A
ll
A
ll
Shutter 2
Shutter 2
M
A
C
:
0
0
1
A
2
5
F
F
F
F
1
2
3
4
5
6
?
i
1
2
3
*
OFF
60 %
80 %
0 %
80 %
0 %
18.5 °C
OFF
A B
ADSL BOX
ADSL BOX
1
2
3
A
DSL BOX
1
1
2
Ethernet cable
Ethernet cable
T
YDOM 1000
T
YDOM 2000
Back
Control of
all shutters
in the group
Shutter
control 1
Shutter
control 2
Configuration
Raise
Lower
Current
status
Ethernet
cable
TYDOM 1000
1
Shutters
Alarm
Others
Lighting
Garage
Scenarios
Heating
Gate
Rooms
?
L
og in
_
a
bc def ghi jkl
m
no pqrs tuv wxyz
+
a
/A 123
?
D
EMO
Log in
123456
LEDs off
No power supply
Green LEDs
230 V power supply OK
Red LED
No Ethernet cable connected
Flashing orange LED
Awaiting IP allocation (DHCP)
LED off
IP allocated, awaiting
connection of the application
Green LED
Application connected
1
2
a
bc def ghi jkl
m
no pqrs tuv wxyz
+
a
/A 123
MAC : 001A25FFFF123456
Green LED
OK
D
EMO
Stop
Components provided
- Depending on your device: Connect to Google Play or the App Store
- Find the “iTYDOM 1000” app or “iTYDOM 2000”
- Download the application
Activate the Wi-Fi connection on the smartphone / tablet
-
ome automation gateway for smartphone and tablet application
H
TYDOM 1000
Local control
ser guide
U
TYDOM 2000
Local and remote control
Application compatible with iOS and Google play (Android)
EN
. The home page screen
1
Access to
functions
Current function status displayed.
Example:
All shutters
are open
All shutters
are closed
. The control screen
2
You can access the application’s functions
by touching the screen. Press the function
you require.
The quality of your product's connection may be adversely affected by changes to the IP
architecture on which it operates.
These changes may include, but are not limited to, changes of hardware, software
updates and configuration operations concerning your operator's equipment or any other
multimedia equipment such as tablets, smartphones, etc.
elta Dore hereby declares that the equipment
D
meets the essential requirements and complies
with the other relevant provisions of Directive
999/5/EC (R&TTE Directive) (wireless)
1
Android™ and Google Play are registered trademarks of Google Inc.
IOS™ is a registered trademark of Cisco Systems Inc.
4. Key to pictograms
Help display
Confirmation
Configuration
button
Back
(Holding the button down displays
the home page)
Previous screen
Next screen
Previous page
Next page
Information
Because of changes in standards and equipment,
a
he characteristics given in the text
t
nd the illustrations in this document are not
binding unless confirmed
*2703392_Rev.2*
www.deltadore.com
Swipe your finger up or
down to increase or
decrease
Pulse control
Command executed
correctly
Fault warning
Open entry
3. The functions of the application
onfiguration Functions
C
ettings
S
Available for access
levels 2 and 3. (*)
To get the most out of your application
Scenarios: Combine actions selected for different functions:
Roller shutters, lighting, etc. (away scenario: Shutters closed, lights off.
Arrival scenario: shutters open)
Management of controls by room: Group together controls for the same room.
(example: Lounge - 3 lights - 2 roller shutters).
Management of controls by group: Group together controls with the same functions. (e.g.
all roller shutters on the ground floor).
3 locking levels to protect your configuration (
Changes not allowed
Customisation of the buttons, scenarios and rooms
Addition and deletion of RF products possible
* Installer access code required
oller
R
hutters
s
The various functions of the application enable you to:
• Create control groups,
• Add and delete products (access level 3).
