Presentation
This unit is used to program the Comfort or Economy mode of the heating for 1 zone (DRIVER 610 or 611) or 2 zones (DRIVER 620 or 621),
To control the heat emitters, the programmer uses the Pilot Wire.
Independent from the power supply of the heat emitter, the Pilot Wire is used to send the Comfort , Economy , Frost Protection or Shutdown orders
requested by the programmer. The required temperature is set on the thermostat of
each heat emitter (convectors, panel heaters, under­floor heating or radiant ceiling heating, towel warmer radiators, storage heaters, etc.).
IMPORTANT: The heat emitter must be in automatic mode (PROG, AUTO, , etc. depending on model) to receive orders from the programmer..
Options
The following options are only available on the DRI­VER 611 or 621.
TYPHONE 500
When associated with the DRIVER 611 or 621, the TYPHONE 500 allows you to control your heating remotely by telephone.
MINOR 500
Regulates an underfloor heating or radiant ceiling hea­ting system. In combination with the DRIVER 611 or 621, this unit is used to control the set points and determine the room temperature measured by each probe.
Description
This guide is common to the DRIVER 610, 611, 620 or
621.
• Carefully read these instructions prior to use.
• Do not attempt to repair the unit yourself; after­sales service is available.
Warnings
Override
In automatic mode, override is used to go from Comfort to Economy mode (or conversely) until the next program change.
Turn the knob to AUTO.
DRIVER 610 or 611 follows the programming.
DRIVER 620 or 621 follows the programming in both
zones.
Automatic mode
Continuous mode
Timer mode
This mode allows you to choose a continuous mode for each of the zone.
Turn the knob to , then press the modification but­ton of the relevant zone to select the Comfort or Economy . mode.
This mode shuts down your heating system. Turn the knob to .
Shutdown mode
Absence mode
Turn the knob to .
The days flash.
Press + or - to change the day, then press OK to confirm and continue on to the next setting.
Repeat the operations to set the hours and minutes. To leave the “setting the time” mode, turn the knob.
Time setting
NOTE : If the unit is configured for a daily program, the days setting is not offered.
During the AUTO, or modes, press the i button repeatedly to find out:
• if you have the MINOR 500 option, the temperature measured by each of the probes declared during the installation.
• the program of the current day per zone,
Information button
DRIVER 610 or 611
DRIVER 620 or 621
To exit this mode, turn the knob.
DRIVER
Pilot wire programmer
DRIVER 610 or 620 - 1 or 2 zones, projecting
DRIVER
Programmer
Pilot Wire orders
Pilot wire
Heat emitters
Pilot Wire
order
(mode)
Comfort
Economy
Absence
Shutdown
Setting on the heat emitter
Comfort setting (thermostat knob) example : 19°C
Economy setting (thermostat knob) example : 16°C or Comfort –X°C (depending on heat emitter model)
Frost protection set to 7°C or 8°C (depending on model)
Heating shutdown
Room
temperature
19°C
16°C
7°C or 8°C
No heating
Bonnemain - 35270 COMBOURG - France
DELTA DORE
E-mail : deltadore@deltadore.com
DRIVER
Selector
knob position
Shutdown mode Absence mode Timer mode Automatic mode Continuous mode
This mode is used to select a mode for a given time and for one zone only. Turn the knob to
Choice of the zone proposed on the DRIVER 620 or 621 (the other zone follows the AUTO mode)
Confirm
Selection of the Economy or Comfort mode
Confirm
Time setting Programming
Modification
buttons
Selector
knob
Current day
Time
Current mode
Room
temperature
Display in automatic mode
Override
Information button
Current mode in zones 1 and 2
Override for zone 1
Override for zone 2
Information button
Current day
Room
temperature
Time
Display in automatic mode
Room
temperature
Current mode
Modification of the mode
Example: it is 15:30 and you would like to switch to Comfort mode before the set time (17:00).
6:00 8:00
Current day programming on zone 1
To cancel the current override, press the button once more.
Press the override button of zone 1.
Current override on zone 1.
17:0015:30 23:00
At 17:00, the program will
return to its usual program.
00:0000:00
This mode lets you place your home under Frost Protection if you need to leave for several days.
Turn the knob to .
