Delta 50-850 User Manual

Page 1
INSTRUCTION MANUAL
1½ H.P. Single-Stage
Dust Collector
(Model 50-850)
PART NO. 902115 - 11-15-02
Copyright © 2002 Delta Machinery
ESPAÑOL: PÁGINA 15
To learn more about DELTA MACHINERY visit our website at: www.deltamachinery.com.
For Parts, Service, Warranty or other Assistance, please call
1-800-223-7278 (In Canada call 1-800-463-3582).
Page 2
2
GENERAL SAFETY RULES
Woodworking can be dangerous if safe and proper operating procedures are not followed. As with all machinery, there are certain hazards involved with the operation of the product. Using the machine with respect and caution will considerably lessen the possibility of personal injury. However, if normal safety precautions are overlooked or ignored, personal injury to the operator may result. Safety equipment such as guards, push sticks, hold-downs, featherboards, goggles, dust masks and hearing protection can reduce your potential for injury. But even the best guard won’t make up for poor judgment, carelessness or inattention. Always use common sense and exercise caution in the workshop. If a procedure feels dangerous, don’t try it. Figure out an alternative procedure that feels safer. REMEMBER: Your personal safety is your responsibility.
This machine was designed for certain applications only. Delta Machinery strongly recommends that this machine not be modified and/or used for any application other than that for which it was designed. If you have any questions relative to a particular application, DO NOT use the machine until you have first contacted Delta to determine if it can or should be performed on the product.
Technical Service Manager Delta Machinery 4825 Highway 45 North Jackson, TN 38305
(IN CANADA: 505 SOUTHGATE DRIVE, GUELPH, ONTARIO N1H 6M7)
WARNING: FAILURE TO FOLLOW THESE RULES MAY RESULT IN SERIOUS PERSONAL INJURY
1. FOR YOUR OWN SAFETY, READ INSTRUCTION
MANUAL BEFORE OPERATING THE TOOL. Learn the
tool’s application and limitations as well as the specific hazards peculiar to it.
2. KEEP GUARDS IN PLACE and in working order.
3. ALWAYS WEAR EYE PROTECTION.
Wear safety glasses. Everyday eyeglasses only have impact resistant lenses; they are not safety glasses. Also use face or dust mask if cutting operation is dusty. These safety glasses must conform to ANSI Z87.1 requirements. Note: Approved glasses have Z87 printed or stamped on them.
4. REMOVE ADJUSTING KEYS AND WRENCHES. Form
habit of checking to see that keys and adjusting wrenches are removed from tool before turning it “on”.
5. KEEP WORK AREA CLEAN. Cluttered areas and
benches invite accidents.
6. DON’T USE IN DANGEROUS ENVIRONMENT. Don’t
use power tools in damp or wet locations, or expose them to rain. Keep work area well-lighted.
7. KEEP CHILDREN AND VISITORS AWAY. All children
and visitors should be kept a safe distance from work area.
8. MAKE WORKSHOP CHILDPROOF – with padlocks,
master switches, or by removing starter keys.
9. DON’T FORCE TOOL. It will do the job better and be
safer at the rate for which it was designed.
10. USE RIGHT TOOL. Don’t force tool or attachment to do a job for which it was not designed.
11. WEAR PROPER APPAREL. No loose clothing, gloves, neckties, rings, bracelets, or other jewelry to get caught in moving parts. Nonslip footwear is recommended. Wear protective hair covering to contain long hair.
12. SECURE WORK. Use clamps or a vise to hold work when practical. It’s safer than using your hand and frees both hands to operate tool.
13. DON’T OVERREACH. Keep proper footing and balance at all times.
14. MAINTAIN TOOLS IN TOP CONDITION. Keep tools sharp and clean for best and safest performance. Follow instructions for lubricating and changing accessories.
15. DISCONNECT TOOLS before servicing and when changing accessories such as blades, bits, cutters, etc.
16. USE RECOMMENDED ACCESSORIES. The use of accessories and attachments not recommended by Delta may cause hazards or risk of injury to persons.
17. REDUCE THE RISK OF UNINTENTIONAL STARTING. Make sure switch is in “OFF” position before plugging in power cord.
In the event of a power failure, move switch
to the “OFF” position.
18. NEVER STAND ON TOOL. Serious injury could occur if the tool is tipped or if the cutting tool is accidentally contacted.
19. CHECK DAMAGED PARTS. Before further use of the tool, a guard or other part that is damaged should be carefully checked to ensure that it will operate properly and perform its intended function – check for alignment of moving parts, binding of moving parts, breakage of parts, mounting, and any other conditions that may affect its operation. A guard or other part that is damaged should be properly repaired or replaced.
