TYBOX 610
Weekly programmable thermostat
User guide
This appliance is compliant with the requirements of
directives 2004/108/EC (Electromagnetic Compatibility)
and 2006/95/EC (Low-Voltage Safety)
Because of changes in standards and equipment, the characteristics given in the text and the illustrations provided in this
document are not binding unless expressly confirmed
*2702304_Rev.3*
1 - Description
Thermostat
Selector dial
Information
button
Selector dial
Modification
buttons (function
dependent)
Manual mode
Shutdown
Set-point
temperature setting
Configuration mode
Time setting
Programming
Automatic mode
2 - Time setting
Turn the selector dial to the position marked .
The day numbers flash.
• Press + or - to set the day, then OK to confirm and
go to the next setting.
Repeat these steps to set the hours and minutes.
To exit the “time setting” mode, turn the selector dial.
Days
Hours
Minutes
(1: Monday… 7: Sunday)
3 - Set-point temperature setting
Turn the selector dial to
This mode is used to select the setback and
comfort set-point temperatures.
Note:
Only the setback set-point temperature
will be available to you if you have opted
for the comfort setting for every radiator
(menu CF03) of the “installation guide”.
• Press + or - to set the comfort temperature,
then confirm with OK to move to the next
setting for the setback temperature.
Confirm again with OK.
The set-point temperatures are adjustable
from 5 to 30°C in heating mode and from
18 to 35°C in cooling mode in steps of
0.5°C. To set the cooling set-point tempe-
ratures, switch the thermostat to cooling
mode (refer to the heating / cooling mode
change menu).
Setting the comfort
temperature
Confirmation
Setting the setback
temperature
Confirmation
4 - Programming
• Create your programme
Programming starts on day 1 at midnight. Press the or buttons
to create different Setback or Comfort periods (in 1/2 hour intervals).
There are 2 possibilities for confirming
your programme:
• Confirm and copy the programme
to the next day
Hold down the OK button for 3 seconds to
confirm and copy the programme you just
created to the next day.
• Confirm the programme
Press the OK button to confirm and go to
programming for the next day.
Turn the selector dial to the position marked
The default programme is a Comfort period from 6.00am to 11.00pm.
The return key is used to modify a programme by returning to a specific time slot
OR
1st time slot
Set one 1/2 hour
period in setback mode
Set one 1/2 hour
period in comfort mode
Days
Return
button
Confirmation
button
Example: Comfort from 6.30am to
8.30 am and 5.30 pm to 11.00 pm
Press up to 06:30
Press up to 17:30
Press up to 00:00
Press up to 08:30
Press up to 23:00
Copy and confirm,
or confirm
5 - Automatic mode
Turn the selector dial to the position marked . Your thermostat will function according
to the programme.
NOTE:
By default, your unit will continuously display the set-point temperature. If you want to modify this
parameter, please refer to the CF02 menu of the “installation guide”, or contact your installer.
Current day
Time
Information
button
Request for
heat or cold
Room
temperature
Current
mode
Current day
programming
Absence
button
Timer
mode button
6 - Timer mode
This mode is used to choose a particular
mode for a given amount of time.
In AUTO mode, press on the button
• Press + or - to set the duration that you
want (between 30 minutes and 72 hours),
then on OK to confirm.
Example: Timer mode for 30 minutes.
• Press + or - to set the set-point temperature
that you want (from 5 to 30°C for heating
mode and from 18 to 35°C for cooling
mode), then on OK to confirm and start the
countdown.
Duration of timer mode
Cancel
Cancel Temperature
setting
Set-point
temperature
adjustment
Confirm
and begin
countdown
Setting the duration
Confirmation
Press on OK during Timer mode to modify
the settings.
To cancel the current Timer mode,
press on the button
Return to AUTO mode at the end of the countdown
• Carefully read these instructions prior to installation.
• Do not attempt to repair the unit yourself; an after-sales service is available.
1234567
i
0h 2 4 6 8 10 12 14 16 18 20 22 2 4
2 4
TYBOX
2 1
18 202224
AUTO
PROG
23
23
1
1
ROG
6h30 8h30
17h30 23h
0h0h
7 - Absence mode
This mode protects your home from frost if
you are absent for several days.