Adjustment of the number of days (1 to 365) Example: for a departure on 1 March and a return on 10 March, program 9 days of absence. Automatic operation will resume on 10 March at midnight.
Confirm and start the calendar countdown.
Adjustment of the duration from 15 minutes to 72 hours (in increments of 15 minutes)
Confirmation and start of the countdown
Return to AUTO mode at the end of the countdown
To cancel the current
timer mode, turn the knob.
Room
temperature
Room
temperature
Current mode in zones 1 and 2
Modification of the mode in zone 1
Modification of the mode in zone 2
probe no.
temperature measured by the probe
Indication of a probe or probes on the installation
Return to AUTO mode at the end of the countdown
To cancel the current absence mode, turn the knob.
Minutes
(1 : Monday… 7 : Sunday)
Days
Hours
Comfort periods
MINOR 500 option: set point settings
Check your program
Press the button repeatedly to check the accuracy of the Comfort and Economy periods you created.
Programming zone 2 (on the DRIVER 620 or 621) The programming for zone 2 is available after pressing
(
OK) of the day 7 of the zone 1.
Exiting the programming mode
Turn the knob to another mode.
COMMENTS : Depending on the configuration made during installation, programming can be weekly or daily. Likewise, this programming may be done in increments of one hour, 30 minutes, or 15 minutes.To change these settings, refer to the “installation guide”, or contact our customer service department or your installer.
When setting the time, there is no option to set the day.
You are in daily programming.
To switch to weekly programming, refer to the installation guide or contact your installer or our customer service depart­ment.
The temperature displayed does not match the tempera­ture measured in the room (thermometer).
Refer to the installation guide or contact your installer or our customer service department.
The unit displays HEAT
Your underfloor heating or radiant ceiling heating system is in “gradual heating” mode.
If you want to know the number of days remaining, press the
i
button.
The heating elements are in Frost Protection mode
You are in programming mode, the absence mode or time setting mode.
Turn the knob to select another mode.
Pb ---- is displayed on the screen.
Problem with the connection of a heating element.
Contact your installer or our customer service department.
Nothing is displayed on the room unit screen.
There is no power supply.
Check your circuit breaker.
The i symbol flashes.
A fault has been detected in the system.
Press the button to consult the fault or faults.
The unit displays: dEF and a number.
There is a fault on the unit or the installation.
Contact your installer or our customer service department.
The unit displays ---- instead of the temperature measured by each MINOR 500 probe.
There is a problem on at least one of the probes.
Contact your installer or our customer service department
.
The unit is in time setting mode.
There was a mains disruption that lasted more than 2 hours.
Set the time. All other settings have remained unchanged.
Troubleshooting
The purpose of this section is to help you quickly solve the most common problems that you may encounter with your product during use. If you're unsure, or if the problem persists or isn't in this list, contact our customer service department.
Programming
Turn the knob to PROG. The default program is a Comfort period from 6:00 to 23:00.
1. Create your program
Programming starts on day 1 at midnight. Press the or buttons to create different Economy
or Comfort periods.
2. Confirm and copy the program
Press and hold the OK button for 3 seconds to confirm the program you created and copy it to the next day.
3. Confirm the program
Press the OK button to confirm and continue on to the next day to program it separately.
Comf
Example: Comfort from 6:00 to 8:00 and from 17:00 to 23:00
6:00 8:00 00:0000:00 17:00 23:00
Day
Available on the DRIVER
620 or 621
1st time slot
ort period
adjustment Economy period
adjustment
This mode is used to modify the Comfort and Economy set points of each probe. Turn the knob to .
Setting (5 to 30°C) of the Comfort set point (19°C by default) for the probe 1 of zone 1.
Confirm and go to the next setting.
Setting (5 to 30°C) of the Economy set point (16°C by default) for the probe 1
of zone 1. Confirm and go to the set point settings
for the next probe.
Repeat the operations for each probe. When the last probe is set, you can set the Frost Protection set point for all the zones.
Setting (5 to 15°C) of the Frost Protection set point (8°C by default) for all the zones.
Confirm the modification
To exit the mode, turn the knob to another mode.
Press until you reach 6:00
Press until you reach 8:00
Press until you reach 17:00
Press until you reach 23:00
Press until you reach 00:00
Copy and confirm
or confirm
Time slot
consulted
Program
profile
Verification of the different or periods