20. DIRECTION OF FEED. Feed work into a blade or cutter against the direction of rotation of the blade or cutter only.
21. NEVER LEAVE TOOL RUNNING UNATTENDED. TURN POWER OFF. Don’t leave tool until it comes to a complete stop.
22.
STAY ALERT, WATCH WHAT YOU ARE DOING, AND USE COMMON SENSE WHEN OPERATING A POWER TOOL. DO NOT USE TOOL WHILE TIRED OR UNDER THE INFLUENCE OF DRUGS, ALCOHOL, OR MEDICATION. A moment of inattention while operating
power tools may result in serious personal injury.
23. MAKE SURE TOOL IS DISCONNECTED FROM POWER SUPPLY while motor is being mounted, connected or reconnected.
24. THE DUST GENERATED by certain woods and wood products can be injurious to your health. Always operate machinery in well ventilated areas and provide for proper dust removal. Use wood dust collection systems whenever possible.
SAVE THESE INSTRUCTIONS.
Refer to them often and use them to instruct others.
Page 3
3
ADDITIONAL SAFETY RULES FOR
DUST COLLECTORS
WARNING: FAILURE TO FOLLOW THESE RULES MAY RESULT IN SERIOUS PERSONAL INJURY.
1. DO NOT OPERATE THIS MACHINE until it is assembled and installed according to the instructions.
2. OBTAIN ADVICE FROM YOUR SUPERVISOR, instructor, or another qualified person if you are not
familiar with the operation of this machine.
3. FOLLOW ALL WIRING CODES and recommended electrical connections.
4. DO NOT leave the dust collector plugged into the electrical outlet. Unplug dust collector from the outlet when not in use and before servicing, changing bags, unclogging and cleaning.
5. ALWAYS turn all controls “OFF” before unplugging the dust collector.
6. TO REDUCE THE RISK OF ELECTRICAL SHOCK, do not use on wet surfaces. Do not expose to rain. Store indoors.
7. DO NOT use the dust collector to pick up flammable or combustible liquids, such as gasoline. NEVER use the dust collector near any flammable or combustible liquids.
8. USE the dust collector to pick up wood materials only. DO NOT use the dust collector to pick up metal shavings, metal dust, or metal parts.
9. NEVER use the dust collector to dissipate fumes or smoke. NEVER pick up anything that is burning or smoking, such as cigarettes, matches or hot ashes.
10. DO NOT pull the dust collector by the power cord. NEVER allow the power cord to come in contact with sharp edges, hot surfaces, oil or grease. Do not place anything over the top of the power cord.
11. DO NOT unplug the dust collector by pulling on the power cord. ALWAYS grasp the plug, not the cord.
12. DO NOT handle the plug or dust collector with wet hands.
13. REPLACE a damaged cord immediately. DO NOT use a damaged cord or plug. If the dust collector is not operating properly, or has been damaged, left outdoors or has been in contact with water, take it to an Authorized Service Center for service.
14. DO NOT use the dust collector as a toy. DO NOT use near or around children.
15. DO NOT insert fingers or foreign objects into the dust intake port or discharge port. Keep hair, loose clothing, fingers, and all body parts away from openings and moving parts of the dust collector.
16. DO NOT use with any opening blocked; keep openings free of dust, lint, hair, and anything that may reduce air flow.
17. NEVER use the dust collector without the dust collection bag in place and properly secured.
18. ALWAYS use intake cover to cover dust port when the dust collector is not in use or mounted to a supporting surface for storage.
19. PERIODICALLY INSPECT dust bag for any cuts, rips or tears. NEVER operate the dust collector with a damaged bag or vacuum hose.
20. USE EXTRA CARE when cleaning on stairs.
21. TURN THE MACHINE “OFF” AND DISCONNECT THE MACHINE from the power source before installing or removing accessories, before adjusting or changing set-ups, or when making repairs.
22. TURN THE MACHINE “OFF”, disconnect the machine from the power source, and clean the table/work area before leaving the machine. LOCK THE SWITCH IN THE “OFF” POSITION to prevent unauthorized use.
23. ADDITIONAL INFORMATION regarding the safe and proper operation of this tool is available from the Power Tool Institute, 1300 Summer Avenue, Cleveland, OH 44115-2851. Information is also available from the National Safety Council, 1121 Spring Lake Drive, Itasca, IL 60143-3201. Please refer to the American National Standards Institute ANSI 01.1 Safety Requirements for Woodworking Machines and the U.S. Department of Labor OSHA 1910.213 Regulations.
SAVE THESE INSTRUCTIONS.
Refer to them often
and use them to instruct others.
