De'Longhi GB-5751019900 Owner's Manual

4
IMPORTANT SAFEGUARDS
DESCRIPTION 1
air outlet grille
2 control panel 3 castors 4 handles 5 filter 6 air intake grille 7 air exhaust hose housing 8 drainage hose 9 power cable
10 wall flange 11 suction pads 12 air exhaust hose 13 window outlet 14 castor locks 15 remote control 16 window bracket with locking pin
• Use this appliance only as described in this instruction manual. As with any electrical appliance, the instructions aim to cover as many eventualities as possi­ble. Caution and common sense should be used when operating and installing this air condi­tioner.
• This appliance has been manufactured to cool and dehumidify domestic environments and should not be used for other purposes.
• It is dangerous to alter or modify the unit's characteristics in any way.
• The appliance must be installed in line with the relevant national legislation.
• Should repairs be necessary, contact the nearest authorized Repair Service Center. Unautho­rized servicing can be dangerous.
• This appliance is to be used by adults only; keep away from children.
• In the case that the power cord becomes damaged, to protect against fire, it must be substituted only by specialized personnel authorized by the manufacturer.
• Always ensure the appliance is grounded. If you have any doubts check with a qualified elec­trician.
•We strongly discourage the use of an extension cord due to potential safety hazards.
• Before cleaning or maintenance operations, always unplug the unit from the outlet.
•Do not pull on or place strain on the power cord when moving the appliance.
• The appliance should not be installed where the atmosphere may contain combustible gases, oil or sulphur, or near heat sources.
• Do not rest hot or heavy objects on the appliance.
• Clean the filters at least once a week.
•Avoid using heaters near the unit.
• The unit should be transported in a vertical position. If this is not possible secure the unit at an angle, do not lie it horizontally.
• Before transporting the unit, drain the unit. After transportation, wait at least 1 hour before switch­ing the unit on.
• The packaging materials can be recycled. It is, therefore, recommended to place them in the special containers for differentiated waste collection.
• This appliance is fitted with a special safety device. When the compressor switches off, this device prevents it from switching on again for at least 3 minutes.
SAVE THESE INSTRUCTIONS
THIS PRODUCT IS FOR HOUSEHOLD ONLY
5
The instructions below will enable you to prepare your air conditioner for operation as efficiently as possible.
Before use, make sure the air intake and outlet grilles are unobstructed.
AIR-CONDITIONING WITHOUT INSTALLATION
Just a few simple steps and your comfort is ensured with your air conditioner:
• Fit the air exhaust hose in the housing
at the back of the appliance.
Insert it as shown in figure A.
7
12
For optimum results:
If you have a sash window, place the win-
dow bracket on the window sill, extend
the bracket fully within the window frame,
secure the bracket by using the locking pin
then lower the window onto the bracket.
Insert the window outlet of the exhaust
hose into the slot, then connect the hose
to the air conditioner (fig. B ).
12
13
16
Installing Your Portable
Air-Conditioner
Keep the air hose as short and free of curves as possible to avoid constrictions.
ELECTRICAL CONNECTIONS
Before plugging the appliance into the electrical socket, check that:
• The power supply corresponds to the value indicated on the rating plate on the back of the appliance;
• The socket and electrical circuit are adequate for the appliance;
• The socket matches the plug. If this is not the case, have the plug replaced;
• The socket is adequately grounded.
Failure to follow these important safety instructions absolves the manufacturer of all liability.
The power cable must be replaced by a qualified professional only.
B
Thanks to the locking pin, it’s possible to use the window bracket also for sliding windows. Position the hole of the bracket so to allow a correct installation of the exhaust hose.
French window
• Open the French window slightly and posi­tion the window outlet as shown in figure C.
13
A
D
• Use the suction pads provided to hold the two parts of the window together (fig. D).
11
C
in the window pane
in the wall: for optimum results, insulate the sec­tion of the wall with suitable insulating material.
in the wood­en kickboard of a French window
F
Preparing for use
SEMI-PERMANENT INSTALLATION
If required, your appliance can also be installed semi-permanently (Fig. E).
Proceed as follows:
• Drill a hole ø 134 mm (5.27 in.) in an out­side wall or through a window pane. Respect the dimensions and height of the hole given in figure F and G.
• Fit the wall flange into the hole.
• Fit the air exhaust hose in the housing
at the back of the appliance. (fig. A page
5).
• Fit the end of the air exhaust hose to
the wall flange as shown in fig. G.
10
12
12
10
G
NOTE: When installing the air conditioner
semi-permanently, you should leave a door slightly open (as little as 1/2 - in 1 cm ) to guar­antee correct ventilation.
6
E
Keep the air hose as short and free of curves as possible to avoid constrictions.
When the hose (12) is not fitted, the drilled hole can be closed with the flange cap (10).
30 cm 12 inches
30 cm 12 inches
MAX100 cm MAX 39 inches
MIN 35 cm MAX 14 inches
134
5,27 in.
7
Control panel
DESCRIPTION OF THE CONTROL PANEL
A ON/STAND-BY button B MODE selection button
Air conditioning, dehumidifying, fan.
C Fan speed selection button (HIGH/MED/LOW/AUTO) DTimer button E Programmed operation increase temperature/time button F Programmed operation decrease temperature/time button G Display Displays the temperature values set and the programmed operating time HTimer in operation indicator light I/L/M/N Fan speed lights and AUTO speed light O Fan mode light P Dehumidifying mode light Q Air-conditioning mode light R Remote control receiver
THE CONTROL PANEL
Q
A
BEF
N
HRG
C
P
O
D
M
L
I
8
Operation
TURNING THE APPLIANCE ON
Plug into the electrical socket. Two lines appear on the display indicating that the appliance is in stand­by. Press the ON/STAND-BY button (A). When turned on, the air conditioner starts operating in the same mode as when it was turned off. Press the MODE button (B) until the light corresponding to the required mode lights up:
Light (Q): air-conditioning mode
Light (P): dehumidifying mode
Light (O): fan mode
AIR-CONDITIONING MODE
Ideal for hot humid weather when you need to cool and dehumidify the room. To set operation of the appliance correctly, press the + (E) or - (F) buttons until the desired temperature is displayed.
Then select the fan speed by pressing the “FAN” button (C) until the light corresponding to the required fan speed lights up:
HIGH: the air conditioner operates at maximum to reach the required
temperature as rapidly as possible
MED:reduces noise levels but still maintains a good level of comfort LOW: for silent operation AUTO: the appliance automatically selects the most suitable fan speed
in relation to the temperature set on the digital display.
The most suitable temperature for the room during the summer varies from 24 to 27°C (75 to 81°F ). It is recommended, however, not to set a tem­perature much below the outdoor temperature.
DEHUMIDIFYING MODE
Ideal for reducing humidity in spring and autumn, during rainy spells or in damp rooms, etc. In dehumidifying mode, the appliance must have the same configuration as for the air conditioning mode, with the air exhaust hose fitted to the appliance to allow air to be discharged externally. When the dehumidifying mode is selected, the dehumidifying mode light (P) comes on and “ ” appears on the display. At the same time, the AUTO fan light (N) comes on. In this mode, other speeds cannot be selected.
FAN MODE
Adjust fan speed by pressing the “FAN” button (C) as described for the air-conditioning mode. In this mode, AUTO cannot be selected. The fan speed selected will be displayed.