – A valid link 10G link
• Blinking Green – Packet transmission or reception in progress
Page 8
5
AG5648 Leaf/ToR Switch
LED Description
100G QSFP28 slots
LED1
• Off – No link
• Solid Green – A valid 100G link
• Solid Amber – A valid 40G link
• Solid Blue – A valid 10Gbps link
• Solid Purple – A 10Gbps link
LED 2 and 4 (working in breakout)
• Off – 40/100G operation (assuming LED1 is illuminated) or No link
• Solid Blue – A valid 25Gbps link
• Solid Purple – A valid 10Gbps link
Management port
Link LED
• Off – No link is established on the port
• Solid Yellow – A valid link at 10/100Mbps is established on the port
• Solid Green – A valid link at 1000Mbps is established on the port
Act LED
• Off – No link is established on the port
• Blinking Green – Activity, transmitting or receiving packet at this port
2.2.2 Rear LEDs
Power Supply LED
Fan Tray LED
(Figure 2-4: Rear LED Identification)
LED Description
Fan Tray LED
• Solid Green – Fan operating normally
• Solid Red – Fan failed
Power Supply LED
• Off – No power or power supply failed
• Solid Green – Power is ok
Page 9
6
• Appearance and MechanismChapter 2
2.3 System Requirements
Component Requirement
System requirements
Switch fabric capacity Non-blocking full wire speed on all packet sizes
Forwarding architecture Store and forward or cut-through
Port packet forwarding rate (at 64 Bytes)
14880000 pps (10Gb)
MAC address entries supported
Up to 136K entries
Memory type 16MB buffer memory
OOB port 10/100/1000Mbps, auto sensing, auto negotiation
Host Support
• IPv4: 8K min./72K max.
• IPv6: 4K min/36K max.
LPM Route Support
• w/o URPF: IPv4 128K, IPv6/64 85K, IPv6/128 21K
• w/ URPF: : IPv4 64K, IPv6/64 21K, IPv6/128 5K
Priority Queues 20 priority queues per port
MAC Address Aging Support
1,000,000 seconds programable (Default 300 seconds)
Spanning Tree Support
• Support IEEE802.1d STP
• Support IEEE802.1s MSTP
• Support IEEE802.1w RSTP
Host Support 136K shared entries with MAC Table
LPM Routes Support 128K shared entries with MAC Table
Serial Console
• Provide visual feedback of the boot process to the user
• Timeout after period of inactivity
Port Trunking
• IEEE802.3ad Link Aggregation Protocol (LACP)
• Up to 1024 groups with 256 member per group
Port requirements
Speed Capability per Port
• 10G/25Gbps (SFP28 port)
• 40G/100Gbps (QSFP28 port)
• 10G/25G/40G (QSFP28 port, working in breakout)
Full-Duplex Flow Control Support the IEEE 802.3x PAUSE frame
Page 10
7
AG5648 Leaf/ToR Switch
2.4 Data Center Deployment
The following gure illustrates the converaged Ethernet data center deployment.
Spine
Leaf
6x100G uplink
25G downlink via Breakout cable
AG5648
25G downlink
AG5648
25G downlink
AG5648
25G downlink
AG9032 v1 AG9032 v1 AG9032 v1 AG9032 v1
AG9032 v1
(Figure 2-5: Converaged Ethernet Data Center Deployment)
2.5 Power Supply Modules
The power supply modules are hot-swappable power supply units (PSUs) for the switch. You can install up to two PSUs. The PSUs operate in a load-sharing mode and provides 1+1 redundancy.
(Figure 2-6: Power Supply Unit)
NOTE:
1+1 redundancy is a system where a switch power supply is backed up by another switch power supply in a load-sharing mode. If one power supply fails, the other power supply takes over the full load of the switch.
WARNING:
• The switch includes plug-in power supply and fan tray modules that are installed into its chassis. All modules have a front-to-back airow direction.
• Risk of explosion if battery is replaced by an incorrect type. Dispose of used batteries according to the instructions.
• Remove the power cable from the module prior to removing the module itself. Power cable must not be connected prior to insertion in the chassis or equivalent.
Page 11
8
• Appearance and MechanismChapter 2
2.6 Fan Tray Module
The fan tray module is part of the switch air cooling system that provides cooling for the
switch. You must install the fan tray module in the switch that matches the airow direction
of the installed power supply unit.
(Figure 2-7: Fan Tray Module)
Page 12
9
AG5648 Leaf/ToR Switch
Chapter 3: Installation
3.1 Mounting
This switch can be mounted in a standard 19-inch equipment rack or on a horizontal surface.
Mounting instructions for each type of site follow.
3.1.1 Rack Mounting
Prior rack mounting the switch, pay particular attention to the following factors:
Mechanical Loading: Do not place any equipment on top of a rack-mounted unit.
