Delta 630 User Manual

DELTA 630 Master
Centralised programmer
DELTA 630 Master
Unit compliant with the requirements
of directives: R&TTE 1999/5/CE (radio)
Installation
*2702091_Rev.1*
• Programming the activation / shutdown of the heat pump
• Managing change-over (summer / winter)
• Programming for 6 separate zones
Configuration / Use
To associate, configure and use your unit, refer to the DELTA 630 pack instructions (Management for ductable air conditioning system).
Technical characteristics
• Power supplied by two 1.5 V LR03 or AAA alkaline batteries, included, range about 2 years under normal use
• Class III insulation
• Clock backup when replacing the batteries: 30 seconds
• Radio range: 100 to 300 metres outside, variable depending on the associated equipment (the range can vary depending on the installation conditions and the electromagnetic environment)
• Radio frequency 868 MHz, class I (standard EN 300 220)
• Wireless remote control device
• Backlit display
• Dimensions: LxHxD: 80 x 103 x 16 mm
• Protection index: IP 30
• Storage temperature: -10°C to +70°C
• Operating temperature: 0°C to +40°C
• Installation in an environment with normal pollution levels
• Attachment with screws or on a base
Because of changes in standards and equipment, the
characteristics given in the text and the illustrations in
this document are not binding unless confirmed
Battery replacement
Attachment with screws
Attach the base using screws and plugs suitable for the support or to a flush-mounting box, then close and lock the unit.
The DELTA 630 Master can be installed:
- on the wall, at a height of about 1.5 m, with screws / plugs,
- on a wall mount, placed on a piece of furniture or on a shelf.
Separate the unit from its base by unlocking the unit.
Activation
The first time you activate the unit, you must set the clock. Remove the protective tab from the batteries.
Fitting the thermostat to its base
Press + or - to set the day, then OK to confirm and go to the next setting.
Repeat these steps to set the hour and minutes.
To exit the “time setting” mode, turn the selector knob.
Setting the time
Turn the selector knob to .
The days flash.
When the battery level symbol appears, you have approximately 1 month to replace them (two 1.5 V alkaline batteries, either LR03 or AAA).
Place the thermostat on its base
Lock the thermostat
Battery level symbol
Bonnemain - 35270 COMBOURG - France
E-mail : deltadore@deltadore.com
Minutes
Days
(1: Monday ... 7: Sunday)
Hours