In AUTO mode, press on the button
Number of days
Cancel
Confirmation
Setting the number
of days
8 - Manual mode
Turn the selector dial to
• Press + or - to set the
temperature you want,
then on OK to confirm.
To cancel manual mode,
just turn the selector dial.
Information
button
Confirmation
Confirmation
Setting the
temperature
Modifying
the set-point
temperature
9 - Shutdown mode
Turn the selector dial to
This mode shuts down your heating system.
NOTE:
Your installation will likewise be in shutdown mode in the following selector dial positions :
The screen displays the current
room temperature.
If you would prefer to display the time instead during a prolonged shutdown of your system,
turn the selector dial on the unit to the position marked .
10 - Heating / cooling change mode
(Only for reversible heat pumps)
To switch from heating mode (HEAT) to cooling mode (COOL) and vice versa from
either the or , press and hold the information button for at least 3 seconds.
The screen will briefly show the Cool indicator as well as the set-point temperature
before the TYBOX then switches into cooling mode. Alternate the Summer / Winter
switch of your reversible system in the
same way by using the following table:
At any time at all, a brief touch on the
i
button will show what the current mode is.
(changes are possible when the or indicator are displayed on the screen,
see menu CF04
Cooling mode is available only if the CF04 menu is programmed with a value of 1.
TYBOX
Heating mode
Reversible system
in winter mode
Cooling mode
in summer mode
Current
operatin
mode
indicator
lamp
Information button
Displays for 3 seconds
Heating mode
Cooling mode
In AUTO mode, pressing the ibutton gives you the temperature of the room or the
set-point temperature according to the installation configuration (the CF02 menu).
11 - Information button
Your thermostat displays the room
temperature, and another touch of the
i
button will display the set-point
temperature:
Your thermostat displays the set-point
temperature, and another touch of the
i
button will display the room
temperature:
Set-point
temperature
display
Room
temperature
display
When the battery level symbol appears,
you have approximately 1 month to replace
the batteries (two 1.5 V alkaline batteries,
either LR03 or AAA).
Precautions that must be taken :
- ensure that the +/- polarities are respected
when the batteries are fitted into the unit,
- do not dispose of used batteries inappropriately (you should respect the environment by taking used batteries to a suitable collection site),
- do not recharge the batteries.
- you have approximately 30 seconds to
change the batteries before the time is
reset to zero (if this happens, reset the date
and time) see the section on "Time setting".
12 - Replacing the batteries
Never use rechargeable batteries. Use only
alkaline batteries.
Battery level symbol
• Open the thermostat
housing by pressing
on clip
➊
and lifting
off the back cover.
• Insert 2 LR03-AAA
1.5 V alkaline batteries, making sure to
respect the battery
polarities.
• Put back the front
cover of the thermostat housing until the
clip locks into place
Turn the selector dial to
13 - Troubleshooting
Nothing is displayed on the room unit screen.
There are no batteries
Check the batteries
The temperature displayed does not match the temperature measured in the room
(thermometer).
Refer to the control unit guide or contact our customer service department.
This section is intended to help you quickly solve the most common problems that you
may encounter when using your product. If in doubt, and the problem persists or it is not
included in this list, please contact our customer service directly.
Your heating system is off.
Tybox is switched into ,
, ,
PROG or
NOTE: Before opening the housing of your thermostat, turn the selector dial to
• Press + or - to set the number of days
absent that you want (between 1 and 99),
then on OK to confirm.
To cancel the absence mode,
press on the button marked
• Press + or - to set the set-point
temperature that you want (from
5 to 15°C for heating mode),
then on OK to confirm and start
the countdown. The system will
be shut down if the Tybox is
in cooling mode.
Press on OK during Absence
mode to modify the settings.
Temperature setting
Cancel
Set-point
temperature
adjustment
Confirm
and begin
countdown
Return to AUTO mode at the end of the countdown
This mode is used to choose a set-point temperature
that remains constant.
Example: Leaving on 1st March, returning on 10th March: specify 9 days
of absence. Automatic operation will resume at midnight on 10th March.