Delta 257 TYBOX Installation

Page 1
~1,50 m
Mini 20 cm
A
B
2
2
3
4
5
B
1
A
1
4
5
TYBOX
157
x 1
x 7
5 + 2
TYBOX
257
A
B
A B
*2703461_Rev.2en*
TYBOX 157 - 257
2 x 1,5V LR03 - AAA Alkaline
868 MHz (EN 300 220)
100 m
8 max.
/
°C -5°C / +40°C
80 x 103 x 25 mm
R&TTE 1999/5/CE
www.deltadore.com
Important product information (➋➍)
Press time
Association
Slow flashing
LED off
Room temperature
Set-point temperature
Daily programming
Weekly programming
2 daily programs (week + week-end)
> 5s
PROG
x1
PROG
x7
... ... ...
OFF
PROG
5+2
Operate the switch to select
the type of programming
Page 2
>10s
... ... ...
NO
NC
230V~
50Hz
N
N
OR
L
< 3000 W
> 3000 W
or
RF 640
RF 642
Th
Thermostat input
Blue
Brown
Black
Grey
1
31
1
12
0
23
0
59
2012 ...
EXIT
You can change the direction of operation of the relay
NO : Normally Open
NC : Normally Closed
Electrical heating control (contact switch if P>3000W)
Press + or - to select the day, then press OK to confirm and move on to the next setting
Turn the selector dial to . The days flash.
Repeat the process to set the hours and minutes.To exit the "time setting" mode, turn the selector dial.
Circulator control for the
boiler
Input control
for boiler thermostat
Page 3
OK
2
1
5
4
3
6
10
9
... ... ...
OFF
> 3s
>5s
EXIT
1
0
7
8
OK
8
9
OFF
EXIT
OR
RF 642
RF 640
7
No
Ye s
On the receiver, press the button for 3 seconds until the LED flashes. Release
Turn the selector dial to . Press the button i for 5 se-
conds.
Press the R button, then fill in menu R-01
Rad menu
press OK
Rad menu 1
press i
To exit the mode,
turn the selector
The receiver LED is no longer flashing. The receiver is associated with the transmitter
The receiver LED is no longer flashing. The receiver is associated with the transmitter
To exit the mode, turn the se­lector dial.
Rad menu
press i
If "1" is displayed, the product has been associated.
1
2 3
4
Do you have one or more home automation radio products in your system? (e.g. Opening detector)
>5s
0
2
0
1
EXIT
MENU 1
Tybox 157 Tybox 257
X
Comfort regulated by TYBOX
Comfort temperature set on each radiator or convector
Tybox 157 Tybox 257
X X
Anti-seizing off
Anti-seizing on (circulator pump ON: 1 minute / 24h)
Length of a programme stage
60', 30', 15'
Tybox 157 Tybox 257
X
60 min.
30 min.
15 min.
RF 642 : 0 RF 640 : 0/1
Press button 1,
To change the different settings, press the + or - buttons, then press the OK button to confirm and move on to the next setting.
Turn the selector dial to , then press
i for 5 seconds
To exit the mode, turn the selector dial to another mode.
For electrical or hot-water heating systems with thermostatic valves, the thermostat for each radiator or convector may be adjusted to give a comfortable temperature. In this case, the TYBOX only regulates the Economy and Frost-Protection temperatures.
Page 4
>5s
1
0
EXIT
1
2
3
4
5
1
0
MENU 2
: 5°C --> 30°C
19°C
: 5°C --> 30°C
16°C
0,2°C < < 2°C
Hysteresi
s
0,4°C
Permission to change
Programme and settings
0 : Modifications permitted to programme and settings
1 : Modifications to programme not permitted and adjustment of settings limited
+/- 3°C either side of the last setting.
Tybox 157 Tybox 257
X X
: 5°C < < 30°C
: 5°C < < 16°C
16°C < < 22°C
13°C < < 19°C
5°C < < 11°C
+/- 3°C
PROG
Temperature displayed in AUTO mode
0 : Continuous display of the temperature setting. In this case, press the i button to display the room temperature
1 : Continuous display of the room temperature. In this case, press the i button to display the temperature setting.
Tybox 157 Tybox 257
X
Control time base
If you choose an "on/off" type setting, you can adjust the hysteresis (or differential) via menu 2-11
Minutes
Minutes
Minutes
Minutes
On/Off
Automatic time change (summer/winter time)
Tybox 157
Tybox 257
X
X
Time display mode 12h-24h
Tybox 157 Tybox 257
X X
24 h
12 h
Measured temperature correction (-5°C à +5°C par pas de 0,1°C).
Example: If the temperature displayed on the device is 19°C and the observed temperature is 20°C, adjust the temperature by +1°C, then confirm by pressing OK.
Tybox 157 Tybox 257
X X
- 5°C < < +5°C
Before changing this setting, the device must have been in operation for at least 2 hours.
Inter val before maintenance of the boiler(réglable de 0 à 365 jours).
Reprogramme after each maintenance operation
--- (0) to 365 days
Temperature settings controlled by the transmitter
Reset operating counter hours of the boiler
Tybox
157
Tybox
257
X X
No
Yes
Press button 2.
To change the different settings, press the + or - buttons, then press the OK button to confirm and move on to the next setting.
Turn the selector dial to , then press the i button for 5 seconds.
Presence of transmitter
Tybox 157 Tybox 257
X
No
Yes
Page 5
>5s
EXIT
OR
OR
1
2
3
4
4
4
3
3
3s 7s
20s
... ... ...
RESET OK
>30s
.. .. ..... .. ..
>5s
OR
OR
Init
Menu 1
Init
Menu 2
Init RF
RESET
1
3
4
2
Alkalines 1,5V
LR03 (AAA)
You have approximately 30 seconds to change the batteries before the time setting is reset (if this happens, reprogramme the date and time).
When the batteries symbol appears. you have approximately 1 month to change the batteries (2 1.5 V LR03 or AAA alkaline batteries).
The factory settings may be restored for each of the menus.
Turn the selector dial to , then press the i button for 5 seconds.
Press the button for 5 seconds on the menu you wish to reset.
Press OK to confirm the reset.
Resetting the receiver. Press and hold for 30 seconds until the LED flashes rapidly.