Page 4
4
UNPACKING AND CLEANING
Carefully unpack the tool and all loose items from the shipping container(s). Remove the protective coating from all unpainted surfaces. This coating may be removed with a soft cloth moistened with kerosene (do not use acetone, gasoline or lacquer thinner for this purpose). After cleaning, cover the unpainted surfaces with a good quality household floor paste wax. ILLUSTRATIONS ARE REPRESENTATIVE ONLY AND MAY NOT DEPICT THE ACTUAL COLOR, LABELING
OR ACCESSORIES AND MAY BE INTENDED TO ILLUSTRATE TECHNIQUE ONLY
Fig. 2
1 -Locking Bands for
Filter and Dust Collection Bags (2)
2- Filter Bag
3- Dust Collection Bag
4 - Filter Bag Support Rod
5- Extension Rod
6- Clamps (2)
7 -6" Dia. Flexible Hose
8 -Drum Support (3)
9 -Casters (3/8"
Lockwashers, 3/8-16 Hex Nuts) (4)
10 -“U” Bracket for Filter Bag
Support Rod
11 -Lower Dust Bag
retaining Clips (4)
Fig. 3
12 -Blower and Motor
Assembly 13 -Clamp 14 -4" Dia. Flexible Hose 15 - Intake Port 16 -Base 17 -Intake Caps (2) 18 -Drum
Fig. 2
Fig. 3
1
2
3
4
5
6
7
8
9
10
12
13
14
15
16
17
18
11
HARDWARE NOT SHOWN
* -5/16"-18 x 5/8"
Hex Head Screws (20)
* - 5/16" Lockwashers (24)
* -5/16"-18 Hex Nuts (12)
* -5/16" x 7/8" O.D.
Flat Washers (6)
* - M4.2 Sheet Metal
Screws (4)
* -1/4-20x5/8" Hex Head
Screws (8)
* -1/4" Lockwashers (8)
* -1/4"-20 Hex Nuts (8)
Page 5
5
ASSEMBLY
Fig. 4
Fig. 5
Fig. 6
Fig. 8Fig. 7
ASSEMBLING CASTERS TO BASE
1. Insert threaded rod of caster (A) Fig. 4, into the hole located on the underside of base (B) and fasten with 3/8" lockwasher (C) and 3/8-16 hex nut (D). Fig. 5, illustrates the caster fastened to the base.
2. Assemble the remaining three casters to the underside of the base in the same manner.
ASSEMBLING BLOWER AND MOTOR ASSEMBLY TO BASE
1. Turn base (A) Fig. 6, right side up. Align the mounting holes at the base of blower and motor assembly (B) Fig. 6, with six pre-drilled holes (C) in base (A) and fasten with six 5/16-18x5/8" hex head screws (D) and 5/16" lockwashers (E).
2. Fig. 7, illustrates the blower and motor assembly (B) fastened to base (A).
3. Assemble drum support (F) Fig. 8, to the two threaded holes in the corner of base (A), as shown in Fig. 8, with two 5/16-18x5/8" hex head screws and 5/16" lockwashers (G). NOTE: Do not completely tighten hardware at this time.
A
B
C
D
D
E
A
C
C
B
A
B
F
G
G
A
WARNING: FOR YOUR OWN SAFETY, DO NOT CONNECT THE MACHINE TO THE POWER SOURCE UNTIL THE MACHINE IS COMPLETELY ASSEMBLED AND YOU READ AND UNDERSTAND THE ENTIRE INSTRUCTION MANUAL.
Page 6
6
Fig. 9
Fig. 10
Fig. 13
Fig. 12
4. Assemble the remaining drum supports (F) Fig. 9, to base (A) as shown.
5. Assemble “U” bracket (H) Fig. 10, to drum (J). Place a 5/16" flat washer then a 5/16" lockwasher onto a 5/16­18x5/8" hex head screw. Insert the hex head screw (K) thru the hole in the “U” bracket and the hole in the drum, thread a 5/16" hex nut onto the hex head screw and tighten securely. Repeat this process for the remaining hole. NOTE: “U” bracket should be mounted to the right side of opening (L) in drum as shown.
6. Align the holes in the drum support (M) Fig. 12, with the holes in the drum (J). Place a 5/16" flat washer on a 5/16-18x5/8" hex head screw, then 5/16" lockwasher onto the hex head screw, insert the hex head screw thru the hole in drum support and drum. Thread a 5/16" hex nut onto the hex head screw and tighten securely. Fasten the remaining drum supports to the drum (J) in the same manner.
7. The dust collector is supplied with two 6" hose clamps (P) Fig. 13. Place one end of 6" dia. flexible hose (R) over blower/motor inlet (B) Fig. 14, and secure with hose clamp (P).
8. Place the other 6" hose clamp on flexible hose and attach the other end of the hose to drum (J) Fig. 14 in the same manner.