Circuit Overloading: Be sure that the supply circuit to the rack assembly is not overloaded.
Grounding: Rack-mounted equipment should be properly grounded. Particular attention
should be given to supply connections other than direct connections to the mains.
To rack-mount devices:
1. Attach the two brackets to the device using the eight M4 screws provided in the rack
mounting kit.
NOTE:
The switch can also be mounted in a rack using a rack shelf or rack “L” brackets.
(Figure 3-1: Attaching the Brackets)
2. Mount the device in the rack, using four 12-24 rack-mounting screws.
NOTE:
Rack screws and clip nuts are not supplied in the rack-mounting kit.
CAUTION:
Due to the switch’s weight, it should be installed by at least two people.
Page 13
10
• InstallationChapter 3
(Figure 3-2: Installing the Switch in a Rack)
3. If installing a single switch only, go to Connecting to a Power Source.
4. If installing multiple switches, mount them in the rack, one below the other, in any order.
3.1.2 Horizontal Surface Mounting
The switch includes four pre-installed rubber feet for horizontal surface mounting.
To mount devices on a horizontal surface, follow these steps:
1. Attach the four adhesive feet to the bottom of the rst switch.
(Figure 3-3: Attaching the Adhesive Feet)
2. Set the device on a at horizontal surface near an AC power source, making sure there are
at least two inches of space on all sides for proper air ow.
3. If installing a single switch only, go to Connecting to a Power Source.
4. If installing multiple switches, attach four adhesive feet to each one, then place each device
squarely on top of the one below, in any order.
Page 14
11
AG5648 Leaf/ToR Switch
3.2 Installing an Optional Transceiver and Cable
The SFP28 slots support the following optional transceivers and cables:
25GBASE-SR
25GBASE-LR
25GBASE AOC
25GBASE DAC
10GBASE-SR
10GBASE-LR
10GBASE AOC
10GBASE DAC
The QSFP28 slots support the following optional transceivers and cables:
100G Base-SR4
100G Base-LR4
100G AOC (Active Optical Cable)
100G DAC (Direct Attached Cable)
100G to 4x25G AOC
100G to 4x25G DAC
40G Base-SR
40G Base-LR4
40G AOC (Active Optical Cable)
40G DAC (Direct Attached Cable)
(Figure 3-4: Inserting an SFP28 Transceiver into a Slot)
(Figure 3-5: Inserting a QSFP/QSFP28 Transceiver into a Slot)
To install an SFP+, SFP28, QSFP or QSFP28 transceiver, follow these steps:
1. Consider network and cabling requirements to select an appropriate SFP+, SFP28, QSFP or QSFP28 transceiver type.
2. Insert the transceiver with the optical connector facing outward and the slot connector facing down. Note that SFP+, SFP28, QSFP or QSFP28 transceivers are keyed so they can only be installed in one orientation.
Page 15
12
• InstallationChapter 3
3. Slide the SFP+, SFP28, QSFP or QSFP28 transceiver into the slot until it clicks into place.
NOTE:
• SFP+, SFP28, QSFP or QSFP28 transceivers are hot-swappable. The switch does not need to be powered off before installing or removing a transceiver. However, always rst disconnect the network cable before removing a transceiver.
• SFP+, SFP28, QSFP or QSFP28 transceivers are not provided in the switch package.
QSFP28 Ports to SFP28 Ports: The AG5648 also supports splitting a 100G QSFP28 port into 25G ports via the breakout cables. Do consult your software provider for port mode change and conguration.
3.3 Connecting to the Console Port
This port is used to connect a console device to the switch through a nullmodem serial cable.
The console device can be a PC or workstation running a VT-100 terminal emulator, or a
VT- 100 terminal.
NOTE:
An RJ-45-to-DB-9 cable is not supplied with the switch for connecting to a PC’s RS-232 serial DB-9 DTE port.
DP-9 port
RJ-45 connector
(Figure 3-6: Console Port Connection)
Page 16
13
AG5648 Leaf/ToR Switch
3.4 Connecting to a Power Source
3.4.1 Installing an AC Power Supply
To connect a switch to a power source:
1. Insert the power cable plug directly into the AC socket of a PSU located at the back of the
switch.
Power socket
(Figure 3-7: Power Socket)
2. Plug the other end of the cable into a grounded, 3-pin, AC power source.
NOTE:
For International use, you may need to change the AC line cord. You must use a line cord set that has been approved for the socket type in your country.
3. Check the PSU and front-panel LEDs as the device is powered on to be sure that AC
power is being received and the Power LED is on. If not, check that the power cable is
correctly plugged in.
4. Repeat steps 1 and 2 when a second PSU module is installed.
Two installed PSU modules operate in a load-sharing mode and provide 1+1 redundancy.
