DEL Ozone ECT-2, ECT-4 Operation Manual

0 (0)
DEL Ozone ECT-2, ECT-4 Operation Manual

Corona Discharge Ozone Generators

TOTAL

For Models ECT-2 and ECT-4

 

Installation & Operation Manual

DEL Ozone · SAN LUIS OBISPO, CA 93401 · USA · 800-676-1335 · Fax: 805-541-8459

011005 / 4-0026 Rev B.

Total Eclipse Corona Discharge Ozone Generator

Table of Contents

SECTION 1

 

General Information

 

1A

Description.........................................................................

1

1B

Specifications....................................................................

1

SECTION 2

 

Installation & Operation

 

2A

Installation.........................................................................

1

2B

Operation............................................................................

4

2C

Maintenance......................................................................

5

 

2C-1

Ozone Module Replacement................................

5

 

2C-2

Ozone Air Filter Replacement..............................

5

 

2C-3

Winterizing the Total Eclipse................................

5

SECTION 3

 

 

Troubleshooting........................................................

5-6

SECTION 4

 

 

Replacement Parts and Ordering

 

Information

 

 

5A Ordering Information........................................................

6

5B Standard Replacement Parts List..................................

6

Warranty.....................................................................

 

6

 

All Eclipse CD Ozone Generators

 

C

are UL Classified.

 

IMPORTANT SAFETY INSTRUCTIONS

Read and Follow All Instructions

Read this manual completely before attempting installation.

All permanent electrical connections should be made by a qualified electrician.

For cord and plug-connected units, connect to a grounded, grounding type receptacle only. If the Total Eclipse™ electrical connection is to be attached to the pool controls, be sure the pool controls are protected by a Ground Fault Circuit Interrupter (G.F.C.I.). If the Total Eclipse™ is connected to an independent electrical supply, then a G.F.C.I. must be installed between the Total Eclipse™ and the electrical supply.

Do not bury cord.

Warning - To reduce the risk of electrical shock, replace damaged cord immediately.

A pressure wire connector is provided on the outside of the unit to permit connection to a minimum No. 8 AWG (8.4 mm2) solid bonding conductor between this point and any grounded metal equipment, grounded metal enclosures of electrical equipment, metal water pipes, or conduit within five (5) feet (1.5m) of the unit as needed to comply with local requirements.

Install at least 5 feet (1.5 meters) from wall of pool water using nonmetallic tubing. It is highly recommended that the ozone generator be installed at least one (1) foot above the water level to prevent water from contacting electrical equipment. Install in accordance with the installation instructions.

Follow all applicable electrical codes.

Electric shock hazard. Be sure to turn power OFF and disconnect from power source before any service work is performed. Failure to do so could result in serious injury or death.

The Total Eclipse™ must be installed in an outdoor location, or indoors in a forced air ventilated room, and installed so that the orientation is exactly as shown in Figure 1. Install to provide water drainage of generator to protect electrical components.

Mount the Total Eclipse™ so that it is inaccessible to anyone in the pool. Never attempt any servicing if the unit is wet.

Plastic ozone supply tubing is inside the Total Eclipse™. Never replace this tubing with metal tubing.

Warning - Short-term inhalation of high concentrations of ozone and long term inhalation of low concentrations of ozone can cause serious harmful physiological effects. DO NOT inhale ozone gas produced by this device.

For your safety, do not store or use gasoline, chemicals or other flammable liquids or vapors near this or any other appliance.

SAVE THESE INSTRUCTIONS!

SECTION 1 General Information

1A Description

The Total Eclipse is designed to recirculate pool water while injecting ozone 24 hours a day. With the Total Eclipse you will maximize your ozone effectiveness while minimizing your operating costs.

1B Specifications

Wall Mount - 17” tall x 14” wide x 7” deep

Corona Discharge (CD) Technology

0.5 gr/hr (ECT-2) / 1.0 gr/hr (ECT-4) ozone output applied to 5 gpm nominal

24 hour operation independent of pool equipment

120V · 50/60Hz · 192W

240V · 50/60Hz · 192W

Built-in 1/20 hp recirculation pump, 5 gpm, 20 psi max

Complete with internal injector

Inline flow switch and check valve for protection of pump and CD modules

2A Installation

The most common pool and pool/spa configurations are discussedinthismanual.Foradditionalinstallationoptions or questions on your specific installation, please contact DEL Ozone at 805-541-1601, extension 249.

1.TheTotalEclipsemustbeconnectedtoaG.F.C.I.protected 120V/240V outlet providing continuous power.

2.Mount the Total Eclipse in a clean, protected area.

a.InstalltheTotalEclipseatleastone(1)footabovewater level, and no higher than eight feet above the pool’s main pump.

b.Insomeinstallations,thetopoftheTotalEclipsecabinet canbemountedupto36inchesbelowthesurfaceofthe water. If installed below the surface of the water, isolation valves must be provided as a safeguard in case of prolongedlossofpowerwherewaterseepagepastcheck valves can occur.

NOTE:Exceedingtherecommendedelevationsmayaffect the water circulation rate (i.e. Total GPM/ozone delivery).

c.Even though the Total Eclipse is designed for outdoor use, care should be taken when choosing a mounting

Total Eclipse Corona Discharge Ozone Generator

location. To protect your investment, mount the Total Eclipse where it is protected from the elements (direct sun, rain, dirt), completely sheltered if possible while providing adequate ventilation.

3.Install3/4"PVCpipingforcirculationofpoolwater,asshown in Figure 1.

a.Smaller diameter pipe will increase dynamic pressure loss, possibly causing inefficient or faulty operation of the unit.

b.Pipelargerthan3/4"maybeusedifnecessary.However, in a larger diameter pipe larger air bubbles will collect, causing gurgling at the pool. Avoid long pipe runs. Elbows, tees, and sharp bends in the piping should be avoided when possible.

c.Plumbing an independent return line from the Total Eclipse is highly recommended. Bubble formation and gurgling may occur otherwise.

NOTE:Airbubblesinthesystemcanberemovedbyinstalling a DEL MDV-20. Contact your local dealer or visit DEL’s website at www.delozone.com for details.

Foroptimumozonedistribution,theozonatedwatershould be returned back to the pool through a dedicated pipe in the bottom of the pool. If it is not possible to install with the dedicated return to the bottom of the pool, then install the Total Eclipse as shown in Figures 2, 3, or 4 based on the specific configuration of your system. These installation figures cover the following installation types: Figure 2–existingpoolswithin-floorcleaningsystem(ICS);Figure 3–existing pool/spa combination without in-floor cleaning system; Figure 4–existing pool/spa combination with infloor cleaning system.

In case you are building a new pool with an ICS or a new pool/spa combination with or without an ICS follow these general guidelines:

a.Plumb the Water Inlet to the Total Eclipse as shown in Figures 2, 3, and 4,

b.Plumb the Water Return out of the Total Eclipse as a dedicated line to the bottom of the pool as shown in Figure 1.

c.The recommended location to plumb the Total Eclipse inlet "T" is after the filter and before the heater.

NOTE: If returned directly to the skimmer, the ozonated water will be drawn back into the filtration system and will not mix with the pool water as effectively. If returned to the main return line, the line pressure (back-pressure) could cause a loss of suction and stop ozone from being mixed with the water, causing large bubbles to be trapped and released into the pool

5.Ensurethattheprovided5lb.checkvalveisinstalledatthe location and in the direction shown in the relevant figure.

NOTE:AninstalledcheckvalvewillnotaffecttheTotalEclipse if the check valve’s opening pressure is 1lb. or less.

continued on page 4

1