Fig. 14
F
A
J
H
K
L
J
M
M
P
R
P
J
R
P
B
F
Page 7
7
Fig. 15
Fig. 16
Fig. 17
9. Attach the lower dust bag retaining clip (A) Fig. 14A, to the dust collector drum. Align the two holes (B) in the retaining clip (A) Fig. 14A, with the two holes in the drum. Insert a 1/4-20x5/8" hex head screw through the holes in the retaining clip and the holes in the drum. Place a 1/4" flat washer onto the screws, and thread 1/4-20 hex nut s on the screws and tighten securely. Repeat this process for the three remaining sides of the drum.
ASSEMBLING DUST INTAKE PORT AND CAPS TO BLOWER AND MOTOR ASSEMBLY
1. MAKE CERTAIN THE DUST COLLECTOR IS DISCONNECTED FROM THE POWER SOURCE.
2. Align the four holes in dust intake port (A) Fig. 15, with the mounting holes in flange (B) of blower and motor assembly and fasten with four sheet metal screws (C). Fig. 16 illustrates the dust intake port assembled to the blower assembly.
3. NOTE: Two dust intake port caps (D) Fig. 17, are supplied with the dust collector. The caps are to be placed into the dust intake ports (E) when the intake ports are not in use.
4. Place the collar of dust cap (D) Fig. 17, over the opening on intake port. Press recessed side of dust cap (D) into port opening. IMPORTANT: When connecting an intake hose to one or both intake ports, DO NOT
REMOVE THE DUST CAP COLLARS (F) FIG. 17 FROM THE INTAKE PORTS. Pull the dust cap from the port
opening and slide the collar and cap farther onto the port housing.
A
B
C
E
D
E
D
F
Fig. 14A
A
B
Page 8
8
Fig. 18
Fig. 19
Fig. 22
Fig. 20
Fig. 21
ASSEMBLING FILTER AND DUST COLLECTION BAGS TO DRUM
1. Hook the loop on the top of filter bag (A) Fig. 18, onto filter bag support rod (B) as shown.
2. Assemble extension rod (C) Fig. 19, onto the end of filter bag support rod (B). Raise support rods (B) and (C), with filter bag (A) attached and place end of support rod (C) into holes of bracket (D). NOTE: Flared end of filter bag extension rod will prevent the rod from sliding through bracket.
3. Position open end of filter bag (A) Fig. 19, over lip of dust drum (E). Insert locking band (F) Fig. 20, through the loops of filter bag (A) and fasten with clamp (G) as shown in Fig. 21. NOTE: Make certain locking band is positioned in the channel of drum (F) before fastening clamp.
4. Pull up on each retaining clip (A) Fig. 22, and insert the dust collection bag (B) underneath each retaining clip to hold the dust collection bag in place.
5. Place the locking clamp (C) Fig. 22 around dust collection bag and dust collector drum and lock in place.
NOTE: Make certain locking clamp is positioned in the channel of the dust collector drum before locking clamp.
A
B
B
A
E
C
D
G
A
E
F
G
E
A
B
C
Page 9
9
Fig. 23
ASSEMBLING DUST INTAKE HOSES TO BLOWER AND MOTOR ASSEMBLY
KEEP DUST CAPS INSTALLED AT ALL TIMES OVER INTAKE PORTS. REMOVE A DUST CAP ONLY WHEN A FLEXIBLE HOSE IS ATTACHED TO THE INTAKE PORT.
The dust collector is supplied with a 4" dia. flexible dust intake hose.
1. To assemble the intake hose (A) Fig. 23, to the blower assembly, pull the dust cap (B) from the dust intake port (C) and slide the dust cap collar (D) farther onto the dust intake port (C) as shown. IMPORTANT: DO NOT RE-
MOVE THE INTAKE CAP FROM THE INTAKE PORT.
2. Place hose clamp (E) Fig. 23, on one end of flexible hose (A) and assemble the hose to dust intake port (C). Tighten hose clamp (E). Should you wish to operate your dust collector with a second intake hose, contact your local Delta Distributor to
purchase the hose and install as in STEPS 1 and 2 above. Whenever one of the dust intake ports is not in use, always be sure the dust cap is properly installed in the intake port for operator safety.
ALWAYS DISCONNECT DUST COLLECTOR FROM THE POWER SOURCE BEFORE CONNECTING OR DISCONNECTING INTAKE HOSE.
CONNECTING TOOL TO POWER SOURCE
POWER CONNECTIONS
A separate electrical circuit should be used for your tools. This circuit should not be less than #12 wire and should be protected with a 20 Amp time lag fuse. Have a qualified electrician repair or replace damaged or worn cord immediately. Before connecting the motor to the power line, make certain the switch is in the “OFF” position and be sure that the electric current is of the same characteristics as stamped on the motor nameplate. All line connections should make good contact. Running on low voltage will damage the motor.