3.4.2 Installing a DC Power Supply
Two types of connection to a power source:
a. DC power cord for DC source connection
1. Insert the power cable plug directly into the DC socket of a PSU located at the back of the
switch.
GND
-48V(-DC)
-48V_RTN (+DC)
(Figure 3-8: Installing a DC Power Supply and Power Cable)
Page 17
14
• InstallationChapter 3
2. Plug the other end of the cable into DC power source. This product is intended to be
supplied by DC power source with rated -40 ~ -72Vdc, 16A minimum, Tma = 40 degree C,
and the altitude of operation = 3048 m. The power cable should be 14AWG (16A minimum,
72V minimum).
CAUTION:
• Reversing polarity when connecting DC power wires can permanently damage the power supply or the system.
• Always disconnect the power cable from power source before you service the power supply slots.
3. Check the PSU and front-panel LEDs as the device is powered on to be sure that DC
power is being received and the Power LED is on. If not, check that the power cable is
correctly plugged in.
4. Repeat steps 1 and 2 when a second PSU module is installed.
Two installed PSU modules operate in a load-sharing mode and provide 1+1 redundancy.
b. Adapter connector for DC source connection
1. Attach the connector directly into the DC socket of a PSU located at the back of the switch.
GND
-48V(-DC)
-48V_RTN (+DC)
(Figure 3-9: Assembling a DC Connector and Power Wires)
2. Plug the other end of power wires into DC power source. This product is intended to be
supplied by DC power source with rated -40 ~ -72Vdc, 16A minimum, Tma = 40 degree C,
and the altitude of operation = 3048 m. The power cable should be 14AWG (16A minimum,
72V minimum).
CAUTION:
• Reversing polarity when connecting DC power wires can permanently damage the power supply or the system.
• Always disconnect the power cable from power source before you service the power supply slots.
3. Check the PSU and front-panel LEDs as the device is powered on to be sure that DC
power is being received and the Power LED is on. If not, check that the power cable is
correctly plugged in.
4. Repeat steps 1 and 2 when a second PSU module is installed.
Two installed PSU modules operate in a load-sharing mode and provide 1+1 redundancy.
Page 18
15
AG5648 Leaf/ToR Switch
Chapter 4: Making the Network Connections
The AG5648 switch is designed to provide high-speed, lossless Ethernet connections
between server racks through its 25G SFP28 or 100G QSFP28 ports. This chapter describes
how to make network connections to the switch.
4.1 Twisted-pair Connections
The switch’s Management port connection requires an unshielded twisted-pair (UTP)
cable with RJ-45 connectors at both ends. Use Category 5, 5e or 6 cable for 1000BASE-T
connections, Category 5 or better for 100BASE-TX connections, and Category 3 or better for
10BASE-T connections.
4.1.1 Cabling Guidelines
The RJ-45 port on the switch supports an automatic MDI/MDI-X pinout conguration, so
you can use a standard straight-through twisted-pair cable to connect to any other network
device (PCs, servers, switches, routers, or hubs).
4.1.2 Connecting to the Management Port
1. Attach one end of a twisted-pair cable segment to the link device’s RJ-45 connector.
RJ-45 connector
(Figure 4-1: Making a Connection to the Management Port)
2. Attach the other end to the Management port on the switch.
Make sure the twisted pair cable does not exceed 100 meters (328 ft) in length.
3. When the connection is made, the Mgmt LED (on the switch) will light green to indicate that
the connection is valid.
Page 19
16
• Making the Network ConnectionsChapter 4
4.2 Fiber Optic Connections
Optional 25G SFP28 or 100G QSFP28 transceivers can be used for ber connections from
the switch to other network devices in the data center. An SFP28 or QSFP28 transceiver may
also be used for long distance connections to devices at another site.
WARNING:
• When selecting a ber SFP28 or QSFP28 device, considering safety, please
make sure that it can function at a temperature that is not less than the
recommended maximum operational temperature of the product. You must
also use an approved Laser Class 1 SFP28 or QSFP28 transceiver.
The following gure illustrates the SFP28 or QSFP28 port ber connection.
(Figure 4-2: Making SFP28 Port Fiber Connection)
(Figure 4-3: Making QSFP28 Port Fiber Connection)
Page 20
17
AG5648 Leaf/ToR Switch
4.3 Ethernet Cabling
To ensure proper operation when installing the switch into a network, make sure that the
current cables are suitable for 10BASE-T, 100BASE-TX or 1000BASE-T operation. Check the
following criteria against the current installation of your network:
• Cable type: Unshielded twisted pair (UTP) or shielded twisted pair (STP) cables with RJ- 45 connectors; Category 3 or better for 10BASE-T, Category 5 or better for 100BASE-TX, and Category 5, 5e or 6 for 1000BASE-T.