N.B.: Locking levels 1 and 2 only display the configured icons.
ighting Garage Gate Other
L
*
)
eating
H
nd
a
Cooling
A
larm
ses
u
5. Applications
Group
Total
Arrival
South-facing
shutter group
Bedroom
Paul
18.5°C
ON OFF
Choose
number
Choose
wording
1
2
3
4
5
6
7
C
opy
Replace
T
YDOM
S
ave
Y
es
No
Yes No
Yes No
P2
P3
P4
P1
Yes
No
A
ccess level
I
nstaller
a
ccess code
Rooms
Settings
A
dvanced
s
ettings
S
oftware
v
ersions
P
arameters
R
egional
p
arameters
Language
N
ame
S
elect
products
Name
N
ame
C
hoose a
p
ictogram
Choose a
pictogram
S
elect
p
roducts
S
elect
s
tates
A
dd products
D
elete
p
roducts
D
elete
a
ll products
D
elete the
g
roup
Lock
N
etworks
m
aintenance
D
ata
t
ransfer
A
larm initialisation
Application initialisation
TYDOM initialisation
I
nitialisation
Manage the list
of product
N
ame
Choose a
pictogram
Modify states
D
elete
t
he scenario
N
ame
C
hoose a
p
ictogram
Add a
detector
Name
List of
detectors
Name
Choose a
pictogram
Select
products
Delete the room
N
ame
Choose a
pictogram
Delete
all products
Delete
a product
Add
products
Pre-defined
wording
Customised
wording
1
*
* * *
User
access codes
Status of functions
o
n the homepage
*
* * *
2 3
1
32 4
1
1
16
1
4
3
2
1
2
3
Choose a
pictogram
Locate
A
ssociation mode
?
1
2 3 4
* * * *
NEW NEW X2
* * * *
1
7 32
12
5
1
2
3
1 2 3 4
OK
OFF
OFF
O
FF
O
FF
>
3"
1 2
... ... ...
230V~
5
0/60 Hz
O
N
1
2
3
4
OFF
Bip
ONO
FF
21
i
N
ew group
G
roup total
G
roup 1
P
oint 2
Scenarios
N
ew scenario
Scenario 1
New room
Room 1
OFF
M
anage the
p
roducts
G
roup total
Point
Manage
the partials
Warning device
test
Download
*
*
*
*
Choose an element from the list or press the associated product's test button.
Alarm
O
FF
1
OFF
ON
1
Alarm
On
Off
Partial
Configuration
Open entry
Alarm status
Monitoring in progress
Shutdown surveillance
Partial operating modes
Fault
warning
Back
Information
A
ctivated
Deactivated
AC
Off
Heating
Heating
General
Day zone
Configuration
Air conditioning
mode
General control
Day zone control
Heating Mode
Back
Off mode
S
ave function
The button
allows you to memorise your settings
and customisation.
S
ave
C
opy function
The button
allows you to duplicate your settings
on other smartphones and tablets.
C
opy
M
anage the list
o
f product
Manage the list
of product
Remote access
P
assword
Connection
*
* * *
O
verall heat
Yes
No
Start
Name
Locate
Access code
After configuration is complete, it is a good idea to customise your installer access code.
installer
(Default)
Menu
“Add
a product”
Advanced
settings
Lock
Protect your configuration by choosing an appropriate access level (level 1 or 2 recommended)
Installer
access code
(Default)
Advanced
settings
Lock Access level
Choose a pictogram
Continue
No changes are allowed during use (1)
Customisation of the buttons, scenarios and rooms (1)
Addition and deletion of RF products possible
Alarm
(1): Locking levels 1 and 2 only
display the configured
icons.
Remote connection assistant (only for TYDOM 2000)
You can visit the help section for the displayed page at any time by pressing this symbol.
7. Block diagram
Advanced
settings
Connection Remote access
Fixed IP address
ADSL box settings
Connection test (2)
(2) : If the connection fails, a
troubleshooting page is
displayed.
The Alarm function control screen
The Heating and Cooling function control screen
3 types of control depending on your installation
Adjustment by setting
Adjustment by mode On-Off selection
°C
Economy
Setting Pilot wire On-Off
Off