WARNING: DO NOT EXPOSE THE DUST COLLECTOR TO RAIN OR OPERATE THE MACHINE IN DAMP
LOCATIONS.
MOTOR SPECIFICATIONS
Your tool is wired for 120 volt, 60 HZ alternating current. Before connecting the tool to the power source, make sure the switch is in the “OFF” position.
GROUNDING INSTRUCTIONS
WARNING: THIS TOOL MUST BE GROUNDED WHILE IN USE TO PROTECT THE OPERATOR FROM ELECTRIC SHOCK.
This tool must be grounded. If it should malfunction or break down, grounding provides a path of least resistance for electric current to reduce the risk of electric shock. This tool is equipped with a cord having an equipment-grounding conductor and grounding plug. The plug must be inserted into an appropriate outlet that is properly installed and grounded in accordance with all local codes and ordinances.
WARNING: Improper connection of the equipment-grounding conductor can result in a risk of electric
shock. Check with a qualified electrician or service person if you are in doubt as to whether the outlet is properly grounded. Do not modify the plug provided with the dust collector. If it will not fit the outlet, have a proper outlet installed by a qualified electrician.
120 VOLT, SINGLE PHASE OPERATION
This tool must be grounded while in use to protect the operator from electric shock. The motor recommended for use with your dust collector is shipped wired for 120 Volt, Single Phase, and is equipped with an approved 3-conductor cord and 3-prong grounding type plug to fit the proper grounding type receptacle, as shown in Fig. 24. The green conductor in the cord is the grounding wire. Never connect the green wire to a live terminal. A temporary adapter, shown in Fig. 25, is available for connecting 3-prong grounding type plugs to 2-prong receptacles if a properly grounded outlet is not available. The temporary adapter should be used only until a properly grounded outlet can be installed by a qualified electrician. THIS ADAPTER IS NOT APPLICABLE IN CANADA. The green­colored rigid ear, lug, etc., extending from the adapter, is the grounding means and must be connected to a permanent ground such as to a properly grounded outlet box, as shown in Fig. 25. Whenever the adapter is used, it must be held in place with a metal screw.
A
B
E
D
C
Page 10
10
Use proper extension cords. Make sure your extension cord is in good condition and is a 3-wire extension cord which has a 3-prong grounding type plug and a 3-hole receptacle which will accept the tool’s plug. When using an extension cord, be sure to use one heavy enough to carry the current of the tool. An undersized cord will cause a drop in line voltage, resulting in loss of power and overheating. Figs. 27 & 27A, shows the correct gauge to use depending on the cord length. If in doubt, use the next heavier gauge. The smaller the gauge number, the heavier the cord.
EXTENSION CORDS
Fig. 24
GROUNDED OUTLET BOX
CURRENT
CARRYING
PRONGS
GROUNDING BLADE IS LONGEST OF THE 3 BLADES
HOLES
Fig. 25
GROUNDED OUTLET BOX
GROUNDING
MEANS
ADAPTER
HOLES
GROUNDED OUTLET BOX
CURRENT CARRYING PRONGS
GROUNDING BLADE IS LONGEST OF THE 3 BLADES
Fig. 26
240 volt
240 VOLT, SINGLE PHASE OPERATION
The motor supplied with your tool is a dual voltage 120/240 volt motor. If it is desired to operate your dust collector at 240 volts, single phase, contact your local Authorized Delta Service Center or qualified electrician for proper procedures to rewire your dust collector motor for 240 volt operation and wiring a 240 volt attachment plug to the power supply cord. The tool with a 240 volt plug should only be connected to an outlet having the same configuration as the plug illustrated in Fig. 26. No adapter is available or should be used with the 240 volt plug.
AS A PRECAUTION IN ALL CASES, MAKE CERTAIN THE RECEPTACLE IN QUESTION IS PROPERLY GROUNDED. IF YOU ARE NOT SURE, HAVE A QUALIFIED ELECTRICIAN CHECK THE RECEPTACLE.