Protection from radio frequency interference emissions
Electrical surge suppression
Separation of electrical wires (switch related or other) and electromagnetic elds from
data based network wiring
• Safe connections with no damaged cables, connectors or shields
Page 21
18
Appendix 1 : Technical Specifications
Item Description
Key components
Switch controller BCM56963 x 1
PHY BCM5461S x 1
CPU Intel Rangley C2538 2.4Ghz
Flash ROM 16 MB SPI Flash
System memory 4GB DDR3 SO-DIMM
mSATA Device 8GB SSD
Network Protocol and Standards Compatibility
Network protocol/ compatibility
IEEE 802.3ba 100Gb/s Ethernet
IEEE 802.3 10Base-T on console port
IEEE 802.3u 100Base-TX on console port
IEEE 802.3ab 1000BASE-T on console port
IEEE 802.3x Flow-Control
IEEE 802.3z 1000BASE-X
IEEE 802.3ae 10Gb/s Ethernet
Interface Information
Interface
Small Form-factor Pluggable 28 (QSFP28) slot x 48
Quad Small Form-factor Pluggable 28 (QSFP28) slot x 6
10/100/1000Mbps Management port x 1
RJ45 Console port x 1
USB port x 1
Power Supply Unit
Type AC-in PSU DC-in PSU
Max. output power 550W 550W
Input voltage AC 100 ~ 240V DC -48 ~ -60V
Output voltage DC 12V DC 12V
Physical
Dimensions (W x D x H) 438.5 x 460 x 43.0 mm (17.26 x 18.11 x 1.69 inches)
Weight 7.99 kg (17.61 lbs)
Environmental Specifications
Operating temperature 0 to 40°C
Storage temperature
-20 to 70°C
Operating humidity
10 to 90% RH
Storage humidity
5 to 95% RH
Page 22
19
AG5648 Leaf/ToR Switch
Appendix 2 : Warranty
Limited and Support Warranty
Three Years End-User Guarantee.
The new product you purchased from Agema or Agema authorized resellers (“Resellers”) will
be free from defects in materials, workmanship, and design affecting normal use, for a period
of three (3) years from the original purchase date. This warranty does not include accessories
or any free bundled sales items which may have been delivered along with the product. The
original purchasing invoice and the serial number on your product are both required when you
request for any warranty service.
During the warranty period, products for which proper claims are made will, at Agema’s
option, be repaired or replaced at Agema’s expense. Customers may contact Agema’s
technical support for warranty services, which may be provided either through Resllers or by
Agema directly. Agema owns all parts removed from the repaired products. Agema will use
new or reconditioned parts made by various manufacturers to perform repairs and/or to build
replacement products. All replaced or repaired products will be warranted for the remainder
of the original warranty period or thirty (30) days, whichever is longer.
Unless otherwise having a separate service level agreement (SLA) with Agema, you may
only have any in-warranty product returned to Agema for repair or replacement in a normal
turnaround time which differs according to geographic areas.
EXCLUSIONS
This Guarantee does not apply to defects resulting from: improper or inadequate installation,
use, or maintenance; actions or modications by unauthorized third parties or the end user;
accidental or willful damage; or normal wear and tear.
Technical Support
• For software related technical support and product return policy, please contact your software providers.
• For hardware related technical support, please send your e-mail to techsupport@agemasystems.com.
Please note that hardware related issues are limited to the following situations:
System Self-Diagnostic Test Failure
Product is physically damaged on arrival
Missing items in the package (see Package Content)
The product does not power on
Fan failure
Page 23
20
• WarrantyAppendix 2
Return Policy
Any product returned to Agema or Resellers without prior Return Material Authorization
(RMA) from Agema will be considered an unauthorized return, and you will not receive any
repair or replacement for the product and Agema will not ship the product back to you. The
authorization will be provided through the e-mail: techsupport@agemasystems.com.
For in-warranty defective product return, you shall be responsible for proper packaging and
Agema will not take responsibility for any shipping damage due to your improper product
packaging.
Disclaimer
EXCEPT FOR THE WARRANTIES EXPRESSLY SET FORTH IN THIS “LIMITED AND
SUPPORT WARRANTY”, AGEMA MAKES NO OTHER WARRANTIES REGARDING THE
PRODUCT, ANY PARTS INCORPORATED THEREIN OR ANY SERVICES PROVIDED
THEREWITH AND HEREBY DISCLAIMS ANY AND ALL SUCH OTHER WARRANTIES,
EXPRESS, IMPLIED OR STATUTORY, INCLUDING, BUT NOT LIMITED TO, ANY
WARRANTIES OF MERCHANTABILITY OR FITNESS FOR PARTICULAR PURPOSE,
WHICH ARE ALL HEREBY EXCLUDED.