Delta 620 DRIVER Installation

*2702120_Rev.1*
Installation guide
Unit compliant with the requirements of directives:
2004/108/EC (Electromagnetic Compatibility)
and 2006/95/EC (Low-Voltage Safety)
Because of changes in standards and equipment, the characteristics given in the text and the illustrations in this document are not binding unless confirmed by our services.
• Carefully read these instructions prior to installation.
• The unit must be installed in compliance with cur­rent standards.
• Always switch off the mains before installing or ser­vicing the unit.
• Do not attempt to repair the unit yourself; an after­sales service is available.
• Check that the fastenings are suited to the surface to which the unit will be attached (plas­terboard, brick, etc.).
• The diagrams provided are simplified for greater cla­rity.Protections and other accessories required by standards are not illustrated. Standard UTE NF C15-100 and good practice must be complied with. Connected or nearby units must not generate excessive interference (directive 2004/108/EC).
Warning
s
Connection
DRIVER 610 DRIVER 620
terminal 3
Convectors
zone 1
Convectors
zone 1
terminal 4 NC
Convectors
zone 2
s
DRIVER 610 DRIVER 620
The room unit must be installed at a height of approxi­mately 1.5 m, so that it is within arm’s reach for ease of use. To attach the unit to the wall, you must separate it from its base.To do so, unlock the casing.
Unscrew the terminal box cover and lift it up as high as it will go to block it, then position the base on the wall
running the wires out through the hole in the cover.
Secure the base using suitable screws and screw anchors or fit onto a flush-mounted box (distance between centres 60 mm).
Connect the control wires. Close the box and tighten the
terminal box cover screw.
Room unit mounting.
Output 2 test underway.
Repeat the operations for zone 1. Check the incorrect connections. To exit test mode, press the
init button.
s
Checking the pilot wire connections
Put all of the installation’s convectors on Comfort (with the set-point on its maximum setting).
When the unit is switched on, a test lasting about 1 minute 30 seconds checks that the outputs are cor­rectly connected.
If the display remains “normal”, this means there are no problems. If a problem exists, the DRIVER displays Pb - - .
The first time you activate the unit, you must set the clock.
Turn the knob to .
The days flash.
Press + or - to set the day, then OK to confirm and go to the next setting. Repeat these steps for the other menus.
To exit the “time setting”mode, turn the selector knob.
Activation
DRIVER
Pilot wire programmer
DRIVER 610 - 1 projecting zone
DRIVER
NCNL
Zone 1 Pilot Wire Convector
NL
Zone 2 Pilot Wire Convector
Zone 1 Pilot Wire Convectors
Bonnemain - 35270 COMBOURG - France
DELTA DORE
E-mail : deltadore@deltadore.com
Exit and relaunch text mode
Launch the test output by output
Choose the output to test
Approve and restart the test for the chosen output Example: test for output 2
The output's number becomes fixed
Connection of output
2 incorrect
OR
The output's number disappear
Connection of output
2 correct
Minutes
Days
(1: Monday ...
7: Sunday)
Hours
To enter the configura­tion menus:
- Turn the knob to , then press and hold the
i button for 5
seconds.
The unit will propose 2 configurations to choose from:
After each menu has been configured, the unit returns to the choice of menus. If you want to exit configuration, turn the selector knob to the right.
Configuration
Press button 2.
To modify the various settings, press the + or - buttons, then press the OK button to validate and go to the next setting.
Advanced configurations (menu 2)
Basic configurations (menu 1)
Press button 1.
To modify the various settings, press the + or - buttons, then press the OK button to validate and go to the next setting.
If there is a difference between the actual temperature (taken with a thermometer) and the temperature mea­sured and displayed by the unit, function 2-02 can be used to compensate for the difference by changing the way the sensor takes measurements.
Example: If the temperature displayed by the unit is 19°C and the temperature measured is 20°C, add 1°C to the display and confirm by pressing OK.
The factory settings may be restored for each of the menus.
Turn the knob to , then press and hold the
i button
for 5 seconds.
Repeat these steps for the other menus. To exit the mode, turn the knob to another mode.
Return to the factory configuration
Summary table of configurations
1-01
Type of program
0 = weekly 1 = daily
1-02
No program
0 = 1 hour 1 = 30 minutes 2 = 15 minutes
2-01
Modification authorization 0 = Program modifiable 1 = Non modifiable program
2-02
Correction of the temperature measured
by -5°C to +5°C in increments of 0.1°C.
Help
Nothing is displayed on the room unit screen. There is no power supply.
Check the circuit breaker.
Pb — is displayed on the screen. Problem with the connection on a Pilot Wire output.
Contact our technical department.
thei symbol flashes. A fault is detected on the installation.
Press the button to view the fault(s).
The device displays: dEF and a number There is a fault with the unit which requires a return to our after-sales service.
Contact our technical department.
Technical characteristics
• 230 V, 50 Hz power supply, ±10%
• Consumption: 2 VA
• Class II insulation
• 1 or 2 pilot wires output 0.1A / 230V
• Clock backup in the event of a blackout: 2 hours (per capacitor)
• Dimensions: WxHxD = 80 x 103 x 16 mm
• Protection index: IP 30
• Installation in an environment with normal pollution levels
• Storage temperature: -10°C to +70°C
• Operating temperature: 0°C to +40°C
Unit reference number (for example, DRIVER 620)
Basic configurations
Advanced configurations
Unit version
Configuration mode
5 sec.
Weekly (by default)
Programming type selection
Choix du pas de programmation
Daily
pas d'1 heure (par défaut) pas de 30 minutes pas de 15 minutes
Program modification authorized
Modification authorization for the user
Program modification unauthorized
Correction possible from -5°C to + 5°C
Correcting the temperature measured.
in increments of 0.1°C. Press the + or – buttons to modify, and press the OK button to confirm.
Hold down the menu button you want to reinitialize for 5 seconds (example here with menu 1).
Then press the OK button to confirm the reset.