Fig. 27
MINIMUM GAUGE EXTENSION CORD
RECOMMENDED SIZES FOR USE WITH STATIONARY ELECTRIC TOOLS
Ampere Volts Total Length of Gauge of
Rating Cord in Feet Extension Cord
0-6 120 up to 25 18 AWG 0-6 120 25-50 16 AWG 0-6 120 50-100 16 AWG 0-6 120 100-150 14 AWG 6-10 120 up to 25 18 AWG 6-10 120 25-50 16 AWG 6-10 120 50-100 14 AWG 6-10 120 100-150 12 AWG 10-12 120 up to 25 16 AWG 10-12 120 25-50 16 AWG 10-12 120 50-100 14 AWG 10-12 120 100-150 12 AWG 12-16 120 up to 25 14 AWG 12-16 120 25-50 12 AWG 12-16 120
GREATER THAN 50 FEET NOT RECOMMENDED
MINIMUM GAUGE EXTENSION CORD
RECOMMENDED SIZES FOR USE WITH STATIONARY ELECTRIC TOOLS
Ampere Volts Total Length of Gauge of
Rating Cord in Feet Extension Cord
0-6 240 up to 50 18 AWG 0-6 240 50-100 16 AWG 0-6 240 100-200 16 AWG 0-6 240 200-300 14 AWG 6-10 240 up to 50 18 AWG 6-10 240 50-100 16 AWG 6-10 240 100-200 14 AWG 6-10 240 200-300 12 AWG 10-12 240 up to 50 16 AWG 10-12 240 50-100 16 AWG 10-12 240 100-200 14 AWG 10-12 240 200-300 12 AWG 12-16 240 up to 50 14 AWG 12-16 240 50-100 12 AWG 12-16 240
GREATER THAN 100 FEET NOT RECOMMENDED
Fig. 27A
Page 11
11
OPERATING CONTROLS
WARNING: BEFORE OPERATING THE MACHINE, FOR OPERATOR SAFETY, ALWAYS MAKE CERTAIN THAT EACH DUST INTAKE PORT (WHICH IS NOT BEING USED OR PREVIOUSLY ASSEMBLED TO A DUST COLLECTION SYSTEM) BE COVERED WITH A DUST INTAKE PORT CAP. THE ROTATING FAN INSIDE THE BLOWER HOUSING IS ACCESSIBLE THROUGH THE DUST INTAKE PORTS AND IS HAZARDOUS. ALWAYS WEAR PROPER APPAREL, DO NOT WEAR JEWELRY, AND KEEP FINGERS AND ALL FOREIGN OBJECTS OUT OF THE DUST INTAKE PORTS. FOLLOW THE SAFETY RULES STATED EARLIER ON PAGES 3 AND 4 IN THIS MANUAL.
Fig. 28
Fig. 29
ON/OFF SWITCH
The “on/off” switch is located on the side of the motor. To turn the dust collector “ON”, push the start button (A) Fig. 28. To turn the dust collector “OFF”, push stop button (B).
LOCKING SWITCH IN THE “OFF” POSITION
IMPORTANT: When the machine is not in use, the switch
(A) Fig.18 should be locked in the OFF position using a padlock (C), with a 3/16" diameter shackle to prevent unauthorized use.
CIRCUIT BREAKER
Your dust collector motor is supplied with a resettable circuit breaker. If the motor shuts off or fails to start due to an overload condition, turn the dust collector switch “OFF,” let the motor cool three to five minutes, and push the reset button (D) Fig. 29, on the circuit breaker to reset the breaker. The motor can then be turned on again in the usual manner. If the overload continues to trip, take the dust collector to a Delta Authorized Service Center for repair.
MAINTENANCE
NOTE: Before any maintenance or service is performed, be sure the unit is disconnected from the power source to
prevent starting. All servicing other than the items recommended in this Instruction Manual should be performed by an authorized service facility. When storing your dust collector, remove power supply cord from the electrical outlet. Coil the cord neatly and place it off the floor on the base of the dust collector to eliminate potential cord damage.
MOTOR MAINTENANCE
Removing dust and dirt: Blow off motor with low pressure air to remove dust or dirt. Air pressure above 50 P.S.I. should not be used as high pressure may damage insulation and blow dirt under loosened tape. The operator performing this cleaning function should always wear eye protective goggles. Dust can cause excessive insulation temperatures.
A
B
A
C
D
Page 12
12
Two Year Limited Warranty
Delta will repair or replace, at its expense and at its option, any Delta machine, machine part, or machine accessory which in normal use has proven to be defective in workmanship or material, provided that the customer returns the product prepaid to a Delta factory service center or authorized service station with proof of purchase of the product within two years and provides Delta with reasonable opportunity to verify the alleged defect by inspection. Delta may require that electric motors be returned prepaid to a motor manufacturer’s authorized station for inspection and repair or replacement. Delta will not be responsible for any asserted defect which has resulted from normal wear, misuse, abuse or repair or alteration made or specifically authorized by anyone other than an authorized Delta service facility or representative. Under no circumstances will Delta be liable for incidental or consequential damages resulting from defective products. This warranty is Delta’s sole warranty and sets forth the customer’s exclusive remedy, with respect to defective products; all other warranties, express or implied, whether of merchantability, fitness for purpose, or otherwise, are expressly disclaimed by Delta.
