De'Longhi GB-5751018500 Owner's Manual

20
Warnings
• This appliance is designed for home air conditioning and must not be used for other purposes.
• It is dangerous to modify or alter the characteristics of the appliance in any way.
• The appliance must be installed in conformity with legislation in force in the country concerned.
• If the appliance requires repair, contact a Service Centre authorised by the manufacturer only.
• Repairs carried out by unauthorised personnel may be dangerous.
• This air conditioning unit must be used by adults only. Never allow children to play with the appliance.
• This appliance is designed for home air conditioning and must not be used for other purposes.
• Do not allow children to play with the appliance.
• The appliance must be connected to an efficient earth system.
• Have your electrical circuit checked by a qualified electrician.
• Do not use extension cables.
• Before cleaning or maintenance operations, always unplug the appliance from the mains socket.
• Do not move the appliance by pulling the power cable.
• Do not install the appliance in rooms containing gas, oil or sulphur. Do not install near sources of heat. .
• Do not rest heavy or hot objects on top of the appliance.
• Clean the anti-microbial filters at least once a week.
•Avoid using heating appliances near the air conditioning unit.
•Always transport the appliance upright or resting on one side.
• Use the appliance as described in this instruction manual only.
• As with any electrical appliance, while the instructions aim to cover as many eventualities as possible, caution and common sense should be used when operating and installing this air conditioning unit.
• At the end of its working life, take the appliance to a special collection centre.
• The materials used for packaging can be recycled.
•You are therefore recommended to dispose of them in special differentiated waste collection contai­ners.
•When putting the appliance away, do not cover with plastic bags.
• The refrigerant gas R410a conforms to EC regulations on the environment. Avoid perforating the refrigerant circuit of the appliance.
• Keep the appliance at least 50 cm away from flammable substances (alcohol etc) or pressurised con­tainers (e.g. aerosol cans).
DESCRIPTION 1
air outlet grille
2 control panel 3 castors 4 handles 5 evaporator air intake grille 6 air exhaust hose housing 7 condenser air intake grille 8 drain hose cover 9 power cable 10 flange cap
11 air exhaust hose 12 window outlet 13 suckers 14 castor locks 15 remote control unit (certain models only) 16 adjustable window bar (certain models only)
D
uring the summer, you feel comfortable at a temperature of between 24 and 27° C with a
relative humidity of about 50%.
During the summer, you feel comfortable at a temperature of between 24 and 27° C with a rela­tive humidity of about 50%. Compared with installed models, portable air conditioning units have the advantage that they can be moved from one room to another in the home or be transported from one building to another.
Hot air from the room is passed through a coil cooled by refrigerant gas. Excess heat and moisture are removed before the air is re-emitted into the room. In single unit models (Pinguino), a small part of this air is used to cool the refrigerant gas and then, when hot and damp, is discharged outside. In models with case, the circuit is cooled using air from outside. All Pinguino models can also be used in fan-only mode.
21
ENGLISH
What is the Pinguino
22
The instructions below will enable you to prepare your air conditioning unit for operation as effi­ciently as possible.
The instructions below will enable you to prepare your air conditioning unit for operation as effi­ciently as possible.
AIR-CONDITIONING WITHOUT INSTALLATION
Just a few simple steps and your comfort is ensured with Pinguino:
• Fit the air exhaust hose in the housing
at the back of the appliance. Insert it as
shown in figure A.
6
11
If you have a double window, use the suckers provided to hold the two parts
of the window together (fig. C).
13
• Fit the window outlet Fit the window outlet .
• Place the air conditioning unit near a win­dow or French window.
• Make sure the air exhaust hose is unobstruc­ted.
• Open the window or French window sligh­tly and position the outlet as shown in figure B.
12
11
12
A
Preparing for use
B
C
Keep air hoses as short and free of cur­ves as possible to avoid constrictions.
ELECTRICAL CONNECTIONS
Before plugging the appliance into the mains socket, check that:
• the mains power supply corresponds to the value indicated on the rating plate on the back of the appliance;
• the mains socket and electrical circuit are adequate for the appliance;
• the mains socket matches the plug. If this is not the case, have the plug replaced;
• the mains socket is adequately earthed.
Failure to follow these important safety instructions absolves the manufacturer of all liability.
The power cable must be replaced by a qualified professional only.
23
ENGLISH
Using the adjustable bar (certain models only)
• Some models are provided with an adjusta­ble bar which can be useful if your home is fitted with roller blinds.
To fit the bar, proceed as follows:
- fit the window outlet in the housing in
the bar (fig. D).
- position the bar on the window sill
- extend the bar for the full length of the
window and fit it into the roller blind gui­des.
If you wish, you can block the bar in place using the pin supplied (fig. E), then lower the blind onto the bar.
12
Preparing for use
D
- fit the air exhaust hose to the window outlet and insert the other end of the hose into the back of the air conditioner (figure F).
12
11
E
F
1
2
2
1
24
Preparing for use
AIR-CONDITIONING WITH INSTALLATION
If required, the Pinguino can also be installed semi-permanently (Fig. G).
• Fit the flange accessory provided in the hole.
• Fit the hose in the housing at the back of the appliance (fig. A page 22).
• Fit the end of the hose to the flange
as shown in fig. I.
10
11
11
10
Proceed as follows:
• Drill a hole in an outside wall or through a window pane. Respect the dimensions of the hole and heights shown in figures H and I.
c
When the hose is not fitted, the hole can be
closed with the flange cap .
NOTE: When installing the air conditioning unit semi­permanently, you should leave a door slightly open (as little as 1 cm) to guarantee correct ventilation.
10
11
in the window pane
in the wall: you are recommended to insulate the sec­tion of wall using suitable insulation.
in the woo­den kick­board of a French win­dow
H
I
Keep the air hoses as short and free of curves as possible to avoid constrictions.
G
30 cm
30 cm
MAX100 cm
MIN 35
106
Loading...
+ 11 hidden pages