Printed in U.S.A.
PARTS, SERVICE OR WARRANTY ASSISTANCE
All Delta Machines and accessories are manufactured to high quality standards and are serviced by a network of Porter-Cable Delta Factory Service Centers and Delta Authorized Service Stations. To obtain additional information regarding your Delta quality product or to obtain parts, service, warranty assistance, or the location of the nearest service outlet, please call 1-800-223-7278 (In Canada call 1-800-463-3582).
ACCESSORIES
A complete line of accessories is available from your Delta Supplier, Porter-Cable Delta Factory Service Centers, and Delta Authorized Service Stations. Please visit our Web Site
www.deltamachinery.com for a catalog or
for the name of your nearest supplier.
WARNING: Since accessories, other than those offered by Delta, have not been tested
with this product, use of such accessories could be hazardous. For
safest operation, only
Delta recommended accessories should be used with this product.
Page 13
The following are trademarks of PORTER-CABLE·DELTA (Las siguientes son marcas registradas de PORTER-CABLE S.A.): Auto-Set®, BAMMER®, B.O.S.S.®, Builder’s Saw®, Contractor’s Saw®, Contractor’s Saw II™, Delta®, DELTACRAFT®, DELTAGRAM™, Delta Series 2000™, DURATRONIC™, Emc²™, FLEX®, Flying Chips™, FRAME SAW®, Homecraft®, INNOVATION THAT WORKS®, Jet-Lock®, JETSTREAM®, ‘kickstand®, LASERLOC®, MICRO-SET®, Micro-Set®, Midi Lathe™, MORTEN™, NETWORK™, OMNIJIG®, POCKET CUTTER®, PORTA-BAND®, PORTA-PLANE®, PORTER-CABLE®&(design), PORTER-CABLE®PROFESSIONAL POWER TOOLS, Posi-Matic®, Q-3®&(design), QUICKSAND®&(design), QUICKSET™, QUICKSET II®, QUICKSET PLUS™, RIPTIDE™&(design), SAFE GUARD II®, SAFE­LOC®, Sanding Center®, SANDTRAP®&(design), SAW BOSS®, Sawbuck™, Sidekick®, SPEED-BLOC®, SPEEDMATIC®, SPEEDTRONIC®, STAIR EASE®, The American Woodshop®&(design), The Lumber Company®&(design), THE PROFESSIONAL EDGE®, THE PROFESSIONAL SELECT®, THIN-LINE™, TIGER®, TIGER CUB®, TIGER SAW®, TORQBUSTER®, TORQ-BUSTER®, TRU-MATCH™, TWIN-LITE®, UNIGUARD®, Unifence®, UNIFEEDER™, Unihead®, Uniplane™, Unirip®, Unisaw®, Univise®, Versa-Feeder®, VERSA-PLANE®, WHISPER SERIES®, WOODWORKER’S CHOICE™.
Trademarks noted with ™ and ® are registered in the United States Patent and Trademark Office and may also be registered in other countries. Las Marcas Registradas con el signo de ™ y ® son registradas por la Oficina de Registros y Patentes de los Estados Unidos y también pueden estar registradas en otros países.
PORTER-CABLE DELTA SERVICE CENTERS
(CENTROS DE SERVICIO DE PORTER-CABLE
DELTA)
Parts and Repair Service for Porter-Cable •Delta Machinery are Available at These Locations
(Obtenga Refaccion de Partes o Servicio para su Herramienta en los Siguientes Centros de Porter-Cable
Delta)
Authorized Service Stations are located in many large cities. Telephone 800-438-2486 or 731-541-6042 for assistance locating one. Parts and accessories for Porter-Cable
·
Delta products should be obtained by contacting any Porter-Cable·Delta Distributor, Authorized
Service Center, or Porter-Cable
·
Delta Factory Service Center. If you do not have access to any of these, call 800-223-7278 and you will
be directed to the nearest Porter-Cable·Delta Factory Service Center. Las Estaciones de Servicio Autorizadas están ubicadas en muchas grandes ciudades. Llame al 800-438-2486 ó al 731-541-6042 para obtener asistencia a fin de localizar una. Las piezas y los accesorios para los productos Porter-Cable
·
Delta deben obtenerse poniéndose en contacto con cualquier distribuidor Porter-Cable·Delta, Centro
de Servicio Autorizado o Centro de Servicio de Fábrica Porter-Cable·Delta. Si no tiene acceso a ninguna de estas opciones, llame al 800-223-7278 y le dirigirán al Centro de Servicio de Fábrica Porter-Cable
·
Delta más cercano.
ARIZONA
Tempe 85282 (Phoenix) 2400 West Southern Avenue Suite 105 Phone: (602) 437-1200 Fax: (602) 437-2200
CALIFORNIA
Ontario 91761 (Los Angeles) 3949A East Guasti Road Phone: (909) 390-5555 Fax: (909) 390-5554
San Leandro 94577 (Oakland) 3039 Teagarden Street Phone: (510) 357-9762 Fax: (510) 357-7939
COLORADO
Arvada 80003 (Denver) 8175 Sheridan Blvd., Unit S Phone: (303) 487-1809 Fax: (303) 487-1868
FLORIDA
Davie 33314 (Miami) 4343 South State Rd. 7 (441) Unit #107 Phone: (954) 321-6635 Fax: (954) 321-6638
Tampa 33609 4538 W. Kennedy Boulevard Phone: (813) 877-9585 Fax: (813) 289-7948
GEORGIA
Forest Park 30297 (Atlanta) 5442 Frontage Road, Suite 112 Phone: (404) 608-0006 Fax: (404) 608-1123
ILLINOIS
Addison 60101 (Chicago) 400 South Rohlwing Rd. Phone: (630) 424-8805 Fax: (630) 424-8895
Woodridge 60517 (Chicago) 2033 West 75th Street Phone: (630) 910-9200 Fax: (630) 910-0360
MARYLAND
Elkridge 21075 (Baltimore) 7397-102 Washington Blvd. Phone: (410) 799-9394 Fax: (410) 799-9398
MASSACHUSETTS
Braintree 02185 (Boston) 719 Granite Street Phone: (781) 848-9810 Fax: (781) 848-6759
Franklin 02038 (Boston) Franklin Industrial Park 101E Constitution Blvd. Phone: (508) 520-8802 Fax: (508) 528-8089
MICHIGAN
Madison Heights 48071 (Detroit) 30475 Stephenson Highway Phone: (248) 597-5000 Fax: (248) 597-5004
MINNESOTA
Minneapolis 55429 5522 Lakeland Avenue North Phone: (763) 561-9080 Fax: (763) 561-0653
MISSOURI
North Kansas City 64116 1141 Swift Avenue P.O. Box 12393 Phone: (816) 221-2070 Fax: (816) 221-2897
St. Louis 63119 7574 Watson Road Phone: (314) 968-8950 Fax: (314) 968-2790
NEW YORK
Flushing 11365-1595 (N.Y.C.) 175-25 Horace Harding Expwy. Phone: (718) 225-2040 Fax: (718) 423-9619
NORTH CAROLINA
Charlotte 28270 9129 Monroe Road, Suite 115 Phone: (704) 841-1176 Fax: (704) 708-4625
OHIO
Columbus 43214 4560 Indianola Avenue Phone: (614) 263-0929 Fax: (614) 263-1238
Cleveland 44125 8001 Sweet Valley Drive Unit #19 Phone: (216) 447-9030 Fax: (216) 447-3097
OREGON
Portland 97230 4916 NE 122 nd Ave.
Phone: (503) 252-0107 Fax: (503) 252-2123
PENNSYLVANIA
Willow Grove 19090 520 North York Road Phone: (215) 658-1430 Fax: (215) 658-1433
TEXAS
Carrollton 75006 (Dallas) 1300 Interstate 35 N, Suite 112 Phone: (972) 446-2996 Fax: (972) 446-8157
Houston 77055 West 10 Business Center 1008 Wirt Road, Suite 120 Phone: (713) 682-0334 Fax: (713) 682-4867
WASHINGTON
Auburn 98001(Seattle) 3320 West Valley HWY, North Building D, Suite 111 Phone: (253) 333-8353 Fax: (253) 333-9613
Printed in U.S.A.
CANADIAN PORTER-CABLE DELTA SERVICE CENTERS
ALBERTA
Bay 6, 2520-23rd St. N.E. Calgary, Alberta T2E 8L2 Phone: (403) 735-6166 Fax: (403) 735-6144
BRITISH COLUMBIA
8520 Baxter Place Burnaby, B.C. V5A 4T8 Phone: (604) 420-0102 Fax: (604) 420-3522
MANITOBA
1699 Dublin Avenue Winnipeg, Manitoba R3H 0H2 Phone: (204) 633-9259 Fax: (204) 632-1976
ONTARIO
505 Southgate Drive Guelph, Ontario N1H 6M7 Phone: (519) 836-2840 Fax: (519) 767-4131
QUÉBEC
1515 ave. St-Jean Baptiste, Québec, Québec G2E 5E2 Phone: (418) 877-7112 Fax: (418) 877-7123
1447, Begin St-Laurent, (Montréal), Québec H4R 1V8 Phone: (514) 336-8772 Fax: (514) 336-3505
Loading...